A 10-year-old male neutered Labrador Retriever presented with a history of acute-onset tachypnoea, lethargy and anorexia. The dog was pyrexic, tachypnoeic and dyspnoeic on examination. A rapid antigen test for severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) was performed on an oropharyngeal swab and yielded a positive result. SARS-CoV-2 infection was subsequently confirmed by reverse transcription polymerase chain reaction (RT-PCR) analysis. Both of the dog's owners had positive rapid antigen test and RT-PCR analysis results for SARS-CoV-2. Additional diagnostics included computed tomography. Resolution of the dog's clinical signs was achieved with symptomatic treatment.
Lee, Young Hwa;Bang, Ji Hwan;Park, Sang Min;Kang, Cho Ryok;Cho, Sung-Il;Oh, Myoung-don;Lee, Jong-Koo
Journal of Korean Medical Science
/
v.33
no.46
/
pp.304.1-304.7
/
2018
Background: The Republic of Korea has a very low prevalence of human immunodeficiency virus (HIV) infection, but the number of new HIV diagnoses has steadily risen, strongly indicating a large number of undetected HIV infections. Thus, it is important for Korean public health authorities to adopt and encourage cost-effective HIV detection tools, such as rapid HIV screening tests. In this study, we aimed to evaluate the cost-effectiveness of enzyme-linked immunosorbent assays (ELISA) and rapid tests in a public health center (PHC) setting. Methods: We developed a decision analytic model to assess the per-examinee cost and the cost-effectiveness of identifying HIV patients in a PHC setting using two HIV testing strategies: conventional HIV screening by ELISA versus rapid HIV testing. Analysis was performed in two scenarios: HIV testing in an average-risk population and in a high-risk population. Results: Compared to the ELISA, the rapid test was cost-saving and cost-effective. The per-examinee cost was USD 1.61 with rapid testing versus USD 3.38 with ELISA in an average-risk population, and USD 4.77 with rapid testing versus USD 7.62 with ELISA in a high-risk population. The cost of identifying a previously undiagnosed HIV case was USD 26,974 with rapid testing versus USD 42,237 with ELISA in an average-risk population, and USD 153 with rapid testing versus USD 183 with ELISA in a high-risk population. Conclusion: Rapid testing would be more cost-effective than using conventional ELISA testing for identifying previously undiagnosed HIV-infected cases in Korea, a country with extremely low HIV prevalence.
Journal of the Architectural Institute of Korea Structure & Construction
/
v.34
no.5
/
pp.13-18
/
2018
In this research, regarding the type three blast furnace slag (BS) regulated by KS F 2563 and supplied to actual ready mixed concrete plant, the fineness on specification and actually measured fineness by Blain test were compared, and by applying the hydrometer method used for early prediction of concrete strength, the feasibility of the hydrometer method for acquisition inspection of BS was analyzed. Additionally, the influence of various fineness of BS on properties of cement mortar was also assessed. According to the experimental results of this research, correlation of fineness values between specification and actually measured data were not matched. In the case of the rapid evaluation method using hydrometer, a good relation was shown between the fineness data obtained from hydrometer and Blain test. furthermore, from the cement mortar properties test, there was a good relation was obtained between fineness data from rapid evaluation method by hydrometer and cement mortar properties, while there was no clear relation between fineness data from specification and cement mortar properties. Hence, as a qulity controlling method of BS fineness, a rapid evaluation method using hydrometer is suggested as a new method.
The infection rate of syphilis is still increasing in the world especially in developing countries and the infection is often seen in large amounts of clinical specimens. For the diagnosis of this disease, Rapid Plasma Reagin (RPR)/Venereal Disease Research Laboratory (VDRL) has still been used as one of major primary methods to diagnose syphilis even though the test readings are somewhat subjective with high false positive rates. Recently, the automatic ARCHITECT Syphilis TP, which is based on the detection of the TP-specific antibodies, has been introduced in many laboratories. Therefore, the clinical assessment of the method is needed to provide primary diagnosis of syphilis at the moment. We evaluated 3 different manual rapid kits and ARCHITECT Syphilis TP comparing with RPR/FTA-ABS and analysed their diagnostic properties. From February 2006 to April 2008, 203 positive and 250 negative specimens, obtained from Chungbuk National University Hospital were used for the evaluation. In the evaluation between manual rapid kits, their specificities were as high as 99.2 ~ 99.6% while their sensitivities were observed with little differences; 98.0% (199/203) for Kit A, 96.6% (196/203) for Kit B, and 97.4% (197/203) for Kit S. In the case of ARCHITECT Syphilis TP test, it showed 100% specificity (250/250) and 98.5% sensitivity (249/250). Kappa values comparing with RPR/FTA-ABS were 0.978 for Kit A, 0.964 for Kit B and Kit S, and 0.987 for ARCHITECT Syphilis TP. From our evaluation, we found out that manual rapid tests and ARCHITECT Syphilis TP have very good clinical accuracies and high kappa agreements with RPR/FTA-ABS. Due to its automation and quick simultaneous diagnosis with another serological markers, we suggest that the ARCHITECT Syphilis TP is one of best suitable method for the primary diagnosis of syphilis and that it might be able to replace RPR method in the laboratories.
In the manufacturing processes of semiconductor, test process is important for quality of products. In the manufacturing process of dynamic memory, memory test is more important. So, automatic test equipment(ATE) is used necessarily. But, according to increase of speed of dynamic memory operation, the rapid test equipment is needed. Impedance matching between ATE and dynamic memory is expected to be an important problem for making a rapid test equipment over 1Gbps. According to increase of speed, inner impedance of ATE also works on important parameter for test. This paper is about the method that is for impedance matching of inner impedance and coaxial cable occurring in manufacturing of ATE. We proved effects of inner impedance by electric theory and verified the method of impedance matching using computer simulation.
