• Title/Summary/Keyword: Radiological Effects

Search Result 588, Processing Time 0.034 seconds

Feasibility of Reflecting Improvement of Tumor Hypoxia by Mild Hyperthermia in Experimental Mouse Tumors with $^18F-Fluoromisonidazole$ (저온온열치료에 의한 종양 내 저산소상태 개선효과를 $^18F$-Fluoromisonidazole의 섭취 변화를 이용한 평가)

  • Lee Sang-wook;Ryu Jin Sook;Oh Seung Joon;Im Ki Chun;Chen Gi Jeong;Lee So Ryung;Song Do Young;Im Soo Jeong;Moon Eun Sook;Kim Jong Hoon;Ahn Seung Do;Shin Seong Soo;Lee Kyeong Ryong
    • Radiation Oncology Journal
    • /
    • v.22 no.4
    • /
    • pp.288-297
    • /
    • 2004
  • Puporse: The aims of this study were to evaluate the change of $[^18F]fluoromisonidazole$($[^18F]FMISO$) uptake in C3H mouse squamous cell carcinoma-VII (SCC-VII) treated with mild hyperthermia ($42^{circ}C$) and nicotinamide and to assess the biodistribution of the markers in normal tissues under similar conditions. Methods and Materials: $[^18F]FMISO$ was producedby our hospital. Female C3H mice with a C3H SCC-VII tumor grown on their extremities were used. Tumors were size matched. Non-anaesthetized, tumor-bearing mice underwent control or mild hyperthermia at $42^{circ}C$ for 60 min with nicotinamide (50 mg/kg i.p. injected) and were examined by gamma counter, autoradiography and animal PET scan 3 hours after tracer i.v. injected with breathing room air, The biodistribution of these agents were obtained at 3 h after $[^18F]FMISO$ injection. Blood, tumor, muscle, heart, lung, liver, kidney, brain, bone, spleen, and intestine were removed, counted for radioactivity and weighed. The tumor and liver were frozen and cut with a cryomicrotome into 10- um sections. The spatial distribution of radioactivity from the tissue sections was determined with digital autoradiography. Results: The mild hyperthermia with nicotinamide treatment had only slight effects on the biodistribution of either marker in normal tissues. We observed that the whole tumor radioactivity uptake ratios were higher in the control mice than in the mild hyperthermia with nicotinamide treated mice for $[^18F]FMISO$ ($1.56{\pm}1.03$ vs. $0.67{\pm}0.30$; p=0.063). In addition, autoradiography and animal PET scan demonstrated that the area and intensity of $[^18F]FMISO$ uptake was significantly decreased. Conclusion: Mild hyperthermla and nicotinamide significantly improved tumor hypoxia using $[^18F]FMISO$ and this uptake reflected tumor hypoxic status.

Optimization of Protocol for Injection of Iodinated Contrast Medium in Pediatric Thoracic CT Examination (소아 흉부 CT검사에서 조영제 주입에 관한 프로토콜의 최적화)

  • Kim, Yung-Kyoon;Kim, Yon-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.879-887
    • /
    • 2019
  • The purpose of this study is to establish a physiological injection protocol according to body weight, in order to minimize amount of contrast medium and optimize contrast enhancement in pediatric patients performing thoracic CT examinations. The 80 pediatric patients under the age of 10 were studied. Intravenous contrast material containing 300 mgI/ml was used. The group A injected with a capacity of 1.5 times its weight, and groups B, C and D added 5 to 15 ml of normal saline with a 10% decrease in each. The physiologic model which can be calculated by weight about amount of injection of contrast medium and normal saline, flow rate and delay time were applied. To assess image quality, measured average HU value and SNR of superior vena cava, pulmonary artery, ascending and descending aorta, right and left atrium, right and left ventricle. CT numbers of subclavian vein and superior vena cava were compared to identify the effects of reducing artifacts due to normal saline. Comparing SNR according to the contrast medium injection protocol, significant differences were found in superior vena cava and pulmonary artery, descending aorta, right and left ventricle, and CT numbers showed significant differences in all organs. In particular, B group with a 10% decrease in contrast medium and an additional injection of saline showed a low degree of contrast enhancement in groups with a decrease of more than 20%. In addition, the group injected with normal saline greatly reduced contrast enhancement of subclavian vein and superior vena cava, and the beam hardening artifact by contrast medium was significantly attenuated. In conclusion, the application of physiological protocol for injection of contrast medium in pediatric thoracic CT examinations was able to reduce artifacts by contrast medium, prevent unnecessary use of contrast medium and improve the effect of contrast enhancement.

