• 제목/요약/키워드: Range Measurement

Search Result 4,376, Processing Time 0.039 seconds

Development of Work-related Musculoskeletal Disorder Questionnaire Using Receiver Operating Characteristic Analysis (Receiver Operating Characteristic 분석법을 이용한 업무관련성 근골격계질환 설문지 개발)

  • Kwon, Ho-Jang;Ju, Yeong-Su;Cho, Soo-Hun;Kang, Dae-Hee;Sung, Joo-Hon;Choi, Seong-Woo;Choi, Jae-Wook;Kim, Jae-Young;Kim, Don-Gyu;Kim, Jai-Yong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.32 no.3
    • /
    • pp.361-373
    • /
    • 1999
  • Objectives: Receive Operating Characteristic(ROC) curve with the area under the ROC curve(AUC) is one of the most popular indicator to evaluate the criterion validity of the measurement tool. This study was conducted to develop a standardized questionnaire to discriminate workers at high-risk of work-related musculoskeletal disorders using ROC analysis. Methods: The diagnostic results determined by rehabilitation medicine specialists in 370 persons(89 shipyard CAD workers, 113 telephone directory assistant operators, 79 women with occupation, and 89 housewives) were compared with participant's own replies to 'the questionnair on the worker's subjective physical symptoms'(Kwon, 1996). The AUC's from four models with different methods in item selection and weighting were compared with each other. These 4 models were applied to 225 persons, working in an assembly line of motor vehicle, for the purpose of AUC reliability test. Results: In a weighted model with 11 items, the AUC was 0.8155 in the primary study population, and 0.8026 in the secondary study population(p=0.3780). It was superior in the aspects of discriminability, reliability and convenience. A new questionnaire of musculoskeletal disorder could be constructed by this model. Conclusion: A more valid questionnaire with a small number of items and the quantitative weight scores useful for the relative comparisons are the main results of this study. While the absolute reference value applicable to the wide range of populations was not estimated, the basic intent of this study, developing a surveillance fool through quantitative validation of the measures, would serve for the systematic disease prevention activities.

  • PDF

Analyses of Synchronous Fluorescence Spectra of Dissolved Organic Matter for Tracing Upstream Pollution Sources in Rivers (상류 오염원 추적을 위한 용존 유기물질 Synchronous 형광스펙트럼 분석 연구)

  • Hur, Jin;Kim, Mi-Kyoung;Park, Sung-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.317-324
    • /
    • 2007
  • Fluorescence measurements of dissolved organic matter(DOM) have the superior advantages over other analysis tools for applying to water quality management. A preliminary study was conducted to test the feasibility of applying synchronous fluorescence measurements for tracing and monitoring pollution sources in a small stream located in an upstream area of the Sooyoung watershed in Busan. The water quality of the small stream is affected by leachate from sawdust pile and discharge of untreated sewage. The sampling sites included an upstream site, two pipes discharging untreated sewage, leachate from sawdust, and a downstream site. Of the five field samples, the leachate was distinguished from the other samples by a high peak at a lower wavelength range and a blunt peak at 350nm, suggesting that synchronous fluorescence can be used as a discrimination tool for monitoring the pollution. The efficacy of various indices derived from the spectral features to discriminate the pollution source was tested for well-defined mixture of the sawdust leachate and the upstream stream by comparing (1)the difference between measured values and those predicted based on mass balance and the characteristics of the two samples and (2)the linear correlations between index values and mass ratios of the sample mixtures. Of various discrimination indices selected, fluorescence intensities at 276 nm$({\Delta}\lambda=30nm)$and 347 nm$({\Delta}\lambda=60nm)$ were suggested as promising potential discrimination indices for the sawdust pollution source. Despite the limited number of samples and the study area, this study illustrates the evaluation process that should be followed to develop rapid, low-cost discrimination indices to monitor pollution sources based on end member mixing analyses.

