• Title/Summary/Keyword: Radiological Engineering

Search Result 759, Processing Time 0.023 seconds

The Development of Automatic Chemical Processing System for $^{67}Ga$ Production ($^{67}Ga$ 생산용 화학처리 자동화 장치 개발)

  • Lee, Dong-Hoon;Kim, Yoon-Jong;Suh, Yong-Sup;Yang, Seung-Dae;Chun, Kwon-Soo;Hur, Min-Goo;Yun, Yong-Ki;Hong, Seung-Hong
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.1
    • /
    • pp.25-33
    • /
    • 2003
  • The automatic system for $^{67}Ga$ production using for the diagnosis of malignant tumor has been developed. A solvent extraction and an ion exchange chromatography were used for the separation $^{67}Ga$ from the irradiated enriched $^{68}Zn$. This system consisted of a solvent separation unit which was composed of micro conductivity cells, air supply tubes, solvent transfer tubes, solenoid valves and glasses, a PLC based controller and a PMU user interface unit for automation. The radiation exposure to the workers and the production time can both be reduced by employing this system during the $^{67}Ga$ production phase. After all, the mass production of $^{67}Ga$ with high efficiency was possible.

Inhibition of Telomerase Activity in U937 Human Monocytic Leukemia Cells by Compound K, a Ginseng Saponin Metabolite

  • Kang Kyoung-Ah;Lee Kyoung-Hwa;Chae Sung-Wook;Kim Jeong-Ki;Seo Jung-Yeon;Ham Yong-Ho;Lee Kee-Ho;Kim Bum-Joon;Kim Hee-Sun;Kim Dong-Hyun;Hyun Jin Won
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.1
    • /
    • pp.7-12
    • /
    • 2006
  • Telomerase activation is detected in most cancerous cells; hence, telomerase is a highly selective target for cancer therapy, which plays an important role in the apoptotic process. We have previously reported that the ginseng saponin metabolite, Compound K (20-O-D-glucopyranosyl-20(S)-protopanaxadiol, IH901), inhibits cell proliferation by inducing apoptosis and cell cycle arrest at the $G_1$ phase. The present study investigated the regulation of telomerase activity in Compound K treated U937 cells. Compound K treatment caused a reduction in telomerase activity and down-regulated the human telomerase reverse transcriptase (hTERT) gene, resulting in the decreased expressions of its protein, and of the c-Myc and Spl proteins (transcription factors of hTERT). These results indicate that the anticancer activity of Compound K could be mediated by inhibition of the telomerase activity.

Performance Comparison of Bed-type and Stand-type Commercial Whole Body Counter Made by Canberra for Internal Exposure Monitoring (Bed-type과 Stand-type 상용 전신계수기(Whole Body Counter)의 성능 비교)

  • Kim, Bong-Gi;Ha, Wi-ho;Kwon, Tae-Eun;Park, Min-Seok;Lee, Jun-Ho;Kim, Jong-Min;Lee, Sang-Gyung;Jung, Kyu-Hwan
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.437-444
    • /
    • 2018
  • Whole-Body counters have been used to evaluate the internal contamination of gamma emitting radionuclides. Among the whole-body counters used in domestic nuclear facilities, Fastscan made by CANBERRA contains 2 NaI(Tl) detectors and is generally used to monitor the primary internal exposure. It has the advantage of achieving MDA even with short time measurements. Accuscan is a bed type, and has good energy resolution because it is composed of HPGe detector. Since the Accuscan with better energy resolution than Fastscan has better able to identify radionuclides, it is used to monitor secondary internal exposure. Some nuclear facilities have only Fastscan. We analyzed statistically whether Fastscan is enough to ensure accuracy and precision comparing with Accuscan. To do this, we prepared a CRM created by the Korea Research Institute of Standards and Science. We also obtained the data of 6 Fastscans and 5 Accuscans in domestic nuclear facilities. As a result of the study, although Fastscan compared with Accuscan is not as accurate as the Accuscan, the precision is statistically same. However, accuracy of Fastscan is in compliance with international standards except low energy range. In terms of accuracy and precision except radionuclides emitting low energy, it is possible to measure radioactivity inside workers even in nuclear facilities where only Fastscan is used.

Measurement of Neutron Production Double-differential Cross-sections on Carbon Bombarded with 430 MeV/Nucleon Carbon Ions

  • Itashiki, Yutaro;Imahayashi, Youichi;Shigyo, Nobuhiro;Uozumi, Yusuke;Satoh, Daiki;Kajimoto, Tsuyoshi;Sanami, Toshiya;Koba, Yusuke;Matsufuji, Naruhiro
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.344-349
    • /
    • 2016
  • Background: Carbon ion therapy has achieved satisfactory results. However, patients have a risk to get a secondary cancer. In order to estimate the risk, it is essential to understand particle transportation and nuclear reactions in the patient's body. The particle transport Monte Carlo simulation code is a useful tool to understand them. Since the code validation for heavy ion incident reactions is not enough, the experimental data of the elementary reaction processes are needed. Materials and Methods: We measured neutron production double-differential cross-sections (DDXs) on a carbon bombarded with 430 MeV/nucleon carbon beam at PH2 beam line of HIMAC facility in NIRS. Neutrons produced in the target were measured with NE213 liquid organic scintillators located at six angles of 15, 30, 45, 60, 75, and $90^{\circ}$. Results and Discussion: Neutron production double-differential cross-sections for carbon bombarded with 430 MeV/nucleon carbon ions were measured by the time-of-flight method with NE213 liquid organic scintillators at six angles of 15, 30, 45, 60, 75, and $90^{\circ}$. The cross sections were obtained from 1 MeV to several hundred MeV. The experimental data were compared with calculated results obtained by Monte Carlo simulation codes PHITS, Geant4, and FLUKA. Conclusion: PHITS was able to reproduce neutron production for elementary processes of carbon-carbon reaction precisely the best of three codes.

