• 제목/요약/키워드: Rating Frequency Weight

검색결과 29건 처리시간 0.028초

현행 중량바닥충격음 평가방법 개선을 위한 주관평가실험 (Subjective Assessment of Simulated Heavy Floor Impact Sounds for Alternative Rating Method)

  • 신훈;백건종;송민정;장길수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.581-586
    • /
    • 2008
  • This study aims to examine the existing single rating index in terms of level reduction limit of heavy-weight floor impact sound. To achieve this goal, sounds which have same loudness according to rating methods were suggested to subjects. And followings are results. 1) The rating method of measurement frequency level average is more suitable than that of other methods which are dependent on specific frequency for rating heavy-weight floor impact sound. 2) Level average for measurement frequency of 31.5Hz - 500Hz is more correspondent to psycho-acoustic response than that of measurement frequency of 63Hz - 500Hz which is for KS F 2863-2, existing rating method.

  • PDF

현행 중량바닥충격음 평가방법 개선을 위한 주관평가실험 (Subjective Assessment of Simulated Heavy Floor Impact Sounds for Alternative Rating Method)

  • 신훈;김선우;장길수
    • 한국소음진동공학회논문집
    • /
    • 제19권3호
    • /
    • pp.282-287
    • /
    • 2009
  • This study aims to examine the existing single rating index in terms of level reduction limit of heavy-weight floor impact sound. To achieve this goal, sounds which have same loudness according to rating methods were suggested to subjects. And followings are results. 1) The rating method of measurement frequency level average is more suitable than that of other methods which are dependent on specific frequency for rating heavy-weight floor impact sound. 2) Level average for measurement frequency of $31.5\;Hz{\sim}500\;Hz$ is more correspondent to psycho-acoustic response than that of measurement frequency of $63\;Hz{\sim}500\;Hz$ which is for KS F 2863-2, existing rating method.

바닥충격음 평가방법 중 단일수치평가량과 dB(A) 비교 (Comparison of Rating Methods for the Floor Impact Noise)

  • 박철용;장동운
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.612-615
    • /
    • 2006
  • In this study, we compared and analyzed the floor impact noise insulation performance produced by the rating methods. The rating methods are using reversed A-weighting curve, A-weighted sound pressure levels(dB(A)). The results of this study are(1)dB(A) by the specified frequency is 0.5dB(A) at light weight and 2.5dB(A) at heavy weight upper than all pass dB(A)(2)the rating using reversed A-weighting curve is 5dB lower than dB(A)(3)the number of rating using reversed A-weighting curve mainly depends on impact noise pressure level of 63Hz in heavy weight but dB(A) does not.

  • PDF

평점 빈도 가중치 기반 기준선 예측기의 추천 성능 향상을 위한 편향 기반 추천기 (Bias-Based Predictor to Improve the Recommendation Performance of the Rating Frequency Weight-based Baseline Predictor)

  • 황태규;김성권
    • 정보과학회 논문지
    • /
    • 제44권5호
    • /
    • pp.486-495
    • /
    • 2017
  • 협업 필터링(CF, Collaborative Filtering)은 추천을 수행하기 위해 필요한 비용(시간/공간 복잡도 등)이 현실 데이터에 적용하기에는 한계가 있다. 평점 빈도 가중치 기반의 Baseline Predictor(RFWBP, Rating Frequency Weight-based Baseline Predictor)는 정확도가 기존의 방법과 근사하며, 비용을 크게 줄일 수 있는 효율적인 방법 중 하나이다. 그러나 효율성을 고려해 RFWBP만 사용할 경우, 1)학습을 수행하지 않기 때문에 발생되는 오차를 감소시킬 수 없고, 2)적합한 추천 목록을 작성하기 위한 조건이 없기 때문에 모두 추천했다. 본 논문은, 제시된 문제를 해결하기 위한 BBP(Bias-Based Predictor)를 제안한다. BBP는 Bias를 보정하여 오차의 범위를 감소시킴으로써 1)을 해결했고, 선호에 적합한 추천 목록 작성을 위한 몇 가지 Case를 정하고, 추천 목록을 구성함으로써 2)를 해결하였다.

