• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.024 seconds

Enhancement of Image Quality Using Detector Filter (검출기 필터를 이용한 화질의 향상)

  • Lim, Jong-Nam;Kim, Hyung-Tae;Kim, Min-Hye;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.451-456
    • /
    • 2016
  • Radiation dose to patient is unavoidable when diagnosis is carried out using X-ray. Radiation diagnosis using dual energy X-ray was examined to verify the possibility of medical applications by SNR and image scoring. The dual energy X-ray was realized by combining together two image plates and filter of 0.5 mm thick Cu or Al. Under one X-ray exposure, contrast enhanced image was obtained using two images of image plates. The enhanced image showed higher SNR and image score compared to the first image which was the image recorded with the first image plate. The dual energy X-ray technique would be a very useful method for obtaining higher SNR image and for realizing very low dose, and could be applied to medical applications.

Property of Carbon Layer for C/W Multilayer Mirror (C/W 다층박막 거울의 탄소층 특성 Property of Carbon Layer for C/W Multilayer Mirror)

  • Park, Byoung-Hun;Choi, Hyung-Wouk;Oh, Sun-Ju;Yoon, Kwon-Ha;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.4
    • /
    • pp.33-36
    • /
    • 2010
  • Multilayer mirrors are very useful for applications of high energy X-ray. X-rays of high energy require very small thickness, a few nanometers, in the d-spacing of a multilayer mirror. Each layer is composed of a multilayr mirror influences to interfacial roughness or interdiffusion which gives rise to degrade specular reflection. Carbon layer of 1 nm thick in a C/W multilayer mirror of 3.25 nm d-spacing was examined. Carbon as well as tungsten layers were very uniform, and there was no micro-structure in carbon layers. However, interdiffusion between carbon and tungste layers was observed by a transmission electron microscope.

The Evaluation of Space Dose Distribution for Digital Mammography Equipment (디지털 유방촬영장비에 관한 공간선량율 평가)

  • Jung, Hongmoon;Jung, Jaeeun;Hyun, Hyejin;Won, Doyeon
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.61-65
    • /
    • 2015
  • Mammography equipment is an essential detector for making an early diagnosis of female's breast lesion. Recently, in most hospitals, a digital mammography detector is used due to the wide and consistent supply of digital mammography equipment. However, the average effective radiation is increasing due to the indiscreet use of CR or DR mammography. The purpose of this study is to recognize the possible indirect radiation damage, which can be occurred due to an excessive effective exposure of radiation, by evaluating spacial radiation rate of the digital mammography detector used for female patient. Consequently, the high mount of spacial radiation showed digital mammography equipment on the horizontal direction. Considering the result, digital mammography equipment should be installed by avoiding along the horizontal direction.

Analysis of Hospital Infection Control Awareness of Hospital Health Care Workers in Busan (부산지역 의료종사자들의 병원감염관리 인식 분석)

  • Seo, Min-Jung;Kim, Chang-Soo;Ye, Soo-Young;Kim, Jung-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.351-358
    • /
    • 2016
  • This study surveyed the health professionals in Busan with regard to their awareness of nosocomial infection control. According to the conclusion of this study, first, the level of awareness and performance of personal hygiene management, equipment sanitation management, and cleaning and environmental management increased as the level of education decreased. Also, when it comes to personal hand-washing, the level of awareness was higher among workers in primary, secondary and other medical institutions, where as the level of performance was higher among the group of medical practitioners. The differences were statistically significant at a significance level of .001. Medical practitioners also showed a higher level of awareness and performance of hospital sanitation management, which was statistically significant. Overall, as the level of awareness was lower than the level of performance, it seems that individuals need to thoroughly practice infection control, and realistic improvement measures need to be devised.

