• 제목/요약/키워드: Range of variation

Search Result 3,245, Processing Time 0.031 seconds

A Study on Dielectric Properties of Printed Circuit Board Materials with Variation of Frequency and Temperature (온도 및 주파수 변화에 따른 프린트 배선기판의 유전특성 연구)

  • 박종성;김종헌;이준웅
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.10
    • /
    • pp.773-777
    • /
    • 1998
  • This paper presents the results of measured permittivity of PCB sheet material in the frequency range of 0.1 ~ 2[㎓] and temperature range of 25~ 85[>$^{\circ}C$]. Microstrip lines with different physical length are implemented to measure the attenuation and phase shift of the signals through these lines. The loss factor of glass-epoxy and teflon could by calculated with the measured dielectric constant and the attenuation. From the experiment, the glass-epoxy was more influenced by temperature and frequency than teflon. The average dielectric constants of glass-epoxy and teflon within the measured frequency range are 4.48 and 2.18, respectively.

  • PDF

An Evaluation of Liquid Chromatography/Mass Specrometry with Atmospheric Pressure Chemical Ionizarion for the Rapid and Simultaneous Measurement of Carbamate Pesticides and Organophosphorus Pesticides

  • Kim, Byeong Ju;So, Hyeon Yeong
    • Bulletin of the Korean Chemical Society
    • /
    • v.21 no.5
    • /
    • pp.471-476
    • /
    • 2000
  • Liquid chromatography/mass spectrometry with an atmospheric pressure chemical ionization interface (LC/APCI/MS) is evaluated for the simultaneous determination of carbamate pesticides and organophosphorus pesticides in a single chromatographic analysis. APCI mass spectra of those compounds were obtrained to study their ionization characteristics. APCI provided abundant ions such as protonated molecules and characteristic fragment ions for carbamate pesticides and organophosphorus pesticides. To evaluate the feasibility of the LC/APCI/MS for a routine quantitative analysis, the linearity and repeatability of LC/APCI/MS were examined by measuring standard solution mixtures of five carbamate pesticides and four organophosphorus pesticides over the range of 1 to 100 ㎍/mL. Teh peak areas in chromatograms of characteristic ions for those compounds showed less than 3% of variation from run to run. The standard calibration curves for the nine pesticides show good linearity in the concentration range. The detection limits of the LC/APCI/MS system for those compounds range from 0.006 to 0.2 ng.

Continuous Viscosity Measurement of Non-Newtonian Fluids over a Range of Shear Rates Using a Mass-Detecting Capillary Viscometer

  • Sehyun Shin;Keum, Do-Young
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.255-261
    • /
    • 2002
  • A newly designed mass-detecting capillary viscometer uses a novel concept to continuously measure non-Newtonian fluids viscosity over a range of shear rates. A single measurement of liquid-mass variation with time replaces the now rate and pressure drop measurements that are usually required by capillary tube viscometers. Using a load cell and a capillary, we measured change in the mass flow rate through a capillary tube with respect to the time, m(t), from which viscosity and shear rate were mathematically calculated. For aqueous polymer solutions, excellent agreement was found between the results from the mass-detecting capillary viscometer and those from a commercially available rotating viscometer. This new method overcomes the drawbacks of conventional capillary viscometers meassuring non-Newtonian fluid viscosity. First, the mass-detecting capillary viscometer can accurately and consistently measure non -Newtonian viscosity over a wide range of shear rate extending as low as 1 s$\^$-1/. Second, this design provides simplicity (i. e., ease of operation, no moving parts), and low cost.

Reliability of Classical Linear Modeling in Dynamic Analysis of Flexible Structures (유연 구조물의 동적해석시 고전적 선형모델링의 신뢰성)

  • 유홍희
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.7
    • /
    • pp.1657-1664
    • /
    • 1995
  • For dynamic analysis of flexible structures, classical linear modeling has been widely used due to its several good aspects. However, it was found that the modeling often lost its accuracy. So, it is important to know the valid range of the modeling before it is used. more complicated modelings are needed to obtain reliable results only outside the valid range of the classical linear modeling. In this study, some rigid body motions of flexible structures which lead to the failure of the classical linear modeling are investigated. Hybrid deformation variable modeling, which is proved to be accurate in previous studies, is used to figure out the valid range of the classical linear modeling through numerical examples.

Bootstrap-Based Test for Volatility Shifts in GARCH against Long-Range Dependence

  • Wang, Yu;Park, Cheolwoo;Lee, Taewook
    • Communications for Statistical Applications and Methods
    • /
    • v.22 no.5
    • /
    • pp.495-506
    • /
    • 2015
  • Volatility is a variation measure in finance for returns of a financial instrument over time. GARCH models have been a popular tool to analyze volatility of financial time series data since Bollerslev (1986) and it is said that volatility is highly persistent when the sum of the estimated coefficients of the squared lagged returns and the lagged conditional variance terms in GARCH models is close to 1. Regarding persistence, numerous methods have been proposed to test if such persistency is due to volatility shifts in the market or natural fluctuation explained by stationary long-range dependence (LRD). Recently, Lee et al. (2015) proposed a residual-based cumulative sum (CUSUM) test statistic to test volatility shifts in GARCH models against LRD. We propose a bootstrap-based approach for the residual-based test and compare the sizes and powers of our bootstrap-based CUSUM test with the one in Lee et al. (2015) through simulation studies.

