• Title/Summary/Keyword: Reaction parameter

Search Result 478, Processing Time 0.029 seconds

Diagnostic Value of Early Inflammatory Reaction in Postoperative Infection of the Lumbar Spine

  • Mun, Ji-Hun;Kim, Dong-Hyun;Ryu, Kyeong-Sik;Park, Chun-Kun;Kim, Moon-Chan
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.3
    • /
    • pp.206-210
    • /
    • 2005
  • Objective : Our aim is to evaluate the early changes of biologic markers such as white blood cell[WBC] count, erythrocyte sedimentation rate[ESR] and C-reactive protein[CRP] in early diagnosis of postoperative infection and to differentiate infection from inflammatory reaction in lumbar spine surgery. Methods : We reviewed 330patients who had undergone spinal operations between May 1999 and October 2001. For this study, the patients were classified into two groups, which include a group that underwent spinal decompressive surgery without instrumentation[SD], and the other group that underwent fusion surgery with spinal instrumentation[SI]. And each group was also subdivided into two groups respectively, one with infection and the other without infection. We retrospectively analyzed the WBC count, ESR and CRP preoperatively and postoperatively, according to their operation type and postoperative infection history. Results : Inflammatory indices were physiologically affected by instrumentation itself. But ESR and CRP elevations were more prolonged and sustained under infection. In SD patients without infection, ESR and CRP were stabilized 5 days after surgery. In SI patients without infection, CRP was stabilized about 7days after surgery, but ESR showed sustained and variously elevated. In both SD and SI groups, the stabilization of CRP was the most reliable behavior of surgery without infection. Conclusion : C-reactive protein is most sensitive parameter for postoperative spine infection. The knowledge of the inflammatory indices and their relatively uniform patterns with or without infection offers surgeons the ability to infer the state of surgical wound.

Application of Dynamic Reaction Cell - Inductively Coupled Plasma Mass Spectrometry for the Determination of Calcium by Isotope Dilution Method (반응셀 유도결합플라스마 질량분석분석기를 이용한 칼슘 동위원소비율의 측정과 동위원소희석법의 적용)

  • Suh, Jungkee;Yim, Yonghyeon;Hwang, Euijin;Lee, Sanghak
    • Analytical Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.417-426
    • /
    • 2002
  • Inductively Coupled Plasma Dynamic Reaction Cell Quadrupole Mass Spectrometry (ICP-DRC-QMS) was characterized for the detection of the six naturally occurring calcium isotopes. The effect of the operating conditions of the DRC system was studied to get the best signal-to-noise ratio. This experiment shows that the potentially interfering ions such as $Ar^+$, ${CO_2}^+$, ${NO_2}^+$, $CNO^+$ at the calcium masses m/z 40, 42, 43, 44 and 48 were removed by flowing $NH_3$ gas at the rate of 0.7 mL/min $NH_3$ as reactive cell gas in the DRC with a RPq value (rejection parameter) of 0.6. The limits of detection for $^{40}Ca$, $^{42}Ca$, $^{43}Ca$, $^{44}Ca$, and $^{48}Ca$ were 1, 29, 169, 34, and 15 pg/mL, respectively. This method was applied to the determination of calcium in synthetic food digest samples (CCQM-P13) provided by LGC for international comparison. The isotope dilution method was used for the determination of calcium in the samples. The uncertainty evaluation was performed according to the ISO/GUM and EURACHEM guidelines. The determined mean concentration and its expanded uncertainty of calcium was ($66.4{\pm}1.2$) mg/kg. In order to assess our method, two reference samples, Riverine Water reference sample (NRCC SLRS-3) and Trace Elements in Water reference sample (NIST SRM 1643d), were analyzed.

Analysis Program for Diffusion Model: SNUDM (확산모형 분석도구: SNUDM)

  • Koh, Sungryong;Choo, Hyeree;Lee, Dajung
    • Korean Journal of Cognitive Science
    • /
    • v.31 no.1
    • /
    • pp.1-23
    • /
    • 2020
  • This paper introduces SNUDM, an analysis program for Ratcliff's diffusion model, which has been one of the most important models in cognitive psychology over the past 35 years and which has come to occupy an important place in cognitive neuroscience in recent years. The analysis tool is designed with the basic principles of easy comprehension and simplicity in use. A diffusion process was programmed as the limit of a simple random walk in a manner resembling Ratcliff & Tuerlinckx(2002). The response time distribution of the model was constructed by simulating the time taken by a random walk until it reaches a threshold with small steps. The optimal parameter values in the model are found to be the smallest value of the chi-square values obtained by comparing the resulting distribution and the experimental data using Simplex method. For simplicity and ease of use, the input file used here is created as a file containing the quantile of the reaction time, the trials and other information. The number of participants and the number of conditions required for such work programs are given in a way that answers the question. Using this analysis tool, the experimental data of Ratcliff, Gomez, & McKoon(2004) were analyzed. We found the very similar pattern of parameter values to Ratcliff et al.(2004) found. When comparing DMAT, fast-dm and SNUDM with the generated data, we found that when the number of trials is small, SNUDM estimates the boundary parameter to a value similar to fast-dm and less than the DMAT. In addition, when the number of trials was large, it was confirmed that all three tools estimate parameters similarly.