Measurement of Progesterone in Plasma and Milk by RIA and CIA (RIA 및 CIA에 의한 혈장과 우유내 Progesterone 측정)

  • 이경찬
    • Korean Journal of Animal Reproduction
    • /
    • v.14 no.1
    • /
    • pp.57-65
    • /
    • 1990
  • These experiment were carried out ; (1) to investigate the changes of progesterone in plasma, whole milk and skim milk during oestrus cycle and pregnancy and ; (20) to evaluate a chemiluminescence Immunoassay(CIA) as an alternative method by measuring the progesterone concentration is skim milk by RIA and CIA. The results obtained in these experiments were summerized as follows ; 1. Plasma progesterone levels in non-pregnant Holstein during oestrus cycle were relatively low until day 8 after oestrus. And then, the progesterone level began to increase and reached a peak with 6.3ng/ml on day 14 and then declined repidly to 1.5ng/ml and 2.2ng/ml on day 18 and 20, respectively. 2. Whole milk progesterone level in pregnant Holstein increased from 1.0ng/ml on oestrus to 16.0ng/ml on day 8 and then remained from 11.0ng/ml on day 10 to 22.0ng/ml on day 22. 3. In non-pregnant Holstein, whole milk pregesterone lev디 was 1.5ng/ml on oestrus and began to increase rapidly from day 6 after oestrus and exhibited a ranged of levels, 17.8~20.0ng/ml from day 6 to day 16 after oestrus. 4. Skim milk progesterone levels in pregnant Holstein were a range of 130~490pg/ml at the time of estrus and began to increase continually till then showing constant levels ranging from 1300pg/ml on day 10 to 1650pg/ml on day 22. 5. In non-pregnant Holstein, skim milk progesterone level was 160pg/ml on oestrus and began to increase from 190pg/ml on day 2 after oestrus to day 8 and then keep constant levels ran ging from 1050 to 1300pg/ml from day 8 to day 16 and then decreased to 240~450pg/ml from day 18 to day 22 after oestrus. 6. The results obtained from CIA for the analysis of skim milk progesterone were in good agreement with the values derived by RIA.(r=0.914)

  • PDF

Identification and Measurement of Hospital-Related Fears in Hospitalized School-Aged Children (학령기 입원아동의 병원관련 공포에 관한 탐색연구)

  • 문영임
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.1
    • /
    • pp.61-79
    • /
    • 1995
  • When children are admitted to hospital, they have to adapt to new and unfamiliar stimuli. Children may respond with fear to stimuli such as pain or unfamiliar experiences. One goal of nursing is to help hospitalized children to adapt effectively to their hospital experience. Accordingly, nurses need to assess childrens' fears of their hospital experience to contribute to the planning of care to alleviate these fears. The problem addressed by this study was to identify and measure hospital-related fears(hereafter called HRF) in hospitalized school-aged children. The study was conceptualized with Roy's model. A descriptive qualitative approach was used first, followed by a quantitative approach. This study was conducted from November 30, 1989 to January 12, 1991. The sample consisted of 395 hospitalized school-aged children selected through an allocated sampling technique in nine general hospitals. The HRF questionnaire (three point likert scale ) was developed by a delphi technique. The data were analyzed by an SAS program. Factor analysis was used for the examination of component factors. Differences in the HRF related to demographic variables were examined by t-test, analysis of variance and the Scheffe test. The crude scores of the HRF scale were transformed into T- scores to calculate the standard scores. The results included the following : 1. Forty-four items were derived from 188 statements identifying the childrens' hospital-re-lated fears. These items clustered into 14 factors, fear of injections, operations, bodily harm others' pain, medical rounds, physical examinations, medical staff, disease process, blood and X-rays, drugs and cockroaches, tests, harsh discipline from parents or staff, being absent from school, and separation from family. The 14 factors was classified into four categories,'pain','the unfamiliar','the un-known' and 'separation'. 2. The reliability of the HRF instruments was .92(Cronbach's alpha). In the factor analysis, Cronbach's alpha coefficients for the 14 factors ranged from .84 to .86 and Cronbach's alpha coefficients for the four categories ranged from .70 to .84. Pearson correlation coefficient scores for relationships among the 14 factors ranged from ,11 to .50, and among the four categories, from ,44 to ,63, indicating their relative independence. 3. The total group HRF score ranged from 45 to 130 in a possible range of H to 132, with a mean of 74.51. The fears identified by the children were, in order, injections, harsh discipline by parents or staff, bodily harm, operations, medical staff, disease process, and medical rounds ; the least feared was others' pain. The fear item with the highest mean score was surgery and the lowest was examination by a doctor. HRF scores were higher for girls than for boys, and for grade 1 students than for grade 6 students. HRF scores were lower for children whose fathers were over 40 than for those whose fathers were in the 30 to 39 age group, and whose mothers were over 35 than for those whose mothers were in the 20 to 34 age group. HRF scores were lower when the mother rather than any other person stayed with the child. The expressed fear of pain, the unfamiliar, the un-known and of separation directs nurses' concern to the threat felt by hospitalized children to their concept of self. This study contributes to the assessment of fears of hospitalized children and of stimuli impinging on those fears. Accordingly, nursing practice will be directed to the alleviation of pain, pre-admission orientation to the hospital setting and routines, initiation of information about procedures and experiences and arrangments for mothers to stay with their children. Recommendations were made for further research in different settings and for development and testing of the instrument.