Postal Dosimetry Audits for the Domestic Medical Linear Accelerator

  • Kim, Kum Bae;Choi, Sang Hyoun
    • Progress in Medical Physics
    • /
    • v.31 no.2
    • /
    • pp.20-28
    • /
    • 2020
  • Purpose: The objective of this study is to perform Postal dosimetry audits for medical linear accelerators in radiation therapy institutions using glass dosimeters and Gafchromic film reading systems and postal dosimetry audit procedures, and to evaluate radiation therapy doses and mechanical accuracy in medical institutions. Methods: Photon output measured and analyzed using a standard phantom for measuring photon output dose using a glass dosimeter for medical linear accelerators. Mechanical accuracy was measured and analyzed using software for film measurement. Results: Measurement and analysis of photon beam output dose using a standard phantom glass dosimeter for photon beam output dose measurement was completed. All tolerance doses were within 5%. Mechanical accuracy measurement and analysis using a standard phantom for verifying the mechanical accuracy of linear accelerator (LINAC) using a Gafchromic film were completed, and all results were shown within tolerances (2 mm or less). Conclusions: In this study, Postal dosimetry audits were performed on the output dose and mechanical accuracy of photon beams (207 beams) for 106 LINACs from 48 institutions. As a result of corrective action and re-execution, it was confirmed that all engines met the acceptable standard within 2 mm in the linear accelerator.

Application of the new ICRP iodine biokinetic model for internal dosimetry in case of thyroid blocking

  • Kwon, Tae-Eun;Chung, Yoonsun;Ha, Wi-Ho;Jin, Young Woo
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1826-1833
    • /
    • 2020
  • Administration of stable iodine has been considered a best measure to protect the thyroid from internal irradiation by radioiodine intake, and its efficacy on thyroid protection has been quantitatively evaluated in several simulation studies on the basis of simple iodine biokinetic models (i.e., three-compartment model). However, the new iodine biokinetic model adopted by the International Commission on Radiological Protection interprets and expresses the thyroid blocking phenomenon differently. Therefore, in this study, the new model was analyzed in terms of thyroid blocking and implemented to reassess the protective effects and to produce dosimetric data. The biokinetic model calculation was performed using computation modules developed by authors, and the results were compared with those of experimental data and prior simulation studies. The new model predicted protective effects that were generally consistent with those of experimental data, except for those in the range of stable iodine administration -72 h before radioiodine exposure. Additionally, the dosimetric data calculated in this study demonstrates a critical limitation of the three-compartment model in predicting bioassay functions, and indicated that dose assessment 1 d after exposure would result in a similar dose estimate irrespective of the administration time of stable iodine.

Sensitivity Analysis on the Priority Order of the Radiological Worker Allocation Model using Goal Programming

  • Jung, Hai-Yong;Lee, Kun-Jai
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.577-582
    • /
    • 1998
  • In nuclear power plant, it has been the important object to reduce the occupational radiation exposure (ORE). Recently, the optimization concept of management science has been studied to reduce the ORE in nuclear power plant. In optimization of the worker allocation, the collective dose, working time, individual dose, an total number of worker must be considered and their priority orders must be thought because the main constraint is necessary for determining the constraints variable of the radiological worker allocation problem. The ultimate object of this study s to look into the change of the optimal allocation of the radiological worker as priority order changes. In this study, the priority order is the characteristic of goal programming that is a kind of multi-objective linear programming. From a result of study using goal programming, the total number of worker and collective dose of worker have changed as the priority order has changed and the collective dose limit have played an important role in reducing the ORE.

  • PDF

SNR and PSNR measurements and analysis of median filtering for the removal of impulse noise from CR imaging

  • Hong, Seong-Il;Dong, Kyung-Rae;Ryu, Young-Hwan
    • International Journal of Contents
    • /
    • v.5 no.4
    • /
    • pp.7-12
    • /
    • 2009
  • In this paper, the authors showed that the removal of impulse noise in CR images was implemented using variety of median filters and SNR/PSNR measurements. They used three kinds of medical images-hand, skull, and knee- for experimental results. But the noise in CR image was only the impulse noise. In real medical image, the noise of an image would be very different type. Therefore. the lack of experimental results using different noise in CR images is one flaw.

State-of-the-art and challenges of non-destructive techniques for in-situ radiological characterization of nuclear facilities to be dismantled

  • Amgarou, Khalil;Herranz, Margarita
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3491-3504
    • /
    • 2021
  • This paper reports on the state-of-the-art of the main non-destructive assay (NDA) techniques usually used for in-situ radiological characterization of nuclear facilities subject to a decommissioning programme. For the sake of clarity and coherence, they have been classified as environmental radiation monitoring, surface contamination measurements, gamma spectrometry, passive neutron counting and radiation cameras. Particular mention is also made here to the various challenges that each of these techniques must currently overcome, together with the formulation of some proposals for a potential evolution in the future.