• Title/Summary/Keyword: Ray

Search Result 20,515, Processing Time 0.047 seconds

Calibration-free real-time organic film thickness monitoring technique by reflected X-Ray fluorescence and compton scattering measurement

  • Park, Junghwan;Choi, Yong Suk;Kim, Junhyuck;Lee, Jeongmook;Kim, Tae Jun;Youn, Young-Sang;Lim, Sang Ho;Kim, Jong-Yun
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1297-1303
    • /
    • 2021
  • Most thickness measurement techniques using X-ray radiation are unsuitable in field processes involving fast-moving organic films. Herein, we propose a Compton scattering X-ray radiation method, which probes the light elements in organic materials, and a new simple, non-destructive, and non-contact calibration-free real-time film thickness measurement technique by setting up a bench-top X-ray thickness measurement system simulating a field process dealing with thin flexible organic films. The use of X-ray fluorescence and Compton scattering X-ray radiation reflectance signals from films in close contact with a roller produced accurate thickness measurements. In a high-thickness range, the contribution of X-ray fluorescence is negligible, whereas that of Compton scattering is negligible in a low-thickness range. X-ray fluorescence and Compton scattering show good correlations with the organic film thickness (R2 = 0.997 and 0.999 for X-ray fluorescence and Compton scattering, respectively, in the thickness range 0-0.5 mm). Although the sensitivity of X-ray fluorescence is approximately 4.6 times higher than that of Compton scattering, Compton scattering signals are useful for thick films (e.g., thicker than ca. 1-5 mm under our present experiment conditions). Thus, successful calibration-free thickness monitoring is possible for fast-moving films, as demonstrated in our experiments.

Reference X-ray Irradiation System for Personal Dosimeter Testing and Calibration of Radiation Detector

  • Lee, Seung Kyu;Chang, Insu;Kim, Sang In;Lee, Jungil;Kim, Hyoungtaek;Kim, Jang-Lyul;Kim, Min Chae
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.2
    • /
    • pp.72-78
    • /
    • 2019
  • Background: In the calibration and testing laboratory of Korea Atomic Energy Research Institute, the old X-ray generator used for the production of reference X-ray fields was replaced with a new one. For this newly installed X-ray irradiation system, beam alignment as well as the verification of beam qualities was conducted. Materials and Methods: The existing X-ray generator, Phillips MG325, was replaced with YXLON Y.TU 320-D03 in order to generate reference X-ray fields. Theoretical calculations and Monte Carlo simulations were used to determine initial filter thickness. Beam alignment was performed in three steps to deliver a homogeneous radiation dosage to the target at different distances. Finally, the half-value layers were measured for different X-ray fields to verify beam qualities by using an ion chamber. Results and Discussion: Beam alignment was performed in three steps, and collimators and other components were arranged to maintain the uniformity of the mean air kerma rate within ${\pm}2.5%$ at the effective beam diameter of 28 cm. The beam quality was verified by using half-value layer measurement methods specified by American National Standard Institute (ANSI) N13.11-2009 and International Organization for Standardization (ISO)-4037. For each of the nine beams than can be generated by the new X-ray irradiation system, air kerma rates for X-ray fields of different beam qualifies were measured. The results showed that each air kerma rate and homogeneity coefficient of the first and second half-value layers were within ${\pm}5%$ of the recommended values in the standard documents. Conclusion: The results showed that the new X-ray irradiation system provides beam qualities that are as high as moderate beam qualities offered by National Institute of Standards and Technology in ANSI N13.11-2009 and those for narrow-spectrum series of ISO-4037.

Development of Medical Image Quality Assessment Tool Based on Chest X-ray (흉부 X-ray 기반 의료영상 품질평가 보조 도구 개발)

  • Gi-Hyeon Nam;Dong-Yeon Yoo;Yang-Gon Kim;Joo-Sung Sun;Jung-Won Lee
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.12 no.6
    • /
    • pp.243-250
    • /
    • 2023
  • Chest X-ray is radiological examination for xeamining the lungs and haert, and is particularly widely used for diagnosing lung disease. Since the quality of these chest X-rays can affect the doctor's diagnosis, the process of evaluating the quality must necessarily go through. This process can involve the subjectivity of radiologists and is manual, so it takes a lot of time and csot. Therefore, in this paper, based on the chest X-ray quality assessment guidelines used in clinical settings, we propose a tool that automates the five quality assessments of artificial shadow, coverage, patient posture, inspiratory level, and permeability. The proposed tool reduces the time and cost required for quality judgment, and can be further utilized in the pre-processing process of selecting high-quality learning data for the development of a learning model for diagnosing chest lesions.

