• Title/Summary/Keyword: Reading error

Search Result 120, Processing Time 0.022 seconds

The Effect of the Optical Points Difference between Finished-Reading Glasses and Dispensing Reading Glasses (완성품 돋보기와 조제가공된 돋보기가 광학적 요소에 미치는 영향)

  • Shim, Young-Cheol;Yoo, Gun-Chang;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.65-71
    • /
    • 2008
  • Purpose: This paper studied the effect of eyes on the comparison between the distance optical centers problem of dispensing reading glasses made by optician and finished reading glasses in the current market. Methods: The method of this study has been measured by eleven different categories from +1.00D to +4.00D. This study also separated into three groups by their optical frame size and measured optical center point (O.C) and optical center height (O.H) with 200 peoples of man and females over 40 years old without ocular disease living in Gwang-san gu, Gwang-Ju city. Results: As a result, optical center point ranged from 57 mm to 80 mm and it turned to be most common range is from 61 mm to 65 mm (64.6%). Moreover, the optical center height ranged from 1 mm to 8mm and most common ranged (23%) were 4 mm. In other words, finished reading glasses have irregular optical ranges. After observing 200 people who are over 40 years old men and women, result shows that more than 75.5% (151 people) currently use finished reading glasses. Survey of 151 people, most common error between the finished reading glasses's O.C and the wearers P.D were 4 mm (45%). Furthermore, the most common error between the finished reading glassses's O.H and the wearers O.H ranged from 3 mm to 4 mm. Astonishingly, the entire 151 people who wear finished reading glasses appeal that they feel tiredness on their eyes when they wear finished reading glasses. 53 people (35%) claimed that they feel tiredness on their eyes after 10 to 20 minutes wearing finished reading glasses. Base on the research, We conducted more experiment to find the value of prism of optical centers err because it will tell us whether the finished reading glasses are good enough to wear or not. We multiplied diopter by the difference between finished reading glasses's O.C. and wearer's P.D. Consequently, We found out that the finished reading glasses counter to the German RAL-RG 915 policy. And We also found that it is relative to the diopter of lenses. In conclusion, based on the researched that wearing finished reading glasses have a dangerous factor for our vision. Therefore optician must need to recommend correctly made dispensing reading glasses based on the optical center point.

  • PDF

Research on Improvement of Performance of Anemometer Using PTC Thermistor (PTC 서미스터를 이용한 유속계의 성능향상에 관한 연구)

  • Yoon, Joon-Yong;Cho, Nahm-Gyoo;Kim, Jin-Rae;Sung, Nak-Won;Kim, Hwang-Jin
    • The KSFM Journal of Fluid Machinery
    • /
    • v.3 no.4 s.9
    • /
    • pp.15-21
    • /
    • 2000
  • An anemometer employing the bulk PTC thermistor as the sensing element is investigated in this study. The numerical and experimental works are carried out to improve the sensitivity problem of the element by focusing fluid dynamics point of view. The typical shape of the sensing element has been used as a rectangular type, but this shape has a sensitivity problem because of flow separations on the sharp edge when the flow direction is different from that of the sensing element. In order to reduce the reading error, the installer has to be very careful about the flow direction. The reading error fluctuation by time as well as the sensitivity problem can be improved considerably through this study. It can be concluded that the small change of the sensor shape can improve the performance of the flow sensor.

  • PDF

A Study of Legibility by Monitor Letter Color with an Eye Tracker (아이트래커를 이용한 모니터 글자 색상에 따른 가독성에 대한 연구)

  • Kim, Ha-Rim;Kim, Soo-Hyun;Shin, Dong-Min;Jeong, Hee-Young;Kim, Young-Gil;Kim, Tae-Hong;Seo, Jae-Myoung;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.279-284
    • /
    • 2014
  • Purpose: This study will be a basic research providing data which can reduce eye strain using monitor and electric media by measuring legibility of text color on monitor. Methods: Total experimental subjects who don't have color anomaly and best corrected visual acuity was over 1.0 were 50 and their mean age was $22.83{\pm}1.47$. Reading speed test were carried out with 163 words and subjects who could read over 123 words were selected for legibility examination. Monitor background color was white and letter colors were black, blue, red, and yellow for the legibility examination. Results: In case of text color of black, blue, red, and yellow, Event duration(sec) was measured to 41.89, 42.89, 45.32, and 56.28, respevtively, and reading error (number) was measured to 1.94, 2.74, 3.36, and 5.14. Average of fixation duration(sec) was measured to 0.25, 0.26, 0.27, and 0.32. Conclusions: In this paper, event Duration, reading error and average of fixation duration which can measure the legibility was reduced in a sequence of black blue, red, and yellow.

