• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.033 seconds

Hybrid Endovascular Repair of Thoracoabdominal Aortic Aneurysm Using Visceral Debranching Technique - 2 case reports- (내장동맥 탈분지술과 혈관내 교정 하이브리드 술식으로 치료한 흉복부대동맥류 치험 - 2예 보고 -)

  • Kim, Jong-Woo;Choi, Jun-Young;Rhie, Sang-Ho;Jang, In-Seok;Sim, Hee-Jae;Shin, Tae-Beom
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.747-752
    • /
    • 2010
  • Surgical repair of thoracoabdominal aortic aneurysm (TAAA) remains a formidable challenge associated with significant rates of mortality and morbidity, especially in patients with high risk. Use of endovascular stent graff in aortic aneurysm disease is now accepted as an alternative treatment to surgery. But the saving of visceral arteries is the chief obstacle to endovascular repair of TAAA. We successfully treated two patients of TAAA with high risk by hybrid procedure including open visceral debranching and concomitant endovascular aneurysm exclusion.

Evaluation of Scatter Radiation in Digital Radiological Condition by using Photostimulated Luminescence (BaFBr:$Eu^{2+}$) (휘진성 형광체 (BaFBr:$Eu^{2+}$)를 이용한 영상의학분야에서 산란선 특성에 관한 평가)

  • Min, Jung-Whan;Han, Seong-Gyu;Kim, Jung-Min;Lee, Joo-Ah;Kim, Ki-Won;Jeong, Hoi-Woun
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.85-91
    • /
    • 2014
  • The purpose of this study is evaluated scatter radiation in digital radiological condition by using photo-stimulated luminescence (BaFBr:$Eu^{2+}$). Experiment condition changed kVp (from 50 kVp to 120 kVp), filed size (from $4{\times}4cm^2$ to $26{\times}26cm^2$) and phantom thickness (from 1 cm to 15 cm). This method was analysed ImageJ and characteristic curve of CR. This results was scatter radiation to primary radiation ratio increased from 50 kVp to 70 kVp, and it was fixed at over 80 kVp. The scatter radiation to primary radiation ratio are increased according to increasing the ratio of field size. Scatter radiation is also increased by increasing the phantom thickness.

Symptomatic Temporomandibular Joint Herniation through the Foramen of Huschke: A Case Report

  • Song, Hee-Jeong;Lee, Yuni;Choi, Hang-Moon;Kim, Young-Jun;Kim, Cheul;Park, Moon-Soo
    • Journal of Oral Medicine and Pain
    • /
    • v.46 no.4
    • /
    • pp.161-164
    • /
    • 2021
  • The foramen of Huschke (FH) or foramen tympanicum is a persistent bony defect connecting the external auditory canal (EAC) to the temporomandibular joint (TMJ). It arises from an incomplete ossification of the tympanic part of the temporal bone that persists after the age of 5. If a herniation exists in the TMJ, otological symptoms may occur. An 80-year-old female patient complained of noise in her left TMJ and otorrhea in her left ear. On her cone beam computed tomography images, there were only degenerative joint disease signs on her left mandibular condyle. However, her computed tomography images revealed that the soft tissue of the TMJ herniate into the EAC. Additional examination was planned for the further evaluation. But the patient no longer visited the hospital due to her systemic health status, and symptoms disappeared spontaneously without any treatments. Usually this type of herniation is very rare, but years of mechanical stress from mastication may result in weakening and widening of the foramen with age. Therefore, although FH is usually congenital, sometimes it may be acquired in the elderly. The treatment plan should be determined in consideration of the patient's symptom level and the patient's general health status. If the clinical symptoms are not severe, no treatment is required.

A Study on the Selection of the Main Factors of Radiation Risk Index Model for assessing risk in Nondestructive Test workplace (방사선투과검사작업장 위험성 평가를 위한 방사선 위해도 지수 모델 주요인자 선정에 관한 연구)

  • Gwon, Da Yeong;Han, Ji young;Bae, Yu-Jung;Kim, Byeong-soo;Kim, Yongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.459-466
    • /
    • 2018
  • Risk of radiation worker and radiation workplace are being mainly assessed by exposure dose. But, the radiation used in radiation workplace and the work environment are different. Because the nondestructive work environment varies depending on the work subject, the existence and nonexistence of shielding board, and so on. So, we need to consider the various factors in effective radiation protection aspect. We conducted a survey of radiation workers with over two years' experience in NDT workplace and heared the thoughts of experts. As a result, radiation source, exposure dose, current status of workplace management, workers with personel dosimetry problem and status of periodic regulatory inspection were chosen as main factors of radiation risk index model. Also, we primarily set weighting factors in order of importance based on questionnaires. Finally, we determined weighting factor for details of main factors through the professional advice. Therefore, we will be able to develop the radiation risk index model for assessing the risk of nondestructive test workplace based on main factors that are selected through this study.

