• Title/Summary/Keyword: Ramp method

Search Result 270, Processing Time 0.035 seconds

Development of a program to predict the airflow rate and pollutant concentration in complex network-type tunnels (네트워크형 터널의 풍량 및 농도해석 프로그램 개발연구)

  • Kim, Hyo-Gyu;Choi, Pan-Gyu;Ryu, Ji-Oh;Lee, Chang-Woo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.2
    • /
    • pp.213-229
    • /
    • 2017
  • Recently, in urban areas there is a tendency to construct more complex network-type tunnels including entrance and exit ramps. At the same time, various one-dimensional programs based on the network theory have been proposed for tunnel ventilation analysis. This paper aims at developing a program that can analyze the ventilation flow rate and pollutants concentration in complex network-type tunnels based on the none hardy-cross method. The flow analysis in the branch was carried out on the basis of the Gradient method, while for the concentration analysis a new logic has been developed to calculate the inflow and outflow concentration automatically in a complex network-type structure. Additionally, in the tunnel segments showing low flow rate, proper grid interval sizes were proposed to reduce numerical error. To verify the applicability of the program, flow rates predicted in the straight tunnels were compared with the classical velocity-diagram method by Stokic and the TVSDM program. The results showed that the errors were within 1%. In addition, the program was applied to the recent ventilation system adopted in the complex network-type urban tunnels.

Determining Ideal Distance between Consecutive Exit Ramps (고속도로 연결로상 연속 분류지점 간의 이격거리 검토)

  • Lee, Seongkwan Mark;Lee, Ki Young;Jang, Jung Hwa
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.1D
    • /
    • pp.65-72
    • /
    • 2011
  • When an expressway intersects another expressway, a unique connector needs to be designed between the two consecutive exit ramps. In such a case, it is important to design a connector such that there is enough distance for drivers to find their way safely. A current design manual in Korea prescribes the minimum length of the connector as 240 m. In this research, we have suggested a method for calculating the minimum length of a connector in order to check the feasibility of the currently prescribed length. For this purpose, we have attempted to determine the total perception-reaction time and lane-changing time required by a driver. For determining the driver's perception-reaction time, we have used the driver's decision time in addition to the conventional 2.5 s of perception-reaction time for stopping sight distances. We have considered both the design speed and the average travel speed for the calculation of the length. To evaluate the accuracy of the new method, we have chosen four sites on expressways for which relatively high accident rates were recorded. As a result, we could verify that the current limit (240 m) was sufficient for drivers to be able to change lanes in the given specific geometry. However, the prescribed limit should be revised in case the drivers' decision time is considered to be their perception-reaction time. All new approaches for calculating the ideal length of a connector have been carried out by taking into account the design speed as well as the average travel speed. Owing to the characteristics of the specific geometry for two consecutive exit ramps and the large difference between the design speed and the average travel speed in the objective areas, it is more realistic to use the proposed method by keeping the decision time equal to a driver's perception-reaction time, in order to determine the ideal distance that should be maintained between two consecutive exit ramps.

Multitoning Method Based on Arrangement of Ink Distribution for Smooth Tone Transition (부드러운 계조 변화를 위한 잉크 분포 조절 기반의 멀티토닝 방법)

  • Park, Tae-Yong;Park, Kee-Hyon;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.4 s.316
    • /
    • pp.17-25
    • /
    • 2007
  • Multilevel inkjet printer employs multiple ink droplets with variable dot size and/or different concentrations intended to preserve high fidelity color reproduction and the appearance of continuous tone. A variety of research efforts on multitoning techniques has progressed toward better image quality. However, banding artifacts appear due to the same dot distributions near the printable output levels. This results in discontinuity and visually unpleasing output, especially at the smooth tone transition region. In this paper, to reduce the banding artifacts, a multitoning method to arrange ink distribution by controlling the blending proportion of adjacent output pixels based on an improved threshold scaling function is proposed. Ink distributions across the banding regions are changed according to two factors of the threshold scaling function because these factors handle the blending point of adjacent output pixel. Therefore, 8 observers, subjectively investigated ink distributions around the printable output levels for a set of the improved threshold scaling function. For a threshold scaling function with the specific factor values, we can achieve smoother visual transition. In the experiment, the proposed method showed a reduction of banding artifacts in both u-ay and color image and represented better Performance of color reproduction.

