• Title/Summary/Keyword: Range Accuracy

Search Result 2,679, Processing Time 0.028 seconds

Experiment of proof-of-principle on prompt gamma-positron emission tomography (PG-PET) system for in-vivo dose distribution verification in proton therapy

  • Bo-Wi Cheon ;Hyun Cheol Lee;Sei Hwan You;Hee Seo ;Chul Hee Min ;Hyun Joon Choi
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.2018-2025
    • /
    • 2023
  • In our previous study, we proposed an integrated PG-PET-based imaging method to increase the prediction accuracy for patient dose distributions. The purpose of the present study is to experimentally validate the feasibility of the PG-PET system. Based on the detector geometry optimized in the previous study, we constructed a dual-head PG-PET system consisting of a 16 × 16 GAGG scintillator and KETEK SiPM arrays, BaSO4 reflectors, and an 8 × 8 parallel-hole tungsten collimator. The performance of this system as equipped with a proof of principle, we measured the PG and positron emission (PE) distributions from a 3 × 6 × 10 cm3 PMMA phantom for a 45 MeV proton beam. The measured depth was about 17 mm and the expected depth was 16 mm in the computation simulation under the same conditions as the measurements. In the comparison result, we can find a 1 mm difference between computation simulation and measurement. In this study, our results show the feasibility of the PG-PET system for in-vivo range verification. However, further study should be followed with the consideration of the typical measurement conditions in the clinic application.

Reminder module design to prevent collision accidents while wearing HMD (HMD 착용 중의 충돌 사고 방지를 위한 알리미 모듈 설계)

  • Lee, Min-Hye;Cho, Seung-Pyo;Shin, Seung-Yoon;Lee, Hongro
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.11
    • /
    • pp.1653-1659
    • /
    • 2022
  • Virtual reality content provides users with a high sense of immersion by using HMD devices. However, while wearing the HMD device, it is difficult to determine the user's location or distance from obstacles, resulting in injuries due to physical collisions. In this paper, we propose a reminder module to prevent accidents by notifying the risk of collision with obstacles while wearing the HMD device. The proposed module receives the user's state from the acceleration and gyro sensor and determines the motion that is likely to cause a collision. If there is an obstacle in the expected collision range, a buzzer sounds to the wearer. As a result of the experiment, the accuracy of obstacle detection in the state of wearing the HMD was 86.6% in the 1st stage and 83.3% in the 2nd stage, confirming the performance of the accident prevention reminder.

Evaluation of Proposed Diagnostic System for Detection of Pan-enterovirus Using Reverse Transcription Nested PCR from Water Environment

  • Siwon Lee;Kyung Seon Bae;Jin-Ho Kim;Ji-Hyun Park;Ji Hye Kim;Ji-Yeon Park;Kyung-Jin Lee;Chae-Rin Jeon;Jeong-Ki Yoon;Soo-Hyung Lee;Eung-Roh Park
    • Biomedical Science Letters
    • /
    • v.29 no.2
    • /
    • pp.81-87
    • /
    • 2023
  • Pan-Enterovirus (Pan-EV) infects millions of children and infants worldwide every year. As severe infections have recently been reported, the need for monitoring has consequently intensified. Pan-EV is a categorical name for waterborne enteroviruses belonging to the Picornaviridae family, and includes a wide range of pathogens including Coxsackievirus (CoxV), Echovirus (EcoV) and Enterovirus (EV). In this study, we proposed an optimal RT-nested PCR method for diagnosis of various types of Pan-EV in an aquatic environment and developed a positive control. Considering detection sensitivity, specific reaction, and final identification, one condition capable of amplifying 478 bp among the four candidates in the 1st round PCR (RT-PCR) and one condition in the 2nd round PCR (nested PCR) were selected. Through the detection of nucleic acids extracted from 123 groundwater samples and the detection sensitivity test based on artificial spiking in the sample, the methods are optimal for non-disinfected water samples such as groundwater. We developed a positive control for Pan-EV detection that can be amplified to different sizes under the two conditions. Accuracy could be further improved by testing for contamination from the control group. The method proposed in this study and the positive control developed are expected to be used in monitoring Pan-EV in aquatic environments including groundwater through future research using more samples.

