• Title/Summary/Keyword: Radiology Clinic

Search Result 251, Processing Time 0.023 seconds

Prevalence Of Radiographic Ankle Osteoarthritis (방사선적 족관절염의 유병율)

  • Moon, Woo-Nam;Lee, Kyung-Sang
    • Journal of Korean Foot and Ankle Society
    • /
    • v.5 no.1
    • /
    • pp.13-17
    • /
    • 2001
  • Objectives: This study was done to determine the prevalence of radiographic ankle osteoarthritis (OA) in Korean women with clinical primary ankle OA. Methods: This analysis involved 160 Korean women who visited our out patient clinic due to ankle joint pain. Ankle AP and lateral weight-bearing radiographs were evaluated retrospectively to check whether they have radiographic OA or not. Radiographs were read for features of ankle OA using School classification. Demographic factors and radiographic findings in both radiographic ankle OA group and non-radiographic ankle OA group were analyzed by the student t-test, the chi square test and the Pearson's analysis. A p value <0.05 was considered significant. Results: The prevalence of radiographic ankle OA in Korean women is 18.2 % in patient between 18 and 39 years and is 55.6 % in patient over 40. There was significant difference between two groups with age (P<0.001) and relatively strong correlation between radiographic OA and age (r=0.474, P<0.001). Conclusion: These results show that the prevalence of Korean women with radiographic changes of ankle OA was 45 % and there was relatively strong correlation between age and radiographic ankle OA.

  • PDF

Intraventricular Vancomycin Therapy for Intractable Bacillus cereus Ventriculitis

  • Hahn, Jong Woo;Ju, Hee young;Park, Meerim;Yi, Eun Sang;Park, Byung-Kiu;Shin, Sang-Hoon;Lee, Sang-Hyun;Park, Hyeon Jin;Kang, Ji-Man
    • Pediatric Infection and Vaccine
    • /
    • v.26 no.2
    • /
    • pp.124-128
    • /
    • 2019
  • Bacillus cereus causes serious central nervous system infections, especially in immunocompromised patients. Successful treatment requires adequate antimicrobial concentrations in the cerebrospinal fluid; however, in some cases, achieving this with systemic treatment alone is difficult. We treated intractable B. cereus ventriculitis with intraventricular vancomycin, with no major adverse events.

Comparative Analysis According to Acquisition Type by Using the Resolution Phantom for Mammography Equipment (유방촬영의 영상획득 방법에 따른 해상력 차트의 비교 분석)

  • Kim, Jae-Hoon;Ji, Yun-Sang;Dong, Kyung-Rae;Kwak, Jong-Gil
    • Journal of Radiation Industry
    • /
    • v.12 no.4
    • /
    • pp.287-290
    • /
    • 2018
  • Nowadays, diseases related with breast are increasing rapidly and because of this high quality of resolution images is required to get clear detail specially for early detection and diagnosis. It has a tendency to use digital equipments than analog one in clinic. In this experiment, DR, CR, and Film are used for the resolution applied by AEC. Resolution phantom in DR was $7LP{\cdot}mm^{-1}$ in both verticality and horizontality. In CR, however, it was $6LP{\cdot}mm^{-1}$ in both which was lower this standard. The resolution stayed in range of standard in Film but it showed differences between $11{\sim}14LP{\cdot}mm^{-1}$ Overall, the difference of resolution was displayed Film, DR and CR, in order, which means the study is needed for more high quality of digital images.

Outcome of open reduction and Kirschner wire fixation in pediatric radial neck fracture

  • Rouhani, Alireza;Chavoshi, Mohammadreza;Sadeghpour, Alireza;Aslani, Hossein;Mardani-Kivi, Mohsen
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.4
    • /
    • pp.239-244
    • /
    • 2021
  • Background: Radial neck fracture in children is rare. This study attempted to evaluate the outcome of surgically treated patients and any associated complications. Methods: This study evaluated 23 children under 15 years of age with radial neck fracture who were treated with open reduction between 2006 and 2016 to determine their range of motion, postoperative complications, and radiographic outcomes. The results were assessed clinically using the Mayo clinic elbow performance score. Results: The mean follow-up duration for patients was 34.6 months. The average postoperative angulation was 3.6°. Hypoesthesia was reported in only 9% of patients, and none of the patients complained of postoperative pain. The postoperative X-ray results were excellent in 60% and good in 40%. No radiographic complications were identified. The elbow score was excellent in 87% and good in 13% (mean score, 96.74). There was a statistical relationship between range of motion limitations and age, degree of fracture, initial displacement, and surgical pin removal time. Conclusions: Although most patients accept the closed reduction method as a primary treatment, the present study suggests that an open-reduction approach has been associated with optimal therapeutic outcomes for patients in whom closed reduction was not satisfactory or indicated.

