• 제목/요약/키워드: Raman Analysis

검색결과 467건 처리시간 0.024초

Raman Chemical Imaging Technology for Food and Agricultural Applications

  • Qin, Jianwei;Kim, Moon S.;Chao, Kuanglin;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • 제42권3호
    • /
    • pp.170-189
    • /
    • 2017
  • Purpose: This paper presents Raman chemical imaging technology for inspecting food and agricultural products. Methods The paper puts emphasis on introducing and demonstrating Raman imaging techniques for practical uses in food analysis. Results & Conclusions: The main topics include Raman scattering principles, Raman spectroscopy measurement techniques (e.g., backscattering Raman spectroscopy, transmission Raman spectroscopy, and spatially offset Raman spectroscopy), Raman image acquisition methods (i.e., point-scan, line-scan, and area-scan methods), Raman imaging instruments (e.g., excitation sources, wavelength separation devices, detectors, imaging systems, and calibration methods), and Raman image processing and analysis techniques (e.g., fluorescence correction, mixture analysis, target identification, spatial mapping, and quantitative analysis). Raman chemical imaging applications for food safety and quality evaluation are also reviewed.

라만 분광법을 이용한 반도체 공정 중 표면 분석 (Surface analysis using Raman spectroscopy during semiconductor processing)

  • 최태민;유진욱;정은수;이채연;이화림;김동현;표성규
    • 한국표면공학회지
    • /
    • 제57권2호
    • /
    • pp.71-85
    • /
    • 2024
  • This article provides an overview of Raman spectroscopy and its practical applications for surface analysis of semiconductor processes including real-time monitoring. Raman spectroscopy is a technique that uses the inelastic scattering of light to provide information on molecular structure and vibrations. Since its inception in 1928, Raman spectroscopy has undergone continuous development, and with the advent of SERS(Surface Enhanced Raman Spectroscopy), TERS(Tip Enhanced Raman Spectroscopy), and confocal Raman spectroscopy, it has proven to be highly advantageous in nano-scale analysis due to its high resolution, high sensitivity, and non-destructive nature. In the field of semiconductor processing, Raman spectroscopy is particularly useful for substrate stress and interface characterization, quality analysis of thin films, elucidation of etching process mechanisms, and detection of residues.

Analysis of Temperature Effects on Raman Silicon Photonic Devices

  • Kim, Won-Chul;Park, Dong-Wook
    • Journal of the Optical Society of Korea
    • /
    • 제12권4호
    • /
    • pp.288-297
    • /
    • 2008
  • Recent research efforts on study of silicon photonics utilizing stimulated Raman scattering have largely overlooked temperature effects. In this paper, we incorporated the temperature dependences into the key parameters governing wave propagation in silicon waveguides with Raman gain and investigated how the temperature affects the solution of the coupled-mode equations. We then carried out, as one particular application example, a numerical analysis of the performance of wavelength converters based on stimulated Raman scattering at temperatures ranging from 298 K to 500 K. The analysis predicted, among other things, that the wavelength conversion efficiency could decrease by as much as 12 dB at 500 K in comparison to that at the room temperature. These results indicate that it is necessary to take a careful account of temperature effects in designing, fabricating, and operating Raman silicon photonic devices.

편광 Raman 분광법을 이용한 Syndiotactic Polypropylene에 관한 연구 (Polarized Raman Spectroscopic Studies of Syndiotactic Polypropylene)

  • 진정희;임현주;김성수;송기국
    • 폴리머
    • /
    • 제26권6호
    • /
    • pp.745-751
    • /
    • 2002
  • 본 연구에서는 시료의 형광문제를 제거한 FT-Raman spectrometer을 이용하여 연신된 syndiotactic polypropylene의 비등방적 Raman 산란 특성을 측정하였다. 관찰된 Raman 피크를 해석하여 해당 symmetry species 분류를 목적으로, 입사 및 산란 복사선의 편광방향이 서로 다른 4 가지 편광실험을 수행하여 스펙트럼을 얻었다. 이 편광 Raman 실험 결과를 편광 infrared 실험에 의한 dichroism 결과 및 진동운동의 이론적 계산인 normal coordinate analysis 결과와 비교 분석하였다.

