• 제목/요약/키워드: Real Time Measurement

검색결과 2,178건 처리시간 0.033초

엔트로피 개념에 의한 유량측정 기법 (Measurement of Discharge Using the Entropy Concept)

  • 추태호;이승관
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2006년도 춘계 종합학술대회 논문집
    • /
    • pp.342-346
    • /
    • 2006
  • 그 동안 기술적 또는 이론적 배경의 취약으로 인하여 측정이 매우 어렵거나 불가능했던 유량을 산정하는데 유효하게 적용할 수 있으며, 형상에 관계없이 측정비용 및 시간을 많이 줄일 수 있다. 더욱이 전자파 표면 유속계와 함께, 실시간 유입수문곡선을 만들 수 있는 실시간 유량 측정 시스템을 개발하는데 사용될 수 있다.

  • PDF

Measurement and Simulation of Wide-area Frequency in US Eastern Interconnected Power System

  • Kook, Kyung Soo;Liu, Yilu
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권3호
    • /
    • pp.472-477
    • /
    • 2013
  • An internet-based, real-time GPS synchronized wide-area power system frequency monitoring network(FNET) has been monitoring wide-area power system frequency in continuous time in the United States. This paper analyzes the FNET measurement to the verified disturbances in the US eastern interconnected power system and simulates it using the dynamic system model. By comparing the frequency measurements with its simulation results to the same disturbances in detail, this paper finds that the sequence of monitoring points to detect the frequency fluctuation caused by the disturbances is matched well in the measured data and the simulation results. The similarity comparison index is also proposed to quantify the similarity of the compared cases. The dynamic model based simulation result is expected to compensate for the lack of FNET measurement in its applications.

실시간 박테리아 감지를 위한 정전용량방식의 MEMS 바이오센서 (MEMS based capacitive biosensor for real time detection of bacterial growth)

  • 서혜경;임대호;임미화;김종백;신전수;김용준
    • 센서학회지
    • /
    • 제17권3호
    • /
    • pp.195-202
    • /
    • 2008
  • A biosensor based on the measurement of capacitance changes has been designed and fabricated for simple and realtime detection of bacteria. Compared to an impedance measurement technique, the capacitance measurement can make additional measurement circuits simpler, which improves a compatability for integration between the sensor and circuit. The fabricated sensor was characterized by detecting Escherichia coli(E. coli). The capacitance changes measured by the sensor were proportional to E. coli cell density, and the proposed sensor could detect $1{\times}10^6$ cfu/ml E. coli at least. The real-time detection was verified by measuring the capacitance every 20 minutes. After 7 hours of E. coli growth experiment, the capacitance of the sensor in the micro volume well with $4.5{\times}10^5$ cfu/ml of initial E. coli density increased by 20 pF, and that in another wells with $1.5{\times}10^6$ cfu/ml and $8.5{\times}10^7$ cfu/ml initial E. coli density increased by 56 pF and 71 pF, respectively. The proposed sensor has a possibility of the real-time detection for bacterial growth, and can detect E. coli cells with $1.8{\times}10^5$ cfu in nutrient broth in 5 hours.

일체형원자로에서 냉각재펌프의 전력측정을 이용한 실시간 유량산정 방법에 관한 연구 (The Study on a Real-time Flow-rate Calculation Method by the Measurement of Coolant Pump Power in an Integral Reactor)

  • 이준;윤주현;지성균
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.161-166
    • /
    • 2003
  • It is the common features of the integral reactors that the main components of the RCS are installed within the reactor vessel, and so there are no any flow pipes connecting the coolant pumps or steam generators. Due to no any flow pipes, it is impossible to measure the differential pressure at the RCS of the integral reactors, and it also makes impossible measure the flow-rate of the reactor coolant. As a alternative method, the method by the measurement of coolant pump power has been introduced in this study. Up to now, we did not found out a precedent which the coolant pump power is used for the real-time flow-rate calculation at normal operation of the commercial nuclear power plants. The objective of the study is to embody the real-time flow-rate calculation method by the measurement of coolant pump power in an integral reactor. As a result of the study, we could theoretically reason that the capacity-head curve and capacity-shaft power curve around the rated capacity with the high specific-speeded axial flow pumps have each diagonally steep incline but show the similar shape. Also, we could confirm the above theoretical reasoning from the measured result of the pump motor inputs, So, it has been concluded that it is possible to calculate the real-time flow-rate by the measurement of pump motor inputs. In addition, the compensation for a above new method can be made by HBM being now used in the commercial nuclear power plants.