A Research on Superparamagnetic Iron Oxide Nanoparticles' Toxicity to U373MG Cell and its Effect on the Radiation Survival Curve (산화철 나노입자의 U373MG 세포 독성평가 및 방사선 세포생존 곡선에 미치는 영향에 대한 연구)

  • Kang, Seonghee;Kim, Jeonghwan;Kim, Dokyung;Kang, Bosun
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.507-513
    • /
    • 2012
  • This research was performed to evaluate the superparamagnetic iron oxide nanoparticles'(SPIONs) cell toxicity and to measure the radiation cell survival curve changes of SPIONs-uptake glioblastoma multiforme cells. The results could be practically used as the fundamental data to ameliorate proton beam cancer therapy, for example, providing necessary GBM treatment dose in the proton beam therapy when the therapy takes advantage of SPIONs. The assessment of the toxicological evaluation of synthesized SPIONs was accomplished by MTT assay as an in vitro experiment. The results showed no meaningful differences in the cell survival rate at the $1-100{\mu}g/ml$ SPIONs concentrations, but the cell toxicity was shown as the cell survival rate decreased up to 74.2% at the $200{\mu}g/ml$ SPIONs concentration. Then, we measured each radiation cell survival curve for U373MG cells and SPIONs-uptake U373MG cells with 0~5 Gy of proton beam irradiations. It is learned from the analysis of the experimental results that the SPION-uptake cells' radiation survival rate was more rapidly decreased as the irradiation dose increased. In conclusion we confirmed that SPIONs-uptake in U373MG cells induces cell death at the much less dose than the lethal dose of SPION-non-uptake cell. This research shows that the therapeutic efficacy of glioblastoma multiforme treatment in proton beam therapy can be improved by SPIONs targeting to the GBM cells.

Empathy and Mood Awareness Reflected in the Resting-State Brain Metabolic Activity in the Patients with Schizophrenia and Normal Subjects (안정상태 뇌 대사 활성도에 반영된 정신분열병 환자와 정상인에서의 감정이입과 기분인식 관련 뇌 영역)

  • Park, Il Ho;Chun, Jiwon;Jung, Young Chul;Seok, Jeong Ho;Park, Hae-Jeong;Lee, Jong Doo;Kim, Jae-Jin
    • Korean Journal of Biological Psychiatry
    • /
    • v.14 no.2
    • /
    • pp.129-141
    • /
    • 2007
  • Objectives : Empathy has been conceptualized as the ability of emotional resonance and perspective-taking. Emotional awareness has been proposed as the basis of empathy. In this study we examined the relationship between empathy and mood awareness and their neural correlates in resting-state activity in normal controls and patients with schizophrenia. Methods : Empathy and mood awareness scale scores were compared between 29 patients with schizophrenia and 21 normal controls by voxel-based t-tests and voxel-based correlation analyses of resting-state $^{18}F$-FDG PET images. Results : Empathy and mood labeling scale scores were significantly decreased in schizophrenic patients. Mood monitoring was positively correlated with empathy score in normal controls, but not in schizophrenic patients. In normal controls, empathy was positively correlated with resting-state activities in the intraparietal sulcus and mood monitoring was positively correlated with the temporal pole, frontopolar cortex, inferior temporal gyrus, entorhinal cortex and the subgenual prefrontal cortex resting activities. The orbitofrontal cortex resting activity was positively correlated with mood monitoring-related subgenual prefrontal cortex activity in the normal controls. Patients with schizophrenia showed decreased orbitofrontal resting activity and loss of its correlations with mood monitoring-related regional activities. Conclusion : This study showed that alteration in the resting-state activity in schizophrenia may reflect dysfunctional empathy and distorted characteristic of emotional awareness. However, the resting-state activity may not reflect the relationship between emotional awareness and empathy.

  • PDF

Impact of Contrast Agent for PET Images with CT-based Attenuation Correction (CT 영상을 이용한 감쇠 보정 시 조영제가 PET 영상에 미치는 영향)

  • Son Hye-Kyung;Turkington Timothy G.;Kwon Yun-Young;Jung Haijo;Kim Hee-Joung
    • Progress in Medical Physics
    • /
    • v.16 no.4
    • /
    • pp.192-201
    • /
    • 2005
  • Experiments and simulation were done to study the impact of contrast agent when CT scan was used to attenuation correction for PET Images in PET/CT system. Whole body phantom was imaged with various concentration of iodine-based contrast agent using CT. Mathematical emission and transmission density map with liver were made to simulate for whole body FDG Imaging. A variety of factors were estimated, including non-uniform enhancement of contrast agent, concentration and distribution size of contrast agent, noise level, image resolution, reconstruction algorithm, hypo-attenuation of contrast agent, and different time phases for contrast agent. Experimental studies showed that Hounsfield unit depends on the concentration of contrast agent and tube voltage. From the simulation data, contrast agents Introduced artifacts and degraded image quality on the attenuation-corrected PET images. The severity of these effects depends on a variety of factors, including the concentration and distribution size of contrast agent, the noise levels, and the Image resolution. These results Indicated that the impact of contrast agents should be considered with a full understanding of their potential problems in clinical PET/CT images.