Extravasation Injury of Contrast Media in the Neck and Thorax During MDCT Scanning with 3D Image Reformation Findings (CT검사에서 조영제의 혈관외유출에 의한 목 및 흉부 손상의 3차원 재구성 영상)

  • Kweon, Dae-Cheol;Jang, Keun-Jo;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.281-287
    • /
    • 2007
  • Contrast media may cause tissue injury by extravasation during intravenous automated injection during CT examination. Here, we present a study in which contrast media extravasation was detected and localized in the neck and thorax by three-dimensional(3D) CT data reformation. The CT studies of the extavasation site were performed using a 3D software program with four different display techniques axial, multi planar reformation(MPR), maximum intensity projection(MIP), and volume rendering displays are currently available for reconstructing MDCT data. 3D image reconstructions provide accurate views of high-resolution imaging. This paper introduces extravasation with the MDCT and 3D reformation findings of contrast media extravasation in neck ant thorax. The followed injection of the external jugular vein into an existing intravenous catheter and a large volume of extravasation was demonstrated on by 3D MDCT.

  • PDF

Effects of ADMIRE Algorithms on Fat Measurements Using Computed Tomography (CT) (CT를 이용한 지방측정에 ADMIRE 알고리즘이 미치는 영향)

  • Lee, Chang Wook;Lee, Sang Heon;Im, In Chul;Lee, Hyo Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.465-472
    • /
    • 2019
  • To investigate the effects of iterative reconstruction algorithms on fat measurements using computed tomography (CT), we comparatively and quantitatively analyzed the ratios of visceral, subcutaneous, and visceral-subcutaneous fat areas as well as the variations of HU and noise of visceral and subcutaneous fat using ADMIRE strength and attempted to identify any difference between them. Experimental results showed that no statistically significant difference existed among the visceral, subcutaneous, and visceral-subcutaneous fat area ratios HU of visceral fat area and HU of subcutaneous fat area when applying ADMIRE as compared with existing conventional filtered back projection algorithms. However, as the ADMIRE strength increases, the noise of visceral and subcutaneous fat decreases by up to 12.1% and 19.2%, respectively. In conclusion, iterative reconstruction algorithms have no effect on the visceral, subcutaneous, and visceral-subcutaneous fat area ratios, which are indicators of fat measurement using CT.

Evaluating the Effects of Inferiority Management Using a Group Counseling Program for University Students in Health Science (보건계열 대학생의 집단상담 프로그램을 활용한 열등감 관리의 효과 분석)

  • Lee, Myung Hwa;Park, Young Joon;Jang, Hyon Chol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.557-563
    • /
    • 2019
  • The objective of this study was to identify factors affecting the positive and negative responses of undergraduate students to inferiority by using a group counseling program to manage the inferiority of undergraduate students majoring in health science. This study sampled 30 undergraduate students attending the health science department of S University and divided them into a treatment group and a control group. The treatment group received an inferiority management group counseling program twice a week 120 minutes each from November 20, 2018, to January 2, 2019 eight sessions in total. The inferiority response criterion was applied before-treatment, after-treatment, and follow-up to verify the effectiveness of the program. The analysis results showed that the inferiority management group counseling program significantly decreased the negative response of undergraduate students to inferiority and significantly increased the positive response to inferiority. These results suggest that the inferiority management counseling program can lower the negative attitude and enhance the positive attitude toward the inferiority, which is caused by comparing themselves with their peers.

A Research Study on the Education System for Radiological Technologists and the Public health policy (방사선사의 교육시스템과 보건정책에 대한 조사 연구)

