• Title/Summary/Keyword: Ray Density

Search Result 1,758, Processing Time 0.033 seconds

A study on dose attenuation in bone density when TBI using diode detector and TLD (전신방사선조사(TBI)시 다이오드 측정기(Diode detector) 및 열형광선량계(TLD)를 이용한 골조직 선량감쇄에 대한 고찰)

  • IM Hyun Sil;Lee Jung Jin;Jang Ahn Ki;Kim Wan Seon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.67-77
    • /
    • 2003
  • I. Purpose Uniform dose distribution of the whole body is essential factor for the total body irradiation(TBI). In order to achieved this goal, we used to compensation filter to compensate body contour irregularity and thickness differences. But we can not compensate components of body, namely lung or bone. The purpose of this study is evaluation of dose attenuation in bone tissue when TBI using diode detectors and TLD system. II. Materials and Methods The object of this study were 5 patients who undergo TBI at our hospital. Dosimetry system were diode detectors and TLD system. Treatment method was bilateral and delivered 10MV X-ray from linear accelerator. Measurement points were head, neck, pelvis, knees and ankles. TLD used two patients and diode detectors used three patients. III. Results Results are as followed. All measured dose value were normalized skin dose. TLD dosimetry : Measured skin dose of head, neck, pelvis, knees and ankles were $92.78{\pm}3.3,\;104.34{\pm}2.3,\;98.03{\pm}1.4,\;99.9{\pm}2.53,\;98.17{\pm}0.56$ respectably. Measured mid-depth dose of pelvis, knees and ankles were $86{\pm}1.82,\;93.24{\pm}2.53,\;91.50{\pm}2.84$ respectably. There were $6.67\%{\sim}11.65\%$ dose attenuation at mid-depth in pelvis, knees and ankles. Diode detector : Measured skin dose of head, neck, pelvis, knees and ankles were $95.23{\pm}1.18,\;98.33{\pm}0.6,\;93.5{\pm}1.5,\;87.3{\pm}1.5,\;86.90{\pm}1.16$ respectably. There were $4.53\%{\sim}12.6\%$ dose attenuation at mid-depth in pelvis, knees and ankles. IV. Conclusion We concluded that dose measurement with TLD or diode detector was inevitable when TBI treatment. Considered dose attenuation in bone tissue, We must have adequately deduction of compensator thickness that body portion involved bone tissue.

  • PDF

The Study of Technical Error Analysis on BMD Using DEXA (이중 에너지 X선 흡수 계측법을 이용한 BMD 검사 시 발생할 수 있는 기술적인 오류 분석)

  • Kang, Yeong-Han;Jo, Gwang-Ho
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.229-236
    • /
    • 2006
  • Purpose: This study was conducted to search for the type of technical error in DEXA(dual-energy X-ray absorptiometry) and the effect of error to measurement of BMD. Materials and Methods: The changes of BMD($g/cm^2$, T-score) by patients information(Age, Weight, Height, Manopause age) input error and Confirming ROI error were investigated. Using spine phantom, we canned 10 times by age(5, 10), weight(10, 20 kg), height(5, 10 cm), manopause age(5, 10) increase & decrease respectively. Scanning region(L-spine, femur, Forearm) of 10 patients was calculated by changing ROI respectively. Analysis of difference for mean(precision 1%) were carried out. Results: The error of patient information(Age, Weight, Height, Manopause age) was not changed differently. In confirming ROI, the BMD and T-score of L-spine involving T-12 was decreased to $0.063\;g/cm^2$, 0.3 and involving L-5 increased to $0.077\;g/cm^2$, 0.5. In narrowing 1 cm of vertical line of ROI, the BMD and T-score decreased to $0.006\;g/cm^2$, 0.1 and in 2 cm, $0.021\;g/cm^2$, 0.15, each. In hip ROI, Upper and left shift(0.5 cm) of line was not influenced BMD and T-score. In 0.5 cm lower shift(lesser trochanter below), the BMD and T-score increased $0.031\;g/cm^2$, 0.3 and in 1 cm $0.094\;g/cm^2$, 0.65, each. In forearm ROI, the BMD and T-score decreased $0.042\;g/cm^2$, 0.9 involving 1 cm lower wrist. And expanding 1 cm of vertical line, the BMD and T-score decreased $0.008\;g/cm^2$, 0.1 and in 2 cm, $0.021\;g/cm^2$, 0.3, each. The L-spine, hip, forearm ROI error was changed differently. Conclusion: There are so many kinds of technical error in BMD processing. Errors according to age, weight, height, manopause age did not influent to $BMD(g/cm^2)$ and T-score. There are mean differences BMD and T-score in confirming ROI. For the precision exam, in L-spine processing, L1-4 have to confirmed without shift of ROI vertical line. In hip processing, the ROI have to included greater trochanter, femur head and lesser trochanter. In forearm processing, the ROI have to included wrist, radius and ulnar.

