• Title/Summary/Keyword: Railroad feeding system

Search Result 71, Processing Time 0.024 seconds

Harmonics Assessment for an Electric Railroad Feeding System using Moments Matching Method (모멘트 정합 방법(Moment Matching Method)을 이용한 전기철도 급전시스템의 고조파 평가)

  • Lee, Jun-Kyong;Lee, Seung-Hyuk;Kim, Jin-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.1-7
    • /
    • 2007
  • Generally, an electric railroad feeding system has many problems due to the different characteristics in contrast with a load of general three-phase AC electric power system. One of them is harmonics problem caused by the switching device existing in the feeding system, and moreover, the time-varying dynamic loads of rail way is inherently another cause to increase this harmonics problem. In Korea power systems, the electric railroad feeding system is directly supplied from the substation of KEPCO. Therefore, if voltages fluctuation or unbalanced voltages are created by the voltage and current distortion or voltage drop during operation, it affects directly the source of supply. The trainloads of electric railway system have non-periodic but iterative harmonic characteristics as operating condition, because the electric characteristic of the electric railroad feeding system is changed by physical conditions of the each trainload. According to the traditional study, the estimation of harmonics has been performed by deterministic way using the steady state data at the specific time. This method is easy to analyze harmonics, but it has limits in some cases which needs an assessment of dynamic load and reliability. Therefore, this paper proposes the probabilistic estimation method, moments matching method(MW) in order to overcome the drawback of deterministic method. In this paper, distributions for each harmonics are convolved to obtain the moments and cumulants of TDD(Total Demand Distortion), and this can be generalized for any number of trains. For the case study, the electric railway system of LAT(Intra Airport Transit) in Incheon International Airport is modeled using PSCAD/EMTDC dynamic simulator. The raw data of harmonics for the moments matching method is acquired from simulation of the LAT model.

Performance Comparison of the Railway Traction IPM Motors between Concentrated Winding and Distributed Winding

  • Park, Chan-Bae;Lee, Byung-Song;Lee, Hyung-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.118-123
    • /
    • 2013
  • This paper presents performance comparison between concentrated winding and distributed winding of IPMSM (Interior Permanent Magnet Synchronous Motors) which is recently used for light-weight railway applications. Motors are designed on various schemes and analyzed by using FEM (Finite Element Method) instead of EMCNM (Equivalent Magnetic Circuit Network Method) in order to take into account saturation and non-linear magnetic property. The overall performance such as torque, torque ripple, losses, demagnetization, efficiency, power density and so on are investigated in detail at the rated and maximum operating speed. The results of the analysis found that both concentrated and distributed winding IPMSMs are promising candidates for high power railway traction motor.

Practical diagnostic technique for catenary surge arrester in electric railway (전차선로용 피뢰기 진단기법 적용 연구)

  • Han, Moon-Seob;Jang, Dong-Uk;Jung, Ho-Sung;Kil, Gyung-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1631-1633
    • /
    • 2005
  • This paper describes the measurement result of leakage current flowing arrestors connected in catenary line to propose an optimal management methods. 27 arrestors set in 7 locations were tested. The leakage currents are included a harmonics of electric train during the operation of electric train in feeding section and in case of feeding earthing system.

  • PDF

Investigation of harmonic evaluating factor in electric railroad (전기철도에서의 고조파 평가지수 검토)

  • Lee, Chang-Mu;Han, Moon-Seub;Ahn, Young-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1251-1253
    • /
    • 2002
  • Most of the substations, which had been constructed so far, only took into account the current distortion as an evaluation factor for harmonics. There is, however, growing tendency for the currently constructed substations to construct transmission lines in an underground way. Therefore, the overhaul investigation on the psophometric current is all the more necessary. In this study, the harmonic current, the current distortion and the psophometric current, which flow into the substation in accordance with a feeding system and the number of trains in operation are investigated and compared based on the six-port analysis method of feeding system, which has been proposed.

  • PDF

A Study on the Design of the Flywheel Energy Storage Device to Store the Regenerative Energy (회생에너지 저장용 플라이휠 에너지 저장 장치 설계에 관한 연구)

  • Lee, Jun-Ho;Park, Chan-Bae;Lee, Byeong-Song
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.1045-1052
    • /
    • 2013
  • In this study we deal with design procedures for the flywheel energy storage system that has the capacity to store the regenerative energy produced from the railway vehicles. The flywheel energy storage system (FESS) stores the regenerative electrical energy into the high speed rotational flywheel, by conversion the electrical energy into the mechanical rotational energy. Thus the FESS is composed of the energy conversion components, such as the motor and generator, mechanical support components, such as the rotational rotor, the magnetic bearings to support the rotor, and the digital controller to control the air gap between the rotor and the magnetic bearings. In this paper the design procedures for the rotor operating at the rigid mode and the magnetic bearings to support the rotational rotor without contact are presented.

