• Title/Summary/Keyword: Receiver sensitivity

Search Result 592, Processing Time 0.026 seconds

Overexpressed Ostepontin-c as a Potential Biomarker for Esophageal Squamous Cell Carcinoma

  • Zhang, Mei-Xiang;Xu, Yi-Jun;Zhu, Ming-Chen;Yan, Feng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.12
    • /
    • pp.7315-7319
    • /
    • 2013
  • Background: The metastasis gene osteopontin (OPN) is subject to alternative splicing, which yields three messages, osteopontin-a, osteopontin-b and osteopontin-c. Osteopontin-c is selectively expressed in invasive, but not in noninvasive tumors. In the present study, we examined the expression of OPN-c in esophageal squamous cell carcinomas (ESCCs) and assessed its value as a diagnostic biomarker. Methods: OPN-c expression was assessed by immunohistochemistry in 63 ESCC samples and correlated with clinicopathologic factors. Expression was also examined in peripheral blood mononuclear cells (PBMCs) from 120 ESCC patients and 30 healthy subjects. The role of OPN-c mRNA as a tumor marker was investigated by receiver operating characteristic curve (ROC) analysis. Results: Immunohistochemistry showed that OPN-c was expressed in 30 of 63 cancer lesions (48%)and significantly associated with pathological T stage (P=0.038) and overall stage (P=0.023). Real time PCR showed that OPN-c mRNA was expressed at higher levels in the PBMCs of ESCC patients than in those of healthy subjects (P<0.0001) with a sensitivity as an ESCC biomarker of 86.7%. Conclusion: Our findings suggest that expression of OPN-c is significantly elevated in ESCCs and this upregulation could be a potential diagnostic marker.

Salivary and Serum Interleukin-6 Levels in Oral Premalignant Disorders and Squamous Cell Carcinoma: Diagnostic Value and Clinicopathologic Correlations

  • Dineshkumar, Thayalan;Ashwini, Balakuntla Krishnamurthy;Rameshkumar, Annasamy;Rajashree, Padmanaban;Ramya, Ramadas;Rajkumar, Krishnan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.11
    • /
    • pp.4899-4906
    • /
    • 2016
  • Aim: To assess the diagnostic utility of serum and salivary interleukin 6 (IL-6) levels in the differential diagnosis of potentially malignant lesions and conditions (PMLs/PMCs) and oral squamous cell carcinoma (OSCC) in a high oral cancer prevalence region. Methods: After appropriate ethical clearance and informed consent, salivary and blood samples were collected from 100 participants in each group (OSCC, PMLs, and healthy controls). Serum and salivary IL-6 levels were measured by enzyme-linked immunosorbent assay and data were subjected to appropriate statistical analysis. Results: Significant differences in IL-6 concentration were noted between OSCC and PML/C patients in both serum and saliva, with salivary levels being 2 to 3 fold higher than serum values in all the groups. Receiver operating characteristic curve analysis demonstrated 96% specificity and 99% sensitivity for salivary IL-6 in differentiating PML from OSCC. Conclusions: The results of the present study suggest that the pro-inflammatory cytokine, IL-6, is elevated in the saliva of patients with OSSC compared to PMD and controls, and thus may prove to have diagnostic and/or prognostic significance.

Design of a Jammer Localization System using AOA method (AOA 기법을 이용한 재머 위치추적시스템 설계)

  • Lim, Deok-Won;Choi, Yun-Sub;Lee, Sang-Jeong;Hoe, Moon-Boem;Nam, Gi-Wook
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.6
    • /
    • pp.1241-1249
    • /
    • 2011
  • There are TOA, TDOA and AOA method to estimate the position of the electromagnetic wave transmitter by using the multiple receivers at the fixed position. Among these methods, AOA method is suitable for the jammer localization system. Because TOA method can be adopted for the clocks of the transmitter and the receiver are synchronized each other, and TDOA method can be only adopted for a broad-band jamming signal. This paper, therefore, analyzes the characteristics of the AOA measurements and the sensitivity of the positioning performance according to the system design parameters. Based on the analyzed results, the jammer localization system to meet the desired performance is designed, and it has been checked that the positioning error for the jammer located at a distance of 10km is lower than 38m through the simulation results.

S100ß, Matrix Metalloproteinase-9, D-dimer, and Heat Shock Protein 70 Are Serologic Biomarkers of Acute Cerebral Infarction in a Mouse Model of Transient MCA Occlusion

