• Title/Summary/Keyword: Ray optics

Search Result 313, Processing Time 0.029 seconds

Design and Characteristic Measurement of 8000 mm Large Aperture Integrating Sphere

  • Zhang, Zhao;Wan, Zhi;Li, Xiansheng;Liu, Hongxing;Sun, Jingxu;Liu, Zexun;Wang, Yamin;Ren, Jianwei;Ren, Jianyue
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.500-509
    • /
    • 2016
  • Integrating spheres play a central role in the radiometric calibration of remote sensors. With the development of the wide field of view (FOV) remote sensors, aperture diameters of remote sensors are becoming larger and larger. To satisfy the radiometric calibration requirements of full FOV and full aperture, an 8000mm diameter large aperture integrating sphere uniform source with a variable exit port was designed and manufactured. This integrating sphere will be used for pre-launch test and radiometric calibration of remote satellites. In this paper, optical theories were used to design the output spectral radiance. The LightTools software based on ray-tracing simulation method was used to determine the best combination and distribution of inner light sources. A spectral experiment was made to verify the spectral radiance design. To reduce the influence of longtime power-on, a new characteristic measurement method was developed to obtain the radiation characteristic of the integrating sphere, which could greatly improve the measuring efficiency. This method could also be applied to measure other large aperture uniform sources. The obtained results indicate that the spatial uniformity is 98.35%, and the angular uniformity at center position is 98.78%.

Straylight analysis for preliminary filter and baffle design for New Generation GOCI

  • Oh, Eun-Song;Ahn, Ki-Beom;Jung, Kil-Jae;Ryu, Dong-Ok;Kim, Sug-Whan
    • Bulletin of the Korean Space Science Society
    • /
    • 2010.04a
    • /
    • pp.25.4-26
    • /
    • 2010
  • We present a three-mirror anastigmat(TMA) optical system for New Generation GOCI. In order to reduce the ghost optimized filter and baffle. By using carefully chosen antireflective coating and tilted filter angle, we fulfilled the design SNR requirement of 1500. We then designed a new entrance baffle and an internal baffle capable of producing the ghost ratio better than 0.01% of the nominal signal. The entrance baffle limits FOV to $0.75^{\circ}$ (E/W) $\times$ $0.60^{\circ}$ (S/N), and prevents the system from strong sun illumination, and the internal baffle prevents stray and scattered ray from entering into the telescope cavity. From these filter and baffle design, we confirmed that the instrument signal to noise ratio can be met with the current conceptual opto-mechanical design.

  • PDF

Long-Distance Plume Detection Simulation for a New MWIR Camera (장거리 화염 탐지용 적외선 카메라 성능 광선추적 수치모사)

  • Yoon, Jeeyeon;Ryu, Dongok;Kim, Sangmin;Seong, Sehyun;Yoon, Woongsup;Kim, Jieun;Kim, Sug-Whan
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.5
    • /
    • pp.245-253
    • /
    • 2014
  • We report a realistic field-performance simulation for a new MWIR camera. It is designed for early detection of missile plumes over a distance range of a few hundred kilometers. Both imaging and radiometric performance of the camera are studied by using real-scale integrated ray tracing, including targets, atmosphere, and background scene models. The simulation results demonstrate that the camera would satisfy the imaging and radiometric performance requirements for field operation.

Gaussian apodization and superresolution optical imaging system for soft X-ray region (Gaussian Apodization이 되어 있는 X-선 결상계의 초분해능)

  • 송영란;이민희;이상수
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.2
    • /
    • pp.89-95
    • /
    • 1996
  • Superresolution optics, employing Gaussian apodization, is rigorously treated at the soft X-ray wave-length(λ=0.013 ${\mu}{\textrm}{m}$) region. In the diffraction integral, the line integral along the imaginary axis is found small, and it is ignored, so that the diffraction integral consists of the integration along the real axis. The resolution of the diffracted image is not effected by the pupil angular frequency bandwidth $2{\omega}_0$, which is one of the most important the characteristic features of Gaussian apodization ($e^{-o^2x^2}$ optics. The superresolution optics has resolution ($\frac{1}{2}{\times}FWHM)$=$\Delta$x=0.008 $\mu$m which is smaller than the Rayleigh criterion of 2λ=0.026 ${\mu}{\textrm}{m}$ for NA=0.25. The optical system has ${\omega}_0{\ge}\frac{1}{2}{\sigma}$, which gives the peak intensity of the diffracted image larger than $e^{-2}$ times intensity obtainable by the infinite sperture.