Acrosomal Changes and Survivability of Following Preservation of Dog Spermatozoa I. The Effects of Different Chilling Duration (개 정자의 보존방법에 따른 첨체 및 생존성의 변화 1. 저온보존에 따른 효과)

  • 정정란;유재규;양성렬;여현진;박종식;예은하;노규진;최상용
    • Journal of Embryo Transfer
    • /
    • v.16 no.1
    • /
    • pp.35-40
    • /
    • 2001
  • Artificial insemination (AI) with frozen or cooled semen is widely used in commercial fields of cattle and pig. Little is known about characteristics of canine sperm after freezing or cooling. For both practical and commercial goal, the canine semen treated with cooling and freezing should be carried out to exam the fundamentals, including sperm motility, survivability and fertilizing capacity. The aim of this study, thus, was to identify the effects of extended exposure to 4$0^{\circ}C$ on canine semen by motility, survivability, acrosomal changes following different duration. Fifteen ejaculates collected by digital manipulation twice per week from 3 dogs (Shih-Tzu) were divided to 16 aliquots after adding Tris-egg yolk (TE) buffer formulated by our laboratory, and cooled from 37 to 4$^{\circ}C$, by ramp rate of 0.6$^{\circ}C$/min. Each sample was evaluated by their motility, survivability and the acrosomal status at 0h (control), 2h, 12h and 1 d~10 d, respectively. The motility of spermatozoa was graded to 6 levels using the modified method of Seager. The survivability of sperm was assessed using an epifluorescence microscope after Fert/Light (Mole-cular Probes Inc.) staining. To estimate the proportion of the spermatozoa of intact acrosome, 200 spermatozoa were assessed in randomly selected fields, using epifluorescence microscope after FITC/PSA (Sigma) staining. At 2 h after cooling, the motility of most spermatozoa were assessed to be grade 0 and 1. At 12 h, high number of sperm were in grade 0 to 1, however, it was significantly (P<0.05) lower than that of 2 h. From 1 d to 4 d, ~50% of sperm was assessed to grade 0 to 1. On day 7, a little sperm were in grade 0 to 1. No sperm showed motility on day 10. Sperm motility was rapidly reduced by the percent of 10% of grade 0 to 1. From 2 h to 6 h, the number of live sperm was 90% and the sperm chilled for 10 days lived>50%. Acrosomal intact of spermatozoa exposed to 4$^{\circ}C$ for 2 h was 51%, supposed the sperm of control was 100%. Our results suggest that 1) this is easy to transfer and preservation for short periods 2) AI can be used by semen chilled for 6-Day.

  • PDF

Development and Evaluation of Rollator for Elderly Farmers

  • Lee, Kyung Suk;Kim, Kyung Ran;Kim, Hyo Cher;Chae, Hye Seon;Kim, Sung Woo;Seo, Min Tae
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.6
    • /
    • pp.487-497
    • /
    • 2014
  • Objective: This study aims to develop and evaluate a multi-purpose rollator, which may be used as a seat, as a traditional walker, or as a storage basket for elderly farmers. Background: The rollators on the market are not user-friendly designed and seen inconvenient for elderly farmers to use, although they are sold at considerably high price. Since they lack enough space to load stuffs and are not durable or stable enough, they do not seem to be suitable for elderly farmers to use in rural areas. Method: Two types of methods were used in this study. First, the survey consisted of 19 questions was conducted among elderly farmers in rural areas, after using the developed rollator, to evaluate the usability of the rollator developed in this study. Second, EMG experiment was conducted to compare the existing rollator and developed rollator quantitatively. Through this experiment, we tried to verify the differences of muscle responses, when using the traditional and the developed ones, which have their own brake system, in the ramp. Results: The developed rollator was highly evaluated in most of the questions in the usability survey, except for the 'Weight' category in which the opinions were divided into three different types (Worse: 31%, Similar: 30%, Better: 36%). The result of EMG experiment showed that the existing rollator (7.4%MVC) demands more muscle strength than the developed rollator (5.5%MVC) does. By statistically analyzing the results of upper limb and lower limb respectively, we found out that all the muscles except deltoid in upper limb showed statistically significant differences in muscle activity when using the existing and the developed rollator. However, there was no statistical difference in lower limb muscles. Conclusion: The developed rollator in this study has maximized the functionality of the brake system, the storage and the chair, which were pointed out as the weaknesses of existing rollators. Furthermore, the developed rollator is designed to be more user-friendly, safe, durable, and effective for elderly farmers to use in rural areas, where roads are rough and bumpy. Application: We expect that the emergency brake system developed in this study would be utilized for other convenience equipment, such as strollers and carts, and that it would be able to develop and produce more secure and reliable equipment in the future.

Effect of Fingertip Temperature on Multi-finger Actions in Young Adults (손 끝 온도변화가 젊은 성인의 다중 손가락 동작에 미치는 효과)