공동주택 중량바닥충격음 현장측정을 통한 차단성능 평가방법의 비교검토 연구 (A Study of Rating Method Comparison for Heavy-weight Floor Impact Sound based on the Field Test Data in Apartment Houses)

  • 신훈;백건종;국찬;송민정;김선우
    • KIEAE Journal
    • /
    • 제10권5호
    • /
    • pp.187-194
    • /
    • 2010
  • Heavy-weight floor impact sound insulation performance criteria have been effective in Korea since the regulation which enforces the standard thickness of slabs in domestic apartment houses should be constructed by 180mm or 210mm was adopted. But every slab does not satisfy this criteria. So, review on existing floor impact sound insulation performance is needed to propose some basic materials for the revision of rating method. To achieve this goal, 63 field test data were checked and analyzed. The results of this study are as follows ; 1) The 210mm thickness slab has the characteristics of deeper level decrease above 120Hz frequency band than that of 180mm thickness slab's. 2) 27.5% of 180mm thickness slabs were satisfied the floor impact sound insulation performance criteria, whereas 65% of 210mm slabs do. 3) Among the main contribution frequency bands for the determination of single rating index, 63Hz was shown as the most contributive band in 210mm slabs. 4) In comparison of single rating index between bang machine test and ball test. there is a big difference between the two and this phenomenon is frequent in 210mm slab results. 5) Rating Methods for the analysis of cross-correlation between the amount of rating, the usefulness of the arithmetic mean could be secured.

직접추정법의 대칭적인 들기 작업의 최대허용하중 결정에의 적용에 관한 연구 (A study on applying the direct estimation method to determining maximum acceptable weight in symmetric lifting task)

  • 이관석;박희석
    • 대한인간공학회지
    • /
    • 제14권1호
    • /
    • pp.1-7
    • /
    • 1995
  • In this paper, the effectiveness and accuracy of using the direct estimation method were investigated in determining a worker's lifting capacity or the maximum acceptable weight of lifting (MAWOL) of symmetrical fifting tasks in the workplace were investigated. Six lifting tasks involving two vertical fifting start-end points (0-80cm, 47-102cm) and three lifting frequencies (1, 2, and 4 lifts/minute) were studied. Ten young, male subjects performed the six lifting tasks to predict the MAWOL using the psychophysical method and the direct estimation method. The main results indicated that there were no significant differences between the MAWOLs determined by the two methods except for the lifting frequency of 4 lifts/minute. Analysis of variance was performed on the task rating data to check the consistency of the task rating across subjects, which revealed no significant difference.

  • PDF

임팩트 볼에 의한 바닥충격음 측정 및 평가 간편법 (Simplified method on measurement and evaluation of floor impact sound using impact ball)

  • 김용희;이신영;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.631-635
    • /
    • 2006
  • In this study, simplified methods on measurement and evaluation of heavy-wight impact sound was proposed due to provide easy quality control method to construction engineers. The simplified methods include using of rubber impact ball instead of bang machine, reduced number of measuring and impact positions which is prescribed as over 4 points, using of hand-held sound level meter as a frequency analyser and prediction equation for $L_{i.Fmax.AW}$, single number rating, using $L_{Amax}$, and $L_{Lmax}$ at each frequency band. The results showed that a method of boundary driving and boundary measuring is the most similar to the current rating method.

  • PDF

바닥충격음 측정 및 차음 평가의 방향 (Improvement of Floor Impact Noise Measurement and Method for Rating Floor Impact Noise Isolation Performance)

  • 정정호;정영;서상호;송희수;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.269-274
    • /
    • 2004
  • The aims of this study were to Investigate the floor impact noise isolation performance of floating floor with isolation materials and propose the improvement direction of floor impact noise measurement method and evaluation classes using impact ball. Reduction of light-weight impact sound pressure level can be achieved by the finishing materials, such as vinyl finishing material and wooden flooring with isolation materials. Floor impact noise Isolation material which satisfy the properties of the floor impact noise isolation materials cause resonance in the low frequency band and worsen heavy-weight impact sound pressure level. Heavy-weight impact sound level can be reduced by using noise reduction flooring, ceiling and increase of slab thickness. Strong impact force in low frequency bang below 63Hz of bang machine is not similar to human impact source and causes some problem in evaluating heavy-weight impact noise but heavy-weight impact noise measurement and evolution using impact ball which is very similar to human impact is more reliable than bang machine. Correction value on the background noise and sensitivity of residents should be considered on the floor impact noise evaluation classes.

  • PDF

고주파링크 방식의 계통연계형 태양광발전시스템 (High frequency Linked Grid-Connected PV System for Residential Use)

  • 정영석;유권종;이수홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1281-1283
    • /
    • 2001
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system(3-5kW) that interface with a 220V single phase utility connection. As the result of this investigation, a 3kW high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors a net size, weight, and parts cost saying result compared to the other systems due to elimination of 60Hz transformer.

  • PDF

고주파링크 방식을 이용한 계통연계형 태양광발전시스템 (High frequency Linked Grid-Connected PV System for Residential Use)

  • 정영석;유권종;이수홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.467-469
    • /
    • 2001
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system(3-5kW) that interface with a 220V single phase utility connection. As the result of this investigation, a 3kW high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier, four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors, a net size, weight, and parts cost saving result compared to the other systems due to elimination of 60Hz transformer.

  • PDF