• Title/Summary/Keyword: Real-time imaging

Search Result 536, Processing Time 0.024 seconds

Study of a Brain Tumor and Blood Vessel Detection System Using Multiple Fluorescence Imaging by a Surgical Microscope (수술현미경에서의 다중형광영상을 이용한 뇌종양과 혈관영상 검출 시스템 연구)

  • Lee, Hyun Min;Kim, Hong Rae;Yoon, Woong Bae;Kim, Young Jae;Kim, Kwang Gi;Kim, Seok Ki;Yoo, Heon;Lee, Seung Hoon;Shin, Min Sun;Kwon, Ki Chul
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.1
    • /
    • pp.23-29
    • /
    • 2015
  • In this paper, we propose a microscope system for detecting both a tumor and blood vessels in brain tumor surgery as fluorescence images by using multiple light sources and a beam-splitter module. The proposed method displays fluorescent images of the tumor and blood vessels on the same display device and also provides accurate information about them to the operator. To acquire a fluorescence image, we utilized 5-ALA (5-aminolevulinic acid) for the tumor and ICG (Indocyanine green) for blood vessels, and we used a beam-splitter module combined with a microscope for simultaneous detection of both. The beam-splitter module showed the best performance at 600 nm for 5-ALA and above 800 nm for ICG. The beam-splitter is flexible to enable diverse objective setups and designed to mount a filter easily, so beam-splitter and filter can be changed as needed, and other fluorescent dyes besides 5-ALA and ICG are available. The fluorescent images of the tumor and the blood vessels can be displayed on the same monitor through the beam-splitter module with a CCD camera. For ICG, a CCD that can detect the near-infrared region is needed. This system provides the acquired fluorescent image to an operator in real time, matching it to the original image through a similarity transform.

Development of 1.0 Tesla Compact MRI System (1.0 Tesla 자기 공명 진단 장치의 개발)

  • Lee, H.K.;Oh, C.H.;Ahn, C.B.;Chang, Y.H.;Shin, D.W.;Lee, K.N.;Jang, K.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.129-134
    • /
    • 1996
  • 1차 년도 G-7 개발 과제로 수행된 자기 공명 진단 장치 (Magnetic Resonance Imaging System)의 개발 내용을 간략히 소개하였다. 성공적인 IT Compact 자기 공명 진단 장치의 완성을 위해 일차적으로 (1)RF (고주파), Gradient(경사 자계), Spectrometer 등의 Hard-ware 관련 MRI 핵심부분, (2) RF, Gradient, Spectrometer, Magnet 등의 각 Sub-system을 연결, 조합, 조정하여 하나의 체계적인 시스템으로 통합하고 운영하는 과정(System Integration), (3)사용자와 시스템을 연결하는 User Interface, Data Base Management, Real time 운영 SW 등과 (4)임상에 적용하여 구체적인 성능과 효용성을 확인하는 기술 등에 대하여 집중 연구하였다. 개발 방법은 (1)지난 16년간 국내에 축적 된 연구 개발 인력들을 최대한 활용하고 (2)연구 개발을 국제화 시켜 필요한 경우 부분별로 개발 인력을 해외에서 보완하고 (3)소수 정예 전문 인력 주의와 요소 기술 또는 중요 부품을 경쟁성 검토 후 필요 시 Out-sourcing 활용으로 최저의 비용으로 개발 기간을 최소화 하는 데 두었다. 개발된 1.0Tesla자기 공명 영상 장치는 미국 물리 학회에서 규격화한 Phantom및 임상 적용을 통하여 서울대 의대 연구 팀과 지속적으로 성능을 평가해 왔다. 개발된 시스템의 해상도는 $256{\times}256$ head 영상에서 1mm 이 하의 해상도를 가짐을 resolution phantom 을 통하여 확인할 수 있었고, $512{\times}512$ 영상에서 는 약 0.5 mm 의 물체를 분리 해냄으로써 외제 시스템들 보다 우수하게 평가 되었다. 차폐 경사코일의 Eddy current영향은2%이내로 촬영 시 영향은 거의 무시할 수 있었다. 또한, 개발된 영상 기법들, 즉 Multislice/Multi Echo, Oblique angle imaging, 64 Echo train을 갖는 고속 촬영 기술들이 자기 공명 장치에 장착되어 임상 적용에 문제가 없도록 하였다. 또한 20mT/m/Amp의 강력한 능동 차폐 경사 자계 코일(Active Shield Gradient Coil)을 기본 사양으로 하고, 수신단을 최대 6개로 확장토록 하여 2차년도의 초고속 촬영 기법(EPI) 및 Phased Array 코일 촬영이 가능토록 하였다. 1차 년도 개발 과제 수행 결과와 향후 개발 과제를 바탕으로 최종 목표인 국제 경쟁력이 있는 자기 공명 진단 장치 즉 기능과 영상의 질은 선진국 제품과 동일하거나 우수하되, 저가격을 구현한 상용화 제품이 완성되어, 첨단 의료기기로서 산업 구조 고도화에 기여하고 수입대체 뿐만 아니 라 수출을 통한 국익 창출과 국가의 기술을 통한 위상 제고에 기여되길 기대한다.