  • Choi, Jong-Il;Ha, Sung-Kon;Lim, Dong-Jun;Kim, Sang-Dae;Kim, Se-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.5
    • /
    • pp.548-558
    • /
    • 2018
  • Objective : Diagnosing acute cerebral infarction is crucial in determining prognosis of stroke patients. Although many serologic tests for prompt diagnosis are available, the clinical application of serologic tests is currently limited. We investigated whether $S100{\beta}$, matrix metalloproteinase-9 (MMP-9), D-dimer, and heat shock protein 70 (HSP70) can be used as biomarkers for acute cerebral infarction. Methods : Focal cerebral ischemia was induced using the modified intraluminal filament technique. Mice were randomly assigned to 30-minute occlusion (n=10), 60-minute occlusion (n=10), or sham (n=5) groups. Four hours later, neurological deficits were evaluated and blood samples were obtained. Infarction volumes were calculated and plasma $S100{\beta}$, MMP-9, D-dimer, and HSP70 levels were measured using enzyme-linked immunosorbent assay. Results : The average infarction volume was $12.32{\pm}2.31mm^3$ and $46.9{\pm}7.43mm^3$ in the 30- and 60-minute groups, respectively. The mean neurological score in the two ischemic groups was $1.6{\pm}0.55$ and $3.2{\pm}0.70$, respectively. $S100{\beta}$, MMP-9, and HSP70 expressions significantly increased after 4 hours of ischemia (p=0.001). Furthermore, $S100{\beta}$ and MMP-9 expressions correlated with infarction volumes (p<0.001) and neurological deficits (p<0.001). There was no significant difference in D-dimer expression between groups (p=0.843). The area under the receiver operating characteristic curve (AUC) showed high sensitivity and specificity for MMP-9, HSP70 (AUC=1), and $S100{\beta}$ (AUC=0.98). Conclusion : $S100{\beta}$, MMP-9, and HSP70 can complement current diagnostic tools to assess cerebral infarction, suggesting their use as potential biomarkers for acute cerebral infarction.

Usefulness of Korean Version of Behavioral Cue Checklist for Predicting of Patient Violence in Emergency Departments (응급실에서의 폭력 환자 예측을 위한 한국어판 행동신호 사정도구의 유용성 검증)

  • Kim, Jang Mi;Lee, Eun Nam
    • Journal of Korean Academy of Nursing
    • /
    • v.48 no.3
    • /
    • pp.289-297
    • /
    • 2018
  • Purpose: This study aimed to evaluate the usefulness of a behavioral cue checklist (BCC) containing 17 items developed by Wilkes et al. (2010) for identifying potentially violent patients in emergency departments. Methods: This was a prospective observational study to evaluate the usefulness of the Korean version of a BCC (K-BCC) as an assessment tool for predicting patient violence in emergency departments, and was conducted over 4 weeks in a regional emergency medical center located in B City. A total of 1,324 patients were finally analyzed. Results: Logistic regression analysis was performed to investigate whether each item of the K-BCC predicts violence, and a parsimonious set of 8 statistically significant items was selected for the tool. Receiver operating characteristic analysis of the BCC showed that the area under the curve was .97 (95% confidence interval: .94~1.0). The sensitivity, specificity, positive predictive value, and negative predictive value at the cut-off score of 2 were 75.6%, 98.9%, 68.2%, and 99.2%, respectively. Conclusion: The K-BCC was found to be useful in predicting patient violence toward emergency department staff. This tool is simple, and fast to use and can play a significantly role identifying potentially violent patients. Owing to this advance identification, this tool can be helpful in preventing the potential for violence from manifesting as violent behaviors.

Body composition: A predictive factor of cycle fecundity

  • Kayatas, Semra;Boza, Aysen;Api, Murat;Kurt, Didar;Eroglu, Mustafa;Arinkan, Sevcan Arzu
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.41 no.2
    • /
    • pp.75-79
    • /
    • 2014
  • Objective: To study the effect of body composition on reproduction in women with unexplained infertility treated with a controlled ovarian hyperstimulation and intrauterine insemination programme. Methods: This prospective observational study was conducted on 308 unexplained infertile women who were scheduled for a controlled ovarian hyperstimulation and intrauterine insemination programme and were grouped as pregnant and non-pregnant. Anthropometric measurements were performed using TANITA-420MA before the treatment cycle. Body composition was determined using a bioelectrical impedance analysis system. Results: Body fat mass was significantly lower in pregnant women than in non-pregnant women ($15.61{\pm}3.65$ vs. $18.78{\pm}5.97$, respectively) (p=0.01). In a multiple regression analysis, body fat mass proved to have a stronger association with fecundity than the percentage of body fat, body mass index, or the waist/hip ratio (standardized regression coefficient${\geq}0.277$, t-value ${\geq}2.537$; p<0.05). The cut-off value of fat mass, which was evaluated using the receiver operating characteristics curve, was 16.65 with a sensitivity of 61.8% and a specificity of 70.2%. Below this cut-off value, the odds of the pregnancy occurrence was found to be 2.5 times more likely. Conclusion: Body fat mass can be predictive for pregnancy in patients with unexplained infertility scheduled for a controlled ovarian hyperstimulation and intrauterine insemination programme.

