• Title/Summary/Keyword: Rapid antigen test

Search Result 92, Processing Time 0.034 seconds

Evaluation of a Rapid Immunochromatography Technique for Determination of Cd in Soils and Rice Grains (면역크로마토그래피를 이용한 토양 및 쌀의 Cd 간이진단법 평가)

  • Lee, Sang-Phil;Kim, Rog-Young;Abe, Kaoru;Kim, Sung-Chul;Kim, Won-Il;Yang, Jae E.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.6
    • /
    • pp.900-903
    • /
    • 2012
  • Cadmium is known to be very toxic to human health and can be relative easily translocated from soils in plants. Therefore, a rapid method for screening Cd in soils and crops has become more and more important. For this reason, we examined a rapid immunochromatograpy (ICG) test kit which uses antigen-antibody reaction based on immunoassay and chromatography. Soils and rice grains collected from mine waste-contaminated sites were determined for their Cd contents using this kit. For comparison purposes, 0.1 M HCl and ICP-OES were employed as a conventional extraction and determination method. Cadmium contents in rice grains determined using ICG technique were $0.46{\sim}2.39mg\;kg^{-1}$ and Cd contents determined using 0.1 M HCl and ICP-OES were $0.52{\sim}1.97mg\;kg^{-1}$. The correlation between these two Cd contents were statistically significant ($r^2$=0.930). The results of Cd contents in soils also showed a statistically significant relationship between these two methods ($r^2$=0.975). On the basis of these results, ICG technique can be applied to rapidly quantify Cd in crops and soils. However, further research is necessary to apply ICG technique for the field screening.

Comparison of the non-invasive diagnostic methods, stool antigen test and PCR assay, for Helicobacter felis detection in dogs

  • Hong, Sunhwa;Lee, Hak-Yong;Kim, Tae-Wan;Kim, Okjin
    • Korean Journal of Veterinary Service
    • /
    • v.38 no.1
    • /
    • pp.37-42
    • /
    • 2015
  • The aim of the present study was to compare the non-invasive methods for the diagnosis of H. felis with HpSA kit-based detection method and H. felis-specific PCR assay with dog's stool samples without sacrifice. Male Beagle dogs (n=6) were infected with H. felis ATCC 49179 ($1.0{\times}10^9CFU/dog$) by intra-gastric inoculation two times at 3-day intervals, and the stool specimens of dogs were collected 1, 3, 5, 7, 14, 21 days after infection to submit to HpSA test and H. felis-specific PCR. As the results, the sensitivity of the HpSA and the PCR analysis was 50.0%, 83.3% respectively. Although HpSA test is less sensitive, it could be used for rapid, cheap and easy screening assay for H. felis infection in dog and cats. We suggest that the H. pylori stool antigen kit, HpSA, is useful and effective for monitoring H. felis infection. If HpSA test would be made with H. felis antibodies in the future, its sensitivity could be increased. Also, PCR assay could be successfully used to detect the H. felis in stools. Applying the H. pylori stool antigen kit and PCR assay may be the recommended non-invasive strategy to identify H. felis in dog and cats.

Development of Automated Rapid Influenza Diagnostic Test Method Based on Image Recognition (영상 인식 기반 신속 인플루엔자 자동 판독 기법 개발)

  • Lee, Ji Eun;Joo, Yoon Ha;Lee, Jung Chan
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.3
    • /
    • pp.97-104
    • /
    • 2019
  • To examine different types of influenza diagnostic test kits automatically, automated rapid influenza diagnostic test method based on image recognition is proposed in this paper. First, the proposed methods classify a variety of the rapid influenza diagnostic test kit based on support vector machine that analyzes the kits' feature point. Then, to improve the accuracy of test, the proposed methods match the histogram of both the target image of influenza kit and the input image of influenza kit for minimizing the effect of environment factors, such as lighting and exposure variations. And, to minimize the effect from composition of the hand-helds devices, the proposed methods extract the feature point and match point-by-point between target image of influenza kit and input image of influenza kit. Experimental results of 124 experimental group show that the proposed methods significantly have effectiveness, which shows 90% accuracy in moderate antigen, for the preliminary examination of influenza, and provides the opportunity for taking action against influenza.