  • PDF

이동 로봇의 실시간 자세 추정을 위한 센서 시스템의 개발 (Development of a Sensor System for Real-Time Posture Measurement of Mobile Robots)

  • 이상룡;권승만
    • 대한기계학회논문집
    • /
    • 제17권9호
    • /
    • pp.2191-2204
    • /
    • 1993
  • A sensor system has been developed to measure the posture(position and orientation) of mobile robots working in industrial environments. The proposed sensor system consists of a CCD camera, retro-reflective landmarks, a strobe unit and an image processing board. The proposed hardware system can be built in economic price compared to commercial vision systems. The system has the capability of measuring the posture of mobile robots within 60 msec when a 386 personal computer is used as the host computer. The experimental results demonstrated a remarkable performance of the proposed sensor system in the posture measurement of mobile robots - the average error in position is less than 3 mm and the average error in orientation is less than 1.5.

Real-Time Monitoring and Analysis of Power Systems with Synchronized Phasor Measurements

  • Kim, Hong-Rae
    • 조명전기설비학회논문지
    • /
    • 제21권9호
    • /
    • pp.101-108
    • /
    • 2007
  • State estimators are used to monitor the operating states of power systems in modern EMS. It iteratively calculates the voltage profile of the currently operating power system with voltage, current, and power measurements gathered from the entire system. All the measurements are usually assumed to be obtained simultaneously. It is practically impossible, however, to maintain the synchronism of the measurement data. Recently, phasor measurements synchronized via satellite are used for the operation of these power systems. This paper describes the modified state estimator used to support the processing of synchronized phasor measurements. Synchronized phasor measurements are found to provide synchronism of measurement data and improve the accuracy/redundancy of the measurement data for state estimation. The details of the developed state estimation program and some numerical results of operation are presented.

연삭가공 중인 피스톤 링 그루브의 실시간 연삭폭 측정법 개발 (Real-time measurement of the width of piston ring groove on the grinding process)

  • 김병창
    • 한국기계가공학회지
    • /
    • 제13권2호
    • /
    • pp.28-34
    • /
    • 2014
  • A non-contact type measurement system is specially devised to measure the width of a piston ring groove in the grinding process. This system comprises a line camera with an imaging lens, collimated white light source, and a one axis translation stage. When the measurement system movesalong the diagonal direction of the cylinder, the line camera captures an image. By analyzing such images, the width of the piston ring groove can be determined. The experimental results prove that the proposed system is useful, especially as a monitoring system in grinding piston ring grooves on cylinders with accuracy of several micrometers in an area of dozens of millimeters.

A Study of the Real-time Sensing by the Optical Current Sensor for GIS

  • Park, Won-Zoo;Kim, Yeong-Min
    • 조명전기설비학회논문지
    • /
    • 제23권7호
    • /
    • pp.75-80
    • /
    • 2009
  • In this study, a Web server was constructed using LabVIEW's DataSocket, which makes possible acquisition, analysis, and saving in real time. The output value of the optical current sensor at the web server PC was measured and the output value was displayed using the Web browser of the client PC. DataSocket by LabVIEW makes the construction of a Web server easier than other languages and is compatible with other application programs. An optical current sensor was composed using a 1310 [nm] laser diode, and 9/125 [${\mu}m$] standard single mode optical fiber and was created to be a close type sensor. Data measurement using Web servers has the advantage of monitoring electric power systems at a great distance and can fuse IT technology and electric power systems. Also, this measurement uses inexpensive mounting and programming when compared to existing measurement equipment allowing the construction of a measurement system in any situation or surrounding.

원심모형 실험기의 실시간 무선데이터 측정시스템 구축 (Development of real-time wireless data measurement technique on Centrifugal experiment)

  • 이종필;김유석;박진우
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.1289-1293
    • /
    • 2010
  • A slipring or FORJ are usually adopted in order for power supply of Geo-centrifuge and input/output data acquisition. Since using slipring causes quite a lot electrical noise, an optical communication using FORJ becomes more general for data acquisition. Such data acquisition devices, however, require frequent maintenance and replacement due to deterioration by long term usage. DICT has set up a real-time wireless date acquisition system using wireless communication technology instead of FORJ. The system enables a remote measurement at any inertial acceleration field up to 100g level and provides as same performance as FORJ. The priority of this system is to use a normal modem substituting a special FORJ.

  • PDF

Real-Time Measurement of Fry in the Cultivation Field Using a Line-Image Sensora

  • Ishimatsu, T.;Kawasue, K.;Kumon, T.;Ochiai, T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국제학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.822-825
    • /
    • 1988
  • In this paper, we present a system which enables a real-time measurement of the number and also the body length of the fry (baby fish) using a line image sensor. Here, we consider a situation that fry are transported from a pond to another, pond through a pipe. At one position of the pipe a transparent rectanglar channel is mounted. The images of the fry, which run through this rectanglar channel, are detected by a line image sensor. The image signals are digitized to binary ones and the contour of the fry are detected. After that, a real-time image analysis is executed with a digital signal processor. Labeling program analyses the connection of every pixel. The results are transfered to a personal computer and displayed on the online monitor graphically.

  • PDF