• Title/Summary/Keyword: Range Accuracy

Search Result 2,670, Processing Time 0.032 seconds

Enhancement of Estimation Method on the Land T-P Pollutant Load in TMDLs Using L-THIA (L-THIA모형을 이용한 수질오염총량관리제 토지계 T-P 발생부하량 산정방식의 개선)

  • Ryu, Jichul;Kim, Eunjung;Han, Mideok;Kim, Young Seok;Kum, Donghyuk;Lim, Kyoung Jae;Park, Bae Kyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.3
    • /
    • pp.162-171
    • /
    • 2014
  • In this study, the uncertainty analysis of present land pollutant load estimation with simplified land category in TMDLs was performed and the enhanced method for land pollutant load estimation with level II land cover consisting of 23 categories was suggested, which was verified by L-THIA model. For land TP load estimation in Jinwi stream basin, the result of comparison between existing method with simplified land category (Scenario 1) and enhanced method with level II land cover (Scenario 2) showed high uncertainty in existing method. TP loads estimated by Scenario 2 for land covers included in the site land category were in the range of 3.45 to 56.69 kg/day, in which TP loads differed by sixteen times as much among them. For application of scenario 2 to TMDLs, Land TP loads were estimated by matching level II land cover to 28 land categories in serial cadastral map (Scenario 3). In order to verify accuracy of TP load estimation by scenario 3, the simulation result of L-THIA was compared with that and the difference between the two was as little as 10%. The result of this study is expected to be used as primary data for accurate estimation of land pollutant load in TMDLs.

Simultaneous Determination of Ultra-Trace Pesticides and Synthetic Materials in Surface Water by LC-ESI-MS/MS (하천수에서 LC-ESI-MS/MS에 의한 극미량 농약류 및 합성원료의 동시분석법)

  • Hong, Seon-Haw;Lee, Jun-Bae;Lee, Soo-Hyung;Cho, Young-Hwan;Shin, Ho-Sang
    • Journal of the Korean Chemical Society
    • /
    • v.59 no.3
    • /
    • pp.225-232
    • /
    • 2015
  • A liquid chromatography-electrospray ionization-tandem mass spectrometry method (LC-ESI-MS/MS) was used for determining seven pesticides (2,4-dichlorophenoxyacetic acid, methomyl, aldicarb, 2-methyl- 4-chlorophenoxy- acetic acid, molinate, carbaryl and carbofuran) and two synthetic materials (quinoline and bisphenol-A) in surface water. The analytes were extracted using solid-phase extraction (SPE). The eluate was concentrated by nitrogen gas. 100 microliters of 30% (v/v) methanol aqueous solution were used to dissolve the residue and an aliquot of the reconstituted solution was directly injected into LC-ESI-MS/MS after the filtration using 0.2 μm polytetrafluoroethylene (PTFE) syringe filter. Under the established condition, the calibration curves of the analytes were linear with correlation coefficients of above 0.997. The quantification limit was 0.002~0.011 μg/L and the relative standard deviations were less than 16.4%. In addition, accuracy was in the range of 84~107% and the recoveries were values between 56.2 and 98.6%. In this study, the developed method was applied to the analysis of real surface water samples.

Determination of Betaine in Fructus Lycii Using Hydrophilic Interaction Liquid Chromatography with Evaporative Light Scattering Detection

