• Title/Summary/Keyword: Rays

Search Result 2,317, Processing Time 0.023 seconds

Landmark-based Morphometric and Meristic Analysis of Serranidae

  • Lim, Sang Gu;Jeong, Min Hwan;Kim, Bong Seok;Lee, Tae Ho;Gil, Hyun Woo;Park, In-Seok
    • Development and Reproduction
    • /
    • v.20 no.2
    • /
    • pp.51-63
    • /
    • 2016
  • The landmark-based morphometric and meristic analysis of the kelp grouper (Epinephelus bruneus), red spotted grouper (E. akaara) and seven-banded grouper (E. septemfasciatus) were performed to compare the differentiation of overall body shape and structure. The measurements of the morphometric dimensions were observed in 25 parts (truss dimension: 16 parts; head part dimension: 9 parts) of 38 morphometric dimensions and also meristic differences observed in 3 parts (dorsal fin, anal fin and caudal fin) of 6 meristic counts (P < 0.05). Observed morphometric characteristics primarily involved in truss and head part dimension, kelp grouper have larger values in caudal part of truss dimension, kelp grouper, red spotted grouper and seven-banded grouper have similar values in pectoral part of truss dimension, in addition to, results of head part dimension showed that red spotted grouper have smaller values in overall dimensions (P < 0.05). As meristic characteristics, kelp grouper have more number of anal fin rays than other fish, red spotted grouper have more number of dorsal soft rays than other fish, and seven spotted grouper have more number of anal soft rays, and caudal fin rays than other fish (P < 0.05). Photographed under the x-ray, kelp grouper have the most curved vertebral column and largest swim bladder than other fishes (P < 0.05). Our results of this study confirmed that 3 subfamily fishes adequately can distinguish with external body shape, and we hope that the results of our study could be used to identify in Serranidae family as taxonomical parameters.

Comparative Early Life History of Two Pipefish, Urocampus nanus and Syngnathus schlegeli (Syngnathidae) in Laboratory Culture from Korea (실험실 사육에 의한 한국산 실고기과(Syngnathidae) 2종, 풀해마(Urocampus nanus)와 실고기(Syngnathus schlegeli)의 초기생활사 비교)

  • Lee, Jae-Hwan;Kim, Jin-Koo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.53 no.1
    • /
    • pp.83-89
    • /
    • 2020
  • This study provides a detailed morphological description of larvae obtained from Urocampus nanus and Syngnathus schlegeli male brood fish over 20 days of culture in the laboratory. In both species, mating takes place when several males each spread their brood pouch like a wing to attract a female's attention. When the female begins to swim upward, the males follow her and receive her eggs in their brood pouches. Newborn larvae of U. nanus and S. schlegeli had already completed formation of dorsal and caudal fin rays, but not of pectoral fin rays. Pectoral fin rays were completely formed 15 days after release in S. schlegeli and 20 days after release in U. nanus. The ratio of caudal fin length to standard length increased until 8 days and decreased thereafter in S. schlegeli, while in U. nanus this ratio declined continuously after hatching. The larvae of the two species were very similar in external morphology, but well distinguished by the number of dorsal fin rays (15-16 in U. nanus vs. 39-43 in S. schlegeli), the presence of a membrane under the tail (absent in U. nanus vs. present in S. schlegeli), and the presence of melanophores in the dorsal fin (present in U. nanus vs. absent in S. schlegeli). Based on this study, U. nanus appears to be evolutionally more similar to pipefish than to seahorse.

Monte Carlo Simulation of Phytosanitary Irradiation Treatment for Mangosteen Using MRI-based Geometry

