• Title/Summary/Keyword: Radiological measurement

검색결과 616건 처리시간 0.022초

A New Method for Measuring the Dose Distribution of the Radiotherapy Domain using the IP

  • Homma, Mitsuhiko;Tabushi, Katsuyoshi;Obata, Yasunori;Tamiya, Tadashi;Koyama, Shuji;Kurooka, Masahiko;Shimomura, Kouhei;Ishigaki, Takeo
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.237-240
    • /
    • 2002
  • Knowing the dose distribution in a tissue is as important as being able to measure exposure or absorbed dose in radiotherapy. Since the Dry Imager spread, the wet type automatic processor is no longer used. Furthermore, the waste fluid after film development process brings about a serious problem for prevention of pollution. Therefore, we have developed a measurement method for the dose distribution (CR dosimetry) in the phantom based on the imaging plate (IP) of the computed radiography (CR). The IP was applied for the dose measurement as a dosimeter instead of the film used for film dosimetry. The data from the irradiated IP were processed by a personal computer with 10 bits and were depicted as absorbed dose distributions in the phantom. The image of the dose distribution was obtained from the CR system using the DICOM form. The CR dosimetry is an application of CR system currently employed in medical examinations to dosimetry in radiotherapy. A dose distribution can be easily shown by the Dose Distribution Depiction System we developed this time. Moreover, the measurement method is simpler and a result is obtained more quickly compared with film dosimetry.

  • PDF

종골의 사체 실측 결과와 방사선학적 측정 결과의 비교 (Comparison of the Results between Cadaveric and Radiological Measurements of Calcaneus)

  • 김정한;곽희철;이창락;정동우;노상명
    • 대한족부족관절학회지
    • /
    • 제19권3호
    • /
    • pp.102-106
    • /
    • 2015
  • Purpose: We wanted to compare the results between cadaveric and radiological measurements of calcaneus. Materials and Methods: Sixty three calcaneus of 33 cadavers donated between December 2012 and December 2014 were actually measured. Computed tomography (CT) images of 244 calcaneus in 122 patients of the same age group with cadavers were radiologically measured. Maximum length, maximum width, maximum height, $B{\ddot{o}}hler$ angle, Gissane angle, Fowler-Phillip angle, and tala-articular angle were measured. Results: In cadaveric measurement, the mean maximal height, length, and width were $41.8{\pm}3.3mm$, $73.3{\pm}3.4mm$, and $40.7{\pm}2.2mm$, respectively. In radiological measurement, the mean maximal height, length, and width were $38.5{\pm}4.3mm$, $74.0{\pm}5.7mm$, and $44.7{\pm}1.4mm$, respectively. In cadaveric measurement, the mean $B\ddot{o}hler$ angle, Gissane angle, Fowler-Phillip angle, and tala-articular angle were $32.1^{\circ}{\pm}6.2^{\circ}$, $110.8^{\circ}{\pm}8.1^{\circ}$, $55.8^{\circ}{\pm}6.8^{\circ}$, and $59.7^{\circ}{\pm}4.6^{\circ}$, respectively. In radiological measurement the mean $B{\ddot{o}}hler$ angle, Gissane angle, Fowler-Phillip angle, and tala-articular angle were $32.6^{\circ}{\pm}3.8^{\circ}$, $113.7^{\circ}{\pm}5.7^{\circ}$, $62.2^{\circ}{\pm}3.9^{\circ}$, and $61.6^{\circ}{\pm}6.3^{\circ}$, respectively. The mean maximal height was significantly higher in the cadaveric measurement group (p<0.001) and the mean maximal length and width were significantly higher in the radiologic measurement group (p<0.001, p<0.001). The mean Gissane angle, Fowler-Philip angle, and $B{\ddot{o}}hler$ angle were significantly higher in the CT group (p=0.001, p<0.001, p=0.016, respectively). There was no significant difference in the mean tala-articular angle (p=0.352). Conclusion: Significant differences in length parameters were observed between the cadaveric measurement group and the radiologic measurement group. However, no significant differences in angular measurements were observed between the two groups. The authors carefully conclude that radiological measurement values may be different from actual values in the calcaneus.

척추측만증 평가 척도에 관한 문헌 고찰: 비방사선 방법을 중심으로 (Review Study on the Measurement Tools of Scoliosis: Mainly on Non-radiological Methods)

  • 김동주;최성경;조효림;하유빈;최성환;박서현;이승덕;금동호;성원석;김은정
    • 대한한의학회지
    • /
    • 제42권1호
    • /
    • pp.75-98
    • /
    • 2021
  • Objectives: The purpose of this study is to investigate the characteristics, validity, and reliability of non-radiological assessment tools of scoliosis that have been studied so far. Methods: Electronic databases including Pubmed, Cochrane Library, CNKI, Science On, RISS, OASIS were searched by keywords including 'scoliosis assessment', 'scoliosis screening', 'physical examination', 'functional measurement', 'photography', and 'smartphone'. Results: 32 articles using radiation-free assessments were identified from 1,011 records. The mostly used non-radiological methods were Surface topography, Scoliometer, Ultrasound, Digital Infrared Thermal Imaging, and Photography. The other methods were Gait analysis, 3D depth sensor imaging, and Low intensity electromagnetic scan. Conclusions: It was found that non-radiological assessment tools might reduce the number of radiographs taken in scoliosis patients. To increase the reliability and validity, further research on the measurement tools of scoliosis will be needed.