  • Shin, Hyun-Du;Suh, Joon-Hyuk;Kim, Jung-Hyun;Lee, Hye-Yeon;Eom, Han-Young;Kim, Un-Yong;Yang, Dong-Hyug;Han, Sang-Beom;Youm, Jeong-Rok
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.553-558
    • /
    • 2012
  • A simple new method was developed for the determination of betaine in Fructus Lycii using hydrophilic interaction liquid chromatography with evaporative light scattering detection (HILIC-ELSD). Good chromatographic separation and reasonable betaine retention was achieved on a Kinetex HILIC column ($2.1{\times}100mm$, $2.6{\mu}m$) packed with fused-core particle. The mobile phase consisted of (A) acetonitrile and (B) 10 mM ammonium formate (pH 3.0)/acetonitrile (90/10, v/v). It was used with gradient elution at a flow rate of 0.7 mL/min. The column temperature was set at $27.5^{\circ}C$ and the injection volume was $10{\mu}L$. The ELSD drift tube temperature was $50^{\circ}C$ and the nebulizing gas (nitrogen) pressure was 3.0 bar. Stachydrine, a zwitterionic compound, was used as an internal standard. Calibration curve over $10-250{\mu}g/mL$ showed good linearity ($R^2$ > 0.9992) and betaine in the 70% methanol extract of Fructus Lycii was well separated from other peaks. Intraand inter-day precision ranged from 1.1 to 3.0% and from 2.4 to 5.3%, respectively, while intra- and inter-day accuracy ranged from 100.0 to 107.0% and from 94.3 to 103.9%, respectively. The limit of quantification (LOQ) was $10{\mu}g/mL$ and the recoveries were in the range of 98.2-102.7%. The developed HILIC-ELSD method was successfully applied to quantitatively determine the amount of betaine in fourteen Fructus Lycii samples from different locations, demonstrating that this method is simple, rapid, and suitable for the quality control of Fructus Lycii.

Development and Characterization of Optical Dissolved Oxygen Sensor based on the Fluorescence Detection (형광검출기반 광학식 용존산소 측정센서 개발 및 특성 분석)

  • Kwak, Hyun Min;Kwon, Myeunghoi;Choi, Gyewoon;Jung, Yoonseok;Jung, Changhwan;Park, Kiuha;Sohn, Okjae;Kim, Junhyong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.569-574
    • /
    • 2014
  • We developed and evaluated a fluorescence-based optical DO sensor (OS-100, Global Optical Communication Ltd., Korea) for long-term monitoring of the dissolved oxygen concentration in waste water treatment. Fluorescent sensing membrane containing $Ru(Dpp)_3{^{2+}}$ (tris(4,7diphenyl-1, 10-phenanthroline) ruthenium(II)) was prepared with GA sol-gel matrix and coated on a quartz plate by sprayed method. Properties of sensor film exhibit deviation about ${\pm}1%$ under wide range of DO concentration from 3 to 10. The developed optical DO sensor was actually mounted in waste water from dyeing industry and successfully applied for on-line DO monitoring. Online monitoring results showed the changes of DO concentrations in wastewater treatment processes with accuracy better than ${\pm}2%$ during the 6 months measurements period in vicious environmental conditions.

Analysis of Pencycuron in Agricultural Products by Simultaneous Determination (동시 다성분 분석법에 의한 농산물 중 펜시쿠론 분석)

  • Park, Young-Hye;Han, Chang-Ho;Kim, Ae-Kyung;Shin, Jae-Min;Lee, Jae-Kyoo;Park, Sun-Hee;Yun, Eun-Sun;Kim, Mu-Sang;Chae, Young-Zoo
    • The Korean Journal of Pesticide Science
    • /
    • v.17 no.3
    • /
    • pp.162-167
    • /
    • 2013
  • An analytical method for the simultaneous determination of pencycuron in agricultural products was established by using GC-NPD. The method was validated through the guidelines of linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy and precision. The calibration curve of pencycuron was linear over the concentration range of 0.02-2 mg/kg with correlation coefficient of above 0.9999. The limits of detection and quantification were 0.005 and 0.02 mg/kg. Mean recoveries of pencycuron for each sample were 79.6-107.5% at the level of 0.02 mg/kg and 86.4-112.1% at the level of 0.2 mg/kg and 84.0- 104.9% at the level of 1 mg/kg. Relative standard deviation (RSD) in recoveries were all less than 5%. The intra- and inter-day precision (RSD) were 1.6-3.0% and 5.3-11.5%, respectively. The result of validation indicated that this method was accurate and sensitive assay.

