• Title/Summary/Keyword: Radiological characteristics

Search Result 666, Processing Time 0.024 seconds

Gamma Knife Surgery for Brain Metastasis from Renal Cell Carcinoma : Relationship Between Radiological Characteristics and Initial Tumor Response

  • Kim, Jin-Wook;Han, Jung-Ho;Park, Chul-Kee;Chung, Hyun-Tai;Paek, Sun-Ha;Kim, Dong-Gyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.2
    • /
    • pp.92-96
    • /
    • 2007
  • Objective : The authors have speculated that metastatic brain lesions from renal cell carcinoma (RCC) show diverse radiological patterns and tumor responses after Gamma knife surgery (GKS), and have hypothesized that these can be predicted from tumor radiological characteristics. The goal of the current study was to identify the radiological characteristics of RCC brain metastases and the predictors of initial radiosurgical response after GKS. Methods : A retrospective analysis was performed on 48 lesions in 18 patients with RCC brain metastasis treated by GKS. The radiological characteristics of these lesions in magnetic resonance images (MRI) were classified into 3 categories according to enhancement patterns in T1-weighted images and signal intensity characteristics in T2-weighted images. Responses to GKS were analyzed according to these categories, and in addition, other potential predictive factors were also evaluated. Results : MRI findings in the three categories were diverse, though numbers of the lesion were comparable. At 2-month MRI follow-ups after GKS, response rate was 54% and the local tumor control rate 83%. T2 signal intensity was found to be the principal predictive factor of response to GKS, namely negative predictive factor. Other variables such as age, sex, tumor volume, dose, duration from initial diagnosis to GKS, and previous systemic therapies failed to show significant relationships with treatment response by multivariate analysis. Conclusion : Careful evaluation of the radiological characteristics of brain metastases from RCC is important prior to GKS because MRI heterogeneity has predictive value in terms of determining initial tumor response.

Comparison of Polymer and BANGTM Gel Dosimeters to Use a Optical Computed Tomography Scanner (광학 전산화단층촬영 스캐너 사용을 위한 중합체 겔과 BANGTM 겔 선량계의 특성 비교)

  • Kyung Hwan Chang
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.107-114
    • /
    • 2023
  • The purpose of this study was to compare the basic radiological characteristics of in-house polymer gel and commercially-available gel (BANGTM) gel dosimeters with a spectro-photometer to use a optical computed tomography (CT) scanner. We investigated the radiological characteristics including dose linearity, absorbance spectrum, dose rate dependency and inter-and intra-reproducibility at wavelengths of 590, 600 and 630 nm. The optimal dose linearities of two gel dosimeters showed R2 value of 0.939 and 0.948 at wavelengths of 590 nm and 600 nm, respectively. For two polymer gel dosimeters, there is no peak sensitivity within the range of all wavelengths in absorbance spectrum. For in-house gel dosimeter, the dose rate dependency were within 5% for all wavelengths except for the dose rate of 100 MU/min. For BANGTM gel dosimeter, the dose rate dependency showed an error range of ±5% for all wavelengths. The inter-and intra-reproducibility of two gel dosimeters were within the range of 2.5%. We have confirmed that the two gel dosimeters was appropriate for use with a optical CT scanner.

Comparison of Demographic and Job Characteristics with Job Satisfaction between Sonographers and Radiological Technologists (초음파사와 방사선사의 인구학적 및 직무 특성과 직무 만족도의 비교분석)