  • PDF

Conceptual Design of Soft X-ray Microscopy for Live Biological Samples

  • Kim, Kyong-Woo;Nam, Ki-Yong;Kwon, Young-Man;Shim, Seong-Taek;Kim, Kyu-Gyeom;Yoon, Kwon-Ha
    • Journal of the Optical Society of Korea
    • /
    • v.7 no.4
    • /
    • pp.230-233
    • /
    • 2003
  • This study describes the conceptual design of a soft x-ray microscope system based on a laserbased source for biomedical application with high resolution (${\leq}$50nm). The laboratory scale soft x-ray microscope consists of high power laser plasma x-ray source and grazing incidence mirrors with high reflectivity. The laser plasma source used for developing this system employs Q-switched Nd-YAG pulsed laser. The laser beam is focused on a tantalum (Ta) target. The Wolter type I mirror was used as condenser optics for sample illumination and as objective mirror for focusing on a detector. The fabrication of the Wolter type I mirror was direct internal cutting using ultraprecision DTM. A hydrated biological specimen was put between the two silicon wafers, the center of which was $Si_3N_4$ windows of 100㎚ thickness. The main issues in the future development work are to make a stable, reliable and reproducible x-ray microscope system.

Improved Viewing Quality of 3-D Images in Computational Integral Imaging Reconstruction Based on Lenslet Array Model

  • Shin, Dong-Hak;Lee, Byoung-Ho;Kim, Eun-Soo
    • ETRI Journal
    • /
    • v.28 no.4
    • /
    • pp.521-524
    • /
    • 2006
  • In this letter, we propose a novel computational integral imaging reconstruction technique based on a lenslet array model. The proposed technique provides improvement of viewing images by extracting multiple pixels from elemental images according to ray tracing based on the lenslet array model. To show the feasibility of the proposed technique, we analyze it according to ray optics and present the experimental results.

  • PDF

Analysis of the indoor radio signal propagation characteristics by ray-tracing technique (Ray-Tracing을 이용한 구내 전파 전파특성 해석)

  • Ryu, Hwang
    • The Journal of Natural Sciences
    • /
    • v.8 no.2
    • /
    • pp.101-109
    • /
    • 1996
  • In this paper, using the derived formula based on field theory both geometrical optics and diffraction theory, several features of same buildings of Bertoni's construction that influence the propagation of signals between antennas located on the same floor have been investigated theoretically and compared with previously studied results.

  • PDF

Finite Raytracing Through Non-rotationally Symmetric Systems (비대칭형 광학계의 유한광선추적)

  • 홍경희
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.217-222
    • /
    • 1990
  • A general ray tracing scheme has been developed for using a personal computer which trace finite rays through any non-rotationally symmetric system. This scheme may be used for the surface type such as conic section with or without aspherics, toric surfaces, sagittal and tangential cylindrical sections and axicons. Specially, any combinational of decentered, tilted and rotated surfaces has been considered. Before transfering to the next surfaces, the local coordinates are refered back to an initial reference coordinate system. We can get a mathmtical model of a non-rotationally symmetrical finite ray trace running on an inexpensive personal computer.

  • PDF

Wide Field-of-View Imaging Using a Combined Hyperbolic Mirror

  • Yi, Sooyeong;Ko, Youngjun
    • Current Optics and Photonics
    • /
    • v.1 no.4
    • /
    • pp.336-343
    • /
    • 2017
  • A wide field-of-view (FOV) image contains more visual information than a conventional image. This study proposes a new type of hyperbolic mirror for wide FOV image acquisition. The proposed mirror consists of a hyperbolic cylindrical section and a bowl-shaped hyperbolic omnidirectional section. Using an imaging system with this mirror, it is possible to achieve a $213.8^{\circ}$ horizontal and a $126.94^{\circ}$ vertical maximum FOV. Parameters of each section of the mirror are designed to be continuous at the junction of the two parts, and the resultant image is seamless. The image-acquisition model is obtained using ray-tracing optics. To rectify the geometrical distortion of the original image due to the mirror, an image-restoration algorithm based on conformal projection is presented in this study. The performance of the proposed imaging system with the hyperbolic mirror and its image-restoration algorithm are verified by experiments.

Optical Design of an Image-space Telecentric Two-mirror System for Wide-field Line Imaging

  • Lee, Jong-Ung;Kim, Youngsoo;Kim, Seo Hyun;Kim, Yeonsoo;Kim, Hyunsook
    • Current Optics and Photonics
    • /
    • v.1 no.4
    • /
    • pp.344-350
    • /
    • 2017
  • We present a new design approach and an example design for an image-space telecentric two-mirror system that has a fast f-number and a wide-field line image. The initial design of the telecentric mirror system is a conventional axially symmetric system, consisting of a flat primary mirror with fourth-order aspheric deformation and an oblate ellipsoidal secondary mirror to correct spherical aberration, coma, and field curvature. Even though in the optimized design the primary mirror is tilted, to avoid ray obstruction by the secondary mirror, the image-space telecentric two-mirror system shows quite good imaging performance, for a line imager.