Temperature Sensitivity Analysis of TDR Moisture Content Sensor for Road Pavement (도로하부 함수비 계측을 위한 TDR 방식 함수비 센서 온도 민감도 분석)

  • Cho, Myunghwan;Lee, Yoonhan;Kim, Nakseok;Jee, Keehwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.1
    • /
    • pp.329-336
    • /
    • 2013
  • The infrastructure of flexible pavement is composed of aggregate subbase, anti-frost layer, and subgrade. In particular, the subgrade performance is affected by climates such as frost action and precipitation. The method of TDR(Time Domain Reflectometry) sensors to measure moisture contents in subgrade layer has been used in the research. Due to the TDR method using dielectric permitivity of soil and water, the sensors can be affected by the low subgrade temperatures. The air temperatures frequently drops below $-20^{\circ}C$ in the winter in Korea. As a result, it is necessary to estimate the accuracy of the TDR moisture sensors in the range of below zero temperatures. In this study, the subgrade temperatures of lower than $-2^{\circ}C$ were extended to evaluate temperature sensitivity of the TDR moisture sensors. The test results revealed that the moisture contents around the sensors were reduced while those of the upper part of specimen showed a tendency to increase as the specimen surface temperature drops below zero under the volumetric moisture contents(VMC) of 20% and 30%. However, the impact of temperature on the function of the sensor at lower water contents was found to be negligible if any.

Simultaneous Characterization of Sofalcone and Its Metabolite in Human Plasma by Liquid Chromatography -Tandem Mass Spectrometry

  • Han, Sang-Beom;Jang, Moon-Sun;Lee, Hee-Joo;Lee, Ye-Rie;Yu, Chong-Woo;Lee, Kyung-Ryul;Kim, Ho-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.5
    • /
    • pp.729-734
    • /
    • 2005
  • A sensitive and selective method for quantitation of sofalcone and its active metabolite in human plasma has been established using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS). Plasma samples were transferred into 96-well plate using an automated sample handling system and spiked with 10 $\mu$L of 2 $\mu$g/mL $d_3$-sofalcone and $d_3$-sofalcone metabolite solutions (internal standard), respectively. After adding 0.5 mL of acetonitrile to the 96-well plate, the plasma samples were then vortexed for 30 sec. After centrifugation, the supernatant was transferred into another 96-well plate and completely evaporated at 40 ${^{\circ}C}$ under a stream of nitrogen. Dry residues were reconstituted with mobile phase and were injected into a $C_{18}$ reversed-phase column. The limit of quantitation of sofalcone and its metabolite was 2 ng/mL, using a sample volume of 0.2 mL for analysis. The reproducibility of the method was evaluated by analyzing 10 replicates over the concentration range of 2 ng/mL to 1000 ng/mL. The validation experiments of the method have shown that the assay has good precision and accuracy. Sofalcone and its metabolite produced a protonated precursor ion ([M+H]$^+$) of m/z 451 and 453, and a corresponding product ion of m/z 315 and 317, respectively. Internal standard ($d_3$-sofalcone and $d_3$-sofalcone metabolite) produced a protonated precursor ion ([M+H]$^+$) of m/z 454 and 456 and a corresponding product ion of m/z 315 and 317, respectively. The method has been successfully applied to a pharmacokinetic study of sofalcone and its active metabolite in human plasma.

Simultaneous Spectrophotometric Determination of Cr(Ⅲ) and Cr(Ⅳ) in Chromium Plating Solution via Flow-Through Analysis (흐름계를 이용한 크롬도금 용액의 Cr(Ⅲ)와 Cr(Ⅵ)의 분광학적 동시 분석 방법)

