• Title/Summary/Keyword: Receive voltage

Search Result 59, Processing Time 0.021 seconds

Multiple LCD System Development of daisy-chain Method using LVDS (LVDS를 이용한 daisy-chain 방식의 다중 LCD 시스템 개발)

  • Kim, Jae-Chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.12
    • /
    • pp.2747-2754
    • /
    • 2012
  • This thesis explains the development of multiple LCD system with the additional function to maximize the utilization of PC contents. The newly developed system is composed of host LCD and slave LCD. Host LCD decodes and outputs the image and voice of NTSC, PAL, SECAM signals. It also converts the decoded signals into LVDS signals before transmitting them to slave LCD stage. In addition, the installation of CF Memory and USB Memory helps display multi-media data. Unlike the host LCD, since not including the tuner and memory part, the slave LCD can't receive TV signals and play video signals. It only has the function to receive LVDS image signals and display on a LCD panel. This newly developed multi-LCD system has competitiveness in various aspects. With its simple structure, the failure rate, price and display power are relatively low due to its simplification of the control part. It has price and functional competitiveness as the product whose host LCD can control the entire slave LCD in terms of channel, volume, and video output.

A Reconfigurable Analog Front-end Integrated Circuit for Medical Ultrasound Imaging Systems (초음파 의료 영상 시스템을 위한 재구성 가능한 아날로그 집적회로)

  • Cha, Hyouk-Kyu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.66-71
    • /
    • 2014
  • This paper presents an analog front-end integrated circuit (IC) for medical ultrasound imaging systems using standard $0.18-{\mu}m$ CMOS process. The proposed front-end circuit includes the transmit part which consists of 15-V high-voltage pulser operating at 2.6 MHz, and the receive part which consists of switch and a low-power low-noise preamplifier. Depending on the operation mode, the output driver in the transmit pulser can be reconfigured as the switch in the receive path and thus the area of the overall front-end IC is reduced by over 70% in comparison to previous work. The designed single-channel front-end prototype consumes less than $0.045mm^2$ of core area and can be utilized as a key building block in highly-integrated multi-array ultrasound medical imaging systems.

High Noise Margin LVDS I/O Circuits for Highly Parallel I/O Environments (다수의 병렬 입.출력 환경을 위한 높은 노이즈 마진을 갖는 LVDS I/O 회로)

  • Kim, Dong-Gu;Kim, Sam-Dong;Hwang, In-Seok
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.1
    • /
    • pp.85-93
    • /
    • 2007
  • This paper presents new LVDS I/O circuits with a high noise margin for use in highly parallel I/O environments. The proposed LVDS I/O includes transmitter and receiver parts. The transmitter circuits consist of a differential phase splitter and a output stage with common mode feedback(CMFB). The differential phase splitter generates a pair of differential signals which have a balanced duty cycle and $180^{\circ}$ phase difference over a wide supply voltage variation due to SSO(simultaneous switching output) noises. The CMFB output stage produces the required constant output current and maintains the required VCM(common mode voltage) within ${\pm}$0.1V tolerance without external circuits in a SSO environment. The proposed receiver circuits in this paper utilizes a three-stage structure(single-ended differential amp., common source amp., output stage) to accurately receive high-speed signals. The receiver part employs a very wide common mode input range differential amplifier(VCDA). As a result, the receiver improves the immunities for the common mode noise and for the supply voltage difference, represented by Vgdp, between the transmitter and receiver sides. Also, the receiver produces a rail-to-rail, full swing output voltage with a balanced duty cycle(50% ${\pm}$ 3%) without external circuits in a SSO environment, which enables correct data recovery. The proposed LVDS I/O circuits have been designed and simulated with 0.18um TSMC library using H-SPICE.

