• Title/Summary/Keyword: Radiology Clinic

Search Result 251, Processing Time 0.037 seconds

Evaluation of Cerebral Blood Flow Using Arterial Spin Labeling in Patients with Chronic Kidney Disease (만성 콩팥병 환자들에서 동맥 스핀 표지 기법을 이용한 뇌 관류상태의 평가)

  • Se Won Oh;Samel Park;Nam-jun Cho;Hyo-Wook Gil;Eun Young Lee;Hyung Geun Oh;Sung-Tae Park
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.4
    • /
    • pp.912-919
    • /
    • 2020
  • Purpose This study aimed to compare the brain perfusion status of patients with chronic kidney disease to a normal control group to identify any significant differences. Materials and Methods The perfusion state of the brain was measured by MRI using the arterial spin labeling technique in 36 patients undergoing hemodialysis due to chronic kidney disease and 36 normal controls. Images were then analyzed in a voxel-wise manner to detect brain areas showing significant perfusion differences between the two groups. Results Patients with chronic kidney disease showed increased perfusion in the form of large clusters across the right fronto-parieto-temporal lobe and the left parieto-occipital lobe. In addition, perfusion increased in the bilateral thalami, midbrain, pons, and cerebellum (p < 0.01, familywise error corrected). Conclusion Brain perfusion appears to increase in patients with chronic kidney disease compared to normal controls. Uremic toxicity is thought to be the cause of this increase as it can cause damage to the microscopic blood vessels and their surrounding structures.

Functional Magnetic Resonance Imaging and Diffusion Tensor Imaging for Language Mapping in Brain Tumor Surgery: Validation With Direct Cortical Stimulation and Cortico-Cortical Evoked Potential

  • Koung Mi Kang;Kyung Min Kim;In Seong Kim;Joo Hyun Kim;Ho Kang;So Young Ji;Yun-Sik Dho;Hyongmin Oh;Hee-Pyoung Park;Han Gil Seo;Sung-Min Kim;Seung Hong Choi;Chul-Kee Park
    • Korean Journal of Radiology
    • /
    • v.24 no.6
    • /
    • pp.553-563
    • /
    • 2023
  • Objective: Functional magnetic resonance imaging (fMRI) and diffusion tensor imaging-derived tractography (DTI-t) contribute to the localization of language areas, but their accuracy remains controversial. This study aimed to investigate the diagnostic performance of preoperative fMRI and DTI-t obtained with a simultaneous multi-slice technique using intraoperative direct cortical stimulation (DCS) or corticocortical evoked potential (CCEP) as reference standards. Materials and Methods: This prospective study included 26 patients (23-74 years; male:female, 13:13) with tumors in the vicinity of Broca's area who underwent preoperative fMRI and DTI-t. A site-by-site comparison between preoperative (fMRI and DTI-t) and intraoperative language mapping (DCS or CCEP) was performed for 226 cortical sites to calculate the sensitivity and specificity of fMRI and DTI-t for mapping Broca's areas. For sites with positive signals on fMRI or DTI-t, the true-positive rate (TPR) was calculated based on the concordance and discordance between fMRI and DTI-t. Results: Among 226 cortical sites, DCS was performed in 100 sites and CCEP was performed in 166 sites. The specificities of fMRI and DTI-t ranged from 72.4% (63/87) to 96.8% (122/126), respectively. The sensitivities of fMRI (except for verb generation) and DTI-t were 69.2% (9/13) to 92.3% (12/13) with DCS as the reference standard, and 40.0% (16/40) or lower with CCEP as the reference standard. For sites with preoperative fMRI or DTI-t positivity (n = 82), the TPR was high when fMRI and DTI-t were concordant (81.2% and 100% using DCS and CCEP, respectively, as the reference standards) and low when fMRI and DTI-t were discordant (≤ 24.2%). Conclusion: fMRI and DTI-t are sensitive and specific for mapping Broca's area compared with DCS and specific but insensitive compared with CCEP. A site with a positive signal on both fMRI and DTI-t represents a high probability of being an essential language area.