  • Kim, Sun Kwan;Nam, Hakhyun;So, Jae Chun;Lee, Won;Cha, Geun Sig;Han, Sang Hyun
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.2
    • /
    • pp.87-93
    • /
    • 1995
  • The amount of Cr(Ⅲ) and Cr(Ⅵ) in a chromium plating solution could be determined simultaneously within five minutes using UV/VIS spectrophotometer coupled with a flow-through analysis(FTA) setup. The λmax's at 580 nm and 440 nm which correspond to Cr(Ⅲ) and Cr(Ⅵ), respectively, well obey the Beer-Lambert law in the range over 0.05 g/L for Cr(Ⅲ) and 0.005 g/L for Cr(Ⅵ). when the pH of the sample is less than 4.0, the absorption extinction coefficients of those peaks are not much dependent on the proton concentration. The amount of Cr(Ⅲ) and Cr(Ⅵ), and the total chromium in post treatment chromium plating solution, which normally has few g/L of Cr concentration, could be easily measured using UV/VIS spectrophotometry after the sample had been diluted with sulfuric acid of pH=1.0 in the flow-through analysis setup; this method is far more convenient and faster than the common redox titration (which requires at least 40 min/sample) method, while the accuracy of the method is highly comparable to conventional titrimetric method. Since the implementation of an PTA-UV/VIS setup in any plating industry is cost effective and easy to operate, the analytic method described in this paper may be applied directly for in situ analysis of plating solutions.

  • PDF

Liquid Chromatography Quadrupole Time-Of-Flight Tandem Mass Spectrometry for Selective Determination of Usnic Acid and Application in Pharmacokinetic Study

  • Fang, Minfeng;Wang, Hui;Wu, Yang;Wang, Qilin;Zhao, Xinfeng;Zheng, Xiaohui;Wang, Shixiang;Zhao, Guifang
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.1684-1688
    • /
    • 2013
  • A rapid and sensitive method for determining usnic acid of Lethariella cladonioides in rat was established using high performance liquid chromatography (HPLC) quadrupole time-of-flight (QTOF) tandem mass (MS/MS). Rat plasma was pretreated by mixture of acetonitrile and chloroform to precipitate plasma proteins. Chromatographic separation was achieved on a column ($50{\times}2.1$ mm, $5{\mu}m$) with a mobile phase consisting of water (containing $5{\times}10^{-3}$ M ammonium formate, pH was adjusted to 3.0 with formic acid) and acetonitrile (20:80, v/v) at a flow rate of 0.3 mL/min. A tandem mass spectrometric detection with an electrospray ionization (ESI) interface was conducted via collision induced dissociation (CID) under negative ionization mode. The MS/MS transitions monitored were m/z 343.0448 ${\rightarrow}$ m/z 313.2017 for usnic acid and m/z 153.1024 ${\rightarrow}$ m/z 136.2136 for protocatechuic acid (internal standard). The linear range was calculated to be 2.0-160.0 ng/mL with a detection limit of 3.0 pg/mL. The inter- and intra-day accuracy and precision were within ${\pm}7.0%$. Pharmacokinetic study showed that the apartment of usnic acid in vivo confirmed to be a two compartment open model. The method was fully valid and will probably be an alternative for pharmacokinetic study of usnic acid.

AC-DC Transfer Characteristics of a Bi-Sb Multijunction Thermal Converter (Bi-Sb 다중접합 열전변환기의 교류-직류 변환 특성)

  • 김진섭;이현철;함성호;이종현;이정희;박세일;권성원
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.11
    • /
    • pp.46-54
    • /
    • 1998
  • A planar Bi-Sb multijunction thermal converter, which is consisted of a linear or bifilar thin film NiCr-heater and a thin film Bi-Sb thermopile, has been fabricated, and its ac-dc transfer characteristics were examined in a frequency range from 10 Hz to 10 KHz. In order to increase the thermal sensitivity and to decrease the ac-dc transfer error of a thermal converter, the heater and the hot junctions of a thermopile were prepared on a Si$_3$N$_4$/SiO$_2$/Si$_3$N$_4$-diaphragm which acts as a thermal isolation layer, and the cold junctions on the Si$_3$N$_4$/SiO$_2$/Si$_3$N$_4$-thin film supported with the silicon rim which functions as a heat sink. The respective thermal sensitivities in air and in a vacuum of the converter with a built-in bifilar heater were about 14.0 ㎷/㎽ and 54.0 ㎷/㎽, and the ac-dc voltage and the current transfer difference ranges in air were about $\pm$0.60 ppm and $\pm$0.11 ppm, respectively, indicating that the ac-dc transfer accuracy of the converter are much higher than that of a commercial 3-dimensional multijunction thermal converter. However, the output thermoelectric voltage fluctuation of the converter was rather high.

  • PDF