Parametric Study for Variable Tap of Autotransformer Neutral in AC Feeding (전기철도 단권변압기 중성점 탭절환 특성연구)

  • Han, Moonseob;Lee, Chang-Mu;Kim, Jae-Won;Chang, Sang-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.137-141
    • /
    • 2018
  • The voltage drop is important in electric railway for feeding a huge power of train on fixed feeding area. Nowadays it is tried to operate a high speed trains on conventional lines and there is problem on the voltage drop too. It is simulated on the conditions increased the turn ratio of trolley, installed autotransformer neutral line with variable taps. In result, it is compensated the voltage drop between ATs and better on last AT, not on the position of AT. And it is decreased a return current and neutral current of AT because of unbalance between trolley and feeder. It should be studied faster and more controllable the solid state switchs instead of the mechanical one in order to utilize this system.

Compensation of Instantaneous Voltage Drop at AC Railroad System with Single-Phase Distributed STATCOM (전기철도 급전시스템의 순시전압강하 보상을 위한 단상 배전 STATCOM의 적용)

  • Kim, Jun-Sang;Lee, Seung-Hyuk;Kim, Jin-O;Lee, Jun-Kyung;Jung, Hyun-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.42-51
    • /
    • 2007
  • An AC electrical railroad system has rapidly changing dynamic single-phase load, and at a feeding substation, three-phase electric power is transformed to the paired directional single-phase electric power. There is a great difference in electrical phenomenon between the load of AC electrical railroad system and that of general power system. Electric characteristics of AC electrical railroad's trainload are changed continuously according to the traction, operating characteristic, operating schedule, track slope, etc. Because of the long feeding distance of the dynamic trainload, power quality problems such as voltage drop, voltage imbalance and harmonic distortion my also occur to AC electrical railroad system. These problems affect not only power system stability, but also power quality deterioration in AC electrical railroad system. The dynamic simulation model of AC electrical railroad system presented by PSCAD/EMTDC is modeled in this paper, andthen, it is analyzed voltage drop for AC electrical railroad system both with single-phase distributed STATCOM(Static Synchronous Compensator) installed at SP(Sectioning Post) and without.

Consideration of Conductance between Rails and Ground in DC Railway (직류전기철도 레일-대지간 절연저항 측정 방안)

  • Han, Moon-Seob;Kim, Ju-Rak;Jung, Ho-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.166-168
    • /
    • 2008
  • DC feeding system is mainly floating but the rail potential and the leakage current are created because of long parallelism between rails and ground. Rail potential causes electric shock to human and leakage current causes electrolytic corrosion to nearby the buried metals. Therefore the design technologies to reduce, protect and monitor these effects are important recent DC feeding system. Rail potential and leakage current are analysed based on propagation theory that is utilized in order to simulate grounding system. New measurement procedure is proposed based on this analysis in order to more be accurate in result.

  • PDF

Probabilistic Method for The Harmonic Analysis of Railroad Feeding System (철도급전시스템의 고조파 평가를 위한 확률론적 방법)

  • Lee, Seung-Hyuk;Song, Hak-Seon;Lee, Jun-Kyong;Kim, Jin-O
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.9
    • /
    • pp.384-391
    • /
    • 2006
  • The harmonic currents generated along with the operating speed of electrical railroad traction are very difficult to analyze because of its nonlinear characteristics. This paper therefore presents probabilistic approach for the evaluation of harmonic currents about the operating speed of the arbitrary single traction. To use probabilistic method for railroad system, PDF(Probability Density Function) using measuring data based on the realistic h 따 monic currents per operating speed is calculated. Measuring data of harmonic current per operating speed is obtained using the result data of PSCAD/EMTDC dynamic simulation based on an IAT(Intra Airport Transit) in Incheon International Airport. The means(expected values) and variances of harmonic currents of single traction also are obtained by the PDF of the operating traction speed and harmonic currents. The uncertainty of harmonic currents can be calculated through the mean and variance of PDF. The probability of harmonic currents generated with the operating of arbitrary many tractions is calculated by the convolution of functions. The harmonics of different number of tractions are systematically investigated to assess the TDD(Total Demand Distortion) for the railroad system. The calculation of TDD was carried out using Monte-Carlo Simulations(MSCs) and the results of TDD evaluation of the power quality in the IAT power feeding system.

Consideration on a extended feeding between AT and BT Feeding System (인접한 AT와 BT급전계통에서의 연장급전방안)

  • Han Moonseob;Lee Jangmu;Jung Hosung;Kim Jurak
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1361-1363
    • /
    • 2004
  • 전기철도에서는 한 전철변전소에서 급전이 용이하지 못할 경우 인근변전소에서 연장급전을 수행한다. 특히 AT(Auto Transformer)와 BT(Booster Transformer)급전시스템이 인접한 경우 연장급전운영을 하기 위한 방안 및 전기적인 요소를 급전계통모의를 통하여 검토하여 그 급전가능성을 제시한다.

  • PDF