Dot-Blot Immunoassay of Fasciola gigantica Infection using 27 kDa and Adult Worm Regurge Antigens in Egyptian Patients

  • Kamel, Hanan H.;Saad, Ghada A.;Sarhan, Rania M.
    • Parasites, Hosts and Diseases
    • /
    • v.51 no.2
    • /
    • pp.177-182
    • /
    • 2013
  • The purpose of the present study was to evaluate the potential role of the 27-Kilodalton (KDa) antigen versus Fasciola gigantica adult worm regurge antigens in a DOT-Blot assay and to assess this assay as a practical tool for diagnosis fascioliasis in Egyptian patients. Fasciola gigantica antigen of an approximate molecular mass 27- (KDa) was obtained from adult worms by a simple elution SDS-PAGE. A Dot-Blot was developed comparatively to adult worm regurge antigens for the detection of specific antibodies from patients infected with F. gigantica in Egypt. Control sera were obtained from patients with other parasitic infections and healthy volunteers to assess the test and compare between the antigens. The sensitivity, specificity, positive and negative predictive values of Dot-Blot using the adult worm regurge were 80%, 90%, 94.1%, and 69.2% respectively, while those using 27-KDa were 100% which confirms the diagnostic potential of this antigen. All patients infected with Fasciola were positive, with cross reactivity reported with Schistosoma mansoni serum samples. This 27-KDa Dot-Blot assay showed to be a promising test which can be used for serodiagnosis of fascioliasis in Egyptian patients especially, those presenting with hepatic disease. It is specific, sensitive and easy to perform method for the rapid diagnosis particularly when more complex laboratory tests are unavailable.

Optimized Expression, Purification, and Rapid Detection of Recombinant Influenza Nucleoproteins Expressed in Sf9 Insect Cells

  • Yoon, Sung-Jin;Park, Young-Jun;Kim, Hyun Ju;Jang, Jinwoo;Lee, Sang Jun;Koo, Sunwoo;Lee, Moo-Seung
    • Journal of Microbiology and Biotechnology
    • /
    • v.28 no.10
    • /
    • pp.1683-1690
    • /
    • 2018
  • Accurate and rapid diagnosis of influenza infection is essential to enable early antiviral treatment and reduce the mortality associated with seasonal and epidemic infections. Immunochromatography is one of the most common methods used for the diagnosis of seasonal human influenza; however, it is less effective in diagnosing pandemic influenza virus. Currently, rapid diagnostic kits for pandemic influenza virus rely on the detection of nucleoprotein (NP) or hemagglutinin (HA). NP detection shows higher specificity and is more sensitive than HA detection. In this study, we time-dependently screened expression conditions, and herein report optimal conditions for the expression of recombinant nucleoprotein (rNP), which was 48 h after infection. In addition, we report the use of the expressed rNP in a rapid influenza diagnostic test (SGT i-flex Influenza A&B Test). We constructed expression vectors that synthesized rNP (antigen) of influenza A and B in insect cells (Sf9 cells), employed the purified rNP to the immunoassay test kit, and clearly distinguished NPs of influenza A and influenza B using this rapid influenza diagnostic kit. This approach may improve the development of rapid test kits for influenza using NP.

Application of monoclonal antibody to develop diagnostic techniques for infectious bovine rhinotracheitis virus. II. Diagnosis of infectious bovine rhinotracheitis by using monoclonal antibody (소 전염성비기관염(傳染性鼻氣管炎) 바이러스에 대한 monoclonal antibody 생산(生産)과 진단법(診斷法) 개발 II. Monoclonal antibody를 이용한 소 전염성비기관염(傳染性鼻氣管炎)의 진단(診斷))

  • Jun, Moo-hyung;Kim, Duck-hwan;An, Soo-hwan;Lee, Jung-bok;Min, Won-gi
    • Korean Journal of Veterinary Research
    • /
    • v.29 no.1
    • /
    • pp.27-35
    • /
    • 1989
  • To develop more specific and sensitive diagnostic methods for infectious bovine rhinotracheitis, 7-C-2 monoclonal antibody specific to polypeptides of infectious bovine rhinotracheitis virus (IBRV) was applied in indirect immunofluorescence antibody assay (IFA), indirect immunoperoxidase assay(IPA) and radial immunodiffusion enzyme assay (RIDEA). It was found that IBRV infected in MDBK cells could be detected as early as 8 hours post infection by IFA, and that IFA was more rapid and specific to identify IBRV antigen than IPA. The diagnostic efficacy of RIDEA and SN test was studied with 88 bovine sera. It was evident that RIDEA could eliminate the false positive reaction encountered in serum neutralization(SN) test, being more rapid and sensitive than the latter. Highly significant correlation coefficiency (r=0.76, p<0.01) was evaluated between the titers of sera and the diameters of RIDEA. Tracheal membranes and sera collected from 96 slaughtered cattle with lesions in respiratory organs were examined to detect IBRV antigen and antibody by IFA, RIDEA and SN test. It was presented that positive rates were 32.3% in IFA, 20.8% in RIDEA and 21.9% in SN test, and that coincidence rate between RIDEA and SN test were 100% in positive sera and 98.7% in negative sera. In conclusion, it was assumed that application of monoclonal antibody could improve the diagnostic efficacy of IBR by enhancing sensitivity and specificity of IPA, IFA and RIDEA.