  • Oh, Se-Yeol;Kim, Jongsoon;Kwon, Soon-Hong;Chung, Sung-Won;Kwon, Soon-Goo;Park, Jong-Min;Choi, Won-Sik
    • Journal of Biosystems Engineering
    • /
    • v.39 no.3
    • /
    • pp.205-214
    • /
    • 2014
  • Purpose: Phytosanitary irradiation treatment can effectively control regulated pests while maintaining produce quality. The objective of this study was to establish the best irradiation treatment for mangosteen, a popular tropical fruit, using a Monte Carlo simulation. Methods: Magnetic resonance image (MRI) data were used to generate a 3-D geometry to simulate dose distributions in a mangosteen using a radiation transport code (MCNP5). Microsoft Excel with visual basic application (VBA) was used to divide the image data into seed, flesh, and rind. Radiation energies used for the simulation were 10 MeV (high-energy) and 1.35 MeV (low-energy) for the electron beam, 5 MeV for X-rays, and 1.25 MeV for gamma rays from Co-60. Results: At 5 MeV X-rays and 1.25 MeV gamma rays, all areas (seeds, flesh, and rind) were irradiated ranging from 0.3 ~ 0.7 kGy. The average doses decreased as the number of fruit increased. For a 10 MeV electron beam, the dose distribution was biased: the dose for the rind where the electrons entered was $0.45{\pm}0.03$ kGy and the other side was $0.24 {\pm}0.10$ kGy. Use of an electron kinetic energy absorber improved the dose distribution in mangosteens. For the 1.35 MeV electron beam, the dose was shown only in the rind on the irradiated side; no significant dose was found in the flesh or seeds. One rotation of the fruit while in front of the beam improved the dose distribution around the entire rind. Conclusion: These results are invaluable for determining the ideal irradiation conditions for phytosanitary irradiation treatment of tropical fruit.

Development of Naturally-spawned Pacific Herring Clupea pallasii Larvae (자연 산란된 청어(Clupea pallasii) 자어의 형태 발달)

  • Ji, Hwan-Sung;Lee, Dong Woo;Choi, Jung Hwa;Choi, Kwang Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.48 no.3
    • /
    • pp.362-367
    • /
    • 2015
  • We followed the development of Pacific herring Clupea pallasii larvae after natural hatching in Korean coastal waters off Dadaepo, where the water temperature was $9^{\circ}C$. Twenty days after hatching, the larvae had (i) reached a total length (TL) of 10.8-12.2 mm, (ii) developed 9-11 dorsal fin rays, and (iii) branched melanophores along the dorsal line of the gut in the anterior half of the body and along the posterior half of the dorsal and ventral line. Thirty days after hatching, the larvae had reached 12.2-13.5 mm TL, and the number of dorsal fin rays had increased to 13-14. Thirty-five days days after hatching, the larvae had reached 14.0-14.7 mm TL, and the posterior ends of their notochords had begun to flex upward. Forty-five days days after hatching, the larvae had (i) reached 15.6-15.9 mm TL, (ii) a complete set of dorsal fin rays (15-16), (iii) 12-13 anal fin rays, and (iv) branched melanophores along the dorsal part of the lateral surfaces of the head behind the caudal terminus. Preflexion, flexion and postflexion stage larvae had TL values of 13.5 mm, 14.0-15.3 mm, and 15.6-15.9 mm, respectively.

Validation of Morphology-based Identification of Two Cynoglossidae Larvae using Mitochondrial DNA (참서대과(Pisces: Cynoglossidae) 자어 2종의 미토콘드리아 DNA에 의한 형태동정의 타당성)

  • Kwun, Hyuck-Joon;Kim, Jin-Koo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.43 no.5
    • /
    • pp.482-488
    • /
    • 2010
  • Three specimens of Cynoglossidae larvae were collected from the southern Korean Sea in May and August of 2009, and were identified using morphological and molecular analysis. Specimens were divided into two groups based on the number of elongated dorsal fin rays on the top of the head: Cynoglossidae sp. A was defined as having two elongated dorsal fin rays, while Cynoglossidae sp. B possessed a single elongated dorsal fin ray. One specimen of Cynoglossidae sp. A, a post-larva with a notochord length (NL) of 5.8 mm was thought to be a Cynoglossus joyneri larva based on the presence of 115 dorsal pterogiophores, 85 anal pterogiophores, and 50 myomeres. Two specimens of Cynoglossidae sp. B, a 4.1 mm NL larva and a 11.3 mm NL juvenile, were thought to be Cynoglossus abbreviatus based on the presence of yolk in the former and 133 dorsal fin rays, 105 anal fin rays, and 63 myomeres in the latter. To test this morphology-based identification, molecular analysis was conducted using 419-422 bp of mitochondrial DNA 16S rRNA. Cynoglossidae sp. A was clearly matched to a Cynoglossus joyneri adult (d=0.000) and Cynoglossidae sp. B clustered closely with Cynoglossus abbreviatus adults (d=0.002). A neighbor-joining tree supported this robust relationship (bootstrap value=100%). Therefore, these molecular data validate the morphological identification of the two Cynoglossidae larval species.

