• Title/Summary/Keyword: Raman spectrometer

Search Result 76, Processing Time 0.02 seconds

Development of an Ultraviolet Raman Spectrometer for Standoff Detection of Chemicals

  • Ha, Yeon Chul;Lee, Jae Hwan;Koh, Young Jin;Lee, Seo Kyung;Kim, Yun Ki
    • Current Optics and Photonics
    • /
    • v.1 no.3
    • /
    • pp.247-251
    • /
    • 2017
  • In this study, an ultraviolet Raman spectrometer was designed and fabricated to detect chemical contamination on the ground. The region of the Raman spectrum that indicated the characteristics of the chemicals was $350-3800cm^{-1}$. To fabricate a Raman spectrometer operating in this range, the layout and angle of optical components of the spectrometer were designed using a grating equation. Experimental devices were configured to measure the Raman spectra of chemicals based on the fabricated Raman spectrometer. The wavenumber of the spectrometer was calibrated by measuring the Raman spectrum of polytetrafluoroethylene, $O_2$, and $N_2$. The spectral range of the spectrometer was measured to be 23.46 nm ($3442cm^{-1}$) with a resolution of 0.195 nm ($30.3cm^{-1}$) at 253.65 nm. After calibration, the main Raman peaks of cyclohexane, methanol, and acetonitrile were found to be similar to the references within a relative error of 0.55%.

Polarized Raman Spectroscopic Studies of Syndiotactic Polypropylene (편광 Raman 분광법을 이용한 Syndiotactic Polypropylene에 관한 연구)

  • 진정희;임현주;김성수;송기국
    • Polymer(Korea)
    • /
    • v.26 no.6
    • /
    • pp.745-751
    • /
    • 2002
  • The anisotropic Raman scattering properties of oriented syndiotactic poly propylene have been investigated using FT-Raman spectrometer in which the fluore scent problem of polymer samples can be removed. To assign the observed Raman bands to their respective symmetry species, the anisotropic scattering results for four different combinations of incident and scattered polarization were compared with those predicted by normal coordinate analysis and infrared dichroism measurement data.

Study on Mobile Broadband Coherent Anti-Stokes Raman Spectrometer For Combustion Diagnostics (연소진단용 이동형 광대역 코헤런트 반 스톡스 라만 분광기에 관한 연구)

  • Park, Chul-Woung;Park, Seung-Nam;Hahn, Jae-Won;Lee, Jong-Ung
    • Journal of the Korean Society of Combustion
    • /
    • v.1 no.2
    • /
    • pp.9-20
    • /
    • 1996
  • We construct a mobile broadband coherent anti-Stokes Raman spectroscopy system to measure the temperature of combustion gases. To improve the accuracy of CARS temperatures due to Stokes lasers, a modeless dye laser is constructed. A monochromator to disperse CARS spectra is also constructed in the spectrometer for easy portability. The accuracy of CARS temperature, measured in graphite tube furnace in reference to a radiation pyrometer, is better than 2 % from 1000 K to 2400 K. The CARS temperature error due to the variation of the spectral distribution of the modeless laser is measured to be less than 1.5 % during five hours operation. As a demonstration of combustion diagnosis, we applied the spectrometer to measure the temperature distribution of the propane air premixed flame.

  • PDF

Wide Field Imaging Analysis of Graphene (그래핀의 대면적 이미지 특성 분석)

  • Kwon, Kanghyuk;Kim, Nayoung;Havener, Robin W.;Won, Donggwan;Cho, Seungmin;Park, Jiwoong
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.3
    • /
    • pp.143-147
    • /
    • 2013
  • A Raman spectrometer is essential for analyzing the characteristics of graphene. The commercial micro-Raman spectrometer is useful for measuring small areas, but due to the small measuring area, it has limited use in industry, as a sampling measure. This paper suggests a Raman spectrometer able to get a large area image of graphene. By using this image, we can get information on defects and on the presence of graphene. Therefore, this equipment can be used for quality assessment for production of graphene.

The Design and Test of the Stand-off Surface Chemical Contaminant Detection System based on Raman Spectroscopy (비접촉식 지표면 화학 오염 탐지용 라만 분광시스템 설계 및 성능확인)

  • Koh, Young Jin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.433-440
    • /
    • 2019
  • In order to detect toxic chemical spread on field ground, we developed stand-off Raman spectrometer system which employed a deep UV laser. In this paper, the design and specification of various components in the spectrometer system are described. Some results when the detection system was tested on the outdoor roads are shown, which may help researching stand-off chemical detectors based on Raman spectroscopy.

Measurement of CO Q-branch Raman Spectrum by using High Resolution Inverse Raman Spectrometer (고분해능 Inverse 라만 분광기를 이용한 CO Q-branch 라만 분광 측정)

  • 한재원
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1989.02a
    • /
    • pp.59-64
    • /
    • 1989
  • Raman vibrational Q0branch spectra of pure CO are measured by using the technique of quasicw inverse Raman spectroscopy utilizing a pulsed single-frequency laser source. This approach gives enhanced sensitivity compared to earlier work which employed CW lasers, allowing extension of that work to higher accuracy, higher J states, and higher pressure. Fitting laws with pertubation theory and modified energy gap(MEG) theory are described, and the line broadening and shifting coefficients of J=0 to 24 are determined with both fitting laws.