  • PDF

Compared the Causes of Problematic Chemo-Ports According to the Types of Chemo-Ports(Valved, vs. Non-Valved) (Valve포트와 Non-Valved포트 사용에 따른 문제점의 비교 분석)

  • You, In-Gyu;Lim, Cheong-Hwan;Han, Beom-Hee;Jung, Hong-Ryang;Joo, Yeong-Cheol
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.35-41
    • /
    • 2011
  • Total implanted central venous port (TIAP, Chemoport) is widely used in oncology patients because it does not require external dressing and restricts patient activity. Chemoport only requires monthly flushes of heparinized saline to keep the patency of the catheter and probably less prone to infectious complications than tunneled catheter. Despite the extensive use of permanent central venous access in oncology patients, there are only few reports about clinical experience of the Groshong catheter. The purpose of this study is to compare the complication rate between the traditional open-ended (non-valved) chemoports and valved chemoports (Groshong catheter connected to TIAP). During 5 years (Jan 2006 to May 2010), 438 patients received chemoport insertion procedure in our interventional radiology department. Among them 30 patients was referred to our department for problematic chemoports. We compared the cause of problematic chemoports between two types of chemoports (valved, vs. non-valved). Valved chemoports had higher referral rates than non-valved chemoports. When there is a need to insert valved port, different method of insertion and maintenance procedure seems to be necessary. More than 20 ml of flusing with heparinized saline after blood sampling could be a good suggestion. Adequate care of chemoport is essential for long patency. Also following the guideline from the manufacturing company is necessary.

Diffusion Tensor Imaging and Cerebrospinal Fluid Flow Study of Cine Phase Contrast in Normal Cervical Spinal Cords (정상인 경수에 대한 확산텐서영상과 PC기법을 이용한 뇌척수액 속도 측정에 관한 연구)

  • Son, B.K.;Kwak, S.Y.;Han, Y.H.;Yoo, J.S.;Kim, O.H.;Ko, H.Y.;Mun, C.W.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.123-132
    • /
    • 2013
  • Purpose : We report the results of the various parameters of diffusion tensor imaging (DTI) and CSF flow study of the cervical spinal cord using magnetic resonance (MR) imaging techniques. Materials and Methods: Intramedullary FA and MD were measured in the gray matter and posterior cord of the white matter and both lateral cords of the white matter at the C2-3, C4-5, C5-6 spinal levels. For the CSF flow study, velocity encoding was obtained at the C2-3, C4-5, C5-6 spinal levels. Results: There was a significant difference of the FA and MD between the white matter and gray matter (p < 0.05). The FA of the gray matter was significantly different according to the cervical spinal cord levels (p < 0.05). Otherwise, the FA and MD parameters were not significantly different (p > 0.05). The mean peak systolic velocity and mean peak diastolic velocity were $5.18{\pm}2.00cm/sec$ and $-7.32{\pm}3.18cm/sec$, respectively from C2 to C6 spinal cords. There was no significant difference in these velocities among the cervical spinal cord (p > 0.05). Conclusion: This basic information about DTI and CSF dynamics of the cervical spinal cord may be useful for assessing cervical spinal cord abnormalities using MR imaging.

Evaluation and Comparison of Signal to Noise Ratio According to Histogram Equalization of Heart Shadow on Chest Image (흉부영상에서 평활화 시 심장저부 음영의 신호 대 잡음비 비교평가)

  • Kim, Ki-Won;Lee, Eul-Kyu;Jeong, Hoi-Woun;Son, Jin-Hyun;Kang, Byung-Sam;Kim, Hyun-Soo;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.197-203
    • /
    • 2017
  • The purpose of this study was to measure signal to noise ratio (SNR) according to change of equalization from region of interest (ROI) of heart shadow in chest image. We examined images of chest image of 87 patients in a University-affiliated hospital, Seoul, Korea. Chest images of each patient were calculated by using ImageJ. We have analysis socio-demographical variables, SNR according to images, 95% confidence according to SNR of difference in a mean of SNR. Differences of SNR among change of equalization were tested by SPSS Statistics21 ANOVA test for there was statistical significance 95%(p < 0.05). In SNR results, with the quality of distributions in the order of original chest image, original chest image heart shadow and equalization chest image, equalization chest image heart shadow(p < 0.001). In conclusion, this study would be that quantitative evaluation of heart shadow on chest image can be used as an adjunct to the histogram equalization chest image.