  • PDF

Study on Measurements of the Mandible BMD According to the ROI Variation (관심영역 변화에 따른 하악골 골밀도 측정에 대한 연구)

  • Tak, Jeong-Nam
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.271-276
    • /
    • 2009
  • The aim of this study was to evaluate the effect of Bone Mineral Density(BMD) at mandible. So, we studied how to measure the BMD at mandible using DEXA(Dual energy X-ray absorptiometry, DEXA) by Horner er al (1996) and knew reproducibility of the measurements. Thirty-five patients (13 men, 22 women, mean age : 25.4 years) were examined using the GE Lunar Prodigy Advance(LUNAR Corporation, madison, USA). They were examined in Semiprone position of their body and true lateral position of their mandible selected the Lumbar lateral mode. We used the custom mode in analysis when ROI (area $30{\times}2.5\;mm^2$). Three ROIs ($30{\times}2.5\;mm^2$, $50{\times}2.5\;mm^2$, $20{\times}2.5\;mm^2$) were located each at the two different sites of the mandible (angle of mandible and mental symphysis) and BMD was measured. Differences in BMD measurement was statistically compared according to the size and location of ROI. BMD was $1.320{\pm}0.358g/cm^3$ in men and was $1.152{\pm}0.340g/cm^3$ in women. BMD at the angle of mandible was $1.201{\pm}0.361g/cm^3$ in men and was $1.025{\pm}0.377g/cm^3$ in women. BMD of men at the mental symphysis was $1.434{\pm}0.341g/cm^3$ and that of women was $1.19{\pm}0.358g/cm^3$. With the ROI of $20{\times}2.5\;mm^2$, BMD was $1.262{\pm}0.384g/cm^3$ in men and was $1.113{\pm}0.357g/cm^3$ in women. With the ROI of $50{\times}2.5\;mm^2$, BMD of men was $1.320{\pm}0.358g/cm^3$ and that of women was $1.129{\pm}0.340g/cm^3$. There was a statistically significant difference of BMD according to the size and location of ROI. When measuring mandible BMD, there are good for increasing ROI and locate between ramus and mental symphysis. Especially following exam, refer to same size and location with fore exam. According to study which measure mandible BMD, It's correct to measure better a portion of mandible then whole of BMD. Using DEXA protocol is studied good for the additional study to compare the BMD at mandible. Later date, It will be good for measurement value in implant and bone graft quantitatively. Using DEXA method gain BMD threshold value in korean.

  • PDF

Effects of 1 keV $Ar^+$ ion irradiation on Au films on glass (1 keV $Ar^+$ 이온의 조사가 유리기판위의 금 박막의 미치는 영향)

  • Jang, H. G.;Kim, H. S.;Han, S.;Choi, W. K.;Koh, S. K.;Jung, H. J.
    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.4
    • /
    • pp.371-376
    • /
    • 1996
  • Au films with a thickness around 1600 $\AA$ were deposited onto glass at room temperature by ion beam sputtering with a 5 cm cold-hollow ion gun at pressure $1\times 10^{-6}-1\times 10^{-5}$ Torr. Irradiation of the Au deposited samples was carried out at pressure of $7\times 10^{-6}$ Torr. For the sputter depositions, $Ar^+$ ion energy was 1 keV, and the current density at the substrate surface was 15 $\mu$A/$\textrm{cm}^2$. Effects of 1 keV $Ar^+$ ion dose($I_d$) between $1\times 10^{16}\; and\;2\times 10^{17}\;Ar^+\textrm{cm}^{-2}$on properties such as crystallinity, surface roughness and adhesion, etc. of the films have been investigated. The Au films sputtered by $Ar^+$ ion beam had only (111) plane and the X-ray intensity of the films decreased with increase of $I_d$. The thickness of Au films reduced with Id. $R_{ms}$ surface roughness of the films increased from 16 $\AA$ at as-deposited to 1118 $\AA$ at ion dose= $2\times 10^{17}\;Ar^+\textrm{cm}^{-2}$. Adhesion of Au film on sputtered at $I_d$= $2\times 10^{17}\;Ar^+\textrm{cm}^{-2}$ was 9 times greater than that of Au film with untreated, as determined by a scratch test.