  • PDF

FMD response cow hooves and temperature detection algorithm using a thermal imaging camera (열화상 카메라를 이용한 구제역 대응 소 발굽 온도 검출 알고리즘 개발)

  • Yu, Chan-Ju;Kim, Jeong-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.292-301
    • /
    • 2016
  • Because damages arising from the occurrence of foot-and-mouth disease (FMD) are very great, it is essential to make a preemptive diagnosis to cope with it in order to minimize those damages. The main symptoms of foot-and-mouth disease are body temperature increase, loss of appetite, formation of blisters in the mouth, on hooves and breasts, etc. in a cow or a bull, among which the body temperature check is the easiest and quickest way to detect the disease. In this paper, an algorithm to detect FMD from the hooves of cattle was developed and implemented for preemptive coping with foot-and-mouth disease, and a hoof check test is conducted after the installation of a high-resolution camera module, a thermo-graphic camera, and a temperature/humidity module in the cattle shed. Through the algorithm and system developed in this study, it is possible to cope with an early-stage situation in which cattle are suspected as suffering from foot-and-mouth disease, creating an optimized growth environment for cattle. In particular, in this study, the system to cope with FMD does not use a portable thermo-graphic camera, but a fixed camera attached to the cattle shed. It does not need additional personnel, has a function to measure the temperature of cattle hooves automatically through an image algorithm, and includes an automated alarm for a smart phone. This system enables the prediction of a possible occurrence of foot-and-mouth disease on a real-time basis, and also enables initial-stage disinfection to be performed to cope with the disease without needing extra personnel.

Catadioptric Omnidirectional Optical System Using a Spherical Mirror with a Central Hole and a Plane Mirror for Visible Light (중심 구멍이 있는 구면거울과 평면거울을 이용한 가시광용 반사굴절식 전방위 광학계)

  • Seo, Hyeon Jin;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.2
    • /
    • pp.88-97
    • /
    • 2015
  • An omnidirectional optical system can be described as a special optical system that images in real time a panoramic image with an azimuthal angle of $360^{\circ}$ and the altitude angle corresponding to the upper and lower fields of view from the horizon line. In this paper, for easy fabrication and compact size, we designed and fabricated a catadioptric omnidirectional optical system consisting of the mirror part of a spherical mirror with a central hole (that is, obscuration), a plane mirror, the imaging lens part of 3 single spherical lenses, and a spherical doublet in the visible light spectrum. We evaluated its image performance by measuring the cut-off spatial frequency using automobile license plates, and the vertical field of view using an ISO 12233 chart. We achieved a catadioptric omnidirectional optical system with vertical field of view from $+53^{\circ}$ to $-17^{\circ}$ and an azimuthal angle of $360^{\circ}$. This optical system cleaniy imaged letters on a car's front license plate at the object distance of 3 meters, which corresponds to a cut-off spatial frequency of 135 lp/mm.