의료용 선형가속기 출력측정용 듀얼윈도우 팬텀 개발 (Development of Dual-Window Phantom for Output Measurement of Medical Linacs)

  • 정동혁;곽동원;문영민;강영록;김정기;이만우
    • 한국의학물리학회지:의학물리
    • /
    • 제23권4호
    • /
    • pp.229-233
    • /
    • 2012
  • 광자선 출력측정시 업무 효율을 높이기 위한 소형 물팬톰(듀얼윈도우 팬톰)을 개발하였다. 이 팬톰은 고에너지 광자선의 출력측정뿐만아니라 선질지표의 결정에 적합하다. 이 팬톰은 두개의 창을 가지고 있으며 독립된 두 축에 의해 회전할 수 있도록 제작되어있다. 이 때 두 축은 전리함 이동 없이 조직팬톰선량비와 깊이선량율비를 결정하기 위한 것이다. 코발트조사기와 선형가속기의 고에너지 광자선을 이용하여 팬톰을 평가하였으며, 기준값과 비교할 때 Co-60의 경우 0.2% 그리고 가속기 x-선에 대해 1.4% 이내로 일치하였다. 이 팬톰은 발생 가능한 인적오차를 방지할 수 있기 때문에 일상의 출력측정에 매우 실용적이라고 본다.

방사선사의 직무 스트레스 측정도구 개발을 위한 요인별 신뢰도 분석 (An Analysis of Reliability by Factors for Development of Job Stress Measurement Tools of Radiological Technologists)

  • 정홍량;손부순;임청환
    • 한국환경보건학회지
    • /
    • 제32권2호
    • /
    • pp.103-110
    • /
    • 2006
  • The present study is designed to analyze reliability and validity of the instruments used to measure job stress of radiological technologists mainly by means of the questionnaires from 'Korean edition of NIOSH check list'. The subjects of this study are 890 radiological technologists active at 44 general hospitals in 16 provinces and cities across the country. The item-total reliability revealed that 10 factors in 6 are the major causes of stress in job life of radiological technologists. The measuring instrument proved to be valid with reliability coefficient of internal consistency by factors being more than 0.7. The factors found to be applicable herewith include limit and authority of job (0.73), cohesion within departments (0.86), resources control (0.81), mental requirements (0.85), job load (0.82), and job stability (0.72). When job autonomy item of causes are modified for proper use to radiological technologists, the measuring instruments are expected to show high reliability. It seems, however, necessary to develop a measuring instrument to analyze and use the validity of related measuring instruments since the reliability here was rated low, with statistical coefficients lower than 0.7 in such factors as job management (0.57), conflicts within departments (-1.13), sense of responsibility for patients (0.66) and usage of education (0.26). As this study was intended to examine reliability and validity of the concepts related to measurement of job stress on the part of radiological technologists, it nay not be proper to apply the results of this study to general use, but is advised to utilize them as basis for developing instruments to verify reliability and validity by comparing with and analyzing other measuring instruments.

담배연기와 담뱃잎 내 함유된 방사능 농도분석 및 위해도 평가 (Analysis of Radioactivity Concentrations in Cigarette Smoke and Tobacco Risk Assessment)

  • 이세령;이상복;김정윤;김지민;방예진;이두석;조형준;김성철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권5호
    • /
    • pp.489-494
    • /
    • 2021
  • In this study, radioactivity quantitative analysis was performed on radon contained in cigarette, and the effective dose was calculated using the result value to determine the amount of exposure caused by smoking. A total of 5 types of cigarettes were sampled. Cigarette smoke was collected by using activated carbon, and tobacco were measured by homogenizing for quantitative analysis. For each sample, Bi-214 and Pb-214 were subjected to gamma nuclide analysis to observe the uranium-based radioactive material contained in cigarette, and a measurement time of 30,000 seconds was set for the sample based on the results of previous studies. As a result of measuring the radioactivity of tobacco, a maximum of 0.715 Bq/kg was derived, and in the case of cigarette smoke measured using activated carbon, a maximum of 3.652 Bq/kg was derived. Using this measurement, the average effective dose to the lungs is 0.938 mSv/y, and it was found that there is a possibility of receiving exposure up to 1.099 mSv/y depending on the type of tobacco. It was found that the exposure dose due to cigarette occupies a large proportion of the annual effective dose limit for the general public. Therefore, more diverse studies on radioactive substances in cigarette are needed, and measures to monitor and reduce the incidental exposure to radon should be established.