Comparison of Near-Infrared Spectroscopy with Raman Spectroscopy from the Point of Nondestructive Analysis of Biological Materials

  • Takeyuki Tanaka;Hidetoshi Sato;Jung, Young-Mee;Yukihiro Ozaki
    • Near Infrared Analysis
    • /
    • 제1권2호
    • /
    • pp.9-20
    • /
    • 2000
  • Recently, near-infrared (NIR) spectroscopy and Raman spectroscopy have received keen interest as powerful techniques for nondestructive analysis of biological materials. The purpose of this review paper is to compare the advantages of NIR and Raman spectroscopy in the nondestructive analysis. Both methods are quite unique and often complementary. For example. NIR spectroscopy is very useful in monitoring in situ the content of components inside biological materials while Raman spectroscopy is very suitable for identifying micro-components on the surface of biological materials. In this article specific characters of the two spectroscopic methods are discussed first and then several examples of applications of NIR and Raman spectroscopy to the biological nondestructive analysis are introduced.

Structural Study of the Activated Carbon Fiber using Laser Raman Spectroscopy

  • Roh, Jae-Seung
    • Carbon letters
    • /
    • 제9권2호
    • /
    • pp.127-130
    • /
    • 2008
  • This study aims to find a correlation between XRD and Raman result of the activated carbon fibers as a function of its activation degrees. La of the isotropic carbon fiber prepared by oxidation in carbon dioxide gas have been observed using laser Raman spectroscopy. The basic structural parameters of the fibers were evaluated by XRD as well, and compared with Raman result. The La of the carbon fibers were measured to be 25.5 ${\AA}$ from Raman analysis and 23.6 ${\AA}$ from XRD analysis. La of the ACFs were 23.6 ${\AA}$ and 20.4 ${\AA}$, respectively, representing less ordered through activation process. It seems that the $I_D/I_G$ of Raman spectra were related to crystallite size(La). Raman spectroscopy has demonstrated its unique ability to detect structural changes during the activation of the fibers. There was good correlation between the La value obtained from Raman and XRD.

철제유물 부식화합물 분석의 표준데이터 확보를 위한 라만 분광법 적용성 연구 (Application Study of Raman Micro-Spectroscopy for Analysis on Corrosion Compound of Iron Artifacts)

  • 박형호;이재성;유재은
    • 보존과학연구
    • /
    • 통권32호
    • /
    • pp.89-98
    • /
    • 2011
  • 철 부식화합물은 부식인자들과 함께 다양한 결정구조를 가지며 2가지 이상의 부식화합물들이 혼합되어 존재하므로 각각의 특성을 밝혀내기가 매우 어렵다. 본 연구는 표준 철 부식물을 대상으로 Raman Micro-Spectroscopy 분석을 실시하여 표준 Raman Data 확보를 목적으로 수행하였다. 표준 철 부식물에 대한 신뢰성을 향상시키기 위하여 SEM-EDS 분석과 XRD 분석을 추가로 실시하였다. SEM-EDS 분석결과 모두 표준 철 부식물의 구성성분과 일치하였으나 Goethite의 경우 철 이외의 비철금속 성분이 검출되었다. XRD 분석 결과 모두 표준 철 부식물의 구조와 일치 하였으나 Iron sulfate($FeSO_4{\cdot}6H_2O$)의 경우 Rozenite($FeSO_4{\cdot}4H_2O$)로 확인되었다. Raman Micro-Spectroscopy 분석결과 기존에 연구되었던 수산화철, 산화철의 Wavenumber에서 새로운 peak이 발견되었는데 이는 레이저 파장의 변화에 따른 것으로 사료 된다. 염화철과 황산철에서 Wavenumber가 새롭게 확인되어 표준 Raman Data 8건을 확보하였다. Raman Micro-Spectroscopy는 적은양의 시료를 이용하여 물질의 특성과 구조를 비교적 간단하게 분석 할 수 있어 미세한 부분이나 시료의 양이 한정된 문화재에 활용도가 높을 것으로 판단된다.