Implementation of KV Cone Beam CT for Image Guided Radiation Therapy (영상유도 방사선치료에서의 KV 콘빔CT 이용)

  • Yoo, Young-Seung;Lee, Hwa-Jung;Kim, Dae-Young;Yu, Ri
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.43-49
    • /
    • 2007
  • Purpose: The aim of this study was the clinical implementation of IGRT using KV CBCT for setup correction in radiation therapy. Materials and Methods: We selected 9 patients (3 patient for each region; head, body, pelvis)and acquired 135 CBCT images with CLINAC iX (Varian medical system, USA). During the scan, the required time was measured. We analyzed the result in 3 direction; vertical, longitudinal, lateral. Results: The mean setup errors at the couch position of vertical, lateral, and longitudinal direction were 0.07, 0.12, and 0.1 cm in the head region, 0.3, 0.26, and 0.22 cm in the body region, 0.21, 0.18, and 0.15 cm in the pelvis region respectively. The mean time required for CBCT was $6{\sim}7$ minute. Conclusion: The CBCT on the LINAC provides the capacity for soft tissue imaging in the treatment position and real time monitoring during treatment delivery. With presented workflow, the setup correction within reasonable time for more accurate radiation therapy is possible. And it's image can be very useful for adaptive radiation therapy(ART) in the future with improved image quality.

  • PDF

Relationship between Muscle Strength and Tendon Stiffness of the Ankle Plantarflexors and Its functional Consequence (인체 족저굴곡근의 근력과 아킬레스 건의 경도, 기능적 능력 간 상관관계 분석)

  • Han, Seong-Won;Lee, Dae-Yeon;Lee, Hae-Dong
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.1
    • /
    • pp.35-42
    • /
    • 2014
  • Tendon elasticity is an important factor affecting muscle function and thus human movements. It has been reported that the mechanical properties of tendon are adaptable to external loading condition. Based on the adaptability of muscle and tendon to external loading conditions, one can assume that there might be an optimum ratio between muscle strength and tendon stiffness. The present study aimed to investigate whether there is correlation between plantar flexor muscle strength and stiffness of the achilles tendon (AT). Twenty two male subjects (age: $23.2{\pm}1.5yrs$, height: $175.5{\pm}6.2cm$, weight: $75.4{\pm}9.8kg$) performed maximum voluntary isometric plantarflexion on a custom-built dynamometer and muscle-tendon junction of the medial gastrocnemius muscle was simultaneously monitored using a real-time ultrasound imaging machine. The averages of muscle force and tendon stiffness were $366.38{\pm}79.37N$, $35.34{\pm}10.42N/mm$, respectively. Significant positive correlation was observed between muscle strength and tendon stiffness (r=0.8507), indicating that the muscle force is proportional to tendon stiffness. The results might have been used in computational modeling and criterion of training progress level in the fields of training and rehabilitation.

Combined EGFR and c-Src Antisense Oligodeoxynucleotides Encapsulated with PAMAM Denderimers Inhibit HT-29 Colon Cancer Cell Proliferation

  • Nourazarian, Ali Reza;Najar, Ahmad Gholamhoseinian;Farajnia, Safar;Khosroushahi, Ahmad Yari;Pashaei-Asl, Roghiyeh;Omidi, Yadollah
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.9
    • /
    • pp.4751-4756
    • /
    • 2012
  • Colon cancer continues to be one of the most common cancers, and the importance and necessity of new therapies needs to be stressed. The most important proto-oncogen factors for colon cancer appear to be epidermal growth factor receptor, EGFR, and c-Src with high expression and activity leading to tumor growth and ultimately to colon cancer progression. Application of c-Src and EGFR antisense agents simultaneously should theoretically therefore have major benefit. In the present study, anti-EGFR and c-Src specific antisense oligodeoxynucleotides were combined in a formulation using PAMAM dendrimers as a carrier. Nano drug entry into cells was confirmed by flow cytometry and fluorescence microscopy imaging and real time PCR showed gene expression of c-Src and EGFR, as well as downstream STAT5 and MAPK-1 with the tumor suppressor gene P53 to all be downregulated. EGFR and c-Src protein expression was also reduced when assessed by western blotting techniques. The effect of the antisense oligonucleotide on HT29 cell proliferation was determined by MTT assay, reduction beijng observed after 48 hours. In summary, nano-drug, anti-EGFR and c-Src specific antisense oligodeoxynucleotides were effectively transferred into HT-29 cells and inhibited gene expression in target cells. Based on the results of this study it appears that the use of antisense EGFR and c-Src simultaneously might have a significant effect on colon cancer growth by down regulation of EGFR and its downstream genes.

