• Title/Summary/Keyword: Rate Test

Search Result 13,503, Processing Time 0.039 seconds

Parameter Estimation of the Two-Parameter Exponential Distribution under Three Step-Stress Accelerated Life Test

  • Moon, Gyoung-Ae;Kim, In-Ho
    • Journal of the Korean Data and Information Science Society
    • /
    • v.17 no.4
    • /
    • pp.1375-1386
    • /
    • 2006
  • In life testing, the lifetimes of test units under the usual conditions are so long that life testing at usual conditions is impractical. Testing units are subjected to conditions of high stress to yield informations quickly. In this paper, the inferences of parameters on the three step-stress accelerated life testing are studied. The two-parameter exponential distribution with a failure rate function that a log-quadratic function of stress and the tempered failure rate model are considered. We obtain the maximum likelihood estimators of the model parameters and their confidence regions. A numerical example will be given to illustrate the proposed inferential procedures.

  • PDF

A study on the characteristics of heart rate variability of patients with vasovagal syncope by tilt-table test (기립경사도 검사에 의한 실시환자의 심박변동신호 특성에 관한 연구)

  • 이정환;박찬석;이병채;김준수;이명호
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.561-564
    • /
    • 1998
  • This paper evaluated autonomic nervous system function in 23 patients with syncope and a positive tilt test result, 21 with a negative test result, and 19 healthy controls. Indexes of heart rate variability were measured during supine resting, immediately afte rtilt-up, standing rsting, immediately before syncope and immediately after tiltdown. There were no significant differences among the groups in any of the indexes of heart rate varability over the 24-hour holter recordings. In patients with a positive tilt result, tilting gaused a decrease in low-frequency (LF) immediately before syncope and incsrease in high-frequency (HF) bands immediately before. In patients with a negative tilt result, tilting caused a decrease in low-frequency (LF) immediately before syncope and decrease in high-frequency (HF) bands immediately before, different from positive tilt results. Our findings showed that patients with vasovagal syncope have no chronic differences from normal subjects in autonomic nervous system activity, but that these patients respond differently to the orthostatic stimulus.

  • PDF

Corrosion Evaluation of Epoxy-Coated Bars by Electrochemical Impedance Spectroscopy

  • Choi, Oan-Chul;Park, Young-Su;Ryu, Hyung-Yun
    • International Journal of Concrete Structures and Materials
    • /
    • v.2 no.2
    • /
    • pp.99-105
    • /
    • 2008
  • Southern exposure test specimens were used to evaluate corrosion performance of epoxy-coated reinforcing bars in chloride contaminated concrete by electrochemical impedance spectroscopy method. The test specimens with conventional bars, epoxy-coated bars and corrosion inhibitors were subjected 48 weekly cycles of ponding with sodium chloride solution and drying. The polarization resistance obtained from the Nyquist plot was the key parameter to characterize the degree of reinforcement corrosion. The impedance spectra of specimens with epoxy-coated bars are mainly governed by the arc of the interfacial film and the resistance against the charge transfer through the coating is an order of magnitude higher than that of the reference steel bars. Test results show good performance of epoxy-coated bars, although the coatings had holes simulating partial damage, and the effectiveness of corrosion-inhibiting additives. The corrosion rate obtained from the impedance spectroscopy method is equivalent to those determined by the linear polarization method for estimating the rate of corrosion of reinforcing steel in concrete structures.

Dynamic Behavior Characteristic Test of Structural Aluminium Alloy Materials using SHPB (SHPB를 이용한 구조용 AL합금재의 동적거동 특성 시험에 관한 연구)

  • Hur, S.;Kim, D.S.;Koo, J.S.;Kang, H.S.;Hong, S.I.;Chung, D.T.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.419-423
    • /
    • 2001
  • It is important to know the mechanical properties of the materials under dynamic load. The mechanical properties of most materials are influenced to some extent by strain rate. One of the reliable test device for determining the mechanical properties of materials at high strain rate is Split Hopkinson Pressure bar. In this paper, we conducted the mechanical properties test for the aluminium alloy 6063 and 6061 using the SHPB device.

  • PDF

Sensitivity of Daphnia magna to the Toxic Materials by the static Test (Static Test에 의한 Daphnia magna의 환경오염물질에 대한 민감성 평가)

  • 한의정;최성헌;김진일
    • Journal of environmental and Sanitary engineering
    • /
    • v.9 no.2
    • /
    • pp.101-109
    • /
    • 1994
  • Acute toxicity of heavy metals( mercury, cadmium lead, chromium and copper ), organophosphours insecticides( EPN, 2, 4- D, and parathion ), and other chemicals( arsenic, cyanide, and phenol ) to Daphnia magna was analyzed. Acute toxicity of heavy metals, organophosphours insecticides and other chemicals on Daphnia magna, LC$_{50}$ was showed 0.07-0.73mg/1, 0.22-1.94mg/t and 1.73-39.92mg/1 respectively. Daphnia magna to most of toxic chemicals was sensitive and then it seems to be useful except phenol in toxic test of water. Toxic chemicals were classified as Group 1 which had a high LC$_{50}$ value and the low increase rate of toxicity according to the increase of concentration, Group 2 which had a high LC$_{50}$ value and the high increase rate of toxicity, Group 3 which had a low LC$_{50}$ value and the low increase rate of toxicity. To Daphnia magna, lead, chromium, EPN, and parathion were included in Group 1; Mercury and copper in Group 2; Arsenic and cadmium in Group 3; Cyanide 2,4- D, and phenol in Group 4.