Evaluation of the Usefulness of the Transmittance of Metal Filaments Fabricated by 3D Printers in Radiation Therapy (방사선 치료에서 3D 프린터로 제작된 금속 필라멘트의 투과율에 관한 유용성 평가)

  • Kwon, Kyung-Tae;Jang, Hui-Min;Yoon, Myeong-Seong
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.965-973
    • /
    • 2021
  • Since radiation therapy is irradiated with high-energy X-rays in a variety of at least 20 Gy to 80 Gy, a high dose is administered to the local area where the tumor is located, and various side effects of some normal tissues are expected. Currently, in clinical practice, lead, a representative material, is used as an effort to shield normal tissues, but lead is classified as a heavy metal harmful to the human body, and a large amount of skin contact can cause poisoning. Therefore, this study intends to manufacture a measurement sheet that can compensate for the limitations of lead using the materials Tungsten, Brass, and Copper of the 3D printer of the FDM (Fused Deposition Modeling) method and to investigate the penetration performance. Tungsten mixed filament transmission measurement sheet size was 70 × 70 mm and thickness 1, 2, 4 mm using a 3D printer, and a linear accelerator (TrueBeam STx, S/N: 1187) was measured by irradiating 100 MU at SSD 100 cm and 5 cm in water using a water phantom, an ion chamber (FC-65G), and an elcetrometer (PTW UNIDOSE), and the permeability was evaluated. As a result of increasing the measurement sheet of each material by 1 mm, in the case of Tungsten sheet at 3.8 to 3.9 cm in 6 MV, the thickness of the lead shielding body was thinner than 6.5 cm, and in case of Tungsten sheet at 4.5 to 4.6 cm in 15 MV. The sheet was thinner than the existing lead shielding body thickness of 7 cm, and equivalent performance was confirmed. Through this study, the transmittance measurement sheet produced using Tungsten alloy filaments confirmed the possibility of transmission shielding in the high energy region. It has been confirmed that the usability as a substitute is also excellent. It is thought that it can be provided as basic data for the production of shielding agents with 3D printing technology in the future.

Treatment of Pyogenic Arthritis of the Knee Using Drainage Tube Insertion in the Posterior Compartment through the Posterior Transeptal Portal after an Arthroscopic Synovectomy (관절경적 활액막 절제술 후 후격막 삽입구를 통한 배액관의 후방 거치를 이용한 무릎의 화농성 관절염 치료)

  • Kim, Tae Ho;Yu, Chang Eon;Shin, Chung Shik
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.3
    • /
    • pp.269-275
    • /
    • 2019
  • Purpose: This study analyzed the treatment effects of drain insertion in the posteromedial portal after an arthroscopic synovectomy and posterior septum resection for pyogenic arthritis. Materials and Methods: From June 2005 to December 2016, 56 cases (55 patients, 1 case of bilateral knee) were diagnosed with pyogenic arthritis and arthroscopic treatment was performed. Fourteen patients (25.0%) were identified with causative organisms. The average follow-up period was 12.3 months, and the mean age was 67.8 years old. Twenty-four cases were males and 31 cases were females. Kellgrene-Lawrence grade (K-L grade) I was 6 patients, II was 20 patients, III was 11 patients, and IV was 18 patients. Surgery was performed through six portal. The posterior septum was removed and a drainage tube was inserted from the posterior medial side to the posterior side of the joint. The Lysholm score was used after surgery for a functional evaluation. The K-L grade at the time of admission and at the last follow-up were compared for a radiological evaluation. Results: The mean normalization period of the C-reactive protein was 59.8 days (6-164 days). Intravenous antibiotics were used for an average of 37.1 days. The results of the functional evaluation revealed a mean Lysholm score of 64.5 (30-98) in a total of 56 cases. Two reoperations was performed, but the treatment was completed with same method in all patients. The K-L grade was similar at the time of surgery and at the last follow-up (p>0.05). Conclusion: The method of drain insertion in the posteromedial portal after arthroscopic synovectomy and posterior septum resection for pyogenic arthritis is an effective technique that can obtain satisfactory results by inducing proper exudate discharge.

A Study on the Radiographic Diagnosis of Caroli's Disease (카롤리병의 방사선학적 진단에 대한 고찰)

  • Yeo-jin Hong;Min-a Kim;Soo-bin Kim;Jin-joo Song;Kyoung-hoon Jang;Min-cheol Jeon;Man-Seok Han
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.385-392
    • /
    • 2023
  • Caroli's disease is a fibrocystic liver disease. Autosomal recessive disorder is characterized by congenital multiple dilatation of the bile duct. Computerized tomography, magnetic resonance imaging, cholangiography and ultrasound are among the methods for diagnosing caroli disease. Computerized tomography is essential for detecting and distinguishing fibroplastic liver disease and is useful for determining intrahepatic bile duct dilatation. However, awareness of the possible side effects of using contrast mediums is necessary. A typical method of magnetic resonance cholangiography is used for magnetic resonance imaging. A non-invasive examination can reduce the pain of the patient, and the anatomical structure of the bile pancreatic duct and the presence or absence of lesions can be easily and quickly observed. Biliary contrast is an effective diagnostic method that can directly visualize various cystic dilatations throughout the enlarged bile duct. However, since this procedure is also an invasive procedure, it is recommended not for diagnosis but for treatment purposes. Ultrasonography can confirm similar findings to computerized tomography. The hepatic artery root is difficult to prove with conventional grayscale ultrasound. However, it is of clinical value in that it can not only describe dilated bile ducts with vascular roots in the tube but also easily identify color Doppler signals in the tube. With the development of video diagnostics, early diagnosis has become possible through computerized tomography, magnetic resonance imaging, cholangiography, and ultrasound. In order to further contribute to the development of video diagnostics so that long-term prognosis can be improved after treatment through early diagnosis, we examined what aspects of each test's caroli disease appear.