Structure Analysis of Li-ion Battery Using Neutron Beam Source (중성자를 이용한 리튬이온 이차전지 전극 구조분석)

  • Kim, Chang-Seob;Park, Heon-Yong;Liang, Lianhua;Kim, Ji-Young;Seong, Baek-Seok;Kim, Keon
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.1
    • /
    • pp.20-24
    • /
    • 2007
  • Lithium ion secondary battery has been applied widely to portable devices, and has been studied for application to high power electric cell system such as power tool or hybrid electronic vehicle. The structure change of the electrodes materials occur when lithium ions move between electrodes. Neutron or X-rays can analyze the structure of electrode. The advantage of X-rays is convenient in test. However X-rays is scattered by electron cloud in atoms. Therefore, The elucidation for correct position of lithium is difficult with X-rays because lithium has small atomic weight. Neutron analysis techniques could solve this problem. In this review, We wish to discuss about structure analysis and the principle of structural characterization method using neutron beam source.

Description of Morphology and Osteology of the Slender Ribbonfish, Trachipterus ishikawae Jordan & Snyder, 1901 (투라치, Trachipterus ishikawae Jordan & Snyder, 1901의 형태 및 골격)

  • Han, Kyeong-Ho;Lee, Seong-Hoon;Kim, Chun-Cheol;Yu, Tae-Sik
    • Korean Journal of Ichthyology
    • /
    • v.32 no.3
    • /
    • pp.136-142
    • /
    • 2020
  • Morphology and osteology of the slender ribbonfish, Trachipterus ishikawae was described and figured in detail. The morphological characteristics are as follow: body elongate and compressed; upper jaw protrusile; tubercles along ventral edge of body and tail; eyes are large; body naked; caudal fin long and at a right angle to the body; from (3~4)+(7~8) gill rakers; from 180 to 185 dorsal fin rays, from 12 to 13 pectoral fin rays; 9 caudal fin rays and 5+2 short spine at caudal spine. The osteological characteristics are as follow: premaxillary is long and has four teeth; dentary is triangle shape; interopercle and subopercle are wide and flat; 5 branchiostegal rays; post clavicle is thin and long; from 79 to 80 centrum; posterior vertebrae elongate; 5~6 tubercles at urostyle bone.

Fundamental Study of nanoDot OSL Dosimeters for Entrance Skin Dose Measurement in Diagnostic X-ray Examinations

  • Okazaki, Tohru;Hayashi, Hiroaki;Takegami, Kazuki;Okino, Hiroki;Kimoto, Natsumi;Maehata, Itsumi;Kobayashi, Ikuo
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.229-236
    • /
    • 2016
  • Background: In order to manage the patient exposure dose in X-ray diagnosis, it is preferred to evaluate the entrance skin dose; although there are some evaluations about entrance skin dose, a small number of report has been published for direct measurement of patient. We think that a small-type optically stimulated luminescence (OSL) dosimeter, named nanoDot, can achieve a direct measurement. For evaluations, the corrections of angular and energy dependences play an important role. In this study, we aimed to evaluate the angular and the energy dependences of nanoDot. Materials and Methods: We used commercially available X-ray diagnostic equipment. For angular dependence measurement, a relative response of every 15 degrees of nanoDot was measured in 40-140 kV X-ray. And for energy dependence measurement, mono-energetic characteristic X-rays were generated using several materials by irradiating the diagnostic X-rays, and the nanoDot was irradiated by the characteristic X-rays. We evaluated the measured response in an energy range of 8.1-75.5 keV. In addition, we performed Monte-Carlo simulation to compare experimental results. Results and Discussion: The experimental results were in good agreement with those of Monte-Carlo simulation. The angular dependence of nanoDot was almost steady with the response of 0 degrees except for 90 and 270 degrees. Furthermore, we found that difference of the response of nanoDot, where the nanoDot was irradiated from the randomly set directions, was estimated to be at most 5%. On the other hand, the response of nanoDot varies with the energy of incident X-rays; slightly increased to 20 keV and gradually decreased to 80 keV. These results are valuable to perform the precise evaluation of entrance skin dose with nanoDot in X-ray diagnosis. Conclusion: The influence of angular dependence and energy dependence in X-ray diagnosis is not so large, and the nanoDot OSL dosimeter is considered to be suitable dosimeter for direct measurement of entrance surface dose of patient.