GABAergic Synaptic Input to Mesencephalic Trigeminal Neurons in Rat

  • Ryu, Hyo-Chel;Piao, Zheng Gen;Choi, Se-Young;Lee, Sung-Joong;Park, Kyung-Pyo;Kim, Joong-Soo;Oh, Seog-Bae
    • International Journal of Oral Biology
    • /
    • v.30 no.2
    • /
    • pp.71-76
    • /
    • 2005
  • The mesencephalic trigeminal nucleus (Mes V) contains cell bodies of primary afferent sensory neurons that relay proprioceptive information from the periodontium and masticatory muscles and function as typical sensory neurons or potentially as integrative interneurons. In the present study, we studied these two potential functions using combined experimental approaches of retrograde labeling and whole cell patch clamp recording. Mes V neurons that presumably originate from periodontal nerve fibers in subsets of Mes V nucleus were identified by retrograde labeling with a fluorescent dye, DiI, which was applied onto inferior alveolar nerve. These cells were elliptical perikarya shaped cells about $40{\mu}m$ in diameter. In these neurons, we measured high voltage-activated calcium channel (HVACC) currents. $GABA_B$ agonist, baclofen, inhibited calcium currents, and the HVACC currents inhibition by baclofen was voltage-dependent, exhibited prepulse facilitation, indicating that it was mediated by $G_i/_G_o$ protein. Taken together, our results demonstrate that Mes V neurons not only have cell bodies originating from periodontium, but also receive synaptic inputs including GABAergic neurons suggesting that Mes V neurons function as both primary sensory neurons and integrative interneurons.

The implementation of remote IPMC control system using android smartphone (안드로이드 스마트폰 기반의 원격 IPMC 제어시스템 구현)

  • Kim, Gwan-Hyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.3
    • /
    • pp.533-539
    • /
    • 2013
  • Recently, Ionic Polymer Metal Composite (IPMC) systems receive great attention in the fields of the medical and biomedical Engineering because of several merits in terms of new actuators and sensors and fuel cell materials. When the voltage is excited to IPMC system, it moves. Conversely, if there are any movement on the IPMC, the IPMC has charge voltage by the internal properties. Therefore the IPMC can be used as a motion sensor or force sensor. In this paper, we identify characteristics of the IPMC and control its movements from remote locations by the smart-phone system based on visual information for monitoring. Additionally, control of movements of the IPMC is realized by transmit motion commands using the smart-phone system with the blue-tooth communication. Unfortunately, there are some deficiencies to perfectly attain physical properties of the IPMC systems from our experiments in this paper. However, in its utilization point of view, we demonstrate that the IPMC has some potentials as new sensors, actuators, and fuel cells.

On the Design of Power Supply System for Freight Train Reefer Container Based on Simulation

  • Kim, Joouk;Hwang, Sunwoo;Lee, Jae-Bum;Hwang, Jaemin;Chae, Uri
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.3
    • /
    • pp.249-257
    • /
    • 2022
  • In recent years, if we order food by easily accessing the online market with our smartphone, we can receive the product in a fresh state at dawn the next day. Cold chain is an industry that can create high added value because it has both the characteristics of general logistics and sensitivity to temperature. Based on the electrical specifications derived from the reefer container capacity requirement investigation, we proved that power supply to up to 33 reefer containers can be made by using three additional auxiliary power supplies which are applied for freight trains in Korea. In this paper, we conducted a research on a design of power supply system for freight train reefer container based on simulation as a basic research necessary for low-temperature distribution and cold chain construction based on the reefer container railroad. Consequently, the simulation was conducted using the three-phase inverter diagram in PSIM and the SVPWM (3-harmonic injection method) control technique, and it was verified that the required power voltage was satisfied with 622Vdc, which is lower than the input voltage of general SPWM of 718Vdc. The details of this paper could be used as a foundational study for constructing cold chains based on a reefer container dedicated to freight trains in the future.

