• Title/Summary/Keyword: Real-Time Monitoring

Search Result 3,593, Processing Time 0.039 seconds

Research on Light Application System for the Dynamic Moving Effect of The Design on Porcelain (도자기 표면의 문양을 역동적으로 움직이는 효과를 갖는 광응용 시스템연구)

  • Ryoo, Hee Soo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.11
    • /
    • pp.205-210
    • /
    • 2014
  • This is concerned with the technology to display the design on Porcelain and adjust malfunction for moving effect and light intensity by curator. More precisely, the technology makes it possible that the porcelain is connected to Light module which is the device for controlling light emission and rotating rolling plate, etc that are connected to LED light module, optical fiber and controller that is for scenario from the given storytelling. In addition, with a WiFi portable device (Smart-phone, other mobile device). equipped with a scenario programs, information for operation, failure and malfunction can be obtained and analyzed in real-time, and menu color and alarm is alerted when the displaying design is in abnormal status, which makes the early reactions to the status. Furthermore, the collected data can be sent through WiFi network to the device and PC managed by the curator specialized in managing the design on the Porcelain, thus the technology could help the curator who have less knowledge about moving pattern on the Porcelain. There is always a possibility of malfunction due to various condition that are caused by wring-harness when modules are wired-connected. In this research, in order to overcome this problem, we propose a system configuration that can do monitoring and diagnosis with a device for collecting data from LED control module, Light emission sensor and a personal WiFi device. Also, we performed connection between optical Fiber and LED and interlock for the system defined by the definition for information and storytelling scenario.

Characterizing Par ticle Matter on the Main Section of the Seoul Subway Line-2 and Developing Fine Particle Pollution Map (서울시 지하철 2호선 본선구간의 입자상물질 농도 특성 및 미세분진의 오염지도 개발)

  • Lee, Eun-Sun;Park, Min-Bin;Lee, Tae-Jung;Kim, Shin-Do;Park, Duck-Shin;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.2
    • /
    • pp.216-232
    • /
    • 2016
  • In present, the Seoul City is undergoing traffic congestion problems caused by rapid urbanization and population growth. Thus the City government has reorganized the mass transportation system since 2004 and the subway has become a very important means for public transit. Since the subway system is typically a closed environment, the indoor air quality issues have often raised by the public. Especially since a huge amount of PM (particulate matter) is emitted from ground tunnels passing through the subway train, it is now necessary to assess the characteristics and behaviors of fine PM inside the tunnel. In this study, the concentration patterns of $PM_1$, $PM_{2.5}$, and $PM_{10}$ in the Seoul subway line-2 were analyzed by real-time measurement during winter (Jan 13, 2015) and summer (Aug 7, 2015). The line-2 consisting of 51 stations is the most busy circular line in Seoul having the railway of 60.2 km length. The the one-day average $PM_{10}$ concentrations were $148{\mu}g/m^3$ in winter and $66.3{\mu}g/m^3$ in summer and $PM_{2.5}$ concentrations were $118{\mu}g/m^3$ and $58.5{\mu}g/m^3$, respectively. The $PM_{2.5}/PM_{10}$ ratio in the underground tunnel was lower than the outdoor ratio and also the ratio in summer is higher than in winter. Further the study examined structural types of underground subsections to explain the patterns of elevated PM concentrations in the line-2. The subsections showing high PM concentration have longer track, shorter curvature radius, and farther from the outdoor stations. We also estimated the outdoor PM concentrations near each station by a spatial statistical analysis using the $PM_{10}$ data obtained from the 40 Seoul Monitoring Sites, and further we calculated $PM_{2.5}/PM_{10}$ and $PM_1/PM_{10}$ mass ratios near the outdoor subway stations by using our observed outdoor $PM_1$, $PM_{2.5}$, and $PM_{10}$ data. Finally, we could develop pollution maps for outdoor $PM_1$ and $PM_{2.5}$ near the line-2 by using the kriging method in spatial analysis. This methodology may help to utilize existing $PM_{10}$ database when managing and control fine particle problems in Korea.