Feasibility Test of Flat-Type Faraday Cup for Ultrahigh-Dose-Rate Transmission Proton Beam Therapy

  • Sang-il Pak;Sungkoo Cho;Seohyeon An;Seonghoon Jeong;Dongho Shin;Youngkyung Lim;Jong Hwi Jeong;Haksoo Kim;Se Byeong Lee
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.108-113
    • /
    • 2022
  • Purpose: Proton therapy has been used for optimal cancer treatment by adapting its Bragg-peak characteristics. Recently, a tissue-sparing effect was introduced in ultrahigh-dose-rate (FLASH) radiation; the high-energy transmission proton beam is considered in proton FLASH therapy. In measuring high-energy/ultrahigh-dose-rate proton beam, Faraday Cup is considered as a dose-rate-independent measurement device, which has been widely studied. In this paper, the feasibility of the simply designed Faraday Cup (Poor Man's Faraday Cup, PMFC) for transmission proton FLASH therapy is investigated. Methods: In general, Faraday cups were used in the measurement of charged particles. The simply designed Faraday Cup and Advanced Markus ion chamber were used for high-energy proton beam measurement in this study. Results: The PMFC shows an acceptable performance, including accuracy in general dosimetric tests. The PMFC has a linear response to the dose and dose rate. The proton fluence was decreased with the increase of depth until the depth was near the proton beam range. Regarding secondary particles backscatter from PMFC, the effect was negligible. Conclusions: In this study, we performed an experiment to investigate the feasibility of PMFC for measuring high-energy proton beams. The PMFC can be used as a beam stopper and secondary monitoring system for transmission proton beam FLASH therapy.

Prediction of residual compressive strength of fly ash based concrete exposed to high temperature using GEP

  • Tran M. Tung;Duc-Hien Le;Olusola E. Babalola
    • Computers and Concrete
    • /
    • v.31 no.2
    • /
    • pp.111-121
    • /
    • 2023
  • The influence of material composition such as aggregate types, addition of supplementary cementitious materials as well as exposed temperature levels have significant impacts on concrete residual mechanical strength properties when exposed to elevated temperature. This study is based on data obtained from literature for fly ash blended concrete produced with natural and recycled concrete aggregates to efficiently develop prediction models for estimating its residual compressive strength after exposure to high temperatures. To achieve this, an extensive database that contains different mix proportions of fly ash blended concrete was gathered from published articles. The specific design variables considered were percentage replacement level of Recycled Concrete Aggregate (RCA) in the mix, fly ash content (FA), Water to Binder Ratio (W/B), and exposed Temperature level. Thereafter, a simplified mathematical equation for the prediction of concrete's residual compressive strength using Gene Expression Programming (GEP) was developed. The relative importance of each variable on the model outputs was also determined through global sensitivity analysis. The GEP model performance was validated using different statistical fitness formulas including R2, MSE, RMSE, RAE, and MAE in which high R2 values above 0.9 are obtained in both the training and validation phase. The low measured errors (e.g., mean square error and mean absolute error are in the range of 0.0160 - 0.0327 and 0.0912 - 0.1281 MPa, respectively) in the developed model also indicate high efficiency and accuracy of the model in predicting the residual compressive strength of fly ash blended concrete exposed to elevated temperatures.

Analysis of residual neomycin in honey by LC-MS/MS (LC-MS/MS에 의한 벌꿀 중 잔류 네오마이신의 분석)

  • Shim, Young-Eun;Jeong, Ji-Yoon;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.319-325
    • /
    • 2009
  • An effective and specific procedure for confirmation of neomycin, aminoglycoside antibiotic in honey was developed and validated. Honey was adjusted to pH 2 with 0.1M HCl and applied to weak cation-exchange SPE cartridge. Neomycin was eluted with basified methanol. Following separation by ion-pairing liquid chromatography, neomycin was analysed with positive electrospray ionization and MRM mode. Quantification was linear over the range of $5.0{\sim}250.0{\mu}g/kg$ ($r^2$ >0.9951). The precision (R.S.D.) and accuracy (as a bias) of quality control samples in honey ranged 11.5~18.7% and 10.9~20.9%, respectively. Established method can be applied to analysis of neomycin in honey.