  • PDF

Structural Study of the Oxidized High Modulus Carbon Fiber using Laser Raman Spectroscopy

  • Roh, Jae-Seung;Kim, Suk-Hwan
    • Carbon letters
    • /
    • 제10권1호
    • /
    • pp.38-42
    • /
    • 2009
  • This study aims to find a correlation between XRD and Raman result of the oxidized high modulus carbon fibers as a function of its oxidation degrees, and compare with the isotropic carbon fiber reported early. La of the high modulus carbon fiber prepared by oxidation in carbon dioxide gas have been observed using laser Raman spectroscopy. The basic structural parameters of the fibers were evaluated by XRD as well. The La of the original high modulus carbon fibers were measured to be 144 ${\AA}$ from Raman analysis and 135 ${\AA}$ from XRD analysis. La of the 92% oxidized fiber were 168 ${\AA}$ by using Raman and 182 ${\AA}$ by using XRD. There was some correlation between the La value obtained from Raman and XRD. However the La value changes of the high modulus carbon fiber through whole oxidation process showed opposite tendency compare with the isotropic carbon fiber because of the fiber structure basically.

마이크로 라만 및 XPS를 이용한 CIGS 박막의 두께방향 상분석 비교 (Comparison of Depth Profiles of CIGS Thin Film by Micro-Raman and XPS)

  • 백근열;전찬욱
    • Current Photovoltaic Research
    • /
    • 제4권1호
    • /
    • pp.21-24
    • /
    • 2016
  • Chalcopyrite based (CIGS) thin films have considered to be a promising candidates for industrial applications. The growth of quality CIGS thin films without secondary phases is very important for further efficiency improvements. But, the identification of complex secondary phases present in the entire film is crucial issue due to the lack of powerful characterization tools. Even though X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) and normal Raman spectroscopy provide the information about the secondary phases, they provide insufficient information because of their resolution problem and complexity in analyzation. Among the above tools, a normal Raman spectroscopy is better for analysis of secondary phases. However, Raman signal provide the information in 300 nm depth of film even the thickness of film is > $1{\mu}m$. For this reason, the information from Raman spectroscopy can't represent the properties of whole film. In this regard, the authors introduce a new way for identification of secondary phases in CIGS film using depth Raman analysis. The CIGS thin films were prepared using DC-sputtering followed by selenization process in 10 min time under $1{\times}10^{-3}torr$ pressure. As-prepared films were polished using a dimple grinder which expanded the $2{\mu}m$ thick films into about 1mm that is more than enough to resolve the depth distribution. Raman analysis indicated that the CIGS film showed different secondary phases such as, $CuIn_3Se_5$, $CuInSe_2$, InSe and CuSe, presented in different depths of the film whereas XPS gave complex information about the phases. Therefore, the present work emphasized that the Raman depth profile tool is more efficient for identification of secondary phases in CIGS thin film.

Raman Detection of Protein Interfacial Conformations

  • Jang, Mi-Jin;Cho, Il-Young;Callahan, Patricia
    • BMB Reports
    • /
    • 제30권5호
    • /
    • pp.352-355
    • /
    • 1997
  • The surface adsorbed protein conformations onto the vaccine adjuvants were observed with a Raman spectroscopy by using the maximum adsorption conditions described previously. The adsorbed state Raman vibrational spectra and subsequent spectral analysis display no conformational changes for BSA or IgG relative to their native species in solution.

  • PDF