Power Doppler ultrasound-guided sialography using the phenomenon of increased blood flow: A technical report

  • Oh, Song Hee;Seo, Yu-Kyeong;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.49 no.4
    • /
    • pp.301-306
    • /
    • 2019
  • Purpose: This report presents a procedure for performing power Doppler ultrasound-guided sialography using the phenomenon of increased blood flow and illustrates its application to practical patient cases. Materials and Methods: The salivary gland was scanned using ultrasound equipment (GE LOGIQ5 Expert® device; GE Medical Systems, Milwaukee, WI, USA) to identify pathological findings related to the patient's chief complaint. To identify the orifice of the main duct, it should be cannulated using a lacrimal dilator. After inserting the catheter into the cannulated main duct, the position of the catheter within the duct was confirmed by ultrasound. A contrast agent was injected until the patient felt fullness, and ultrasound (B-mode) was used to confirm whether the contrast agent filled the main canal and secondary and tertiary ducts. Then, power Doppler ultrasound was performed to determine whether the salivary gland had increased blood flow. Results: In 2 cases in this report, a power Doppler ultrasound scan showed a significant increase in blood flow after contrast medium injection, which was not observed on a preoperative scan. Conclusion: Power Doppler ultrasound was found to be a simple, safe, and effective tool for real-time sialography monitoring.

Effects of Pelvic Compression Belt on The Thickness of Transversus Abdominis During Active Straight Leg Raising in Healthy Subjects (골반압박벨트가 정상인의 능동 하지직거상 시 복횡근 굵기에 미치는 영향)

  • Kim, Soo-Hyun;Pak, Mi-Hee;Sim, Jin-A;Lee, Kyung-A;Kim, Suhn-Yeop
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.17 no.1
    • /
    • pp.15-23
    • /
    • 2011
  • Background: The objective of this study was to determine the effectiveness of the pelvic compression belt (PCB) on the thickness of the transversus abdominis (TrA) during active straight leg raising (ASLR). Methods: Thirty healthy subjects (10 men and 20 women) volunteered to participate in this study. The thickness of TrA was measured using a real-time ultrasonic diagnostic imaging system. Subjects were instructed to rest in a resting (hook-lying) position and to perform ASLR with and without the PCB. The PCB was positioned below the anterior superior iliac spine with stabilizing pressure from elastic bands. Results: In the resting position and during ASLR, the thickness of the TrA significantly differed between subjects with and without PCB (p<.05). In addition, there was a significant interaction between the measurement position and the presence or absence of PCB (p<.05). Conclusions: These findings suggest that the PCB may affect deep core muscles such as TrA during various activities. Further studies are required to generalize the results of the present study.

  • PDF

The Potential Usefulness of Magnetic Resonance Guided Focused Ultrasound for Obsessive Compulsive Disorders

  • Jung, Hyun Ho;Chang, Won Seok;Kim, Se Joo;Kim, Chan-Hyung;Chang, Jin Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.4
    • /
    • pp.427-433
    • /
    • 2018
  • Obsessive compulsive disorder is a debilitating condition characterized by recurrent obsessive thoughts and compulsive reactions. A great portion of the obsessive compulsive disorder (OCD) patients are managed successfully with psychiatric treatment such as selective serotonin-reuptake inhibitor and cognitive behavioral psychotherapy, but more than 10% of patients are remained as non-responder who needs neurosurgical treatments. These patients are potential candidates for the neurosurgical management. There had been various kind of operation, lesioning such as leucotomy or cingulotomy or capsulotomy or limbic leucotomy, and with advent of stereotaxic approach and technical advances, deep brain stimulation was more chosen by neurosurgeon due to its characteristic of reversibility and adjustability. Gamma knife radiosurgery are also applied to make lesion targeting based on magnetic resonance (MR) imaging, but the complication of adverse radiation effect is not predictable. In the neurosurgical field, MR guided focused ultrasound has advantage of less invasiveness, real-time monitored procedure which is now growing to attempt to apply for various brain disorder. In this review, the neurosurgical treatment modalities for the treatment of OCD will be briefly reviewed and the current state of MR guided focused ultrasound for OCD will be suggested.