• Title/Summary/Keyword: Rated current line

Search Result 56, Processing Time 0.029 seconds

Characteristics Analysis for Reactor Starting Method of 3-Phase Induction Motor Considering Saturation (포화성분을 고려한 3상 유도전동기 리액터 기동 특성 분석)

  • Kim, Jong-Gyeum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.65-70
    • /
    • 2012
  • Induction motor is the most widely used to obtain the driving force in the industrial site. Induction motor generates a high current at startup. Most of starting currents are often more than five times of rated current. This high starting current can cause problems such as the voltage drop in the system. In order to solve these problems, if the motor capacity is large, generally we use reactor starting method rather than direct on line starting method. When a high startup current passes through reactor, reactor can serve as a nonlinear elements. In this study, we analyzed that the current, torque and power of the induction motor are different from the change of linear and nonlinear components of the reactor magnetic field.

The Design Simulation of the Levitation Magnet for the Urban Transit Maglev as the Running Vehicle on Curved Line(60mR) (자기부상열차의 곡선주로(60mR) 주행 시를 고려한 부상용 전자석 설계 Simulation)

  • Kim, Bong-Seop
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.682-684
    • /
    • 2002
  • There is much room for consideration that the magnet design of UTM. When the vehicle runs 60mR curved line on test track, the ratio of cross section area changed to cross the magnet pole and rail. The ratio is reduced about 20% of the total magnet on one bogie. Therefor, magnet current is increased about 3.5A to maintain constant air gap. This paper suggest to margin of the magent design is 1.1 rather than rated levitation force.

  • PDF

Analytical Investigations on the Figures of Meander Lines on the YBCO Thin Film for Resistive Fault Current Limiters (YBCO 박막형 저항형 한류기에 적용 가능한 Meander Line 해석 연구)

  • 이방욱;강종성;박권배;오일성;현옥배
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.221-224
    • /
    • 2002
  • Superconducting electrical devices are under development in a national project in Korea. And KEPCO and LGIS are in charge of development of a resistive type fault current limiters(FCLs) with YBCO thin films. In order to realize FCLs, the rated power of FCLs must be increased. For this purpose, it is of great interest to increase of allowed voltage of unit component without electrical and thermal damages. So, meander lines were widely used for the conducting path to increase maximum electric field. In this research, numerical simulations on the electromagnetic behaviors of the device were carried out, especially focusing on the effect of meander line structures on the YBCO thin films. To evaluate the structures of meander lines, three types of meander lines were considered for numerical analysis using finite element method (FEM). In this simulation, both normal state and fault conditions were considered for calculation of electric field, current density, magnetic field density. And the simulation resulted are compared to find the optimum design of meander lines for resistive FCLs.

  • PDF

PWM current source converter and inverter system for induction motor drives (유도전동기 구동을 위한 전류형 PWM 컨버터 및 인버터 시스템)

  • 이동춘
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.5
    • /
    • pp.159-164
    • /
    • 1996
  • In this paper, a novel control strategy of curretn source PWM converter and inverter system for induction motor dirves is proposed. The PWM converter controls line current to be sinusoidal and makes input power factor unity. In the inverter part, a minor voltage control loop is incorporated in the current control looop in order to suppress unstale resonance between the filter capacitor and the motor leakage inductance and to keep the stator voltage under the rated value. In additon, the modulation index control of the inverter currents ripples and inverter loss. With the proposed algorithm, both high dynamic responses and satisfactory static performance can be obtained.

  • PDF

Comparison of Three-Phase Voltage-Source PWM Converters Using a Single Current Sensor (단일 전류 센서를 사용한 3상 전압형 PWM 컨버터의 제어 방식 비교)

  • Lee, Woo-Cheol;Lee, Taeck-Kie;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.4
    • /
    • pp.188-200
    • /
    • 2001
  • This paper presents a technique for reconstructing converter line currents using the information from a single current sensor in the DC-link for voltage-source PWM converters. When three-Phase input currents cannot be reconstructed, three methods to acquire the input current are compared. Two of them are methods of modifying the switching state (I, II), another is a method of using the predictive state observer. Also, compensation of sampling delay, and a simultaneous sample value of input currents in the center of a switching period are included. Suitable criteria for the comparison are identified, and the differences in the performance of these methods are investigated through experimental results for a typical V-S PWM converter rated at 10kVA.

  • PDF

Design & characteristics of impulse current test system for station class(up to class 5) (송변전급(up to class 5) Impulse current test system의 설계 및 특성)

  • Kim, Seok-Sou;Choi, Ike-Sun;Kang, Young-Sik;Park, Byung-Rak;Park, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1146-1149
    • /
    • 2004
  • A new developed impulse current test system(100kV, 250kJ)is presented, which can carry out all impulse current and performance tests on surge arrester sections with rated voltage up to 12kV according to IEC 60099-4(2001). The maximum achievable peak value is 200kA for the impulse current $4/10{\mu}s$ and 60kA for the $30/80{\mu}s$ and $8/20{\mu}s$. The long duration current impulse is realized from class 1 to class 5. The digital transient recorder(4 channels 60MS/S 10bit) is used for measuring AC voltage, impulse current, reference voltage and leakage current. The complex control, measuring, evaluation and data storage system is controlled by one industrial PC system.