Concrete Construction with Specified Strength of 300~400kg/$\textrm{cm}^2$ by Use of Ready Mixed Concrete (레미콘에 의한 설계기준강도 300~400kg/$\textrm{cm}^2$ 콘크리트의 시공(지하3층, 지상36층 주상 복합빌딩에의 적용))

  • 이영철;한이수;박재우;장제욱
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.10a
    • /
    • pp.235-240
    • /
    • 1995
  • A 36 stories high multi-use building was designed with the specified concrete strength range of 300~400kg/$\textrm{cm}^2$ On the ground of the concept of compressive strength, adequate mix designing for the concrete, which has the target strength range of 390-520kg/$\textrm{cm}^2$, was carried out to provide enough strength margin. And with due regard to the workability and transportation time, the slump and slump flow ranged 16~21cm and 30~45cm respectively, maintaining these properties up to 2-hours from the beginning of the mix. The high-range water reducer is incorporated into the mix as a admixture. The building construction is controlled satisfactorily, so far. The actual average 28-day compressive strength is 370kg/$\textrm{cm}^2$, the standard deviation is 28kg/$\textrm{cm}^2$ and the coefficient of variation is 7.6% for concrete of 300kg/$\textrm{cm}^2$ specified strength.

  • PDF

Characteristics of Dynamic Strain Aging(DSA) in SA106Gr.C Piping Steel

  • Kim, Jin-Weon;Kim, In-Sup
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.771-776
    • /
    • 1995
  • Tensile and J-R tests were carried out to estimate the effects of dynamic strain aging(DSA) on SA106Gr.C piping steel. Tensile tests were performed under temperature range RT to $400^{\circ}C$ md strain rates from $1.39{\times}10^{-4}\;to\;6.95{\times}10^{-2}/s$. Fracture toughness was tested in the temperature range RT to $350^{\circ}C$ and load-line displacement rates 0.4 and 4mm/min. The effects of DSA on the tensile properties were clearly observed for phenomena such serrated flow, variation of ultimate and yield stress, and negative stram rate sensitivity. However, the magnitude of serration and strength increase by DSA was relatively small. this may be due to high ratio of Mn to C. In addition, crack initiation resistance, Ji and crack growth resistance, dJ/da were reduced in the range of $200-300^{\circ}C$, where DSA appeared as serrated flow and UTS hardening. The temperature corresponding to minimum fracture resistance was shifted to higher temperature with increasing loading rate.

  • PDF

Study of Boundary Tone in Mandarin Chinese (표준 중국어의 경계억양에 관한 연구)

  • Sohn Nam-Ho
    • Proceedings of the KSPS conference
    • /
    • 2003.05a
    • /
    • pp.43-47
    • /
    • 2003
  • This paper is phonetic study of $F_{0}$ range and boundary tone in Mandarin Chinese. The production data from 6 Chinese speakers show that there are declination, pitch resetting and tonal variation of boundary tone. In declarative sentence, $F_{0}$ declines gradually over the utterance but mid-sentence boundary prevents $F_{0}$ of following syllable from declining because of pitch resetting. $F_{0}$ range of syllable is expanded before the mid- and final sentence boundaries. In interrogative one, $F_{0}$ ascends gradually over the utterance and mid-sentence boundary makes $F_{0}$ of following syllable rise more. $F_{0}$ range of sentence final syllable is expanded and $F_{0}$ contour shows rising curve.

  • PDF

Experimental Study on the Performance Characteristics of the Diffuser as a Relation of the Variation of Vane Turning Angle (베인 회전각의 변화에 따른 디퓨저의 성능특성에 관한 실험적 연구)

  • Cho, Sung-Kook;Kang, Shin-Hyoung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.2 s.3
    • /
    • pp.74-80
    • /
    • 1999
  • Recently, impressive gains of performance and efficiency with apparently little or no loss in flow range have been seen with the use of LSVD(Low Solidity Vaned Diffuser) over vaneless diffuser. Experiments of the effects of the vane turning angle variations(positive, negative, zero), with the other design parameters fixed, on the performance and flow range were carried out. Diffusers with a zero turning angle have the best characteristics in terms of performance and efficiency and the FFT results show different frequency characteristics due to vane turning angles in low flow range.

  • PDF

A Study on the Wear Characteristics and the Mechanism of KP-4M Steel for Plastic Molding (플라스틱성형용 KP-4M강의 마멸특성 및 이의 기구에 관한 연구)

  • 박흥식;전태옥;김동호
    • Tribology and Lubricants
    • /
    • v.12 no.1
    • /
    • pp.22-28
    • /
    • 1996
  • This study was undertaken to investigate the dry wear characteristics and mechanism of KP-4M steel for plastic molding against SKD 61 hardened by heat treatment. The wear test was carried out under different conditions such as sliding speed, contact pressure, sliding distance, with frictional tester of pin on disc type. The wear loss on variation of sliding speed was little in lower speed range below 0.5 m/sec and in higher speed range above 1.5 m/sec,'but wear loss was high in intermediate speed range. The critical sliding speed, which showed the maximum value of specific wear rate, became lower with increased contact pressure. Increasing the contact pressure, the critical sliding distance Lcr which the wear mechanism changes from severe wear to mild wear was increased due to the decrease of oxidation reaction velocity. Through this study we suggested a model of generation and elimination process of wear debris of KP-4M steel for plastic molding.