A Prediction and Distribution of Wetland Based on an E-GIS (E-GIS 기반의 습지분포 및 규모예측)

  • Jang, Yong Gu;Kim, Sang Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.6D
    • /
    • pp.1011-1017
    • /
    • 2006
  • It is so sensitive that the wetland ecosystem very weak in artificial interference and environment change. wetlands are a transitional zone between aquatic and terrestrial ecosystems. This natural property is important to people and life. It is necessary to preservation and protection of the wetland with a countermeasure. we really need to Environment-GIS (E-GIS) and digital map which is included correct position, attribute data and range of the wetland. In this study, we take priority of making a database of wetland management. Moreover, we standardize a digital map production of wetland in our research and we improve accuracy of control survey using GPS surveying. The main purpose of this study is to suggest a pre-estimated wetland that have not yet been discovered. by analysing terrain, geological feature, a geographical distribution of plants and animals using GIS.

Development of an Enhanced 8-node Hybrid/Mixed Plane Stress Element : HQ8-14βElement (8절점 Hybrid/Mixed 평면응력요소)

  • Chun, Kyoung Sik;Park, Won Tae;Yhim, Sung Soon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.2A
    • /
    • pp.319-326
    • /
    • 2006
  • A new enhanced 8-node hybrid/mixed plane stress elements based on assumed stress fields and modifed shape functions has been presented. The assumed stress fields are derived from the non-conforming displacement modes, which are less sensitive to geometric distortion. Explicit expression of shape functions is modifed so that it can represent any quadratic fields in Cartesian coordinates under the same condition as 9-node isoparametric element. The newly developed element has been designated as 'HQ8-$14{\beta}$'. The presented element is compared with existing elements to establish its accuracy and efficiency. Over a wide range of mesh distortions, the element presented here is found to be exceptionally accurate in predicting displacements.

Long Term Flux Variation Analysis on the Boseong Paddy Field (보성 농업지역에서의 장기간 플럭스 특성 분석)

  • Young-Tae Lee;Sung-Eun Hwang;Byeong-Taek Kim;Ki-Hun Kim
    • Atmosphere
    • /
    • v.34 no.1
    • /
    • pp.69-81
    • /
    • 2024
  • In this paper, Annual flux variations in the Boseong Tall Tower (BTT) from 2016 to 2020 were analyzed using data from three levels (2.5 m, 60 m, and 300 m). BTT was installed in Boseong-gun, Jeollanam-do in February 2014 and continued to conduct energy exchange observations such as CO2, sensible heat, and latent heat using the eddy covariance method until March 2023. The BTT was located in a very flat and uniform paddy field, and flux observations were conducted at four levels: 2.5 m, 60 m, 140 m, and 300 m above ground. Surface energy balance was confirmed from observed data of net radiation flux, soil heat flux, sensible heat flux, and latent heat flux. Additionally, 2.5 m height surface fluxes, which are most influenced by agricultural land, were compared with data from Local Data Assimilation and Prediction System (LDAPS) of the Korea Meteorological Administration to evaluate the accuracy of LDAPS flux data. The correlation coefficient between LDAPS flux data and observed values was 0.95 or higher. Excluding summer latent heat flux data, there was a general tendency for LDAPS data to be higher than observed values. The footprint areas estimated below 60 m height mainly covered agricultural land, and flux observations at 2.5 m and 60 m heights showed typical agricultural characteristics. In contrast, the footprint estimated at 300 m height did not show agricultural characteristics, indicating that observations at this height encompassed a wide range, including mountains, sea, and roads. The analysis results of long-term flux observations can contribute to understanding the energy and carbon dioxide fluxes in agricultural fields. Furthermore, these results can be utilized as essential data for validating and improving numerical models related to such fluxes.

Study on Validity of Pre-cooling System for Hydrogen Gas Using Cryocooler Part II: CFD Simulation (극저온 냉동기를 활용한 기체 수소 예냉 시스템 검증에 관한 연구 Part II: CFD 시뮬레이션)

  • YOUNG MIN SEO;HYUN WOO NOH;DONG WOO HA;TAE HYUNG KOO;ROCK KIL KO
    • Journal of Hydrogen and New Energy
    • /
    • v.34 no.5
    • /
    • pp.439-446
    • /
    • 2023
  • In this study, the computational fluid dynamics (CFD) simulations were conducted to verify the cooling capacity of the cryocooler used for pre-cooling of hydrogen gas. Based on the experimental results, the effect of the flow rate on a copper pipe attached to the bottom of the cryocooler was investigated. In this study, the temperature data was calculated through the change of boundary condition for heat flux in the copper pipe. In addition, the cooling capacity of the cryocooler for pre-cooling hydrogen gas was considered by calculating the cooling temperature according to the flow rate in the certified operating range. Consequently the pre-cooing system for hydrogen gas was validated with a reasonable accuracy through CFD simulations.