The Spread of Contrast Media in Celiac Plexus Block (복강신경총 차단시의 조영제 확산)

  • Lee, Jung-Koo;Chung, Jung-Kil;Lee, Sung-Moon
    • The Korean Journal of Pain
    • /
    • v.7 no.2
    • /
    • pp.211-216
    • /
    • 1994
  • Celiac plexus block is performed to relieve intractable upper abdominal cancer pain. Generally, celiac plexus blocks have been performed under control of X-ray fluoroscopy to determine the position of the needle tip and the spread of contrast media. During the period from March 1992 to February 1994, we have performed 21 cases of neurolytic celiac plexus block to alleviate pain of intra-abdominal malignancy. We retrospectively evaluated the location of the needle tip and the spread of contrast media. P-A views of simple abdomen demonstrated the locations of the needle tip: 66.7% of the left needle tips were in upper 3/1 of L1 (6 cases) and $T_{12}-L_1$ interspace (8 cases), 50% of the right needle tips were in upper 1/3 of $L_1$, (6 cases) and $T_{12}-L_1$ interspace (4 cases). Contrast media from the right needle spread upward to middle 1/3 of $T_{10}$ (5 cases) and middle 1/3 of $T_{11}$ (5 cases), downward to middle 1/3 of $L_1$ (6 cases) and lower 1/3 of $L_1$ (3 cases). Contrast media from the left needle were spread upward to middle 1/3 of $T_{10}$ (5 cases) and evenly to other spaces, downward to middle 1/3 of $L_1$, (4 cases) and $L_1-L_2$ interspace (6 cases). We analyze the spread of contrast media according to distance from needle tip by authors score system. Contrast media of right needle spread upward 6.1 and downward 3.4, that of left needle spread upward 6.5 and downward 3.7.

  • PDF

Morphological Changes in the Mandibular Condyle Following Botulinum Toxin Injection into the Human Masseter Muscle

  • Younjung Park;Junghoon Hong;Hyok Park;Naoya Kakimoto;Seong Taek Kim
    • Journal of Oral Medicine and Pain
    • /
    • v.48 no.1
    • /
    • pp.16-24
    • /
    • 2023
  • Purpose: To determine the effects of botulinum toxin (BoNT) injection into the human masseter muscle on the morphology of the mandibular condyle bone using cone-beam computed tomography (CBCT). Methods: Twenty volunteers were randomly assigned to one of two groups. Group I received a single BoNT injection; Group II received two injections, with the second being administered 4 months after the first. CBCT scans of both temporomandibular joints (TMJs) were performed before and 6 months after the first injection. Bony changes in the cortical layers of the condyle heads were evaluated and the long and short axes of both mandibular condyles were measured. The thickness at the thinnest part of glenoid fossa was also quantitatively measured. Results: There was no significant difference between pre- and post-injection CBCT images. Furthermore, no changes in the cortical layers of the condyle heads were observed among the subjects who exhibited mild degenerative TMJ changes. The quantitative measurements (long axis, short axis, and the thickness of thinnest part of glenoid fossa roof) did not differ significantly between pre- and post-injection except for the long axis in Group I. Conclusions: Within the limitations of this study, it appears that BoNT injections into human masseter muscles do not alter the morphology of the mandibular condyle bone in healthy adults.

Noise Changes in Image Plate (시간변화에 따른 영상판의 노이즈 변화)

  • Choi, Seokyoon;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.271-275
    • /
    • 2018
  • It is possible to do not use the Image Plate for a long time in the clinic. for the acquisition of reliable images the decommissioning process is very important. In this study, we would like to look at complex noises that may occur during Image Plate use depending on the frequency and time of day. first, we got the image from computer radiography. second, We calculate the noise changes using Peak Signal to Noise Ratio(PSNR) and Noise Power Spectrum(NPS). finally, we suggest that remove the noise from the IP for more than 4 hours. and It turned out to be better to remove the noise more than once. this study will be a quantitative reference for Image Plate management and use in the clinical trial.

The Cognition and Practice of Infection Control in Dental Workplace (근무지 유형에 따른 치과감염관리 인지도 및 실천도 조사)

  • Lee, YunHui;Choi, SungMi
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.6
    • /
    • pp.409-416
    • /
    • 2015
  • This study is to examine the infection management cognition and to practice of dental hygienists about their general characteristics, type of workplace. 354 dental hygienists in Daegu and Kyungbuk cities. The questionnaire survey was performed from April to May, 2015. These showed that factors of dental infection management according to workplace depended existence and nonexistence that chief of station and program of infection management, education of infection control(p<.001). Also cognition of dental infection control according to workplace drawed the protection individual(p<.05), asepsis procedure(p<.01), control of dental equipment(p<.001), control of infectious waste(p<.01) and laundry(p<.001), to practice of dental infection control according to workplace drawed the protection individual and asepsis procedure(p<.001), methods of disinfected and sterilized(p<.05), control of dental equipment and laundry(p<.001), control of infectious waste(p<.05). As above results, in order to minimize the infection prevention in the dental clinic, the regular infection control education for infection control of dental hygienists required, infection control guidelines place at the dental office.