  • PDF

Multiple Testing in Genomic Sequences Using Hamming Distance

  • Kang, Moonsu
    • Communications for Statistical Applications and Methods
    • /
    • v.19 no.6
    • /
    • pp.899-904
    • /
    • 2012
  • High-dimensional categorical data models with small sample sizes have not been used extensively in genomic sequences that involve count (or discrete) or purely qualitative responses. A basic task is to identify differentially expressed genes (or positions) among a number of genes. It requires an appropriate test statistics and a corresponding multiple testing procedure so that a multivariate analysis of variance should not be feasible. A family wise error rate(FWER) is not appropriate to test thousands of genes simultaneously in a multiple testing procedure. False discovery rate(FDR) is better than FWER in multiple testing problems. The data from the 2002-2003 SARS epidemic shows that a conventional FDR procedure and a proposed test statistic based on a pseudo-marginal approach with Hamming distance performs better.

Experimental Study of Floor Impact Sound Insulation by the Finishing Materials and Porous Ratio of Insulations of Floor Structure in Mock-up Test Room (모형실험실에서 바닥충격음 완충재의 발포율 및 바닥마감재의 변화에 따른 충격음 차단성능에 대한 실험적 연구)

  • 김태희;오진균;신일섭;조창근
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.756-759
    • /
    • 2003
  • It is increasing the interest on the comfortable dwelling environment and the efforts to solve the problem of the floor impact noise in apartment houses have been realized, as a result numerous products have been made. The purpose of this study is to investigate the sound insulation performances according to foaming rate of floor impact noise insulators and flooring coverings in Mock-up Test Room. The test results of impact insulation performance for each floor impact noise insulators is that double structure of insulator is excel than one in low-middle frequency band and as foaming rate go up, the sound insulation performance is improved.

  • PDF

Adsorption of Heavy Metal Ions(Cadmium etc.) using Chitosan Bead (Chitosan Bead를 이용한 Cd등의 중금속 이온의 흡착제거)

  • 권성환;김기환;장문석;유재근
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.3
    • /
    • pp.21-27
    • /
    • 1996
  • Chitosan is a natural polyelectrolytic compound. Researches of adsorption capacity using chitosan have been doing actively. We prepared bead type gel, simple modifier of chitosan, And then experimented adsorption test of heavy metals (Cd etc) using it. According to the result adsorption capacity of chitosan bead was five times higher than chitosan powder. Removal rate of cadmium resulted 90% over in the test that initial concentration of Cd was 100mg/L and bead dosage was 6g/100mL. Adsorption type of heavy metals was similar to general adsorption curve. And optical pH range was 4 - 10 in the adsorption test. In the experiments of other heavy metals (Pb, Zn, Cu, Mn) adsorption types had two stages, highly removal rate-stage at the short time (20minutes) and then slow rate-stage at the after. And removal efficiency at the variable pH ranges revealed relatively good.

  • PDF

Corrosion Fatigue Cracking of Low Alloy Steel in High Temperature Water

  • Lee, S.G.;Kim, I.S.;Jang, C.H.;Jeong, I.S.
    • Corrosion Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.93-97
    • /
    • 2003
  • Fatigue crack growth test or low alloy steel was performed in high temperature water. Test parameters were dissolved oxygen content. loading frequency and R-ratio ($P_{min}/P_{max}$). Since the sulfur content or the steel was low, there were no environmentally assisted cracks (EAC) in low dissolved oxygen(DO) water. At high DO, the crack growth rate at R = 0.5 tests was much increased due to environmental effects and the crack growth rate depended on loading frequency and maximized at a critical frequency. On the other hand, R = 0.7 test results showed an anomalous decrease of the crack growth rate as much different behavior from the R = 0.5. The main reason of the decrease may be related to the crack tip closure effect. All the data could be qualitatively understood by effects of oxide rupture and anion activity at crack tip.

Development of Flow Control Valves for Hot Water Distribution Manifolds (온수분배기용 유량제어밸브의 개발)

  • Kwon, Woo-Chul;Yoon, Joon-Yong;Yoo, Sun-Hak
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.4
    • /
    • pp.11-17
    • /
    • 2010
  • The developed control valves, installed on the hot water distribution manifolds for the floor heating system, consist of the balancing valves and the shut-off valves. The balancing valve was designed to improve the flow control performance and to reduce the noise emitted from the valve by modification of the general V port. The port of the shut-off valve was designed with two ceramic plates, working by rotating upper plate, to improve the duration and to reduce the noise. For the evaluation of the new valves, the flow rate was measured and noise level test was carried out. The test results showed that the error of the flow rate accuracy test for the flow balance of each manifold circuit was less than ${\pm}3%$ and the noise level was less than 35 dB(A).