  • PDF

Multi-classification of Osteoporosis Grading Stages Using Abdominal Computed Tomography with Clinical Variables : Application of Deep Learning with a Convolutional Neural Network (멀티 모달리티 데이터 활용을 통한 골다공증 단계 다중 분류 시스템 개발: 합성곱 신경망 기반의 딥러닝 적용)

  • Tae Jun Ha;Hee Sang Kim;Seong Uk Kang;DooHee Lee;Woo Jin Kim;Ki Won Moon;Hyun-Soo Choi;Jeong Hyun Kim;Yoon Kim;So Hyeon Bak;Sang Won Park
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.187-201
    • /
    • 2024
  • Osteoporosis is a major health issue globally, often remaining undetected until a fracture occurs. To facilitate early detection, deep learning (DL) models were developed to classify osteoporosis using abdominal computed tomography (CT) scans. This study was conducted using retrospectively collected data from 3,012 contrast-enhanced abdominal CT scans. The DL models developed in this study were constructed for using image data, demographic/clinical information, and multi-modality data, respectively. Patients were categorized into the normal, osteopenia, and osteoporosis groups based on their T-scores, obtained from dual-energy X-ray absorptiometry, into normal, osteopenia, and osteoporosis groups. The models showed high accuracy and effectiveness, with the combined data model performing the best, achieving an area under the receiver operating characteristic curve of 0.94 and an accuracy of 0.80. The image-based model also performed well, while the demographic data model had lower accuracy and effectiveness. In addition, the DL model was interpreted by gradient-weighted class activation mapping (Grad-CAM) to highlight clinically relevant features in the images, revealing the femoral neck as a common site for fractures. The study shows that DL can accurately identify osteoporosis stages from clinical data, indicating the potential of abdominal CT scans in early osteoporosis detection and reducing fracture risks with prompt treatment.

The Relationship of Age, Body Mass Index, and Individual Habit to Bone Mineral Density in Adults (성인의 연령, 체질량지수 및 생활습관과 골밀도의 관계)

  • Park, Soung-Ock;Lee, In-Ja;Shin, Gwi-Soon
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.367-377
    • /
    • 2008
  • We studied the change of bone mineral density (BMD) by age, body mass index (BMI), coffee, carbonated drink, alcohol, smoking, and exercise in adults who checked in health center. The number of study subjects was total 268 persons (women of 136 persons and men of 132 persons). The BMD was determined in lumbar spine and femoral neck by dual energy x-ray absorptiometry. And we got some results as below : 1. In women, mean body height was $155.8{\pm}6.0cm$, mean body weight was $56.8{\pm}7.9kg$, and mean BMI was $23.4{\pm}3.1kg/m^2$. In men, mean body height was $169.1{\pm}6.0cm$, mean body weight was $69.0{\pm}9.5kg$, and mean BMI was $24.1{\pm}2.7kg/m^2$. 2. BMD decreased as age increased, and the age was the most determinant factor for BMD (p<0.01). Women's BMD decreased rapidly in the groups aged $\geq$50s, while men's BMD decreased gradually with age. In addition, for both sex, lower BMD was measured in lumbar spine than in femoral neck. 3. BMD increased in high BMI, and BMD with BMI increased distinctly in the group aged 50s. But their relationship was not significant. 4. In view of the distribution by three BMD categories, women's BMD was mostly normal in the groups aged $\geq$40s, but the rate of osteopenia and osteoporosis was similar in the group aged 50s, and the rate of osteoporosis was the highest in the groups aged 60s and 70s. Men's BMD was mostly normal through all groups except the group aged 70s. 5. Coffee and carbonated drink were not influenced in BMD. But alcohol-drinking group showed higher BMD than non-drinking group, and alcohol was statistically significant determinant for BMD (p<0.05). Smoking and exercise were not statistically significant determinant of BMD.