  • PDF

Performance Test of Portable Hand-Held HPGe Detector Prototype for Safeguard Inspection (안전조치 사찰을 위한 휴대형 HPGe 검출기 시제품 성능평가 실험)

  • Kwak, Sung-Woo;Ahn, Gil Hoon;Park, Iljin;Ham, Young Soo;Dreyer, Jonathan
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.54-60
    • /
    • 2014
  • IAEA has employed various types of radiation detectors - HPGe, NaI, CZT - for accountancy of nuclear material. Among them, HPGe has been mainly used in verification activities required for high accuracy. Due to its essential cooling component(a liquid-nitrogen cooling or a mechanical cooling system), it is large and heavy and needs long cooling time before use. New hand-held portable HPGe has been developed to address such problems. This paper deals with results of performance evaluation test of the new hand-held portable HPGe prototype which was used during IAEA's inspection activities. Radioactive spectra obtained with the new portable HPGe showed different characteristics depending on types and enrichments of nuclear materials inspected. Also, Gamma-rays from daughter radioisotopes in the decay series of $^{235}U$ and $^{238}U$ and characteristic x-rays from uranium were able to be remarkably separated from other peaks in the spectra. A relative error of enrichment measured by the new portable HPGe was in the range of 9 to 27%. The enrichment measurement results didn't meet partially requirement of IAEA because of a small size of a radiation sensing material. This problem might be solved through a further study. This paper discusses how to determine enrichment of nuclear material as well as how to apply the new hand-held portable HPGe to safeguard inspection. There have been few papers to deal with IAEA inspection activity in Korea to verify accountancy of nuclear material in national nuclear facilities. This paper would contribute to analyzing results of safeguards inspection. Also, it is expected that things discussed about further improvement of a radiation detector would make contribution to development of a radiation detector in the related field.

Critical Analyses of '2nd Science Inquiry Experiment Contest' (과학탐구 실험대회의 문제점 분석)