  • PDF

Job Perception and the Need for Job Improvement among School Nutrition Teachers in Seoul (서울지역 일부 학교 영양교사의 직무에 대한 인식과 개선 요구도)

  • Kim, Seoung-Hee;Lee, Kyung-Eun;Kim, Jin-Sook
    • Korean Journal of Community Nutrition
    • /
    • v.21 no.1
    • /
    • pp.12-24
    • /
    • 2016
  • Objectives: The objectives of the study were to investigate the school nutrition teachers' perception on their job and to find out recommendations needed for its improvement in order to provide a quality foodservice and nutrition education at schools. Methods: A total of 219 school nutrition teachers in Seoul were surveyed using selfadministered questionnaires. Results: The perceived importance of the 16 job duties was rated 3.8 based on a 5-point scale (1: very unimportant - 5: very important). The importance of six duties including nutrition management, production management, nutrition education, and food safety management were rated over 4 point but that of record-keeping for documents, official reporting, and service management was rated the lowest. Importance-Performance Analysis showed that nutrition management, receiving/storage management, production management, menu management, food safety management, and equipment/facilities management should be emphasized to maintain the current performance of duties. The performance of the nutrition education and counseling needed to be improved since the importance scores were greater than average but the performance scores were lower than the average. Official reporting and miscellaneous jobs were rated the highest for simplification need. More than half of the respondents agreed that equipment/facilities management, miscellaneous jobs, service staff supervision, and service line supervision could be allocated to other school departments. Conclusions: School nutrition teachers should invest more time and resources on their core job duties such as nutrition management, production management, food safety management, and nutrition education for providing quality foodservice and nutrition education. To reflect the environmental changes of school foodservice, a reasonable staffing index of school nutrition teachers needs to be developed. In addition, hiring an assistant or implementing school nutrition teacher internship programs can be useful to reduce workloads of the nutrition teachers.

Fuzzy Technique based Chopper Control for Slip Energy Recovery System with Twelve-Pulse Converter

  • Tunyasrirut, S.;Ngamwiwit, J.;Furuya, T.;Yamamoto, Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.509-514
    • /
    • 2004
  • This paper introduces the modified slip energy recovery system in order to improve its power factor and to reduce harmonics of line current waveforms. Twelve pulse line commutated converter with the chopper type IGBT is applied where the chopper is applied across the DC terminal and the chopped DC is fed to the converter operating as an inverter and then passed through the wye-wye and delta-wye transformer circuit. This scheme leads to be able to adjust the speed of the motor by the duty cycle of the chopper operating in PWM mode. The fuzzy logic controller is also introduced to the modified slip energy recovery system for keeping the motor speed to be constant when the load varies. The experimental results in testing the 0.22 kW wound rotor induction motor from no-load condition to rated condition show the effectiveness of the proposed control scheme.

  • PDF

A analysis result on the application of HSGS to the 765 kV transmission line according to it's length (765 kV 계통의 송전선로 거리에 따른 HSGS 적용에 관한 연구)

  • Woo, J.W.;Shim, E.B.;Kim, J.H.;Kim, B.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2069-2072
    • /
    • 1999
  • The extended 765 kV system may have severe electrical transients according to the interconnection of transmission lines and have long transmission line over 250 km. So we need to analyze the transient phenomena to confirm the insulation coordination which is designed for 765 kV project step I. In particular, this paper shows the analysis results of secondary arc extinction by HSGS (high speed ground switch) application. The EMTP/MODELS were used to simulation study of secondary arc phenomena. We had confirmed the TRV(transient recovery voltage) and rated current of HSGS which will be used in the KEPCO 765 kV system.

  • PDF

Arcing horn design specification and electrical characteristics special quality estimation of distribution line (배전선로의 내뢰흔 설계사양 및 전기적 특성 평가)

  • Kim, Seok-Sou;Choi, Ik-Sun;Park, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.472-473
    • /
    • 2007
  • This study evaluated electrical characteristics of the manufactured arcing horn whose rated voltage and nominal discharge current were 18kV and 2.5kA, respectively. In this study, residual voltage and lightning impulse flashover voltage were examined. The arcing horn showed excellent electrical characteristics that residual voltage and lightning impulse flashover voltage were 55kV below and 121kV at 115mm, respectively. Therefore the manufactured arcing Horn is considered that it would show good performance for protecting electrical wires and line post insulators from lightning impulse, if it were applied to real fields.