A-team Based Approach for Reactive Power/Voltage Control Considering Steady State Security Assessment (정태 안전성 평가를 고려한 무효전력 전압제어를 위한 A-team기반 접근법)

  • Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.2
    • /
    • pp.150-159
    • /
    • 1996
  • In this paper, an A-team(Asynchronous Team ) based approach for Reactive power and volage control considering static security assessment in a power system with infrastructural deficiencies is proposed. Reactive power and voltage control problem is the one of optimally establishing voltage level given several constraints such as reactive generation, voltage magnitude, line flow, and other switchable reactive power sources. It can be formulated as a mixed-integer linear programming(MILP) problem without deteriorating of solution accuracy to a certain extent. The security assessment is to estimate the relative robustness of the system in Its present state through the evaluation of data provided by security monitoring. Deterministic approach based on AC load flow calculations is adopted to assess the system security, especially voltage security. A security metric, as a standard of measurement for power system security, producting a set of discrete values rather than binary values, is employed. In order to analyze the above two problems, reactive power/voltage control problem and static security assessment problem, in an integrated fashion for real-time operations, a new organizational structure, called an A-team, is adopted. An A-team is an organization for agents which ale all autonomeus, work in parallel and communicate asynchronously, which is well-suited to the development of computer-based, multi-agent systems for operations. This A-team based approach, although it is still in the beginning stage, also has potential for handling other difficult power system problems.

  • PDF

An Efficient Feedback Collection for Multimedia Multicast (멀티미디어 멀티캐스트를 위한 효율적인 피드백 정보 수집)

  • Kung, Sang-Hwan;Kang, Min-Gyu;Koo, Yeon-Seol
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.3
    • /
    • pp.751-762
    • /
    • 1998
  • The purpose of this study is to enhance the quality of multimedia service under the heterogeneous end-terminals and network environment by monitoring the data receiving status of the group members regularly when the sender multicasts real-time multimedia data to a group. Especially, it focuses to reduce the total number of status information responded to the sender from the receivers. Accordingly. it upgrades the sender's performance by suppressing the number of status information packets generated by the receivers. The key idea of this study starts from how we profile the activity of all the members in a group. We assume that the receiver status in the worst status, so called primary receiver, represents the status of the whole group. This means that the whole group is assumed as being degraded in performance if the primary receiver is degraded, and that the whole group is assumed as being upgraded if the primary one is upgraded. In this algorithm, the primary receiver announces its status information to the whole group prior to other receivers, ana every receiver listening to the primary and other receivers' status compares its own status with them. Accordingly, any receiver may give up the status notification in case its status is not worse than others, resulting in the reduction of unnecessary responses to the sender.

  • PDF

Study on the Low Energy Sewage Management Based on Pre-sensing Technology and Automatic Blower Control (사전감지기술 및 송풍량 자동제어를 기반으로 한 저에너지 하수관리기술에 관한 연구)

  • Lee, Seungmyoung;Kim, Hanlae;Ki, Kyoungseo
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.6
    • /
    • pp.592-603
    • /
    • 2019
  • This study is about the implementation of low energy sewage management technology through effective control of blower which consumes the most energy in sewage treatment. In calculating the amount of oxygen required for microorganisms, unlike the existing method using the operating index in the bioreactor or TMS data in the discharge port, the CODcr and NH4+-N concentration changes in sewage flowing into the sewage treatment plant were detected in advance before entering the bioreactor and the amount of air was controlled based on this. The pre-sensing was found to have a high correlation compared with conventional products. As a result of blower control, it was possible to save about 9.9% energy more than the manual control. Consequently, this study suggested the possibility of blower's real-time control combined with pre-sensing technology. Also, it is expected that the low energy sewage treatment can be applied to sewage treatment facilities dependent on operation by manpower, and it will contribute to the reduction of greenhouse gas emissions.

A study on vulnerability analysis and incident response methodology based on the penetration test of the power plant's main control systems (발전소 주제어시스템 모의해킹을 통한 취약점 분석 및 침해사고 대응기법 연구)

  • Ko, Ho-Jun;Kim, Huy-Kang
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.24 no.2
    • /
    • pp.295-310
    • /
    • 2014
  • DCS (Distributed Control System), the main control system of power plants, is an automated system for enhancing operational efficiency by monitoring, tuning and real-time operation. DCS is becoming more intelligent and open systems as Information technology are evolving. In addition, there are a large amount of investment to enable proactive facility management, maintenance and risk management through the predictive diagnostics. However, new upcoming weaponized malware, such as Stuxnet designed for disrupting industrial control system(ICS), become new threat to the main control system of the power plant. Even though these systems are not connected with any other outside network. The main control systems used in the power plant usually have been used for more than 10 years. Also, this system requires the extremely high availability (rapid recovery and low failure frequency). Therefore, installing updates including security patches is not easy. Even more, in some cases, installing security updates can break the warranty by the vendor's policy. If DCS is exposed a potential vulnerability, serious concerns are to be expected. In this paper, we conduct the penetration test by using NESSUS, a general-purpose vulnerability scanner under the simulated environment configured with the Ovation version 1.5. From this result, we suggest a log analysis method to detect the security infringement and react the incident effectively.