  • Paik, Seoung-Hey
    • Journal of The Korean Association For Science Education
    • /
    • v.15 no.2
    • /
    • pp.173-184
    • /
    • 1995
  • The purpose of this study was to analyse the problems of 'Science Inquiry Experiment Contest(SIEC)' which was one of 8 programs of 'The 2nd Student Science Inquiry Olympic Meet(SSIOM)'. The results and conclusions of this study were as follows: 1. It needs to reconsider the role of practical work within science experiment because practical work skills form one of the mainstays in current science. But the assessment of students' laboratory skills in the contest was made little account of. It is necessary to remind of what it means to be 'good at science'. There are two aspects: knowing and doing. Both are important and, in certain respects, quite distinct. Doing science is more of a craft activity, relying more on craft skill and tacit knowledge than on the conscious application of explicit knowledge. Doing science is also divided into two aspects, 'process' and 'skill' by many science educators. 2. The report's and checklist's assessment items were overlapped. Therefore it was suggested that the checklist assessment items were set limit to the students' acts which can't be found in reports. It is important to identify those activities which produce a permanent assessable product, and those which do not. Skills connected with recording and reporting are likely to produce permanent evidence which can be evaluated after the experiment. Those connected with manipulative skills involving processes are more ephemeral and need to be assessed as they occur. The division of student's experimental skills will contribute to the accurate assess of student's scientific inquiry experimental ability. 3. There was a wide difference among the scores of one participant recorded by three evaluators. This means that there was no concrete discussion among the evaluators before the contest. Despite the items of the checklists were set by preparers of the contest experiments, the concrete discussions before the contest were necessary because students' experimental acts were very diverse. There is a variety of scientific skills. So it is necessary to assess the performance of individual students in a range of skills. But the most of the difficulties in the assessment of skills arise from the interaction between measurement and the use. To overcome the difficulties, not only must the mark needed for each skill be recorded, something which all examination groups obviously need, but also a description of the work that the student did when the skill was assessed must also be given, and not all groups need this. Fuller details must also be available for the purposes of moderation. This is a requirement for all students that there must be provision for samples of any end-product or other tangible form of evidence of candidates' work to be submitted for inspection. This is rather important if one is to be as fair as possible to students because, not only can this work be made available to moderators if necessary, but also it can be used to help in arriving at common standards among several evaluators, and in ensuring consistent standards from one evaluator over the assessment period. This need arises because there are problems associated with assessing different students on the same skill in different activities. 4. Most of the students' reports were assessed intuitively by the evaluators despite the assessment items were established concretely by preparers of the experiment. This result means that the evaluators were new to grasp the essence of the established assessment items of the experiment report and that the students' assessment scores were short of objectivity. Lastly, there are suggestions from the results and the conclusions. The students' experimental acts which were difficult to observe because they occur in a flash and which can be easily imitated should be excluded from the assessment items. Evaluators are likely to miss the time to observe the acts, and the students who are assessed later have more opportunity to practise the skill which is being assessed. It is necessary to be aware of these problems and try to reduce their influence or remove them. The skills and processes analysis has made a very useful checklist for scientific inquiry experiment assessment. But in itself it is of little value. It must be seen alongside the other vital attributes needed in the making of a good scientist, the affective aspects of commitment and confidence, the personal insights which come both through formal and informal learning, and the tacit knowledge that comes through experience, both structured and acquired in play. These four aspects must be continually interacting, in a flexible and individualistic way, throughout the scientific education of students. An increasing ability to be good at science, to be good at doing investigational practical work, will be gained through continually, successively, but often unpredictably, developing more experience, developing more insights, developing more skills, and producing more confidence and commitment.

  • PDF

Comparison of Irradiated Food with Electron Beam and Gamma-ray by PSL and TL Methods (광자극발광법과 열발광법 분석을 통한 전자선과 감마선 조사식품의 비교 연구)

  • Kim, Kyu-Heon;Kwak, Ji-Young;Yoon, Jin-Ho;Park, Young-Eun;Lee, Jae-Hwang;Park, Yong-Chjun;Jo, Tae-Yong;Lee, Hwa-Jung;Lee, Sang-Jae;Han, Sang-Bae
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.3
    • /
    • pp.258-266
    • /
    • 2013
  • This study was conducted to determine the PSL and TL properties of foods irradiated with electron beam and gamma-ray. 5 kinds of food including cereal, pulse, fish powder, dried vegetable and tea were irradiated at 0 to 10 kGy by electron beam accelerator or $^{60}Co$ gamma-ray irradiator. The PSL analysis showed negative results for most of the non-irradiated samples. Non-irradiated shrimp powder showed intermediate result. Irradiated samples gave negative or intermediate or positive value which presented the limitation of PSL technique. In TL analysis, there were TL glow curves at around $300^{\circ}C$ with low intensity on non-irradiated samples. Maximum peak in the range of $150-250^{\circ}C$ was appeared on irradiated samples. TL ratio obtained by re-irradiation with 1 kGy was less than 0.1 on non-irradiated samples and higher than 0.1 on irradiated samples. Therefore, in PSL measurement, electron-beam irradiated samples could obtain more clear results. TL analysis showed obvious difference between non-irradiated and irradiated samples. But the identification was impossible for the sample of rice and lemon tea. Because of it's low contents of mineral.