  • PDF

Composition and Temperature Dependence of Structural Changes in Borosilicate Glasses by Spectrometer (분광계에 의한 Borosilicate계 글라스의 조성 및 온도의존성 평가)

  • Park Sung-Je;Ryu Bong-Ki
    • Korean Journal of Materials Research
    • /
    • v.15 no.12
    • /
    • pp.786-790
    • /
    • 2005
  • We investigated the particularity of temperature and composition changes in $xNa_2O{\cdot}(52.5-x)B_2O_3{\cdot}47.5SiO_2$ glasses by use of FT-IR, $^{11}B$ NMR, Raman spectrometer. From FT-IR and $^{11}B$ NMR spectrometer, we thought that tetrahedral boron, $BO_4$ units are created $N_4$ increasing tendency generated near $600^{\circ}C$. It's expected that composition ana heat treatment directly contributed to structural changes, this changes are following to $Na_2O$ increasing or decreasing. caused by $N_4\;and\;BO_4$ units are caused by relatively increasing or decreasing in the glasses' structure. Particularly, $BO_4$ units are converted to $BO_3$ units after $600^{\circ}C$ heat treatment for 50h in the composition of $x<18(R<0.5,\;R=Na_2O/B_2O_3\;mol\%)$. On the order hand, $BO_3$ units are converted to, $BO_4$ units after $600^{\circ}C$ heat treatment for 50h in the composition of $x{\geq}18\;(R>0.5)$. This particularity of composition and temperature dependence of structural changes are similarly represented by Raman analysis results.

The Color Enhancement of Brown Tinted Diamonds with Annealing Temperatures in 5.6 Gpa-10 min HPHT (천연 갈색다이아몬드의 5.6 Gpa-10분 조건에서 처리온도에 따른 색 변화 연구)

  • Li, Feng;Song, Oh-Sung
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.1
    • /
    • pp.23-27
    • /
    • 2012
  • The color of a natural diamond that contains nitrogen impurities can be enhanced by a high pressure high temperature (HPHT) treatment. Type IaAB diamond samples containing nitrogen impurities were executed by HPHT process of 5.6 Gpa, 10 min by varying the annealing temperature at 1600, 1650, and $1700^{\circ}C$. Property characterization was carried out using an optical microscope, FT-IR spectrometer, low-temperature PL spectrometer, and micro Raman spectrometer. By observing optical micrographs, it can be seen that diamond sample began to alter its color to vivid yellow at $1700^{\circ}C$. In the FT-IR spectrum, there were no Type changes of the diamond samples. However, amber centers leading to brown colors lessened after $1700^{\circ}C$ annealing. In the PL spectrum, all the H4 centers became extinct, while there were no changes of yellow color center H3 before or after treatment. In the Raman spectrum, no graphite spots were detected. Consequently, diamond color enhancement can be done by higher than $1700^{\circ}C$ HPHT annealing at 5.6 GPa-10 min.

Analysis of Hyperspectral Dentin Data Using Independent Component Analysis

  • Jung, Sung-Hwan
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.12
    • /
    • pp.1755-1760
    • /
    • 2009
  • In this research, for the first time, we tried to analyse Raman hyperspectral dentin data using Independent Component Analysis (ICA) to see its possibility of adoption for the dental analysis software. We captured hyperspectral dentin data on 569 spots on a molar with dental lesion by HR800 Micro Raman Spectrometer at UMKC-CRISP (University of Missouri at Kansas City-Center for Research on Interfacial Structure and Properties). Each spot has 1,005 hyperspectral data. We applied ICA to the captured hyperspectral data of dentin for evaluating ICA approach, and compared it with the well known multivariate analysis method, PCA. As a result of the experiment, ICA approach shows better local characteristic of dentin than the result of PCA. We confirmed that ICA also could be a good method along with PCA in the dental analysis software.

  • PDF

Composition and structure analysis of natural gas hydrates

  • 박영준;김도연;박제성;이흔
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.660-662
    • /
    • 2005
  • 본 연구에서는 미 인근 해저에서 ODP로 확인된 부존 하이드레이트 샘플을 다양한 분광학 및 실험적 분석 방법을 통해 시료의 물성 및 특성을 파악하여 부존된 하이드레이트 자원의 성분 파악을 목적으로 하고 있다. 일반적으로 가스 하이드레이트 연구에 있어서 X-ray diffractometer, NMR stectrometer, Raman spectrometer 등 분광학적 분석기기를 이용하여 가스 하이드레이트의 구조 및 성분을 규명한다. 본 연구에서는 실험실에서 인위적으로 만들어진 메탄 하이드레이트와 심해저 천연가스 하이드레이트 층에서 채취된 샘플의 비교 분석을 통하여 심해에 매장되어 있는 천연가스 하이드레이트의 구조 및 성분을 규명하였다 XRD 결과로부터 천연가스 하이드레이트는 sI의 구조를 가지며 NMR 및 Raman 결과에 의하면 하이드레이트 내에 포집되어 있는 가스의 주 성분은 메탄인 것으로 밝혀졌다. 또한 천연가스 하이드레이트를 이용한 이산화탄소의 치환 실험을 통하여 심해저 천연가스 하이드레이트 층의 이산화탄소 저장 매체로의 활용 가능성을 조사하였다.

  • PDF