Proceedings of the Korea Concrete Institute Conference
/
2006.11a
/
pp.601-604
/
2006
Reinforcement corrosion is the most important durability problem of reinforced concrete structures. One of the important factors affecting the steel corrosion is carbonation. However, existing carbonation test takes several months to obtain the results. Therefore, in this study, new rapid carbonation test equipment for concrete was developed and its applicability was investigated. The testing period can be reduced by increasing $CO_2$ concentration up to 100% in the equipment. It is found from the test results that the carbonation depth of concrete specimens tested for 2 weeks was $3{\sim}5$ times greater than that of specimens tested by existing test method. In conclusion, it would be possible to get the reliable test results enough to evaluate the durability of concrete structures in a short-period.
Background: Although the Quidel Sofia rapid influenza fluorescent immunoassay (FIA) is widely used to identify influenza A and B, the diagnostic accuracy of this test remains unclear. Thus, the objective of this study was to determine the diagnostic performance of this test compared to reverse transcriptase-polymerase chain reaction. Methods: A systematic literature search was performed using MEDLINE, EMBASE, and the Cochrane Central Register. Pooled sensitivity, specificity, diagnostic odds ratio (DOR), and a hierarchical summary receiver-operating characteristic curve (HSROC) of this test for identifying influenza A and B were determined using meta-analysis. A sensitivity subgroup analysis was performed to identify potential sources of heterogeneity within selected studies. Results: We identified 17 studies involving 8,334 patients. Pooled sensitivity, specificity, and DOR of the Quidel Sofia rapid influenza FIA for identifying influenza A were 0.78 (95% confidence interval [CI], 0.71-0.83), 0.99 (95% CI, 0.98-0.99), and 251.26 (95% CI, 139.39-452.89), respectively. Pooled sensitivity, specificity, and DOR of this test for identifying influenza B were 0.72 (95% CI, 0.60-0.82), 0.98 (95% CI, 0.96-0.99), and 140.20 (95% CI, 55.92-351.54), respectively. The area under the HSROC for this test for identifying influenza A was similar to that for identifying influenza B. Age was considered a probable source of heterogeneity. Conclusion: Pooled sensitivities of the Quidel Sofia rapid influenza FIA for identifying influenza A and B did not quite meet the target level (≥80%). Thus, caution is needed when interpreting data of this study due to substantial betweenstudy heterogeneity.
Journal of the Korea Academia-Industrial cooperation Society
/
v.20
no.11
/
pp.44-55
/
2019
This study was undertaken to examine changes in the performance of nurses before and after initial cardiac arrest, and compare the performance, confidence, and satisfaction between two groups: group 1, Rapid Cycle Deliberate Practice simulation method; group 2, traditional simulation method. The participants were 122 nurses (group 1: 62, group 2: 60). Data were collected from March 18 to 29, 2019 and analyzed using the SPSS Version 23.0 program, by applying descriptive statistics, Fisher's exact test, t-test, Wilcoxon sign rank test, and Mann-Whitney U-test. Comparing the educational effects of the traditional simulation training vs. RCDP simulation training, some items of performance were significantly different (z=-2.02, p=0.044 / z=-2.42, p=0.015 / z=-3.03, p=0.002), but no difference was observed in the levels of confidence (z=0.388, p=0.699) and satisfaction (t=0.72, p=0.476) between the two groups. This study confirms that both training methods are effective teaching modules for enhancing the nurse's ability to perform resuscitation with confidence. Hence, we suggest applying the appropriate simulation method, according to the subjects included during education, and contents in the training of Advanced Life Support for nurses. Effectiveness of the modules can be ascertained by applying the RCDP simulation training method in various fields.
Helicobacter pylori(H. pylori) is the causative agent of chronic gastritis and the single most important factor in peptic ulcer disease, however, the pathogenetic mechanisms underlying H, pylori infection are not well understood. Futhermore, there is a strong association between H. pylori infection and gastric cancer. Various diagnostic methods for detecting H. pylori infection are available. These can be divided into invasive methods, requiring endoscopy, and non-invasive tests, mainly 13C-urea breath tests and serologic detection of antibodies. Rapid urease test is the most recommendable endoscopic test for the diagnosis of H. pylori infection, presently. CLO test kit is the represent of rapid urease test kits. The principles of CLO test kit is that hydrolysis of urea by urease Is detected by a dye indicators showing a color change. Our device is used same principle but we improved the reaction time is more faster and positive color change is more distinctive from the color of the negative specimen. So, this kit is more reliable because it response faster and accuracy.
Of critical importance to the success of any e-commerce site are the two factors: rapid application development and quick response time. A three-tier architecture composed of presentation layer, business layer, and data access layer emerges to allow rapid changes in user interface, business logic, and database structures. Too often, such a logical three-tier architecture is considered as requiring a three-tier physical architecture: Web server, application server, and database server running on separate computers. Contrary to the common belief, a Web stress test reveals that the three-tier logical architecture implemented on a two-tier physical platform guarantees a quicker response time due to the reduction in cross-machine communications. This would lead business firms to economize their spending on e-commerce: increasing the number of physical servers to expedite transaction is not necessarily the best solution. Before selecting a particular hardware configuration, a Web stress test needs to be conducted to compare the relative merits of alternative physical architectures. Together with capacity planning, Web stress test emerges as a powerful tool to build robust, yet economical e-commerce sites.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.