• Title/Summary/Keyword: Reactive System

Search Result 2,076, Processing Time 0.032 seconds

New VFT Grid-Connection System Including Reactive Power Compensation (무효전력 보상을 포함하는 새로운 회전형 변압기 계통 연계 시스템)

  • Oh, Jeong-Sik;Park, Tae-Sik;Kim, Sung-Hwan;Kwak, No-Hong;Park, Jang-Hyun
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.143-150
    • /
    • 2019
  • The back-to-back HVDC asynchronous grid interconnect technology has problems of high harmonic generation, high cost, and low scalability. To solve this problem, research on asynchronous grid interconnect technology using VFT is actively being conducted. However, the reactive power due to the inductance component of the VFT is generated, and the problem of additional installation of the reactive power compensating facility is inevitably generated. Therefore, in this paper, we aim to solve the reactive power compensation problem of existing VFT by designing rectifier AC-DC converter, which is an essential element of the asynchronous grid connection system using VFT, to compensate reactive power as well as active power supply. The performance was verified through simulation.

A BIFUNCTIONAL UTILITY CONNECTED PHOTOVOLTAIC SYSTEM WITH POWER FACTOR CORRECTION AND U.P.S. FACILITY

  • Kim. S.;Yoo, Gwonjong;Song, Jinsoo
    • Proceedings of the KIPE Conference
    • /
    • 1996.06a
    • /
    • pp.103-108
    • /
    • 1996
  • In this paper, a novel utility connected photovoltaic power generation system with unity power factor and uninterruptable power system facility and its control strategy are proposed. The proposed photovoltaic(PV) system is connected in parallel between utility and load. The PV system provides an uninterruptable voltage to load, a maximum power tracking to solar array, and power factor correction to the utility. The proposed system has the following advantages compared with the conventional utility connected PV system. 1. Harmonic elimination Function 2. Feeding the photovoltaic energy to the utility 3. Providing the uninterruptible power source along battery to the load In case that the photovoltaic array system is on the poor power generation, the battery and capacitor of the PV system are charged by three phase utility source and the inverter in the PV system only provides the reactive current to eliminate the harmonic current exited on the utility. In the normal operation mode, the PV system supplies active power to load and reactive power to utility in order to maintain the unity power factor and to regulate ac load voltage.

  • PDF

Transfer Capability Enhancement Using Voltage Source Converter HVDC (전압원 HVDC를 이용한 부하집중지로의 송전용량 증대방안)

  • Oh, Sea-Seung;Jang, Gil-Soo;Cha, Jun-Min
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.328-330
    • /
    • 2005
  • This paper presents a transfer capability enhancement of using VSC HVDC system which can control reactive power as well as active power. The transfer capability is constrained by stability like voltage stability. These constraints may relieved by reactive power control ability of the VSC HVDC system. Site selection algorithm is also proposed.

  • PDF

New Sensorless Control of PMSM using Reactive Power (무효전력을 이용한 영구자석 동기전동기의 새로운 센서리스 제어)

  • Han, Yoon-Seok;Choi, Jung-Soo;Kim, Young-Seok;Shin, Jae-Wha
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.237-239
    • /
    • 2001
  • This paper presents a new speed sensorless control method of permanent magnet synchronous motors based on instantaneous reactive power. The proposed system is constructed in a synchronously rotating reference frame and is very simple. The new approach is not dependent upon the stator resistance, nor is it affected by mechanical motor parameters. The effectiveness of the proposed system is confirmed by the simulation results.

  • PDF

A Study of the Optimal Condenser Operation in Distribution System (배전선로의 적정 콘덴서 운용 연구)

  • Jeon, Young-Soo;Jang, Jeong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1238-1240
    • /
    • 1998
  • For economic operating of distribution system, utility has to minimize the loss in distribution line by controlling reactive power and power factor. This paper presents calculation of reactive power in distribution line, estimation of the condenser capacity according to distance, and computation of optimal location and proper condenser capacity.

  • PDF

Pharmacological Action and Toxicity of Rehmannia glutinosa (숙지황(Rehmannia glutinosa)의 약리작용과 독성)

  • Park, Yeong-Chul;Lee, Gi-Yong;Baek, Lag-Min;Son, Hye-Young;Kook, Yoon-Boom;Lee, Sun-Dong
    • Herbal Formula Science
    • /
    • v.19 no.1
    • /
    • pp.145-160
    • /
    • 2011
  • Objectives : Rehmannia glutinosa has been used extensively in Korean traditional medicine. Although thorough clinical trials are lacking, Various pharmacological actions for Rehmannia glutinosa has been identified newly using animal models. In addition, it was reported that reactive intermediates, potentially causing toxic effects, was isolated from one of components in Rehmannia glutinosa. In this article, it is purposed for explanation and introduction of new studies for Rehmannia glutinosa in terms of pharmacological action and toxicology. Methods : New studies for Rehmannia glutinosa were reviewed and summarized in terms of pharmacological action and toxicity. Results and Conclusions : Rhmannia glutinosa and its components including iridoids, saccharides, as well as amino acid, showed a variety of pharmacological actions on the blood system, immune system, endocrine system, cardiovascular system and the nervous system. In addition, it was identified that aucubin, one of major components of Rhmannia glutinosa was biotransformed to reactive intermediates by ${\beta}$-glycosidase and acid-hydrolysis, resulting in forming aucubigenin- albumin adduct. Even if a lot of new pharmacological actions has been identified, it should be considered for Rhmannia glutinosa to contain the material producing reactive intermediates which may induce the side effects.