A Study on the Optimal X-ray Angle to Observe Calcaneus (발꿈치뼈를 관찰하기 위한 최적의 X-ray 각도에 대한 고찰)

  • Sang-Min Shin;Bo-Moon Seo;Hae-In Jeon;Gyoung-Han Lee;Min-Cheol Jeon
    • Journal of Advanced Technology Convergence
    • /
    • v.2 no.1
    • /
    • pp.17-21
    • /
    • 2023
  • In this study, using an X-ray device (Drgem TS-CSP) and foot phantom (SFT-1556), the angle of the X-ray tube was changed to 30°, 35°, 40°, 45°, and 50°, and the image was evaluated by quantitative and qualitative evaluation. In the blind test, it was the highest at 4.34 points at 40°, and in the part calculation using the Image J program, the angle was the largest at 1750 at 50°. In addition, in the area evaluation excluding overlapping areas, the X-ray tube showed the largest value at 40° Therefore, it was found that the X-ray tube angle was suitable when the X-ray tube angle was 40° as a projection method for observing the calcaneus.

The Importance of Positioning in Left Lateral Chest X-Ray Examination (흉부 왼쪽 엑스선검사 시 위치 잡기의 중요성)

  • Pyong-Kon Cho
    • Journal of radiological science and technology
    • /
    • v.46 no.4
    • /
    • pp.287-294
    • /
    • 2023
  • This study was conducted to ultimately reduce unnecessary radiation exposure by emphasizing the need and importance of correct positioning by examining the positioning relationship of anatomical structures in the human body and changes in X-ray images according to changes in patient positioning during the left lateral chest X-ray examination. This study investigated and analyzed previously published papers and books on the left lateral chest X-ray examination to find out the importance of positioning in the left lateral chest X-ray examination. To find out the importance of correct positioning in the left lateral chest X-ray, we compared three images of incorrectly positioned right thorax and left thorax rotated forward and the lower median surface of the body leaning against the image receptor. In the left lateral chest examination, a distorted image was obtained in which the shape of the anatomical structure observed in the image was changed according to the presence or absence of rotation of the patient and the inclination of the median visual surface. X-ray images with the most accurate and large amount of information were obtained from X-ray images with the correct positioning performed during left lateral chest X-ray examination. Therefore, It is believed that the left lateral chest X-ray examination will have beneficial effects such as providing accurate medical information, preventing misdiagnosis, reducing social costs, and ultimately reducing radiation exposure.

Doses of Electron Beam and X-ray Irradiation for Inhibition of Development and Reproduction in Four Insect Pests (4종 해충의 발육과 생식에 대한 전자빔과 X-ray의 억제선량)

  • Yun, Seung-Hwan;Kim, Minjun;Kim, Hyunah;Lee, Seon-Woo;Yoo, Dae Hyun;Kim, Hyun Kyung;Koo, Hyun-Na;Kim, Gil-Hah
    • Korean journal of applied entomology
    • /
    • v.53 no.4
    • /
    • pp.391-398
    • /
    • 2014
  • This study investigated inhibitory doses of electron beam and X-ray irradiation by comparing their effects on the development and reproduction of four insect pests (Myzus persicae, Tetranychus urticae, Liriomyza trifolii, and Frankliniella intonsa). When M. persicae nymphs were irradiated with 100 Gy of electron beam and 30 Gy of X-ray beam, offspring production by adults that developed from the treated nymphs was completely inhibited. When M. persicae adults were irradiated with 200 Gy of electron beam and 50 Gy of X-ray beam, emergence of the $F_1$ generation was inhibited. However, these two ionizing radiations did not affect adult longevity. When T. urticae eggs were irradiated with 150 Gy of electron beam and 50 Gy of X-ray beam, egg hatching was completely inhibited. When L. trifolii pupae were irradiated, the emergence rate decreased with increasing doses of X-ray irradiation. After F. intonsa adults were irradiated with 250 Gy of electron beam and 200 Gy of X-ray beam, egg hatching of the $F_1$ generation was completely suppressed.