  • PDF

Fabrication and characteristics of modified PZT System doped With $La_2O_3$ ($La_2O_3$가 첨가된 modified PZT계의 제조 및 특성)

  • 황학인;박준식;오근호
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.7 no.3
    • /
    • pp.418-427
    • /
    • 1997
  • The effect of $La_2O_3$ as a dopant on the microstructure structure, crystal structure and electrical properties was studied. $0.05Pb(Sn_{0.5}Sb_{0.5})O_3+0.11PbTiO_3+0.84PbZroO_3+0.4Wt%MnO_2$ (=0.05PSS +0.11PT+0.84PZ+0.4wt%$MnO_2$) systems doped with 0, 0.1, 0.3, 0.5, 0.7, 1, 3, 5 mole% $La_2O_3$ were fabricated and investigated sintering density, crystal structure and micro-structure. The sintered 0.05PSS+0.11PT+0.84PZ+0.4wt%$MnO_2$ system doped with $La_2O_3$showed sintering density of the range of 7.683 g/㎤ of 0 mole% doping to 7.815 g/㎤ of 0 mole% doping. The average grain sizes in the range of 0 to 5 mole% $La_2O_3$were decreased from 9.0 $\mu\textrm{m}$ to 1.3 $\mu\textrm{m}$. X-ray diffraction investigation of sintered bodies showed that solid solutions were formed between 0.05PSS+0.11PT+0.84PZ+0.4wt%$MnO_2$ system and $La_2O_3$ in the range of 0 to 1 mole% but second phases were formed in case of 3, 5 mole%. Dielectric constants at 1 kHz were increased with 0 to 3 mlole% $La_2O_3$ before and after poling at the condition of 5 $KV_{DC}$/mm at $120^{\circ}C$ or $140^{\circ}C$ during 20 minutes. All Dielectric losses at 1 kHz were less than 1%, Curie temperatures were $208^{\circ}C$, $183^{\circ}C$, $152^{\circ}C$ and $127^{\circ}C$ at 0, 0.5, 1, 3 mole% $La_2O_3$ respectively. The values of $K_p$ were increased from 0 to 3 mole% $La_2O_3$ after poling at condition of 5 $KV_{DC}$mm at the condition of $120^{\circ}C$ or $140^{\circ}C$. The case of 0.7 mole% $La_2O_3$doped 0.05PSS+0.11PT+0.84PZ+0.4wt%$MnO_2$ system showed $K_p$ of 14.5% by poling at $140^{\circ}C$ during 20 minutes.

  • PDF

An Analysis of BMD Changes With Preoperative and Postoperative Premenopausal Breast Cancer Patient (폐경 전 유방암 환자의 치료 전.후 골밀도 변화 분석)

  • Kim, Su-Jin;Son, Soon-Yong;Choi, Kwan-Woo;Lee, Joo-Ah;Min, Jung-Whan;Kim, Hyun-Soo;Ma, Sang-Chull;Lee, Jong-Seok;Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.279-286
    • /
    • 2014
  • The purpose of this study is to provide basic data of comparing BMD(bone mineral density) value of preoperative breast cancer patient and postoperative breast cancer patient due to bone loss with radiation/chemical therapy. The participants consisted of 254 breast cancer patients with BMD after having surgery and treatment from March 2007 to September 2013. Except for 84 patients with menopause or hysterectomy and we have analysed 171 patients. The BMD value(lumbar spine and femur) of before and after treatment from PACS by dure-energy X-ray absorptiometry was analyzed. First, we found variation of entire BMD and BMD according to treatment type, and analyzed detailed correlation by using marital status, number of children, presence of feeding, age of menarche, breast cancer therapy types as variable. Data was analyzed by using SPSS for Windows Program(version 18.0). BMD was decreased 7.1% in lumbar spine, 3.1% in femur respectively(p<.01). Also there is relatively high decrement($0.067g/cm^2$) in group who had just chemotherapy in femur(p<.05). There is decrement depend on marital status, number of children, presence of feeding, age of menarche, breast cancer therapy types but there was no statistical significance. The results show that BMD was decreased after treatment in premenopausal breast cancer patient, patient who had relatively high decrement need to be included high-risk group. As a result, aggressive prevention policy would be necessary.