Mass transfer Characteristic during Osmotic Dehydration of Ginger and Its Effect on Quality (생강 삼투압 건조 시 물질이동 특성과 품질에 미치는 효과)

  • Kim, Myung-Hwan
    • Applied Biological Chemistry
    • /
    • v.41 no.5
    • /
    • pp.372-376
    • /
    • 1998
  • Internal mass transfer during osmotic dehydration of gingers in sugar solution was examined as a function of concentration, temperature and immersion time of those solutions using moisture loss, sugar gain, molality and rate parameter. Influence of osmotic dehydration on browning reaction and texture properties of air dried rehydrated was also evaluated. Increasing the concentration and temperature of sugar solutions increased moisture loss, sugar gain, molality and rate parameter. Water loss and sugar gain were rapid in the first 3 min and then changed gentle slope. Moisture loss during osmotic dehydration using a sugar solution $(60\;Brix,\;80^{\circ}C)$ with 18 min immersion time was 40.05 g moisture/100 g wet ginger which was 52% reduction of initial moisture content in ginger (83.02%, wet basis). The changes of rate parameter were more affected by temperature than by concentration of sugar solution. Minimum browning degree (O.D.=0.027) was carried out by osmotic dehydration in sugar solution $(40\;or\;50\;Brix,\;80^{\circ}C)$ with 15 min immersion time compared to control (O.D.=0.132). Influence of osmotic dehydration on puncture forces of 3 min rehydrated ginger in boiling water were $22{\sim}34%$ of reduction, while blanching treatment had not affected compared to those of control.

  • PDF

Effects of Imperfect Fixing at the Active End of Spring-top Resonant Column Apparatus (주동단에 반력으프링이 부착된 공진우 시험기에서 우동단 불완전 고정의 영향)

  • 민덕기
    • Geotechnical Engineering
    • /
    • v.6 no.1
    • /
    • pp.7-14
    • /
    • 1990
  • The two degree of freedom model is proposed to study the effects of imperfect fixing at the active end of spring-top resonant column apparatus. A computer program using the SYMPHONY spreadsheet is developed to calculate the dimensionless frequency, F, from which modulug can be determined. It is found that the effect of reaction mass through the parameter Tr on dimensionless frequency, F, can not be ignored if Tr$\leq$20. As To increases, the variation of F increases. But for Tr$\geq$ 20, the effect of To becomes small. It is recommended that T. be greater than 20 if single degree of freedom model is rosed to determine modulus of soil. It also is found that damping ratios of specimen and apparatus do not strongly affect the dimensionless frequency, F.

  • PDF

Preparation of $Fe_{3-x}Mn_{x}O_4$ Films by the Ferrite Plating and its Magnetic Properties (Ferrite plating 방법에 의한 $Fe_{3-x}Mn_{x}O_4$ 박막 제작과 자기적 성질)

  • 하태욱;이정식
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.3
    • /
    • pp.145-150
    • /
    • 1996
  • The magnetic thin films can be prepared without vacuum process and under the low temperature ( < $100^{\circ}C$) by ferrite plating. We have performed ferrite plating of $Fe_{3-x}Mn_{x}O_4(x=0.0~0.023)$ films on glass plate at $80^{\circ}C$. We got the film $9000\AA$ in thickness, having a mirror-like luster. The composition parameter, x, in the $Fe_{3-x}Mn_{x}O_4$ films is much smaller then the corresponding on, x', in the reaction solution(x/x'=O.04). The saturation magnetization($M_{s}$) of $Fe_{3}O_{4}$ ferrite film as measured by a VSM was $M_{s}$=480 emu/cc which agrees with $Fe_{3}O_{4}$ bulk samples.