Analysis of Age-related Distribution of the Tracheal Diameter and Cross-sectional Area Among Koreans -Compuerized Tomographic Measurement- (한국인의 연령별 기관 내경 및 단면적 분포에 대한 분석 -흉부전산화단층촬영을 이용한 측정-)

  • Lee, Gun;Kim, Dae-Sik;Moon, Seung-Chul;Koo, Won-Mo;Yang, Jin-Young;Lee, Hyeon-Jae;Lim, Chang-Young;Han, Hyeon;Kim, Kwang-Ho;Sun, Kyung
    • Journal of Chest Surgery
    • /
    • v.32 no.5
    • /
    • pp.442-447
    • /
    • 1999
  • Introduction: Understanding the normal distribution of the tracheal diameter and crross- sectional area is one of the key elements in the management of various tracheal pathologies or tracheal reconstruction for the patients in growing age. However, data for Korean standard has been lacking. This study was designed to analyze retrospectively the distribution of tracheal diameter and cross-sectional area in young Koreans, which can afford fundamental data for the management of tracheal diseases. Material and Method: Of the patients who underwent computerized tomogram of the chest between May 1996 and August 1998, one hundred six young patients(age range: 0-20 years) were included. Patients with any conditions which might affect the tracheal cross-sectional area or diameter, such as tracheal disease, previous operation, mediastinal tumor, or obstructive lung disease were excluded from the study. Gender distribution was 69 males and 37 females. Tracheal diameters, anterior-posterior and transverse, were measured at the level of the thoracic inlet(level I) and the aortic arch(level II). Types of the trachea were divided into round, oval, or horseshoe shaped on cross-sectional view, and the dimension was calculated by using the equation of A=1/4$\pi$ab(A; area, $\pi$; 3.14, a; anterior-posterior diameter, b; transverse diameter). We analyzed the distribution of the diameter at each level and compared the cross-sectional area with respect to age and gender. A p-value lower than 0.05 wa considered significant. Result: The trachea of patients less than 5 years old were round in shape at both of level I and II, and no differences in cross-sectional area was observed between the levels(p=NS). As the age increased, the trachea become oval in shape at level I while it remained round in shape at level II(p=0.020). The tracheal diameter and cross-sectional area increased as the age increased with a linear correlation(r>0.9). In patients less than 5 years of age, female patients showed larger cross-sectional area than male patients (p=0.020), and it was reversed in patients older than 15 years of age(p=0.002). Conclusion: From the above results, we suggest chest computerized tomogram as a safe and reliable tool in measuring the tracheal diameter and cross-sectional area. We also provide the data as a standard for distribution of the tracheal diameter and cross-sectional area in young Korean population.

  • PDF

Research on the Reduction of Exposure Dose of a Patient Having a PET/CT Exam (PET/CT 검사 환자의 피폭선량 경감을 위한 연구)

  • Kim, Bong-Su;Pyo, Sung-Jai;Cho, Yong-Gyi;Shin, Chai-Ho;Cho, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.10-16
    • /
    • 2009
  • Purpose: As the number of patients has increased since the installation of a PET/CT, we are now examining about 2500-3000 annually. We have realized that if we properly adjust a pitch under the same condition of a CT during a PET/CT exam, radiation quantity that reaches the patient can change. In order to reduce the exposure dose of a patient, the research examines a method of reducing the exposure dose of a patient by controlling the pitch during a PET/CT exam, viewing whether the adjustment of the pitch influences CT image and PET SUV. Methods: The equipment used is a Biograph Positron Emission Tomography (PET) Scanner (CT type: TRCT-240-130 (WCT-240-130)) of Siemens company. For the evaluation of exposure dose of a patient, we measured radiation quantities using a PTW-DIADOS 11003/1383, which is a CT radiation measurement instrument used by Siemens. We measured and analyzed the space resolutions of CT images caused by the change of pitches using an AAPM Standard Phantom in order to see how the adjustment of pitches influenced the CT images. In addition, in order to obtain SUVs caused by each change of pitches using a PET source made with a solid radioactive cylinder phantom, we confirmed whether the SUVs changed in the PET/CT images by calculating the SUVs of the fusion images caused by the change of pitches after obtaining CT and PET images and finishing the test. Results: 2slice CT scanner showed that radiation quantities largely dropped when pitches ranged from 0.7 to 1.3 and that the reduction of radiation quantities were smaller when pitches ranged from 1.5 to 1.9. That is, we found that the bigger pitch values are the smaller the radiation quantities of a patient are. Moreover, we realized that there is no change of SUVs caused by the increase of pitches and that pitch values do not influence PET SUVs and the quality of CT images. It is judged that using 1.5 as a pitch value contributes to the reduction of exposure dose of a patient as long as there is no problem in the quality of an image. Conclusions: When seeing the result of the research, hospital using a PET/CT should make an effort to reduce the exposure dose of a patient seeking pitch values appropriate for their hospital within the range in which there is no image distortion and PET SUVs are not influenced from pitches. We think that the research can apply to all multi-detectors having a CT scanner and that such a research will be needed for other equipments in the future.

