Evaluation of Scatter Radiation in Digital Radiological Condition by using Photostimulated Luminescence (BaFBr:) |
Min, Jung-Whan
(Department of Radiological Science, Shin-Gu University)
Han, Seong-Gyu (Department of Bio-convergence engineering, Graduate school, Korea University) Kim, Jung-Min (Department of Radiological Science, Korea University) Lee, Joo-Ah (Department of Oncology, Catholic University of Korea Incheon St.Mary's Hospital) Kim, Ki-Won (Department of Radiology, Samsung Medical Center) Jeong, Hoi-Woun (Department of Radiological Science, Beakseok Culture University) |
1 | H. P. Chan and K. Doi : Physical characteristics of scattered radiation and the performance of antiscatter grids in diagnostic radiology, Radiographics, 2(3), 378-406, 1982 DOI |
2 | Jung-Min Kim, Jung-Whan Min, Hoi-Woun eong et al: The Noise Evaluation for Ragius 150 CR System. Journal of Radiological Science and Technology, 29(4), 237-240, 2006 |
3 | Jung-Min Kim: Edge Profile Correction for Modulation Transfer Function on Digital X-ray Imaging System. Journal of Radiological Science and Technology, 30(3), 251-257, 2007 |
4 | Jung-Min Kim, Ki-Sung Lee, You-Hyun Kim: Correction Method of Wiener Spectrum (WS) on Digital Medical Imaging Systems. Journal of Radiological Science and Technology, 32(1), 17-24, 2009 |
5 | Hoi-Woun Jeong, Jung-Whan Min, Jung-Min Kim et al: Performance characteristic of a Cs I (TI) Flat panel detector radiography system. Journal of Radiological Science and Technology, 35(2), 109-117, 2012 |
6 | Jung-Whan Min, Hoi-Woun Jeong, Jung-Min Kim et al: Comparison of Noise Power Spectrum Methodologies in Measurements by Using Megavoltage X-ray Energies. Journal of Korean Physics Society 60, 129-136, 2012 DOI ScienceOn |
7 | Jung-Whan Min, Hoi-Woun Jeong, Jung-Min Kim et al: Performance of an Edge Block Used in a Configuration Detector: Image Quality Measurements. Journal of Korean Physics Society 64, 732-739, 2014 DOI ScienceOn |
8 | International Electrotechnical Commission : Medical electrical equipment - Characteristics of digital X-ray imaging devices-Part 1 : determination of the detective quantum efficiency. IEC 62220-1, 2003 |
9 | NIH, ImageJ : http://rsb.info.nih.gov/ij/ |
10 | Simone Cardoso, Odair Goncalves, Helio Schechter : Evaluation of scatter-to-primary ratio in radiological conditions, Applied Radiation and Isotopes, 7, 544-548, 2009 |
11 | Paul C. Johns and Martine J. Yaffe : Scattered radiation in fan beam imaging systems. Med. Phys., 9(2), 231-239, 1982 DOI ScienceOn |
12 | Joon Huh, Chang-Kyun Kim, Jung-Min Kim et al: Influence of X-ray Tube Voltage and Object on X-ray Quality and Dose. Journal of Radiological Science and Technology, 7(1), 41-46, 1984 |
13 | KFDA: A guide for general radiology of the patient dose recommend. 2012 |
14 | Jung-Min Kim, Jung-Whan Min, Hoi-Woun Jeong et al: Correction Method of slit Modulation Transfer function on Digital Medical Imaging System. Journal of Radiological Science and Technology, 29(3), 133-139, 2006 |