EEFL using intelligent lighting system control device (EEFL을 이용한 지능형 조명시스템 제어장치)

  • Park, Yang-Jae
    • Journal of Digital Convergence
    • /
    • v.11 no.4
    • /
    • pp.229-234
    • /
    • 2013
  • The purpose of this study is to develop a lighting apparatus of the illuminance and color temperature to maximize the ability of the optimal combination of light sources that can be controlled efficiently control device. Finding people comfortable feeling for indoor lighting that can be used in a variety of color temperature illumination area by combining light sensitivity can be realized. Lighting apparatus for fluorescent lamps with different color temperature of 2000K and 8000K, and by varying the quantity of each of the fluorescent lamps, the illuminance of lighting equipment and color temperature through optical simulations were evaluated. By infrared remote control receiver, divided into 5 types of relaxation, conversation, meeting, hospitality, arts and the lighting environment you want to transfer the PC0 ~ PC4 through the parallel port on the mode selected by the user at the receiving end the DC voltage output. EEFL inverter input DC voltage and the DC input voltage, depending on the level of EEFL dimming value (illuminance and color temperature) lighting environment you want to create change while using a PIR sensor EEFL automatically turn off if people do not have was developed so that the power consumption so you can save.

Diagnosis and prediction of periodontally compromised teeth using a deep learning-based convolutional neural network algorithm

  • Lee, Jae-Hong;Kim, Do-hyung;Jeong, Seong-Nyum;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.2
    • /
    • pp.114-123
    • /
    • 2018
  • Purpose: The aim of the current study was to develop a computer-assisted detection system based on a deep convolutional neural network (CNN) algorithm and to evaluate the potential usefulness and accuracy of this system for the diagnosis and prediction of periodontally compromised teeth (PCT). Methods: Combining pretrained deep CNN architecture and a self-trained network, periapical radiographic images were used to determine the optimal CNN algorithm and weights. The diagnostic and predictive accuracy, sensitivity, specificity, positive predictive value, negative predictive value, receiver operating characteristic (ROC) curve, area under the ROC curve, confusion matrix, and 95% confidence intervals (CIs) were calculated using our deep CNN algorithm, based on a Keras framework in Python. Results: The periapical radiographic dataset was split into training (n=1,044), validation (n=348), and test (n=348) datasets. With the deep learning algorithm, the diagnostic accuracy for PCT was 81.0% for premolars and 76.7% for molars. Using 64 premolars and 64 molars that were clinically diagnosed as severe PCT, the accuracy of predicting extraction was 82.8% (95% CI, 70.1%-91.2%) for premolars and 73.4% (95% CI, 59.9%-84.0%) for molars. Conclusions: We demonstrated that the deep CNN algorithm was useful for assessing the diagnosis and predictability of PCT. Therefore, with further optimization of the PCT dataset and improvements in the algorithm, a computer-aided detection system can be expected to become an effective and efficient method of diagnosing and predicting PCT.

Validation of a Modified Early Warning Score to Predict ICU Transfer for Patients with Severe Sepsis or Septic Shock on General Wards (일반병동 내 중증 패혈증 또는 패혈성 쇼크 환자의 중환자실 전동 예측에 대한 수정조기경고점수(Modified Early Warning Score)의 타당성)

  • Lee, Ju Ry;Choi, Hye Ran
    • Journal of Korean Academy of Nursing
    • /
    • v.44 no.2
    • /
    • pp.219-227
    • /
    • 2014
  • Purpose: To assess whether the Modified Early Warning Score (MEWS) predicts the need for intensive care unit (ICU) transfer for patients with severe sepsis or septic shock admitted to general wards. Methods: A retrospective chart review of 100 general ward patients with severe sepsis or septic shock was implemented. Clinical information and MEWS according to point of time between ICU group and general ward group were reviewed. Data were analyzed using multivariate logistic regression and the area under the receiver operating characteristic curves with SPSS/WIN 18.0 program. Results: Thirty-eight ICU patients and sixty-two general ward patients were included. In multivariate logistic regression, MEWS (odds ratio [OR] 2.02, 95% confidence interval [CI] 1.43-2.85), lactic acid (OR 1.83, 95% CI 1.22-2.73) and diastolic blood pressure (OR 0.89, 95% CI 0.80-1.00) were predictive of ICU transfer. The sensitivity and the specificity of MEWS used with cut-off value of six were 89.5% and 67.7% for ICU transfer. Conclusion: MEWS is an effective predictor of ICU transfer. A clinical algorithm could be created to respond to high MEWS and intervene with appropriate changes in clinical management.

A Design and Implementation of 4×10 Gb/s Transimpedance Amplifiers (TIA) Array for TWDM-PON (TWDM-PON 응용을 위한 4×10 Gb/s Transimpedance Amplifier 어레이 설계 및 구현)

  • Yang, Choong-Reol;Lee, Kang-Yoon;Lee, Sang-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39B no.7
    • /
    • pp.440-448
    • /
    • 2014
  • A $4{\times}10$ Gb/s Transimpedance Amplifier (TIA) array is implemented in $0.13{\mu}m$ CMOS process technology, which will be used in the receiver of TWDM-PON system. A technology for bandwidth enhancement of a given $4{\times}10$ Gb/s TIA presented under inductor peaking technology and a single 1.2V power supply based low voltage design technology. It achieves 3 dB bandwidth of 7 GHz in the presence of a 0.5 pF photodiode capacitance. The trans-resistance gain is $50dB{\Omega}$, while 48 mW/ 1channel from a 1.2 V supply. The input sensitivity of the TIA is -27 dBm. The chip size is $1.9mm{\times}2.2mm$.