  • PDF

Studies on the Rapid Plasma Reagin(RPR) Card Test for the Diagnosis of Syphilis (매독진단(梅毒診斷)을 위(爲)한 신속(迅速)한 혈장항체검사법(血漿抗體檢査法)에 관(關)한 연구(硏究))

  • Kim, Joo-Deuk;Lew, Joon;Kim, Hyun-Joo
    • The Journal of the Korean Society for Microbiology
    • /
    • v.3 no.1
    • /
    • pp.15-23
    • /
    • 1968
  • For the effective control of Syphilis, many investigators have developed a more rapid, simple and economical screening serological test which is adequately sensitive and specific. To fulfill the requirements of a more rapid serologic test for syphlis, a substitute for the conventional serum specimen was needed since considerable time and labor are involved in the processing of blood to serum. Burdon suggested the use of plasma in the serologic tests for syphilis as a substitute for serum. He noticed that plasma was more sensitive than serum in the Kline and Kahn tests, and attributed this to the presence of more antibody-like substance, "reagin" in plasma than in serum. However, to make plasma sufficiently sensitive, it was necessary to inactivate plasma by heating at a temperature of $56^{\circ}C$ for about 30 minutes. Heating of plasma resulted in the precipitation of fibrinogen which made centrifugation necessary to obtain dear plasma. Since the chief disadvantage to the use of unheated plasma(or serum) was a reduction in sensitivity of results-which probably was due to a labile factor such as complement-Portnoy et al began to consider rapid chemical methods of inactivation of plasma(or serum). They experienced that choline chloirde was shown to be anticomplementary which suggested its use as an inactivating agent for unheated plasma(or serum). In 1959 Portnoy et al reported the Rapid Plasma Reagin(RPR) Test for syphilis which is a more rapid, economical and simple. But still this test has many disadvantages as a rapid performing, field and office procedure, because it requires the usual laboratory equipments such as centrifuge, rotating machine, microscope etc. To substitute these disadvantages of the RPR test, in 1962, Portnoy et al developed the Rapid Plasma Reagin(RPR) card test for syphilis, which has the following advantages: a) Simplicity and rapidity of performance, b) Requires no laboratory equipments, c) Stable antigen suspension, d) Adequate sensitivity and specificity. This RPR card test can be used as a rapidly performing and screening test in field investigation, outpatient clinics, small laboratories and hospitals doing limited syphilis serology, and predonor in blood bank. Private clinic which has limited laboratory equipment and technic for syphilis serology can also use this RPR card test as a tool in the rapid diagnosis of syphilis. It was thought that this RPR card test is a useful tool in Korea for private physician and mass survey for syphilis diagnosis. But Portnoy patented the reagents needed for the performing the RPR card test. Therefore authors developed newly the reagents and according to Portnoy's method evaluated the newly developed. RPR card test compared with the VDRL, Kolmer CF, and RPCF tests. The RPR card and VDRL tests were performed plasma and serum from the total 1,132 cases. Among these 1,131 cases, 521 were syphilis suspected laboratory specimens, and 611 were syphilis unsuspected healthy young men. After screening with these two tests, the RPR card and VDRL tests, reactive specimens to the above one or both tests were retested by the Kolmer CF and RPCF tests.

  • PDF

Development and Clinical Evaluation of a Rapid Serodiagnostic Test for Toxoplasmosis of Cats Using Recombinant SAG1 Antigen

  • Chong, Chom-Kyu;Jeong, Woo-Seog;Kim, Hak-Yong;An, Dong-Jun;Jeoung, Hye-Young;Ryu, Jeong-Eun;Ko, A-Ra;Kim, Yong-Joo;Hong, Sung-Jong;Yang, Zhaoshou;Nam, Ho-Woo
    • Parasites, Hosts and Diseases
    • /
    • v.49 no.3
    • /
    • pp.207-212
    • /
    • 2011
  • Rapid serodiagnostic methods for Toxoplasma gondii infection in cats are urgently needed for effective control of transmission routes toward human infections. In this work, 4 recombinant T. gondii antigens (SAG1, SAG2, GRA3, and GRA6) were produced and tested for the development of rapid diagnostic test (RDT). The proteins were expressed in Escherichia coli, affinity-purified, and applied onto the nitrocellulose membrane of the test strip. The recombinant SAG1 (rSAG1) showed the strongest antigenic activity and highest specificity among them. We also performed clinical evaluation of the rSAG1-loaded RDT in 182 cat sera (55 household and 127 stray cats). The kit showed 0.88 of kappa value comparing with a commercialized ELISA kit, which indicated a significant correlation between rSAG1-loaded RDT and the ELISA kit. The overall sensitivity and specificity of the RDT were 100% (23/23) and 99.4% (158/159), respectively. The rSAG1-loaded RDT is rapid, easy to use, and highly accurate. Thus, it would be a suitable diagnostic tool for rapid detection of antibodies in T. gondii-infected cats under field conditions.

