• 제목/요약/키워드: Reactance Effect

검색결과 56건 처리시간 0.027초

권선형 유도발전기 CVCF를 위한 2차 여자제어법에 관한 연구 (II) (A Study on the 2nd Excitation Method for CVCF Generation of Doubly-fed Induction Generator (II))

  • 안진우;황영문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.45-48
    • /
    • 1990
  • This paper deals with the control strategy for constant voltage, constant frequency (CVCF) generation of doubly-fed Induction generator. As induction machine is a nonlinear and multivariable machine, so, the influential factors for CVCF generation of induction generator are the magnitude of output voltage, load current and its power factor, slip of the machine, etc. To get appropriate control scheme and to research the effect of its parameters, the control equation of induction machine is derived and tested. The derived condition is very useful for the CVCF control of the machine and for determing the characteristics of the system. The simulation results show that magnetizing reactance and rotor resistance is a very important parameter in this control system.

  • PDF

Input Current Characteristics of a Three-Phase Diode Rectifier with Capacitive Filter Under Line Voltage Unbalance Condition

  • Jeong Seung-Gi;Lee Dong-Ki;Park Ki-Won
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.808-815
    • /
    • 2001
  • The three-phase diode rectifier with a capacitive filter is highly sensitive to line voltage unbalance, and may cause significantly unbalanced line currents even under slightly unbalanced voltage condition. This paper presents an analysis of this 'unbalance amplification' effect for an ideal rectifier circuit without ac-and dc-side inductors. The voltage unbalance is modeled by introducing a deviation voltage superimposed on balanced three-phase line voltages. With proper approximations, closed-form expressions for symmetrical components of the line current and current unbalance factor are derived in terms of the voltage unbalance factor, filter reactance, and load current. The validity of analytical predictions is confirmed by simulation.

  • PDF

풍력발전단지 연계 전용선로 보호용 거리계전 알고리즘 (A Distance Protection Algorithm for a Transmission Line to Interconnect a Wind Farm to a Utility System)

  • 권영진;강상희;최동민;장성일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.516-518
    • /
    • 2005
  • This paper presents a distance protection algorithm a lied to the linked line for interconnecting wind farm with the utility. The capacity of wind farm is lower than utility system and its fault current level is very low. When a high resistance fault occurs in the linked line, it is difficult to detect accurate fault distance because of reactance effect. By using the characteristic of equivalent source impedance of induction generator which is compensated by capacitor bank and characteristic of the capacity of wind farm, this paper proposes improved distance protection algorithm applied to the linked line. A series of PSCAD/EMTDC simulation results have shown effectiveness of the proposed algorithm.

  • PDF

A Systematic Approach for Designing a Self-Tuning Power System Stabilizer Based on Artificial Neural Network

  • Sedaghati, Alireza
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.281-286
    • /
    • 2005
  • The main objective of the research work presented in this article is to present a systematic approach for designing a multilayer feed-forward artificial neural network based self-tuning power system stabilizer (ST-ANNPSS). In order to suggest an approach for selecting the number of neurons in the hidden layer, the dynamic performance of the system with ST-ANNPSS is studied and hence compared with that of conventional PSS. Finally the effect of variation of loading condition and equivalent reactance, Xe is investigated on dynamic performance of the system with ST-ANNPSS. Investigations reveal that ANN with one hidden layer comprising nine neurons is adequate and sufficient for ST-ANNPSS. Studies show that the dynamic performance of STANNPSS is quite superior to that of conventional PSS for the loading condition different from the nominal. Also it is revealed that the performance of ST-ANNPSS is quite robust to a wide variation in loading condition.

  • PDF

고주파특성 측정을 통한 barium titanate의 주파수센서 및 온도센서 연구 (Microwave Characteristics of Barium Titanate for Frequency Sensor and Temperature Sensor)

  • 김진옥;한만흥
    • 센서학회지
    • /
    • 제5권1호
    • /
    • pp.9-14
    • /
    • 1996
  • $WO_{3}$가 첨가된 $BaTiO_{3}$를 고상법으로 제작하여 상온에서 $160^{\circ}C$의 온도 범위와 300 kHz - 300 MHz의 주파수 범위에서 회로망분석기를 이용하여 2포트 S-파라메터 방법으로 고주파 저항, 리액턴스 및 임피던스를 측정하여 $130^{\circ}C$ 이하에서 주파수 및 온도센서로서의 가능성을 진단하였다.