Biliary ascariasis misidentified as a biliary stent in a patient undergoing liver resection

  • Hochang Chae;Suk Won Suh;Yoo Shin Choi;Hee Ju Sohn;Seung Eun Lee;Jae Hyuk Do;Hyun Jeong Park
    • Parasites, Hosts and Diseases
    • /
    • v.61 no.2
    • /
    • pp.194-197
    • /
    • 2023
  • Ascaris lumbricoides causes one of the most common soil-transmitted helminthiases globally. The worms mostly infect the human small intestine and elicit negligible or nonspecific symptoms, but there are reports of extraintestinal ectopic ascariasis. We describe a rare case of biliary ascariasis mistaken for biliary stent in a 72-year-old female patient with a history of liver resection. She visited our outpatient clinic complaining of right upper quadrant pain and fever for the past week. She had previously undergone left lateral sectionectomy for recurrent biliary and intrahepatic duct stones 2 years ago. Besides mildly elevated gamma-glutamyl transferase levels, her liver function tests were normal. Magnetic resonance cholangiopancreatography revealed a linear filling defect closely resembling an internal stent from the common bile duct to the right intrahepatic bile duct. A live female A. lumbricoides adult worm was removed by endoscopic retrograde cholangiopancreatography (ERCP). Despite a significant decrease of the ascariasis prevalence in Korea, cases of biliary ascariasis are still occasionally reported. In this study, a additional case of biliary ascariasis, which was radiologically misdiagnosed as the biliary stent, was described in a hepatic resection patient by the worm recovery with ERCP in Korea.

Mucosa-Associated Lymphoid Tissue Lymphoma of the Labial Minor Salivary Glands: Case Report

  • Jung Eun Lee;Dawool Han;Hyun Sil Kim;Chena Lee;YounJung Park;Jeong-Seung Kwon
    • Journal of Oral Medicine and Pain
    • /
    • v.49 no.1
    • /
    • pp.22-27
    • /
    • 2024
  • A 74-year-old female presented with a complaint of dry mouth, continuous spontaneous burning sensation in the tongue, and asymptomatic submucosal soft tissue mass on both sides of the lower labial mucosa. She refused to undergo total excision of the mass due to concern about the possibility of complications such as nerve damage because of the large size of the mass. As her clinical features and magnetic resonance imaging indicated the possibility of Sjögren's syndrome, a biopsy of the minor salivary gland of the right lower lip was performed. Consequently, she was diagnosed with mucosa-associated lymphoid tissue (MALT) lymphoma. Although the patient had typical signs and symptoms of Sjögren's syndrome, the histopathological result of MALT lymphoma made it impossible to determine whether the patient had a history of Sjögren's syndrome. For patients with risk factors for MALT lymphoma, such as Sjögren's syndrome, a biopsy of the labial minor salivary gland with immunohistochemical staining can be helpful in the diagnosis of not only Sjögren's syndrome but also MALT lymphoma.

What Is Normal for an Aging Heart?: A Prospective CMR Cohort Study

  • Johannes Kersten;Carsten Hackenbroch;Muriel Bouly;Benoit Tyl;Peter Bernhardt
    • Journal of Cardiovascular Imaging
    • /
    • v.30 no.3
    • /
    • pp.202-211
    • /
    • 2022
  • BACKGROUND: This study aims to investigate normal changes throughout aging of the heart in cardiac magnetic resonance (CMR) imaging in healthy volunteers. While type 2 diabetes mellitus is a frequent finding in the elderly population, also the influence of this circumstance in otherwise healthy persons is part of our study. METHODS: In this prospective single-center trial, 75 healthy subjects in distinct age groups and 10 otherwise healthy diabetics were enrolled. All subjects underwent functional, flow sensitive, native T2- and T1-mapping in a 1.5T CMR scanner. RESULTS: No differences in right and left ventricular ejection fractions were observed between aging healthy groups. Bi-ventricular volumes lowered significantly (p<0.001) between the age groups. There was also a significant decrease in myocardial T1 values, aortic distensibility, and left ventricular peak diastolic strain rates. There were no differences in T2 mapping and the other deformation parameters. Patients with type 2 diabetes mellitus had lower end-diastolic volume indexes; all the other measurements were comparable. CONCLUSIONS: Aging processes in the healthy heart involve a decrease in ventricular volumes, with ejection fractions remaining normal. Stiffening of the myocardium and aorta and a decrease in T1 values are potential indications of age-related remodeling. Type 2 diabetes mellitus seems to have no major influence on aging processes of the heart.