ZVS Phase-Shift Full-Bridge Inverter for 100kV High Voltage Output of X-ray driving Circuit (X-ray 구동회로의 100kV 고전압 출력을 위한 ZVS Phase-shift Full-Bridge 인버터)

  • Kang, Kyung-soo;Kim, Se-min;Kim, Sang-Yeon;Lee, Jeong-jun;Roh, Chung-Wook
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.355-356
    • /
    • 2016
  • 기존 X-ray용 인버터의 경우, 일반적인 Full-bridge 인버터를 사용하여 낮은 효율이 발생하기 때문에 1.6kW이상의 고전압 출력을 요구하는 X-ray를 사용할 수 없는 문제점이 있다. 본 논문은 X-ray 구동용 인버터의 높은 출력이 가능한 고전압 출력용 ZVS Phase-Shift Full Bridge 인버터를 제안한다. 기존의 X-ray 구동용 인버터를 사용할 경우에는 낮은 효율 및 높은 출력 전압을 발생 시킬 수 없기 때문에 X-ray 발생이 어려우며, 높은 출력을 발생시키기 위해서는 회로의 전체적인 부피가 커지고 제작단가가 증가하는 단점이 있다. 반면 제안된 회로는 X-ray 구동용 ZVS Phase-Shift Full Bridge 인버터로써, 영전압 스위칭을 통해 높은 효율로 인버터 구동이 가능하고, 높은 출력 전압을 발생 시킬 수 있기 때문에 회로의 소형화 및 고출력 X-ray 발생이 가능한 장점을 갖는다. 본 논문에서는 제안된 회로의 이론적인 특성을 분석하고 모의실험을 통해 확인하였으며, 1.6kW급 X-ray 구동 인버터 회로에 적용하여 실험을 통해 우수성을 검증하였다.

  • PDF

Analysis of efficiency of X-ray equipment for medical service (의료용 X-ray 기기의 성능평가)

  • Kim, Tae-Gon;Kim, Toung-Pyo;Lee, Ho-Sic;Park, Yong-Pil;Cheon, Min-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.426-426
    • /
    • 2009
  • Diagnostic X-ray system is general and basic medical equipment to be used in mostly medical organizations, but being bombed of radioactivity is a big weak point when irradiates a X-ray to the human body so that ICRP restricted the radiation exposure tolerance of the human body. In order to reduce being bombed, the many research and development is now advanced. A lots of diagnostic X-ray machines have currently used due to the increase of occurrence efficiency of X-ray and precisely the output control by using the inverter which is a high speed switching semiconductors. For getting the confidence of the X-ray machine, the same radiation occurrence, same evaluation, and same irradiation condition are necessary when evaluates X-ray irradiation. It is the most important part for the accuracy of the test result and the patient safety. This paper has produced the high voltage occurrence system of full-wave rectification method by using the LC resonance inverter, and evaluated the irradiation reproducibility in order to use it in diagnosis of the patient.

  • PDF

Design of High Frequency Resonant Inverter Type X-Ray Generator (고주파 공진형 인버터식 X선 발생장치의 설계)

  • Lee, Seong-Gil;Park, Su-Gang;Baek, Hyeong-Rae;Jeong, Su-Bok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.1
    • /
    • pp.34-39
    • /
    • 2002
  • Most X-ray generator had been used do rectifier type transformer high tension generator which is supplied in a clinical diagnosis. But it is difficult to miniaturize and become light weight. Also, because the ripple rate of tube voltage is high, X-ray generating efficiency is very low. Therefore, it is supplied gradually from abroad being developed high tension generator for inverter type X-ray generator which use semi-conductor switching element for electric power that have high speed switching ability to solved these problem. But, semi-conductor element of big capacity are used by X-ray tube's big consumption power and diffusion is difficult in the small size hospital because production cost is ascending by doing digital control through DSP and product price becomes expensive. Therefore, in this paper, design and manufactured CR type voltage divider for feedback control of tube voltage of high frequency resonance type inverter and high tension transformer for high frequency to apply economical diffusion type X-ray generator which have wide output voltage and load extent. It is Proved do X-ray generator and stability of X-ray tube's output characteristics through an experiment.

A Study on the Gonads Exposure Dose of Upper Extremity Examinations in Sitting Position (앉은 자세 상지 X-ray 검사(Sitting Position Upper Extremity X-ray Examinations)에서 피폭선량 저감화 연구)

  • Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.34 no.3
    • /
    • pp.189-193
    • /
    • 2011
  • Sitting position upper extremity X-ray examinations (SUEX) is the most widely used patient positioning method for upper extremity X-ray examinations. For this method, the radiation dose is considerable for relatively less interesting organs. We investigated whether patients need to wear the apron during the examination or not. We also studied the examination methods which can reduce the radiation dose. The results showed that radiation dose was reduced as the distance of source to patient becomes longer and the thickness of object grows higher.