A Reading Trainning Program offering Visual-Auditory Cue with Noise Cancellation Function (잡음제거 기능을 갖춘 시-청각 단서 제공 읽기 훈련 프로그램)

  • Bang, D.H.;Kang, H.D.;Kil, S.K.;Lee, S.M.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.2 no.1
    • /
    • pp.35-43
    • /
    • 2009
  • In this paper, we introduce a reading training program offering visual-auditory cue with noise cancellation function (RT program) developed by us. The RT program provides some training sentences with visual-auditory cues. Motor speech disorder patients can use the visual and/or auditory cues for reading training. To provide convenient estimation of training result, we developed a noise cancellation algorithm. The function of the algorithm is to remove noise and auditory-cues which are recorded with reading speech at the same time while patient read the sentences in PC monitor. In addition, we developed a function for finding out the first starting time of reading sound after a patient sees a sentence and begins to read the sentence. The recorded speeches are acquired from six people(three male, three female) in four noisy environments (interior noise, white noise, car interior noise, babble noise). We evaluated the timing error for starting time between original recorded speech and processed speech in condition of executing noise cancellation function and not executing. The timing error was improved as much as $4.847{\pm}2.4235[ms]$ as the effect of noise cancellation. It is expected that the developed RT program helps motor speech disorder patient in reading training and symptom evaluation.

  • PDF

Study of Reading Aids for Improve Text Readability on a Small Screen Mobile Device (Small Screen Mobile 환경에서 가독성을 높이기 위한 Reading Aids의 연구)

  • Kim, Jong-Gon;Choi, Sun-Hyang;Min, Young-Sam
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.147-151
    • /
    • 2008
  • There are many attempts to transfer many applications from PC to mobile which has small screen, cause of a development of mobile technology. To display the whole information of the PC on the tiny screen, it makes many Horizontal Scroll, Horizontal Scroll in mobile screen makes people to miss where they are reading easily and such a frequent error makes readability of the information in mobile screen low. We suggest a Line Marker to help readability of the mobile screen high. This study shows the relationship between the conditions of Line Marker such as fixed or moved or not exists and the factors of the reading time and satisfaction.

  • PDF

Automatic Piped Water Meter Reading System Based on IEEE 802.15.4 Protocol (IEEE 802.15.4 Protocol 기반 원격 수도검침 System)

  • Seon, Yong-Ju;Lee, Ho-Eung;Park, Soo-Jin;Park, Hyun-Ju
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.304-308
    • /
    • 2008
  • In this paper, we present measurement method of the amount of used piped water and the communications environment for automatic piped water meter reading. The existing piped water meter reading which is carried out by the human in person by monitoring the amount of use and recording make the problem of an error of the figure and being short of staffed to carry out piped water meter reading. To solve the existing problem in this paper, the amount of used piped water is converted into data type by Photo Interrupt Sensor, and IEEE 802.15.4 Protocol is used to confirm the measurement in remote place.

  • PDF

Fault-tolerant ZigBee-based Automatic Meter Reading Infrastructure

  • Hwang, Kwang-Il
    • Journal of Information Processing Systems
    • /
    • v.5 no.4
    • /
    • pp.221-228
    • /
    • 2009
  • Due to low cost, low-power, and scalability, ZigBee is considered an efficient wireless AMR infrastructure. However, these characteristics of ZigBee can make the devices more vulnerable to unexpected error environments. In this paper, a fault-tolerant wireless AMR network (FWAMR) is proposed, which is designed to improve the robustness of the conventional ZigBee-based AMR systems by coping well with dynamic error environments. The experimental results demonstrate that the FWAMR is considerably fault-tolerant compared with the conventional ZigBee-based AMR network.