Optimal Voltage and Reactive Power Scheduling for Saving Electric Charges using Dynamic Programming with a Heuristic Search Approach

  • Jeong, Ki-Seok;Chung, Jong-Duk
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.329-337
    • /
    • 2016
  • With the increasing deployment of distributed generators in the distribution system, a very large search space is required when dynamic programming (DP) is applied for the optimized dispatch schedules of voltage and reactive power controllers such as on-load tap changers, distributed generators, and shunt capacitors. This study proposes a new optimal voltage and reactive power scheduling method based on dynamic programming with a heuristic searching space reduction approach to reduce the computational burden. This algorithm is designed to determine optimum dispatch schedules based on power system day-ahead scheduling, with new control objectives that consider the reduction of active power losses and maintain the receiving power factor. In this work, to reduce the computational burden, an advanced voltage sensitivity index (AVSI) is adopted to reduce the number of load-flow calculations by estimating bus voltages. Moreover, the accumulated switching operation number up to the current stage is applied prior to the load-flow calculation module. The computational burden can be greatly reduced by using dynamic programming. Case studies were conducted using the IEEE 30-bus test systems and the simulation results indicate that the proposed method is more effective in terms of saving electric charges and improving the voltage profile than loss minimization.

Coordinated Voltage and Reactive Power Control Strategy with Distributed Generator for Improving the Operational Efficiency

  • Jeong, Ki-Seok;Lee, Hyun-Chul;Baek, Young-Sik;Park, Ji-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1261-1268
    • /
    • 2013
  • This study proposes a voltage and reactive coordinative control strategy with distributed generator (DG) in a distribution power system. The aim is to determine the optimum dispatch schedules for an on-load tap changer (OLTC), distributed generator settings and all shunt capacitor switching on the load and DG generation profile in a day. The proposed method minimizes the real power losses and improves the voltage profile using squared deviations of bus voltages. The results indicate that the proposed method reduces the real losses and voltage fluctuations and improve receiving power factor. This paper proposes coordinated voltage and reactive power control methods that adjust optimal control values of capacitor banks, OLTC, and the AVR of DGs by using a voltage sensitivity factor (VSF) and dynamic programming (DP) with branch-and-bound (B&B) method. To avoid the computational burden, we try to limit the possible states to 24 stages by using a flexible searching space at each stage. Finally, we will show the effectiveness of the proposed method by using operational cost of real power losses and voltage deviation factor as evaluation index for a whole day in a power system with distributed generators.

A Study for burning behavior of Hydro-Reactive metal fuel using Ultrasound (초음파를 이용한 해수반응 연료의 연소거동 고찰 연구)

  • Seo, Mu-Kyung;Kang, To;Cho, Seung-Wan;Kim, Hak-Joon;Song, Sung-Jin;Kim, Jun-Hyung;Yoo, Ji-Chang;Jung, Jung-Yong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.451-454
    • /
    • 2011
  • Hydro-Reactive metal Fuel (HRF) which has more fuel than general solid propellant reducing oxidizing agent is suitable for ultrahigh speed rocket motor in the water. However, burning rate of HRF has not been studied yet. Through the earlier studies, we established ultrasonics measurement system measuring burning rate of solid propellant as a function of pressure in a single test and verified its reliability. In this paper, we will measure burning rate of HRF using ultrasound with previous development measurement system.

  • PDF

Synthesis and Application for Hydrophilic Polyurethane of Non-swelling Type (Non-swelling type의 Hydrophilic polyurethane 합성 및 응용에 관한 연구)

  • Yang, Jeong-Han;Jeon, Jae-Woo;Yeum, Jeong-Hyun;Kim, Duck-Han;Oh, Kyoung-Suk;Yoon, Nam-Sik
    • Textile Coloration and Finishing
    • /
    • v.23 no.2
    • /
    • pp.118-130
    • /
    • 2011
  • In this study, hydrophilic polyurethane (PU) was synthesized by one shot process to get good non-swelling effect and to keep high breathability using reactive silicone oil of mono terminal and bi-terminal types. We also blended non reactive silicone oil with pure hydrophilic PU to compare non-swelling effect and breathability with hydrophilic PU synthesized by the two types of reactive silicone oils. The hydrophilic films were analyzed by nuclear magnetic resonance (NMR) spectroscopy, scanning electron microscope (SEM), Fourier transform infrared (FT-IR) spectroscopy, X-ray photo electron (XPS) spectroscopy, energy dispersive spectrometry (EDS), breathability, waterproofness, tensile strength, contact angle and swelling effect. The results showed that the film made by hydrophilic PU which was synthesized with mono terminal type silicone oil provided good non-swelling effect and acceptable moisture permeability due to the modified surface properties.