SENSITIVITY ANALYSIS TO EVALUATE THE TRANSPORT PROPERTIES OF CdZnTe DETECTORS USING ALPHA PARTICLES AND LOW-ENERGY GAMMA-RAYS

  • Kim, Kyung-O;Ahn, Woo-Sang;Kwon, Tae-Je;Kim, Soon-Young;Kim, Jong-Kyung;Ha, Jang-Ho
    • Nuclear Engineering and Technology
    • /
    • v.43 no.6
    • /
    • pp.567-572
    • /
    • 2011
  • A sensitivity analysis of the methods used to evaluate the transport properties of a CdZnTe detector was performed using two different radiations (${\alpha}$ particle and gamma-ray) emitted from an $^{241}Am$ source. The mobility-lifetime products of the electron-hole pair in a planar CZT detector ($5{\times}5{\times}2\;mm^3$) were determined by fitting the peak position as a function of biased voltage data to the Hecht equation. To verify the accuracy of these products derived from ${\alpha}$ particles and low-energy gamma-rays, an energy spectrum considering the transport property of the CZT detector was simulated through a combination of the deposited energy and the charge collection efficiency at a specific position. It was found that the shaping time of the amplifier module significantly affects the determination of the (${\mu}{\tau}$) products; the ${\alpha}$ particle method was stabilized with an increase in the shaping time and was less sensitive to this change compared to when the gamma-ray method was used. In the case of the simulated energy spectrum with transport properties evaluated by the ${\alpha}$ particle method, the peak position and tail were slightly different from the measured result, whereas the energy spectrum derived from the low-energy gamma-ray was in good agreement with the experimental results. From these results, it was confirmed that low-energy gamma-rays are more useful when seeking to obtain the transport properties of carriers than ${\alpha}$ particles because the methods that use gamma-rays are less influenced by the surface condition of the CZT detector. Furthermore, the analysis system employed in this study, which was configured by a combination of Monte Carlo simulation and the Hecht model, is expected to be highly applicable to the study of the characteristics of CZT detectors.

Dosimetric characterization and commissioning of a superficial electronic brachytherapy device for skin cancer treatment

  • Park, Han Beom;Kim, Hyun Nam;Lee, Ju Hyuk;Lee, Ik Jae;Choi, Jinhyun;Cho, Sung Oh
    • Nuclear Engineering and Technology
    • /
    • v.50 no.6
    • /
    • pp.937-943
    • /
    • 2018
  • Background: This work presents the performance of a novel electronic brachytherapy (EBT) device and radiotherapy (RT) experiments on both skin cancer cells and animals using the device. Methods and materials: The performance of the EBT device was evaluated by measuring and analyzing the dosimetric characteristics of X-rays generated from the device. The apoptosis of skin cancer cells was analyzed using B16F10 melanoma cancer cells. Animal experiments were performed using C57BL/6 mice. Results: The X-ray characteristics of the EBT device satisfied the accepted tolerance level for RT. The results of the RT experiments on the skin cancer cells show that a significant apoptosis induction occurred after irradiation with 50 kVp X-rays generated from the EBT device. Furthermore, the results of the animal RT experiments demonstrate that the superficial X-rays significantly delay the tumor growth and that the tumor growth delay induced by irradiation with low-energy X-rays was almost the same as that induced by irradiation with a high-energy electron beam. Conclusions: The developed new EBT device has almost the same therapeutic effect on the skin cancer with a conventional linear accelerator. Consequently, the EBT device can be practically used for human skin cancer treatment in the near future.