The Evaluation of Immunochromatographic Assay kit for Rapid Detection of Hepatitis B Surface Antigen (Hepatitis B Surface Antigen을 신속히 검출하기 위한 Immunochromatographic Assay kit의 성능 평가)

  • Shin, Hyeong-Soon;Kim, Young-Bong;Shin, Jung-Woo;Kim, Chang-Kyu;Lee, Wang-Sik;Kim, Han-Kyeom;Shin, Kwang-Soon
    • The Journal of Korean Society of Virology
    • /
    • v.27 no.2
    • /
    • pp.137-141
    • /
    • 1997
  • We evaluated Immunochromatographic assay kit to screen HBsAg in human serum. When the reference HBsAg was applyed to ICA, HA and EIA kits, the limit of detection for HBsAg were found out to be 4, 2 and 0.25 ng/ml respectively. But ICA kit required 5 minutes to read the result whereas HA and EIA kit more than one hour. The sensitivity was 97% (29 of 30 samples) and the specificity 100% (45 samples) compared with conventional EIA. The ICA kit needs no instrument or machine to perform the test contrary to the conventional methods. Therefore, this rapid and sensitive ICA kit can be used for HBsAg-screening, especially in the emergency room and in the scene of the accident.

  • PDF

Diagnostic Significance of the Serologic Test Using Multiple Antigens of Mycobacterium Tuberculosis by ELISA (다양한 특이결핵항원을 이용한 결핵항체 검사(ELISA)의 진단적 유용성)

  • Kim, Dae-Yun;Choi, In-Hwan;Park, Seung-Kyu;Cho, Shang-Rae;Song, Sun-Dae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.6
    • /
    • pp.757-767
    • /
    • 1999
  • Background: Diagnosis by smear and/or cultures of the Mycobacterium tuberculosis from body fluid or biopsy specimen is "Gold standard". However the sensitivity of the direct microscopy is relatively low and culture of mycobacteria is time consuming. Despite an explosion in the techniques of rapid identification of mycobacteria by molecular genetic means, it is laborious and expensive and then rapid, inexpensive serodiagnosis is interested in diagnosis of tuberculosis. But sensitivity and specificity of known serologic antigen is not full sufficient level and then new antigen develop and combination cocktails of new developed antigens by ELISA are needed. Method: To compare the efficacy of different mycobacterial specific antigen and to assess the applicability of the combination of several different antigens in the diagnosis of tuberculosis, five ELISA tests derived 14KDa, 16KDa, 19KDa, 23KDa, 38KDa were evaluated in 57 active pulmonary patient and 24 inactive post-therapy follow up patient and 48 normal control. Results: The optical densities of ELISA test with 14KDa, 16KDa, 19KDa, 23KDa, 38KDa were significantly higher in active tuberculosis cases than in normal control(P<0.001, P<0.001, P<0.027, P<0.001, P<0.001) and those with 16KDa, 38KDa were significant higher in active tuberculosis cases than in inactive post-therapy follow up cases(P<0.01. P<0.001) and those of 14KDa, 16KDa, 23KDa, 38KDa were significant higher in inactive post-therapy follow up cases than in normal control(P<0.008. P<0.01. P<0.006. P<0.001). The sensitivity of 14KDa, 16KDa, 19KDa, 23KDa, 38KDa in active pulmonary patient cases was 42.1%, 43.9%, 15.8%, 28.0%, 70.2%, respectively and the specificity of 14KDa, 16KDa, 19KDa, 23KDa, 38KDa in active pulmonary patient cases was 95.8%, 95.8%, 91.7%, 89.6%, 93.8%, respectively. The sensitivity and specificity of combination 38KDa with 16KDa was 87% and 93.7%. Conclusion: The sensitivity and specificity of new antigens for serodiagnosis of the tuberculosis still remains limited at around 70%, which makes its a poor diagnostic tool for disease confirmation. A combination of cocktail antigens provided by cut-off value adjustment for serodiagnosis of tuberculosis some improved diagnostic yield than single antigen serologic test.

  • PDF