  • Shin, Narae;Xu, Dayuan;Song, Jun Kyung;Park, Jaebum
    • Korean Journal of Applied Biomechanics
    • /
    • v.29 no.3
    • /
    • pp.157-166
    • /
    • 2019
  • Objective: This study examined the effects of stimulating fingertip temperature on the patterns of force sharing and stability properties during multi-finger force production tasks. Method: 9 adult subjects (male: 3, female: 6, age: $26.11{\pm}4.01yrs$, height: $169.22{\pm}5.97cm$, weight: $61.44{\pm}11.27kg$) participated in this study. The experiment consisted of three blocks: 1) maximal voluntary contraction (MVC) task, 2) single-finger ramp task to quantify enslaving (i.e., unintended force production by non-task fingers), and 3) 12 trials of multi-finger steady-state force production task at 20% MVC. There were three temperature conditions including body-temperature (i.e., control condition), $40^{\circ}C$, and $43^{\circ}C$, and the stimulation was given to the index finger only for all experimental conditions. Results: There were no significant differences in the MVC forces, enslaving, and the accuracy of performance during the steady-state task between the conditions. However, the share of stimulated index finger force increased with the index fingertip temperature, while the share of middle finger force decreased. Also, the coefficient of variation of both index and middle finger forces over repetitive trials increased with the index fingertip temperature. Under the framework of the uncontrolled manifold (UCM) hypothesis used to quantify indices of multi-finger synergies (i.e., stability property) stabilizing total force during the steady-state task, the two variance components within the UCM analysis increased together with the fingertip temperature, while no changes in the synergy indices between the conditions. Conclusion: The current results showed that fingertip temperature stimulation only to index finger does not affect to muscle force production capability of multi-finger, independence of individual fingers, and force production accuracy by the involvement of all four fingers. The effect of fingertip temperature on the sharing pattern and force variation may be due to diffuse reflex effects of the induced afferent activity on alpha-motoneuronal pools. However, the unchanged stability properties may be the reflection of the active error compensation strategies by non-stimulated finger actions.

A Study on the Characteristics of Museum Projects by Richard Meier (리챠드 마이어의 미술관 특성에 관한 연구)

  • 김용립
    • Archives of design research
    • /
    • v.12 no.4
    • /
    • pp.231-241
    • /
    • 1999
  • This study propose to analyze the design method and the form elements of museums, of works by Richard Meier, and through the analysis, spacial characteristics of museums will be understood. The museum works of Richard Meier, as an exhibition space, not only display the art works efficiently, but they also offer visitors the opportunity to experience the art of architecture, as a cultural space. Richard Meier, when working on the projects, has utilized the design methods and the architectural language, learned from Mies van der Rohe and Le Corbusier, resourcefully. Having the structural grid as basis, the rational rectangular forms were intended for exhibition space, while the circular and partial circular forms of geometry were utilized in formative space. This was able to maintain the balance between functional and formative space. In the museums of his works, the ramp and the glass wall separated from the structure become very important means of expression. The ramps, not only make people to enjoy the interior and exterior of museum, but also able them to see the works of art from different distances and angles repeatedly and the large glass wall reveals the various shapes of interior to exterior. In comparing with the design method and language of two masters mentioned, the design principles and elements, developed by Meier were applied to the site plans, exhibition space planning and elevations to manifest its originality. The design concept, derived from the urban fabric and historical buildings around, gave harmony to the museum with its surroundings, and employing the deformed axis brought variation and the effect of diversion to the site plan. The exhibition space is much vitalized by the well arrangement of various exhibition fixtures in the museum. The exhibion fixtures, which the partitions, shelves, miches, and stages were put together in flexibility, play multiple roles as partitions dividing spaces, as furniture displaying art works, and as elements creating forms. The systematically arranged fixtures, also produce several visual axes and centers, which have visitors appreciate the works of art in various perspectives, hence create a unique environment.

  • PDF

A Study on the Establishment of Optimal Transportation Networks in Busan New Port (부산항 신항 최적의 교통망 수립에 관한 연구)

  • Park, Ho-Kyo;Choi, Yang-Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.125-132
    • /
    • 2017
  • The development project of Busan New Port aims to be Logistics Hub Port but there are too many things to deal with ; enlargement of harbour, interport competition, modernization of harbour loading equipment and so on. At present, 23 berths of North and South container quay are in operation and 22 berths will be constructed on west and south-side by 2020. Namely, Busan New Port will operate 45 berths in 2020. When it comes to port distripark, a large-scale of Port distripark project is underway, such as Ung-Dong district 1,2 phase, West container 1,2phase, North distripark and so on. This study is to deduce traffic system problem of Busan New Port which is caused by the development project through predicting traffic need considering the development project. According to study, there are three main problems of traffic system : 1. traffic congestion caused on main crossroad, connecting second harbour back road. 2. It has been predicted that South-North road and traffic capacity of New Port road would lack compared to traffic volume-to-be-increased. Moreover, the detour volume of traffic is caused because New Port's 1st avenue and route 2 were not connected directly. Thus, this study suggests three kinds of improvement plan for smoother traffic flow. 1st. Operate roundabout on major intersection, for example, second harbour back road, west container wharf's subway corridors(South to North), and permit only right turn on sub-intersection. 2nd. Extend New Port road(North container's port road) by utilizing side walk and median. 3rd. Install exit ramp which utilizes Route 2 connecting New Port's 1st avenue and local road 1042. The method we used to analyze the effect of improvement is Vissim of Mircro Simulation Package.

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.