The study of improving the performance of lower direction finding ability due to the interfered phase difference of circular array Antennas (원형배열안테나의 위상간섭에 의한 방향탐지 성능저하 개선연구)

  • Chung, Jae-Woo;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.535-539
    • /
    • 2010
  • This paper include to study DoA(Direction of Arrival) for radio collection and monitoring system. The direction finding calculated by applying the CVDF (Correlation Vector Direction Finding) algorithm for the five circular dipole antenna over V / UHF band. To improve the accuracy of direction finding by applying CVDF algorithm needs to obtain ideal phase difference each antennas. However, a circular array antenna phase difference pattern may be distorted on a specific frequency band or to particular direction. The effect of installing each array antennas circularly and the effect of the interference of center pole (located in the center of a circular array antenna mount) may make the distortion of phase pattern. If you use an active antenna instead of passive antenna to obtain good sensitivity, you would measure the more distortion. This paper propose how to change combination of antennas to measure the phase in real-time and how to use antenna beam patterns for minimizing the degradation phenomena at applying simple CVDF algorithm and increasing the direction finding capability.

  • PDF

ICT based Wireless Power Transmission System Development (ICT 기반의 무선전력전송 시스템 개발)

  • Lee, Jong-Hee;Bang, Junho;Chun, Hyun-Jun;Seo, Beom-Geun;Ryu, In-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.67-73
    • /
    • 2016
  • Recently, wireless power transmission has attracted much interest and is the subject of much research in industry and academia. As its name implies, it is a technology which involves transferring power without wires. This paper presents the design of an ICT-based wireless power transmission system. The proposed system consists of a wireless transceiver unit and high-efficiency coil unit, which can increase both the transmission efficiency and the effective power distance. In particular, the wireless transceiver unit was designed to work with the ICT technique to enable real-time remote monitoring. Also, studies were done relating to the effect of reducing the standby power. The optimal frequency of IGBT devices used in industrial wireless power systems of 20[KHz] was utilized. The values of $23.9[{\mu}H]$ and $2.64[{\mu}F]$ were selected for L and C, respectively, through many field experiments designed to optimize the system design. In addition, an output current controlling algorithm was developed for the purpose of reducing the standby power. The results presented in this paper represent a 75[%] to 85[%] higher power transmission efficiency with a 10[%] increase in the effective power transmission distance compared with the existing systems. As a result, the proposed system exhibits a lower standby power and maintenance costs. Also, the designed wireless transceiver unit facilitates fault detection by means of user acquired data with the development of the ICT applied program.

Development of Ubiquitous Sensor Network Intelligent Bridge System (유비쿼터스 센서 네트워크 기반 지능형 교량 시스템 개발)

  • Jo, Byung Wan;Park, Jung Hoon;Yoon, Kwang Won;Kim, Heoun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.1
    • /
    • pp.120-130
    • /
    • 2012
  • As long span and complex bridges are constructed often recently, safety estimation became a big issue. Various types of measuring instruments are installed in case of long span bridge. New wireless technologies for long span bridges such as sending information through a gateway at the field or sending it through cables by signal processing the sensing data are applied these days. However, The case of occurred accidents related to bridge in the world have been reported that serious accidents occur due to lack of real-time proactive, intelligent action based on recognition accidents. To solve this problem in this study, the idea of "communication among things", which is the basic method of RFID/USN technology, is applied to the bridge monitoring system. A sensor node module for USN based intelligent bridge system in which sensor are utilized on the bridge and communicates interactively to prevent accidents when it captures the alert signals and urgent events, sends RF wireless signal to the nearest traffic signal to block the traffic and prevent massive accidents, is designed and tested by performing TinyOS based middleware design and sensor test free Space trans-receiving distance.

A Neural Network-Based Tracking Method for the Estimation of Hazardous Gas Release Rate Using Sensor Network Data (센서네트워크 데이터를 이용하여 독성물질 누출속도를 예측하기 위한 신경망 기반의 역추적방법 연구)

  • So, Won;Shin, Dong-Il;Lee, Chang-Jun;Han, Chong-Hun;Yoon, En-Sup
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.38-41
    • /
    • 2008
  • In this research, we propose a new method for tracking the release rate using the concentration data obtained from the sensor. We used a sensor network that has already been set surrounding the area where hazardous gas releases can occur. From the real-time sensor data, we detected and analyzed releases of harmful materials and their concentrations. Based on the results, the release rate is estimated using the neural network. This model consists of 14 input variables (sensor data, material properties, process information, meteorological conditions) and one output (release rate). The dispersion model then performs the simulation of the expected dispersion consequence by combining the sensor data, GIS data and the diagnostic result of the source term. The result of this study will improve the safety-concerns of residents living next to storage facilities containing hazardous materials by providing the enhanced emergency response plan and monitoring system for toxic gas releases.

  • PDF