  • Jung, Hong-Ryang;Kim, Myeong-Soo;Choi, Jin
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.67-74
    • /
    • 2004
  • In order to assess policies for training of radiological technologists and public health, this study was conducted from the mid July to the end of August 2003 to the subjects of 890 radiological technologists who work at 44 general hospitals in 16 cities and provinces of the country. For this purpose, an analysis of variance was performed by regions divided in Capital city, metropolitan areas and small- and medium-sized cities as well as by length of service. The outcomes look as follows : 1. From the analysis of replies to questions about the government health policy for radiological technologists, high scores were given to the items: "the Law of Medical Engineers should be revised from the pattern of supervision to assignment" and "the medical institutions should be legally obliged to secure certain number of radiological technologists". 2. From the analysis of variance by regions and groups, there was difference by regions in the items: "demand and supply of radiological technologists should be controlled" and "the license number of radiological technologists should be indicated in the medical insurance bill"(p<0.000). 3. From the analysis of variance as to training of radiological technologists, a significant difference was found by length of service in the items: "it is necessary to open a 4-year department of radiology and to revise curriculum" and "the legal system to indicate license number of radiological technologists in the medical insurance bill should be introduced". 4. The analysis of variance by length of service revealed that those who have served for more than 20 years favored "it is necessary to open a 4-year department of radiology and to revise curriculum" higher than those who have served for less than 5 years, showing a tendency the longer they work, the stronger they feel necessity".

  • PDF

Comparison of Image Quality and Dose between Intra-Venous and Intra-Arterial Liver Dynamic CT using MDCT (MDCT를 이용한 역동적 간 컴퓨터단층촬영 검사에서 정맥과 동맥 주입법에 따른 영상의 화질 및 선량 비교)

  • Ji-Young, Kim;Ye-Jin, Cho;Hui-Hyeon, Im;Ju-Hyung, Lee;Yeong-Cheol, Heo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.123-129
    • /
    • 2023
  • The purpose of this study was to analyze differences in imaging quality and dose difference between intra-venous (IV) and intra-arterial (IA) liver dynamic computed tomography (CT). Herein, retrospective, blinded analysis was conducted to analyze signal-to-noise and contrast-to-noise ratios in cases of patients who underwent IV or IA liver dynamic CT for transarterial chemoembolization (TACE), an interventional procedure for hepatocellular carcinoma. The dose length product (DLP) value stored in Picture Archive and Communication System (PACS) was used to calculate the effective dose and thereby compare differences in the dose between the two methods. The mean liver and spleen signal to noise ratio (SNR) was greater in IV-liver dynamic CT than in IA-liver dynamic CT; however, contrast to noise ratio (CNR) was higher in IA-liver dynamic CT than in IV-liver dynamic CT. However, there were no differences in DLP and effective dose between the two methods. In conclusion, our findings showed that IA-liver dynamic CT showed a similar effective dose and superior CNR compared with IV-liver dynamic CT. Further studies must analyze 3D angiography CT of the hepatic artery to clearly distinguish the feeding artery, which is the essential step in interventional procedures for hepatocellular carcinoma.

Analysis of the Influence of Examination Gowns on the Image and the Suitable Fabrics for Chest AP Examinations on DR X-ray Systems (디지털 X-선 시스템에서 흉부 전·후 방향 검사 시 검사복이 영상에 미치는 영향과 적정 검사복 원단의 분석)

  • Eun-Bi Baek;Yoo-Jin Jeong;Su-Bin Lim;Sang-Jo Park;Yeong-Cheol Heo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.865-872
    • /
    • 2023
  • The purpose of this study was to analyze fabrics suitable for use as examination gowns to determine whether examination gowns affect imaging during anterior to posterior chest examinations(Chest AP) on a digital X-ray system. Examination gowns in use at five medical centers in Seoul were collected and included modal, tencel, cotton, and rayon fabrics. The selection of fabrics was based on studies that reported fabrics with good tactile, absorbent, stretchable, and wrinkle resistance. Phantoms of five hospital gowns and four fabrics, arranged in overlapping layers from one to eight, were created and examined on a digital X-ray system in both Chest AP examination. The images examined were subjected to a first-step profile analysis, a second-step signal intensity averaging analysis, and a third-step microscopic analysis. The results showed that all nine materials had an increasing impact on the image as the number of layers of fabric increased, with the modal fabric having the least impact on the image in the first, second, and third analyses. In conclusion, as the resolution of digital x-ray systems increases, the impact of examination clothing on the image will increase, and research to find suitable materials for examination clothing will continue to be necessary.