The Effect of Color Filter on the Reading Ability in Teenager with Irlen-Syndrome (얼렌증후군에서 컬러필터가 읽기능력에 미치는 영향)

  • Lee, Dong-Joon;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.125-136
    • /
    • 2013
  • Purpose: The aim of this study was to investigate the effect of improving read speed with color filter or without color filter to improve reading disorder of teenager who were diagnosed as Meares-Irlen syndrome through survey inspection with Meares-Irlen syndrome visual stress (MISViS) score. Methods: MISViS subjects were selected from screening survey MISViS results given above 2.13 in the clinical criteria scores (MISViS score). Reading speed were measured quickly and efficiently the rate of reading via test in which randomly ordered common words are read aloud during a minute. Each of the subjects were worn a filter of the lowest concentration in each color filter group composed of 15 groups. Results: MISViS score of MISViS group and control group were 2.57 and 0.66, respectively. Results of reading speed with filter and without filter in MISViS group were $102.27{\pm}27.86$ wpm and $118.87{\pm}26.99$ wpm (p=0.001), respectively, as well as were $132.93{\pm}6.88$ wpm and $133.43{\pm}6.64$ wpm (p=0.131) in the normal group. Associated with error changes with filter and without filter between two groups, skipping in MISViS Group were from $0.25{\pm}0.62$ times to 0 times (p=0.191), Errors were from $1.83{\pm}1.69$ times to $0.17{\pm}0.38$ times (p = 0.004) and, repetitions were 0. skipping in control group were 0 times, errors were from $0.21{\pm}0.43$ times to $0.07{\pm}0.27$ times (p=0.336) and, repetitions were from $0.14{\pm}0.36$ times to 0 (p=0.165). The filter of blue series chosen in MISViS group had higher percentage (40%), whereas, subjects in normal group were more likely to prefer the filter of gray color (29%). Conclusions: This study showed that MISViS score have been used as a significant diagnosis for Irlen syndrome screening. This study found that wearing suitable color filter for MISViS patients were useful to improve learning with regard to reading. Unique color filter selection for MISViS subjects must be carefully considered since fit color filter are different personally.

Development of a Reading Training Software offering Visual-Auditory Cue for Patients with Motor Speech Disorder (말운동장애인을 위한 시-청각 단서 제공 읽기 훈련 프로그램 개발)

  • Bang, D.H.;Jeon, Y.Y.;Yang, D.G.;Kil, S.K.;Kwon, M.S.;Lee, S.M.
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.4
    • /
    • pp.307-315
    • /
    • 2008
  • In this paper, we developed a visual-auditory cue software for reading training of motor speech disorder patients. Motor speech disorder patients can use the visual and/or auditory cues for reading training and improving their symptom. The software provides some sentences with visual-auditory cues. Our sentences used for reading training are adequately comprised on modulation training according to a professional advice in speech therapy field. To ameliorate reading skills we developed two algorithms, first one is automatically searching the starting time of speech spoken by patients and the other one is removing auditory-cue from the recorded speech that recorded at the same time. The searching of speech starting time was experimented by 10 sentences per 6 subjects in four kinds of noisy environments thus the results is that $7.042{\pm}8.99[ms]$ error was detected. The experiment of the cancellation algorithm of auditory-cue was executed from 6 subjects with 1 syllable speech. The result takes improved the speech recognition rate $25{\pm}9.547[%]$ between before and after cancellation of auditory-cue in speech. User satisfaction index of the developed program was estimated as good.

The Influence of Eccentric Error in Horizontal Angle Measurement (수평각관측에 있어서 구심오차가 관측치에 미치는 영향)

  • 이계학
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.9 no.1
    • /
    • pp.55-61
    • /
    • 1991
  • The accidential errors of horizontal angles are influenced by sighting, reading and eccentric errors etc. This paper deals with the influence of eccentric error by the formula of theory and evaluation, and actually testing measurement. The results show that the eccentric error is calculated through the sighting distance, observed angle, eccentric distance and angle. And then, three repeating method is of practical use, and also, eccentric error is able to evaluate through the sighting distance and observed angle in according to performance of each instrument.

  • PDF