Investigation of Scatter and Septal Penetration in I-131 Imaging Using GATE Simulation (GATE 시뮬레이션을 이용한 I-131 영상의 산란 및 격벽통과 보정방법 연구)

  • Jung, Ji-Young;Kim, Hee-Joung;Yu, A-Ram;Cho, Hyo-Min;Lee, Chang-Lae;Park, Hye-Suk
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.72-79
    • /
    • 2009
  • Scatter correction for I-131 plays a very important role to improve image quality and quantitation. I-131 has multiple and higher energy gamma-ray emissions. Image quality and quantitative accuracy in I-131 imaging are degraded by object scatter as well as scatter and septal penetration in the collimator. The purpose of this study was to estimate scatter and septal penetration and investigate two scatter correction methods using Monte Carlo simulation. The gamma camera system simulated in this study was a FORTE system (Phillips, Nederland) with high energy, general-purpose, parallel hole collimator. We simulated for two types of high energy collimators. One is composed of lead, and the other is composed of artificially high Z number and high density. We simulated energy spectrum using a point source in air. We estimated both full width at half maximum (FWHM) and full width at tenth maximum (FWTM) using line spread function (LSF) in cylindrical water phantom. We applied two scatter correction methods, triple energy window scatter correction (TEW) and extended triple energy window scatter correction (ETEW). The TEW method is a pixel-by pixel based correction which is easy to implement clinically. The ETEW is a modification of the TEW which corrects for scatter by using abutted scatter rejection window, which can overestimate or the underestimate scatter. The both FWHM and FWTM were estimated as 41.2 mm and 206.5 mm for lead collimator, respectively. The FWHM and FWTM were estimated as 27.3 mm and 45.6 mm for artificially high Z and high density collimator, respectively. ETEW showed that the estimation of scatter components was close to the true scatter components. In conclusion, correction for septal penetration and scatter is important to improve image quality and quantitative accuracy in I-131 imaging. The ETEW method in scatter correction appeared to be useful in I-131 imaging.

  • PDF

Therapeutic Efficacy of Alendronate for Glucocorticoid Induced Metabolic Bone Disease in Children with Nephrotic Syndrome (신증후군 환아에서 스테로이드 유발 대사성 골질환에 대한 Alendronate의 치료 효과)

  • Lee Ji-Eun;Lee Hyun-Ok;Paik Kyung-Hoon;Lee Suk-Hyang;Jin Dong-Kyu
    • Childhood Kidney Diseases
    • /
    • v.8 no.1
    • /
    • pp.33-42
    • /
    • 2004
  • Purpose : Children with nephrotic syndrome(NS) are under high risk for metabolic bone disease(MBD) as a complication of long-term glucocorticoid therapy. We prospectively evaluated the effect of oral bisphosphonate(alendronate) therapy in children with NS, which has proven efficacy in adult patients with glucocorticoid induced MBD. Methods : Among 58 children with NS, aged 5 to 8 years and haying a disease duration of more than 2 years, 30(51.7%) were enrolled to meet the selection criteria, less than -1.0 Z-scores of lumbar spine bone mineral density(BMD) by dual energy X-ray absorptiometry (DEXA). These 30 children were divided into three groups and each were assigned to receive alendronate, calcitriol, and no-medication, respectively for one year. Lumbar spine BMD was followed up every 6 months and the biochemical indexes were measured before and 1 year after the treatment. There were no significant difference among groups with respect to the average age, the initial BMD, and the cumulative steroid doses. Analysis of the treatment efficacy was done by the % change of BMD and by the changes in Z-scores of lumbar spine BMD. Results : Mean age and disease duration of patients at the initial lumbar spine BMD evaluation was $7.4{\pm}1.7$ years and $2.2{\pm}1.2$ years, respectively. Twenty-three of 30 children(76%) had osteopenia, and seven(23%) had osteoporosis. There was no difference in the biochemical values among the groups, before and 1 year after the treatment(P<0.05). Twenty two children(73.3%) with frequent relapsing or steroid dependant NS had more frequent MBD, compared to the 8 children(26.6%) with infrequent relapsing NS. The one year % changes of BMD were 8.56 in alendronate group, 5.79 in calcitriol group, and 1.9 in no-medication group. The changes in Z-score of lumbar spine BMD increased in the alendronate group and the calcitriol group, but not in the no-medication group. One year % changes of BMD were different among groups(P=0.0002). Significant differences were found between the alendronate and the no-medication group, and between the calcitriol and the no-medication group(P<0.05). There was no difference between the alendronate and the calcitriol group. No serious adverse effect was observed in the alendronate group. Conclusion : Children with NS receiving high dose steroids are under the high risk of BMD and should undergo regular BMD evaluation. Z-score of lumbar spine BMD was a useful parameter in diagnosing low bone mass in children. Alendronate weekly oral therapy was effective and relatively safe in increasing the lumbar spine BMD in children with NS having steroid induced MBD.

  • PDF