• 제목/요약/키워드: Radius

검색결과 4,925건 처리시간 0.028초

Recent results on IceCube multi-messenger astrophysics

  • Rott, Carsten
    • 천문학회보
    • /
    • 제44권2호
    • /
    • pp.54.2-54.2
    • /
    • 2019
  • Mass and radius of a neutron star in low-mass X-ray binary (LMXB) can be estimated simultaneously when the observed light curve and spectrum show the photospheric radius expansion feature. This method has been applied to 4U 1746-37 and the mass and radius were found to be unusually small in comparison with typical neutron stars. We re-estimate the mass and radius of this target by considering that the observed light curve and spectrum can be affected by other X-ray sources because this LMXB belongs to a very crowded globular cluster NGC 6441. The new estimation increases the mass and radius but they do not reach the typical values yet.

  • PDF

CSP/FDR을 이용한 RADIUS 프로토콜 분석 (The Analysis of RADIUS protocol using CSP/FDR)

  • 김일곤;최진영
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2003년도 봄 학술발표논문집 Vol.30 No.1 (A)
    • /
    • pp.239-241
    • /
    • 2003
  • 무선 인터넷의 활성화와 더불어, 사용자 인중(Authentication), 권한 부여(Accounting) 그리고 자원사용(Accounting)의 세가지 AAA 서비스를 효율적으로 제공하기 위해 RADIUS와 같은 AAA프로토콜들이 사용되고 있다. 본 논문에서는 Casper와 CSP를 이용하여 RADIUS 프로토콜을 수행동작을 명세하고, 모델 체킹 도구인 FDR을 사용하여 RADIUS 프로토콜의 안전성을 분석하고자 하였다.

  • PDF

전방 잠금형 금속판을 이용한 요골 원위부 골절수술 후 요골구 접선방향 촬영법의 임상적 유용성 (The Clinical usefulness of the tangential projection view of Radius groove after Distal Radius Fracture operation using the T-type Plat)

  • 서선열;조정희;한만석;김태형;유세종;김용균;한동균
    • 한국산학기술학회논문지
    • /
    • 제14권6호
    • /
    • pp.2760-2766
    • /
    • 2013
  • 서론 : 본 논문은 전방 잠금형 금속판을 이용한 요골 원위부 골절 수술 후 나사못(screw)의 요골구 관통 유무를 확인하기 위한 방법으로 방사선 요골구 접선방향촬영법의 새로운 검사법을 제시하고자 한다. 재료 및 방법 : 요골구 접선방향 촬영 시 요골 원위부 거상 각도는 2.5, 5, 7.5, 10도와 전완골과 방사선 검출기와의 각도를 60, 70, 80도로 각각 변화시켜 촬영한 방사선영상에서 나사못의 요골구 관통유무를 분석하였다. 결과 : 요골구 접선방향 영상에서는 요골구를 관통하지 않은 경우와 요골구 내관통, 요골구 외관통인 경우가 각각 55명(63.95%), 9명(10.47%), 22명(25.58%)으로 분석 되었고, 요골구를 관통한 나사못의 길이는 0.43~2.72mm의 범위로 평균 1.06mm이었다. 요골구가 잘 묘사되는 방사선 촬영법은 요골 거상각도 2.5~7.5도에서 90%이상, 전완골과 방사선 검출기의 각도 70도에서 요골구가 80%이상 잘 묘사되는 것으로 분석 되었다. 결론 : 요골구 접선방향 촬영법은 요골 원위부 거상 각도 5도, 전완골과 검출기의 각도는 70도를 추천 한다.