  • Kim, Hye-Jin;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.389-397
    • /
    • 2021
  • The purpose of this study was to compare the demographic and job characteristics and job satisfaction of sonographers (SONO) and radiological technologists (RT). The subjects were a total of 148 people (69 SONO, 79 RT), who had been working in clinical and hospitals. The method was conducted using a questionnaire with a total of 54 questions consisting of demographic characteristics, job characteristics, and job satisfaction. Reliability was secured with Cronbach's alpha coefficient of 0.6 or higher for the response of the questionnaire. For statistical analysis, descriptive statistics, cross-analysis, independent sample T-test, and correlation analysis using Pearson's correlation coefficient and Spearman's correlation coefficient were performed for each occupation. As a result, first, the SONO had more female workers than RT. They are more than three times as many in graduate school and above. Second, the SONO had 4.5 times more morning shift than the RT and no form of weekend shift. Third, the average monthly salary of the SONO is higher than that of the RT, but when a certain portion of the salary goes up, the salary no longer goes up. Fourth, satisfaction with expectations, growth desire, positive mentality, growth opportunity, job importance, organizational attachment was higher SONO than the RT, but self-efficacy was higher in RT than SONO. Last, SONO had higher educational background than RT. It is hoped that the results of this study will be able to understand the job characteristics of SONO and RT and identify the factors of job satisfaction and provide them as fundamental materials for job selection.

Analysis of the Necessity of Medical Records Related to Radiological Examination (방사선검사의 의무기록에 관한 요구도 분석)

  • Hong, Dong-Hee;Lim, Cheong-Hwan;Lim, Woo-Taek;Joo, Young-Cheol;Jung, Hong-Ryang;Kim, Eun-Hye;Yoon, Yong-Su;Jung, Young-Jin;Choi, Ji-Won;Jeong, Sung-Hun;Park, Myeong-Hwan;Yang, Oh-Nam;Jeong, Bong-Jae
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.513-523
    • /
    • 2021
  • The purpose of this study was to discuss the required items and feasibility of medical records of radiological examinations performed by radiological technologists at medical institutions. An online survey was conducted to a total of 10,000 radiation-related workers, of which 1,026 (10.3%) responded. As a research method, self-made questionnaires were used. The online survey was conducted from September 10 to September 20, 2021 for the survey period. For response data, a Chi-square test was performed according to demographic characteristics using SPSS 27.0 version (IBM Inc., Chicago, Ill, USA), and it was judged to be significant when the P value was less than 0.05. The reliability of the questionnaire response was found to be Chronbach α=0.933. More than 90% of the medical records related to radiological examinations are necessary, and they answered that a curriculum, remuneration curriculum, and legal system for medical records should be prepared. More than 90% of the respondents agreed with the proposal of the Radiological Technologist Independent Act for legal preparation, and most of the information required for medical records is currently recorded in DICOM images. According to the demographic characteristics, the medical record requirement for radiological examination, curriculum, continuing education, and legislation were found to be higher with higher education and higher with longer working experience. In addition, most of the radiology departments showed a high demand for medical records, so most of them responded positively to the medical records requirements for radiological examinations. This study analyzed the medical record requirements for radiological examinations, and as shown in the results, medical record requirements for radiological examinations was found that most radiological technologists felt need for the new law and supported it. In addition, if the information recorded in the DICOM image is used, it is considered that medical records could be easily prepared without additional work by the radiological technologists.

Evaluation of Noise Power Spectrum Characteristics by Using Magnetic Resonance Imaging 3.0T (3.0T 자기공명영상을 이용한 잡음전력스펙트럼 특성 평가)

  • Min, Jung-Whan;Jeong, Hoi-Woun;Kim, Seung-Chul
    • Journal of radiological science and technology
    • /
    • v.44 no.1
    • /
    • pp.31-37
    • /
    • 2021
  • This study aim of quantitative assessment of Noise Power Spectrum(NPS) and image characteristics of by acquired the optimal image for noise characteristics and quality assurance by using magnetic resonance imaging(MRI). MRI device was (MAGNETOM Vida 3.0T MRI; Siemense healthcare system; Germany) used and the head/neck shim MR receive coil were 20 channels coil and a diameter 200 mm hemisphere phantom. Frequency signal could be acquired the K-space trajectory image and white image for NPS. The T2 image highest quantitatively value for NPS finding of showed the best value of 0.026 based on the T2 frequency of 1.0 mm-1. The NPS acquired of showed that the T1 CE turbo image was 0.077, the T1 CE Conca2 turbo image was 0.056, T1 turbo image was 0.061, and the T1 Conca2 turbo image was 0.066. The assessment of NPS image characteristics of this study were to that could be used efficiently of the MRI and to present the quantitative evaluation methods and image noise characteristics of 3.0T MRI.