Radiographic examination protocol and patient dose in lateral cephalometric radiography in Korea (국내 의료기관에서 측방두부규격방사선촬영시 임상에서의 촬영조건 및 환자 선량)

  • Choi, Jin-Woo
    • Imaging Science in Dentistry
    • /
    • v.40 no.4
    • /
    • pp.165-169
    • /
    • 2010
  • Purpose : To survey the radiographic examination protocol for lateral cephalometric radiographic examinations and to measure their patient doses in Korea and to compare the dose according to the size of hospital, the type of image receptor system, and the installation duration. Materials and Methods : The radiographic examination protocols (kVp, mA, and exposure time) for lateral cephalometric radiography were surveyed with 61 cephalometric radiographic equipments and their patient dose-area product (DAP) measured with a DAP meter (DIAMENTOR M4-KDK, PTW, Freiburg, Germany) for 51 cephalometric radiographic equipments. The radiographic examination protocols and patient doses were compared according to the size of hospital (university dental hospital, dental hospital, and dental clinic), the type of image receptor system (film-based, DR and CR type) and the installation duration, respectively. SPSS 12.0.1 for Windows (SPSS Inc., Chicago, USA) was used for independent t-test and ANOVA test. Results : The average protocols were 77.0 kVp, 12.7 mA, 6.2 second for cephalometric radiography. The average patient dose (DAP) was $128.0mGy\;cm^2$ and 3rd quartile dose (DAP) $161.1mGy\;cm^2$ for cephalometric radiography for adult male. There was no statistically significant difference at average patient DAP according to the size of hospital, the type of image receptor system, and the installation duration, repectively. Conclusion : The average patient dose was $128.0mGy\;cm^2$ and the third quartile patient dose $161.1mGy\;cm^2$ for lateral cephalometric radiography for adult male in Korea.

The change patterns of the Clustering of metabolic syndrome (대사증후군 구성요인의 군집별 변화 양상)

  • Kim, Young-Ran;Cheon, Hae-Kyung;Lee, Tae-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.526-537
    • /
    • 2016
  • Objective: This study examined the changes in the clustering of metabolic syndrome, and examined the distribution of a combination of clustering. Methods: The study was performed with the data from the same 1,900 people who had a medical checkup at a health clinic twice from 2009 to 2013. The subjects were divided into two groups of metabolic syndrome and non-metabolic syndrome (normal group) and examined according to the periodic changes. The related factors were examined with a cohort study. Results: The order affecting the prevalence of metabolic syndrome by the combination of metabolic syndrome constituent factors was two combinations (TG+HDL), three combinations (WC+TG+HDL), and four combination (WC+TG+HDL+BP). Conclusions: To manage these factors, public health programs will be needed and the methods to prevent metabolic syndrome should be promoted. In addition, more study on the risk factors of metabolic syndrome will be needed.

Produced Body Customized 3D Print Finger Brace using Dicom File (Dicom file을 이용하여 만든 신체 맞춤형 3D print 손가락 보조기 제작)

  • Choi, Hyeun-Woo;Park, Ji-Eun;Kim, Jung-Hun;Seo, An-Na;Lee, Jong-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.597-603
    • /
    • 2019
  • We obtained a Dicom file using a CT (Computed Tomography), a diagnostic test device used in clinical practice. Dicom files and 3D programs, and finger printers with 3D printers. Because the finger brace is intended for the human body, the accuracy of the shape is very important. 3D Print has the advantage of high precision, variety of materials, and short output time. In clinic, aluminum protector or medical device manufacturer's finger protector is limited. By creating a finger brace with a 3D printer, we expect to be able to apply a precise form of a custom finger brace to the patient that can be used to treat a patient's finger trauma, illness, or deformity.

Efficient Determination of Iteration Number for Algebraic Reconstruction Technique in CT (CT의 대수적재구성기법에서 효율적인 반복 횟수 결정)

  • Joon-Min, Gil;Kwon Su, Chon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.141-148
    • /
    • 2023
  • The algebraic reconstruction technique is one of the reconstruction methods in CT and shows good image quality against noise-dominant conditions. The number of iteration is one of the key factors determining the execution time for the algebraic reconstruction technique. However, there are some rules for determining the number of iterations that result in more than a few hundred iterations. Thus, the rules are difficult to apply in practice. In this study, we proposed a method to determine the number of iterations for practical applications. The reconstructed image quality shows slow convergence as the number of iterations increases. Image quality 𝜖 < 0.001 was used to determine the optimal number of iteration. The Shepp-Logan head phantom was used to obtain noise-free projection and projections with noise for 360, 720, and 1440 views were obtained using Geant4 Monte Carlo simulation that has the same geometry dimension as a clinic CT system. Images reconstructed by around 10 iterations within the stop condition showed good quality. The method for determining the iteration number is an efficient way of replacing the best image-quality-based method, which brings over a few hundred iterations.