Determination of an Optimum Orbiting Radius for an Oil-Less Scroll Air Compressor

  • Kim, Hyun-Jin;Lee, Yong-Ho;Kwon, Tae-Hun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제16권4호
    • /
    • pp.124-129
    • /
    • 2008
  • Design practice has been made on an oil-less scroll air compressor as an air supply device for a 2 kW fuel cell system where air pressure of 2 bar and flow rate of 120 liter/min are required. Basic structure of the scroll compressor includes double-sided scroll wrap for the orbiting scroll driven by two crankshafts connected to each other by a timing belt. These features can eliminate thrust surface which otherwise would produce frictional heat and jeopardize reliable operation of the orbiting scroll and the scroll element's deformation as well. This study focuses on optimum scroll wrap design; orbiting radius has been chosen as an independent design parameter. As the orbiting radius changes, scroll sizes such as scroll base plate and discharge port diameters change accordingly. Gas compression-related losses and mechanical loss also change with the orbiting radius. With a scroll base plate diameter of 120mm at most and discharge port of at least 10mm, the orbiting radius should be within the range of 2.5-4.0mm. With this range of the orbiting radius, it was estimated by performance analysis that the compressor efficiency reached to a maximum of ${\eta}_c$=96% at the orbiting radius of $r_s$=3.5mm for the scroll wrap height-to-thickness ratio of h/t=5.

설계일관성을 고려한 도로 곡선반경 산정에 관한 연구 (Development of Estimation of Curve Radii of Road Considering Design Consistency)

  • 박제진;이상하;박광원;하태준
    • 한국도로학회논문집
    • /
    • 제10권2호
    • /
    • pp.125-133
    • /
    • 2008
  • 차량의 주행속도는 설계일관성을 평가하는 주요한 척도로 활용되며 그 중 곡선반경은 여러 연구에서 공통적으로 제시한 주된 요인으로 나타났다. 이에 본 연구에서는 복합선형에서 설계속도별 적정 평면곡선반경 범위기준을 정립하고 운전자의 인지 행태를 나타낼 수 있는 인지반경을 정립하여 입체선형에서 적합한 평면곡선반경을 제시하고자 한다. 첫째, 본 연구에서는 저속차량의 방해요소를 최소화하기 위하여 입체선형을 고려한 도로의 임의지점에서 횡방향 미끄럼 마찰계수와 주행방향 미끄럼 마찰계수를 동시에 고려하여 설계속도와 종단경사별 평면곡선반경을 제시하였다. 둘째, 본 연구에서는 곡선부 인지반경을 통하여 평면 곡선부와 편평한 종단경사가 조합된 경우, 평면 곡선부와 종단곡선부가 조합된 경우를 비교한 후, 곡선부 인지반경을 산정하여 설계속도별 적정 평면곡선반경과 인지반경 비율을 제시하였다.

  • PDF

전완골 분절의 전위 이식술 (Segmented Ulnar Transposition to Defect of Ipsilateral Radius in the Forearm)

  • 정덕환;한수홍;이재훈;권부경
    • Archives of Reconstructive Microsurgery
    • /
    • 제16권2호
    • /
    • pp.125-132
    • /
    • 2007
  • Introduction: Ulna is nearly equal to radius in function and bony architecture and strength in forearm. But in lower extremity, fibula is 1/5 of tibia in anatomic and functional point so we can find fibula transposition is commonly used in defect of tibia. We cannot find other article about segmental forearm bone transposition in man. The purpose of this study was to report our clinical and functional result of undergoing segmented transposition of ipsilateral ulna with its own vascular supply in defect of radius in 6 cases. Material and method: From June 1994 to October 2007, 7 segmented bone transpositional grafts in forearm were performed in Kyung Hee Medical Center. The distribution of age was from 20 years old to 73 years old. There was male in 6 cases and female in 1 case. The causes of operation were giant cell tumor in 1 case and traumatic origin in 6 cases; it was nonunion in 2 cases and fracture with severe comminution in 4 cases. Ipsilaterally segmented ulna keeping its own vascular supply was transported to defect of radius in severe traumatic patients and one patient whose tumor in radius had been excised. Transported ulna was fixed to proximal and distal radius remnants by plate and screw. In one case with giant cell tumor, transported ulna was connected to radius across wrist joint as wrist joint fusion. Joint preserving procedures were performed in 6 cases with crushing injury of radius. Results: We could obtain solid bony union in all cases and good functional results. The disadvantage was relative shortening of forearm, but we could overcome this problem. Conclusion: We think that ipsilateral segmented ulna transposition keeping its own vascular supply to radius can be perfomed with one of procedures in cases with wide defect in radius.