Analysis of Job Characteristics for Ultrasound Examination of Radiological Technologists in Yeongnam Area (영남지역 방사선사의 초음파검사 직무특성 분석)

  • Jeong, Bong-Jae;Lee, Sang-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.639-647
    • /
    • 2022
  • This study analyzed the job characteristics of radiological technologists in charge of ultrasound examinations in the Yeongnam region. The measuring tool used in the study was a questionnaire, and the subjects were radiological technologists in charge of ultrasound examination at medical institutions located in the Yeongnam region from August 01 to November 30, 2021. In consideration of the COVID-19 situation, statistical analysis was performed using the SPSS/PC Ver 18.0 program using e-mail and SNS in a non-face-to-face manner with 158 questionnaires. As a result of analyzing the job characteristics of the radiological technologists in charge of ultrasound examination, the job satisfaction was 3.24±0.61. In the effect of job characteristic factors on job satisfaction, professional position, self-esteem, and trust relationship formation were found to be higher than the average of 3.0. However, as the dissatisfaction factor, compensation and appropriateness of work were cited. Therefore, in order to improve the job characteristics and satisfaction level of radiological technologists in charge of ultrasound examinations, it is necessary to do their best to improve the appropriate work environment of medical institutions and to continuously secure professionalism of radiological technologists in charge of ultrasound examinations.

Study on the Resolution Characteristics by Using Magnetic Resonance Imaging 3.0T (3.0T 자기공명영상을 이용한 해상력 특성에 대한 연구)

  • Min, Jung-Whan;Jeong, Hoi-Woun;Han, Ji-Hyun;Lee, Si-Nae;Han, Song-Yi;Kim, Ki-Won;Kim, Hyun-Soo;Son, Jin-Hyun
    • Journal of radiological science and technology
    • /
    • v.43 no.4
    • /
    • pp.251-257
    • /
    • 2020
  • This study was purpose to quantitative evaluation of edge method of modulation transfer function(MTF) and physical image characteristics of by obtain the optimal edge image by using magnetic resonance imaging(MRI). The MRI equipment was used (MAGNETOM Vida 3.0T MRI, Siemense healthcare system, Germany) and the head/neck matrix shim MR coil were 20 channels(elements) receive coil. The MTF results of showed the best value of 0.294 based on the T2 Nyquist frequency of 1.0 mm-1. The MTF results of showed that the T1 image is 0.160, the T1 CE image is 0.250, T1 Conca2 image is 0.043, and the T1 CE (Concatenation) Conca2 image is 0.190. The T2 image highest quantitatively value for MTF. The physical image characteristics of this study were to that can be used efficiently of the MRI and to present the quantitative evaluation method and physical image characteristics of 3.0T MRI.

A Study on Property of Microstructuree for Ba System of Perovskite Structure (페로브스카이형 Ba계열의 미세구조 특성)

  • Song, Min-Jong;Dong, Kyung-Rae;Kim, Chang-Bok;Choi, Seong-Kwan;Park, Yong-Soon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.4
    • /
    • pp.185-189
    • /
    • 2011
  • To assess the prevalence of various radiological reduction methods for childhood intussusception in training hospitals by means of a nationwide phone survey, and to demonstrate recent trends in this area by comparing the findings with those obtained in a survey conducted. $BaTiO_3$ system was prepared by using fabrication of classical conditioning ceramics. Polycrystalline and surface structure characteristics of the specimens were measured by X-ray diffraction, SEM(Scanning Electron Microscopy) and EDAX (Energy Dispersive Spectrometer), respectively.

  • PDF