  • PDF

Factors Affecting Wet-Paddy Threshing Performance (탈곡기의 제작동요인이 벼의생탈곡성능에 미치는 영향)

  • 남상일;정창주;류관희
    • Journal of Biosystems Engineering
    • /
    • v.5 no.1
    • /
    • pp.1-14
    • /
    • 1980
  • Threshing operation may be one of the most important processes in the paddy post-production system as far as the grain loss and labor requirement are concerned . head-feeding type threshers commercially available now in Korea originally were developed for threshing dry paddy in the range of 15 to 17 % in wet basis. However, threshing wet-paddy with the grain moisture content above 20 % has been strongly recommended, especially for new high-yielding Indica -type varieties ; (1) to reduce high grain loss incurred due to the handling operations, and (2) to prevent the quantitative and qualitative loss of milled -rice when unthreshed grains are rewetted due to the rainfall. The objective of this study were to investigate the adaptability of both a head-feeding type thresher and a throw-in type thresher to wet-paddy , and to find out the possiblilities of improving the components of these threshers threshing. Four varieties, Suweon 264 and Milyang 24 as Tongil sister line varieties, minehikari and Jinhueng as Japonica-type varieties, were used at the different levels of the moisture content of grains. Both the feed rate and the cylinder speed were varied for each material and each machine. The thresher output quality , composition of tailing return, and separating loss were analyzed from the sampels taken at each treatment. A separate experiment for measurement opf the power requirement of the head-feeding type thresher was also performed. The results are summarized as follows : 1. There was a difference in the thresher output quality between rice varieties. In case of wet-paddy threshing at 550 rpm , grains with branchlet and torn heads for the Suweon 264 were 12 % and 7 % of the total output in weight, respectively, and for the Minehikari 4.5 % and 2 % respectively. In case of dry paddy threshing , those for the Suweon 264 were 8 % and 5% , and for the Minehikari 4% and 1% respectively. However, those for the Milyang 23 , which is highly susceptable to shattering, were much lower with 1 % and 0.5% respectively, regardless of the moisture content of the paddy. Therefore, it is desirable to breed rice varieties of the same physical properties as well as to improve a thresher adaptable to all the varieties. Torn heads, which increased with the moisture content of rall the varieties except the Milyang 23 , decreased as the cylinder speed increased, but grains with branchlet didnt decrease. The damaged kernels increased with the cylinder speed. 3. The thresher output quality was not affected much by the feed rate. But grains with branchlet and torn heads increased slightly with the feed rate for the head-feeding type thresher since higher resistance lowered at the cylinder speed. 4. In order to reduce grains with branchlet and torn heads in wet-paddy threshing , it is desirable to improve the head-feeding type thresher by developing a new type of cylinder which to not give excess impact on kernels or a concave which has differenct sizes of holes at different locations along the cylinder. 5. For the head-feeding type thresher, there was a difference in separating loss between the varieties. At the cylinder speed of 600 rpm the separating losses for the Minehikari and the Suweon 264 were 1.2% and 0.6% respectively. The separating loss of the head-feeding type thresher was not affected by the moisture content of paddy while that of the Mini-aged thresher increased with the moisture content. 6. From the analysis of the tailings return , to appeared that the tailings return mechanism didn't function properly because lots of single grains and rubbishes were unnecessarily returned. 7. Adding a vibrating sieve to the head-feeding type thresher could increase the efficiency of separation. Consequently , the tailing return mechanism would function properly since unnecessary return could be educed greatly. 8. The power required for the head-feeding type thresher was not affected by the moisture content of paddy, but the average power increased linearly with the feed rate. The power also increased with the cylinder speed.

  • PDF