The Study of patient rotation angle to get the scapular true lateral image in scapular lateral projection (견갑골 측방향 촬영에서 견갑골 정측면상을 얻기 위한 환자의 회전각도에 관한 연구)

  • Park, Ki-Bong;Kang, In-Hyi;Choi, Nam-Kil;Jang, Young-Il;Jeon, Ju-Seob
    • Journal of radiological science and technology
    • /
    • v.28 no.3
    • /
    • pp.203-209
    • /
    • 2005
  • Objective True lateral scapular image was very important to diagnosis the scapular fracture and dislocation induced by traumatic injury. The aim of this study was to know the patient rotation angle to be showing the scapular true lateral in Korean. Subjects and Materials Thirty patients(22men, 8 women, mean ages 53.4)with scapular pain, had supine anteroposterior projection taken with $32^{\circ}$, $37^{\circ}$, $42^{\circ}$ trunk rotation angle changing the manual angulation material. Radiographs were evaluated independently by 5 experienced observers(1 orthopedics surgery specialist, 1 diagnostic radiology specialist, 3 radiological technologist) They assessed overlab of vertebral border and axillary border of scapular as follows; Totally overlapping of vertebral border and axillary border is 4, partially overlapping is 3, not overlapping is 2 and oblique location with two borders is 1. All observers scored using by PACS monitor. Results $32^{\circ}$ trunk rotation was scored $1.53{\pm}0.39$, $37^{\circ}$ trunk rotation was scored $3.83{\pm}0.15$ and $42^{\circ}$trunk rotation was scored $2.17{\pm}0.43$. There was no difference(p<0.05) between group of more than 100cm of the girth of the chest and group of less than 100cm. Similarly, men and women group showed no difference(p<0.05) with trunk rotation statistically. Conclusions There was no result of trunk rotation angle to radiograph the true scapular lateral image up to date. This studies were summarized as follows; Adaptation of $37^{\circ}$ trunk rotation was the best to show the true scapular lateral image in Korean. Our results were very useful to get the true scapular lateral images in clinic.

  • PDF

Comparison of Center Error or X-ray Field and Light Field Size of Diagnostic Digital X-ray Unit according to the Hospital Grade (병원 등급에 따른 X선조사야와 광조사야 간의 면적 및 중심점 오차 비교)

  • Lee, Won-Jeong;Song, Gyu-Ri;Shin, Hyun-yi
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.245-252
    • /
    • 2020
  • The purpose of this study was intended to recognize the importance of quality control (QC) in order to reduce exposure and improve image quality by comparing the center-point (CP) of according to hospital grade and the difference between X-ray field (XF) and light field (LF) in diagnostic digital X-ray devices. XF and LF size, CP were measured in 12 digital X-ray devices at 10 hospitals located in 00 metropolitan cities. Phantom was made in different width respectively, using 0.8 mm wire after attaching to the standardized graph paper on transparent plastic plate and marked as cross wire in the center of the phantom. After placing the phantom on the table of the digital X-ray device, the images were obtained by shooting it vertically each field of survey. All images were acquired under the same conditions of exposure at distance of 100cm between the focus-detector. XF and LF size, CP error were measured using the picture archiving communication system. data were expressed as mean with standard error and then analyzed using SPSS ver. 22.0. The difference in field between the XF and LF size was the smallest in clinic, followed by university hospitals, hospitals and general hospitals. Based on the university hospitals with the least CP error, there was a statistically significant difference in CP error between university hospitals and clinics (p=0.024). Group less than 36-month after QC had fewer statistical errors than 36-month group (0.26 vs. 0.88, p=0.036). The difference between the XF and LF size was the lowest in clinic and CP error was the lowest in university hospital. Moreover, hospitals with short period of time after QC have fewer CP error and it means that introduction of timely QC according to the QC items is essential.

Analyze for the Quality Control of General X-ray Systems in Capital region (수도권지역 일반촬영 장비의 정도관리 분석)

  • Kang, Byung-Sam;Lee, Kang-Min;Shim, Woo-Yong;Park, Soon-Chul;Choi, Hak-Dong;Cho, Yong-Kwon
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.93-102
    • /
    • 2012
  • Thanks to the rapid increase of the interest in the quality control of the General X-ray systems, this research proposes the direction of the quality control through comparing and inspecting the actual condition of the respective quality control in the Clinic, the educational institution and the hospital. The subjects of the investigation are diagnostic radiation equipment's in the clinic, the educational institution and the hospital around the capital. A test of kVp, mR/mAs out put test and reproducibility of the exposure dose, half value layer, an accordance between the light field and the beam alignment test, and lastly reproducibility of the exposure time. Then the mean difference of the percentage, the CV (Coefficient of Variation, CV) and the attenuated curve which are respectively resulted from the above tests are computed. After that we have evaluated the values according to the regulations on the Diagnostic Radiation Equipment Safety Administration regulations. In the case of the clinic and the educational institution, there were 22 general X-ray devices. And 18.2% of the kVp test, 13.6% of the reproducibility of exposure dose test, 9.1% of the mR/mAs out put test, and 13.6% of the HVL (Half Value Layer) test appeared to be improper. In the case of the hospital, however, there were 28 devices. And 7.1% of the reproducibility of exposure dose, 7.1% of the difference in the light field/ beam alignment, and 7.1% of the reproducibility of the exposure time appeared to be improper. According to the investigation, the hospital's quality control condition is better than the condition in the clinic and the educational institution. The quality control condition of the general X-ray devices in the clinic is unsatisfactory compared to the hospital. Thus, it is considered that realizing the importance of the quality control is necessary.