  • PDF

박판의 Z-굽힘가공에서 외측 굽힘반지름 치수의 최소화(샤프에지) 가공법에 관한 연구 (A Research on the Processing Method to Minimize the Outer Radius(Sharp edge) in Sheet Metal Z-bending Work)

  • 윤재웅
    • 한국산학기술학회논문지
    • /
    • 제18권2호
    • /
    • pp.349-355
    • /
    • 2017
  • 프레스금형(press dies)에 의한 굽힘가공(bending work) 이라는 것은 평평한 블랭크(blank)를 필요로 하는 각도(角度)로 굽히는 것이다. 굽힘가공을 하면 굽혀진부분(flange)과 굽혀지지 않은 부분(web)으로 구분되며, 굽힘라인(bending line) 부분에는 굽혀진 각도(bending angle)와 굽힘반지름(bending radius)이 내측과 외측으로 성형된다. 이때, 내측 굽힘반지름의 크기는 제품의 재질별로 최소치수가 제시 된다. 제시된 최소치수 보다 작게 굽히면 절단면 굽힘부위에 덧살이 발생 하거나 외측 굽힘반지름 부위에는 균열(crack)이 생긴다. 굽힘가공에서의 외측 굽힘반지름은 자연적으로 생긴다. 그래서 외측 굽힘반지름 치수를 굽힘펀치와 다이블록으로 조정하면서 필요한 치수로 굽힐수 없다. 굽힘가공에는 V-굽힘, U-굽힘, Z-굽힘, O-굽힘, P-굽힘, 에지굽힘(edge bending), 트위스트굽힘(twist bending), 크림핑(crimping) 등이 있다.이 중에서 Z-굽힘은 굽힘라인이 2개로써 블랭크의 상면(上面)과 하면(下面)에 설정하여 상향(上向)굽힘이나 하향(下向)굽힘으로 작동되는 금형을 사용한다. Z-굽힘을 크랭크굽힘(crank bending) 이라고도 한다. 이런 구조의 금형으로 Z-굽힘가공을 하면 내측반지름은 표준치수로 굽혀진다. 표준치수라는 것은 굽힘가공에서 굽힐 수 있는 최소 굽힘반지름 치수로서 굽힘펀치의 각(角)반지름(Rp)를 뜻한다. 그런데 산업현장에서는 외측 굽힘반지름 치수를 굽힘펀치와 다이블록으로 굽힐수 없는 미세한 샤프에지(sharp edge) 형상인 매우 작은 치수(R=0.2mm)를 필요로하고 있는 바, 본 논문에서는 외측 굽힘반지름 치수를 0.2mm 이하로 굽힐수 있는 Z-굽힘가공 공법을 개발 하고자 하였다.

비축대칭 디프 드로잉 제품에서 펀치 및 다이형상반경의 영향 (The influence of punch and die shape radius in non-axisymmetric deep drawing products)

  • 박동환
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1999년도 추계학술대회논문집
    • /
    • pp.22-25
    • /
    • 1999
  • 'There are a lot of process variables, exerted influence on the formability of products, in deep drawing process. Particularly, it is important that the punch and die shape radius of the process variables. Though researches have been performed on the deep drawing of sheet metal forming, like this study, but it is insufficient the actual circumstances that researches for process variables of the non-axisymmetric deep drawing products. In this study, An effect on thickness distribution is grasped as alteration of the punch and die shape radius in the process of non-axisyrnmetric deep drawing products, and then the optimal punch and die shape radius were presented, they were verified by the numerical analysis method (FEM).

  • PDF

고정된 바깥반경에 기준한 pin 핀의 최적화 (Optimization of a Pin Fin Based on Fixed Outer Radius)

  • 강형석;최수근
    • 산업기술연구
    • /
    • 제28권B호
    • /
    • pp.3-7
    • /
    • 2008
  • A cylindrical pin fin with variable fin base thickness is optimized based on fixed outer radius by using the one dimensional analytic method. Heat loss from the pin fin with fixed outer radius is presented as a function of the fin length. The ratio of in length for optimum heat loss to that for the maximum heat loss is listed. The maximum heat loss and effectiveness and the fin length for the optimum heat loss are presented as a function of fin base thickness and outer radius. One of the results presents the maximum effectiveness decreases rapidly first and then decreases slowly as the fin outer radius increases.

  • PDF