  • PDF

Thrust Analysis and Experiments on Low-Speed Single-Sided Linear Induction Motor

  • Jeong, Jae-Hoon;Choi, Jang-Young;Sung, So-Young;Park, Jong-Won;Lim, Jaewon
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.230-235
    • /
    • 2017
  • When the characteristics of a linear induction motor (LIM) are analyzed using finite element analysis (FEA), it is desirable to set the voltage source as an input. If the voltage source is set as an input in FEA, the leakage inductance and primary resistance of the equivalent circuit must be entered by direct calculation, and the magnetizing inductance and secondary reaction effects are directly considered in FEA. Exact calculation is necessary because the primary winding resistance and leakage inductance directly entered will have a significant effect on the LIM output. Therefore, in this study, we accurately calculated the primary leakage inductance and analyzed the resulting LIM characteristics. We calculated the leakage inductance using an analytical equation and FEA, and we confirmed the accuracy by comparing the results with the value experimentally calculated using a manufactured model. We also analyzed the instrument performance and thrust of the LIM as a function of the difference in the leakage inductance. Finally, we present the conclusions on the precise analysis based on the calculation of the leakage inductance.

Synthesis of Boron-Nitride Film by Plasma Assisted Chemical Vapor Deposition Using $BCl3-NH3-Ar$ Mixed Gas ($BCl3-NH3-Ar$계의 플라즈마화학증착공정을 이용한 질화붕소막의 합성)

  • 박범수;백영준;은광용
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.3
    • /
    • pp.249-256
    • /
    • 1997
  • The effect of process parameter of plasma assisted chemical vapor deposition (PACVD) on the variation of the ratio between cubic boron nitride (c-BN) and hexagonal boron nitride (h-BN) in the film was in-vestigated. The plasma was generated by electric power with the frequency between 100 and 500 KHz. BCl3 and NH3 were used as a boron and nitrogen source respectively and Ar and hydrogen were added as a car-rier gas. Films were composed of h-BN and c-BN and its ratio varied with the magnitude of process parameters, voltage of the electric power, substrate bias voltage, reaction pressure, gas composition, sub-strate temperature. TEM observation showed that h-BN phase was amorphous while crystalline c-BN par-ticle was imbedded in h-BN matrix in the case of c-BN and h-BN mixed film.

  • PDF

A Study on the Design of Flexible Display Considering the Failure Characteristics of ITO Layer (플렉시블 디스플레이에서 ITO층의 파괴 특성을 고려한 설계연구)

  • Kim, Min Gyu;Park, Sang Baek;Chae, Soo-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.5
    • /
    • pp.552-558
    • /
    • 2013
  • In recent years the interest on flexible display has been increasing as a future display due to its bendable characteristics. An ITO(indium tin oxide) layer, which is part of a flexible display, can be broken easily while bending because it is made of brittle materials. This brittle property can cause the malfunction of flexible display. To analyze fracture characteristics of ITO layer, bending test was conducted commonly. However, it is not possible to know specific phenomena on bended ITO layer by simple bending test only. Accordingly, in this study, the FE(finite element) model is developed similarly to a real flexible display to analyze stress distribution of flexible display under bending condition, especially on ITO layer. To validate FE model, actual bending test was conducted and the test results were compared with the simulation results by measuring reaction forces during bending. By using the developed model, FE analysis about the effect of design parameter (Thickness & Young's Modulus of BL) on ITO Layer was performed. By explained FE analysis above, this research draws a conclusion of reliable design guide of flexible display, especially on ITO layer.

Study on the Adhesive Strength by the Manufacturing Process Parameter of the Aluminum Pouch for Secondary Battery (이차전지용 알루미늄 파우치 필름의 제조 공정 변수에 따른 접착력에 대한 연구)

  • Yu, Min Sook;Kim, Do Hyun;Cho, Jung Min;Bae, Sung Woo;Kim, Dong Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.2
    • /
    • pp.149-155
    • /
    • 2016
  • In this study, we investigated the adhesive strength by molecular weight, mixture ratio, coating thickness, lamination temperature and aging condition of adhesive in manufacture process of Nylon-Aluminum for secondary aluminum pouch. It found that as the molecular weight of adhesive gets lower, the adhesive strength increases. In the mixture ratio, as the content of hardener get higher and as the content of solvent get lower, the adhesive strength increases. Also, as the coating thickness of adhesive get thicker, the adhesive strength increase. In addition, the adhesive strength is higher at 90 degrees of lamination temperature. So, it found that 90 degrees of lamination temperature is appropriate. In the aging condition when aged for 5 days, it found that the reaction and curing of adhesive is sufficient by measuring the adhesive strength.