  • PDF

Optimal Placement for FACTS to Improve Static Voltage Stability

  • Gu, Min-Yan;Baek, Young-Sik
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권3호
    • /
    • pp.141-145
    • /
    • 2004
  • FACTS devices, such as the Thyristor Controlled Series Compensator (TCSC) and Static Var Compensators (SVC), can help increase system load margin to improve static voltage stability. In power systems, because of the high cost and the effect value, the optimal placement for FACTS devices must be determined. This paper investigates the use of the series device (SVC) and the parallel device (TCSC) from the point of load margin to increase voltage stability. It considers the sensitivity of load margin to the line reactance and eigenvector of the collapse. The study has been carried out on the IEEE 14 Bus Test System to verify the validity and efficiency of the method. It reveals that incorporation of FACTS devices significantly enhance load margin as well as system stability.

송전선로의 상배열이 자계 크기에 미치는 영향 (Effect of Phase Arrangement on Magnetic Field of Overhead Transmission Lines)

  • 김상범;이동일;신구용;김점부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1678-1680
    • /
    • 1998
  • The purpose of this study is to obtain optimum arrangement of phase conductors in minimizing magnetic field from overhead transmission lines. Data of the transmission lines rated 345 kV of the KEPCO(Korea Electric Power Company)'s system were used. For a three phase-double circuit transmission line, low-reactance arrangement is optimum in minimizing magnetic fields. For a three phase-four circuit, optimum phase arrangement is a-b-c-b-a-c(lower two circuits, clockwise)/b-c-a-c-a-b(upper two circuits, clockwise).

  • PDF

브러시레스 전동기의 코깅토크 해석 및 특성해석 (Analysis of Cogging Torque and Characteristics in Brushless DC Motor)

  • 이지영;임양수;홍정표;김규탁;신상윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.629-631
    • /
    • 2000
  • This paper deals with the design of a inner rotor type Brushless DC (BLDC) motor for Electric Power Steering to reduce the cogging torque. The effect of the design parameters on the characteristic and cogging torque is analyzed by Finite Element Method (FEM). The considered design parameters are as follows : the number of pole and slot. dead-zone and skew angle. and teeth shape. The winding resistance of each motor is calculated and the characteristic curve is derived from considering reactance drop voltage for original model.

  • PDF

GOOSE 메시지를 이용한 고장점 추정 성능 개선 (Performance Enhancement for Fault Location Using GOOSE Messages)

  • 고철진;강상희
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권4호
    • /
    • pp.144-150
    • /
    • 2006
  • IEC 61850 is the worldwide protocol for the substation automation system. IEC 61850 transports the information which consists of different formats such as GOOSE(Generic Object Oriented Substation Event), MMS(Manufacturing Message Specification), SV(Sampled Values) and so on. For real time data transmission, GOOSE can be used. The remote-bus current data which were collected in a local-bus current differential IED can be transmitted to a distance IED at the same location by using GOOSE messages. The distance IED can eliminate the reactance effect by using the transmitted remote-bus current data. This method can improve the performance of the fault location.

765kV 비연가 송전선로에서 단상지락고장 시어 거리개전 알고리즘 (A New Distance Relaying Algorithm for Phase-to-Ground Fault in 765kV Untransposed Transmission Lines)

  • 안용진;강상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.452-454
    • /
    • 2004
  • An accurate digital distance relaying algorithm which is immune to reactance effect of the fault resistance and the load current for phase-to-ground fault in 765kV untransposed transmission lines is proposed. The algorithm can estimate adaptively the impedance to a fault point independent of the fault resistance. To compensate the magnitude and phase of the apparent impedance, this algorithm uses the angle of an impedance deviation vector. The impedance correction algorithm for Phase-to-ground fault uses a voltage equation at fault point to compensate the fault current at fault point. A series of tests using EMTP output data in a 765kV untransposed transmission lines have proved the accuracy and effectiveness of the proposed algorithm.

  • PDF