A Performance Evaluation of Diagnostic X-ray Unit Depends on the Hospitals Size (병원 규모별 진단용 X선 발생장치의 성능 평가)

  • Park, Ju-Hun;Im, In-Chul;Dong, Kyung-Rae;Kang, Se-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.1
    • /
    • pp.31-36
    • /
    • 2009
  • The purpose of this study is to measure the tube voltage, the tube current/volume, exposure time and exposure dose of diagnostic X-ray unit in each doctor offices, hospitals and general hospitals for evaluating the performance of such device, to learn the method and technology of its measurement and to suggest its importance. Research subjects were total 30 X-ray units and divided into groups of 10 X-ray units each. The tube voltage, the tube current/volume, exposure time and exposure dose were measured using percentage average error, and then reproducibility of exposure dose was measured through calculating coefficient of variation. The results are like followings; The tube voltage correctness examination showed that incongruent devices among total 30 X-ray units were 5 devices (16.7%). The tube current correctness examination showed that incongruent X-ray units were 3 devices (10.0%). The tube current volume correctness examination showed that incongruent X-ray units were 4 devices (13.3%). Finally, according to exposure time correctness examination, incongruent X-ray units were 5 devices (16.7%) and according to reproducibility examination of exposure dose, incongruent X-ray units were 7 devices (23.3%). Above results showed serious problem in performance management based on management regulation of diagnostic X-ray unit; it means that regular checkout and safety management are required, and as doing so, patients will be able to receive good quality of medical service by the reduction of radiation exposure time, image quality administration, unnecessary retake and etc. Therefore, this study suggests that the performance of diagnostic X-ray units should be checked regularly.

Design of A 3V CMOS Programmable Gain Amplifier for the Information Signal Processing System (정보처리 시스템용 3V CMOS 프로그래머블 이득 증폭기 설계)

  • 송제호;김환용
    • Journal of Korea Multimedia Society
    • /
    • v.5 no.6
    • /
    • pp.753-758
    • /
    • 2002
  • In this paper, low voltage 3V CMOS programmable gain amplifier(PGA) for using in the transmitter and receiver of ADSL analog front-end is designed. The designed receive PGA is connected with 1.1MHz continuous lowpass fillet and controls the gain from 0dB to 30dB. And also the transmitter PGA is connected with 138KHz lowpass filter and controls the gain from -15dB to 0dB. The gain of All PGAs can be programmed by digital logic circuits and main controller. The designed PGAs are verified using HSPICE simulation with $0.35\mu{m}$ CMOS parameter.

  • PDF

A Study on Development of Open-Phase Protector Having Leakage Current Generation and Incapable Operation Prevention at Open-Phase Accident (결상 시 누전전류 발생과 오동작 방지 기능을 갖는 결상보호기 개발에 관한 연구)

  • Kwak, Dong-Kurl
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.1
    • /
    • pp.182-187
    • /
    • 2015
  • In the three-phase power system, when any one-phase or two-phases is open-phase, the unbalanced current flows and the single-phase power supplies to three-phase loads. Specially, motor coil and transformer coil receive over-current. As a result, great damage as well as electrical fire can occur to the power system. In order to improve these problems, this paper proposes that an open-phase detection device is designed by a new algorithm using electric potential difference between the resultant voltage of neutral point and ground, and a control circuit topology of open-phase protector is composed of highly efficient semiconductor devices. It improves response speed and reliability. The control algorithm circuit also operates the cut-off of a conventional residual current protective device (RCD) which flows an enforced leakage current to ground wire at open-phase accident. Furthermore, time delay circuit is added to prevent the incapable operation of open-phase protector about instantaneous open-phase not open-phase fault. The time delay circuit improves more reliability.

Implementation of Quad-Band p-HEMT SP6T Switch for Handset Applications (개인 휴대통신용 4중대역 p-HEMT SR6T 스위치 구현)

  • Shin, One-Chul;Jeong, In-Ho
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.1
    • /
    • pp.97-101
    • /
    • 2011
  • Quad band p-HEMT SP6T switch for handset applications was developed. To achieve the low insertion loss and high isolation, trade-off between "On" state and "Off" state was considered by optimization of unit cell. Especially, in case isolation between transmit port and receive port, it was achieved by large capacitors and miniaturization of chip size was achieved by common voltage control and ground using back via process. Designed SP6T switch has size of $950um{\times}100um$ and take into consideration the gate recess error, excellent loss and isolation was confirmed in operating frequency.