Effects of Changes in Collimation Size and the sub ROI on Exposure Index of Hand Radiography (손 방사선검사에서 조사야 크기와 보조관심영역 변화가 노출지수 값에 미치는 영향)

  • Young-Cheol Joo;Dong-Hee Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.851-857
    • /
    • 2023
  • The purpose of this study is to investigate the effect of changes in collimation size and sub ROI on exposure index(EI) in hand radiography, present collimation size and EI suitable for average hand size of Koreans, and present the effect of changes in sub ROI on EI. The subjects of this study were hand-wrist phantom, and the exposure conditions were set to 55 kVp, 125, mA, and 6.25 mAs, and source to image receptor distance was applied to 110 cm. Based on the vendor recommended sub-ROI (18.7" × 18.7", 8" × 10", 8" × 7.4", 6" × 7.4")and the textbook's recommended sub-ROI 8" × 10", each obtaining 30 images, and comparing the EI shown in the equipment. The EI according to the change in the size of the collimation were 1663.7±4.52, 8"×10" is 1489.1±4.49, 8"×7.4" is 1716.9±3.00, 6"×7.4" is 168.7±3.66 for each EI, and the average value of each value was statistically significant. The average EI according to the sub ROI change was 1489.1±4.49 for SS, LS was 1694.8±5.19 for AEC, 2052.9±5.96, VR was 1548.3±3.20, and HR was 1663.2±4.33. The appropriate field size considering the hand size of Koreans was found to be 8"×7.4". In addition, when the field size increases based on the generally known field size (8"×10") during hand radiography, the EI value changes from a maximum of 15% to a minimum of 11%, and the sub ROI shape based on sub ROI 'SS' Depending on the change, the EI value increased from a maximum of 37% to a minimum of 3%.

Effects of The Sub ROI Changes on Exposure Index (Sub ROI 변화가 노출지수에 미치는 영향)

  • Young-Cheol Joo;Dong-Hee Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1149-1155
    • /
    • 2023
  • This study aims to investigate the effect of changes in the Sub ROI on exposure index(EI) and to present indicators of changes in EI values that may occur when changing Sub ROI in clinical practice. This study was conducted on a subject of 20 cm of acrylic for a setting similar to abdominal radiography, and the specifications of one acrylic sheet is 20 × 20 × 5 cm. The survey conditions were the same as 80 kVp , 320 mA, 25 ms, SID 110 cm and the Sub ROI obtained 30 images for each type using five types provided by the equipment company. The EI value provided by the equipment and entrance skin exposure(ESE) were compared and analyzed. The mean value of EI according to the change in Sub ROI was 101.18±0.27 for LS, 106.57±0.31 for AEC, 107.74±0.39 for VR, 107.90±0.38 for HR, and 109.72±0.32 for SS (p<0.01). The average value of ESE by sub ROI type (LS, AEC, VR, HR, SS) was measured to be 476.45±1.71 μGy, 476.92±1.48 μGy, 476.14±2.30 μGy, 475.61±1.96 μGy, and 477.14±1.46 μGy, with statistically significant differences (p<0.01). As a result of this study, the EI according to the sub ROI type is based on LS(109.72), which represents the minimum value. AEC increased 5.3%, VR increased 6.4%, HR increased 6.6%, SS increased 8.4%, and overall, increased by about 5.3%. As for the average value of ESE, HR(475.61 μGy)type showed the minimum value, and based on this, AEC increased 0.27%, VR increased 0.11%, LS increased 0.17%, SS increased 0.32%, and overall, increased by about 0.17%.

Analysis of dose reduction of surrounding patients in Portable X-ray (Portable X-ray 검사 시 주변 환자 피폭선량 감소 방안 연구)

  • Choe, Deayeon;Ko, Seongjin;Kang, Sesik;Kim, Changsoo;Kim, Junghoon;Kim, Donghyun;Choe, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.113-120
    • /
    • 2013
  • Nowadays, the medical system towards patients changes into the medical services. As the human rights are improved and the capitalism is enlarged, the rights and needs of patients are gradually increasing. Also, based on this change, several systems in hospitals are revised according to the convenience and needs of patients. Thus, the cases of mobile portable among examinations are getting augmented. Because the number of mobile portable examinations in patient's room, intensive care unit, operating room and recovery room increases, neighboring patients are unnecessarily exposed to radiation so that the examination is legally regulated. Hospitals have to specify that "In case that the examination is taken out of the operating room, emergency room or intensive care units, the portable medical X-ray protective blocks should be set" in accordance with the standards of radiation protective facility in diagnostic radiological system. Some keep this regulation well, but mostly they do not keep. In this study, we shielded around the Collimator where the radiation is detected and then checked the change of dose regarding that of angles in portable tube and collimator before and after shielding. Moreover, we tried to figure out the effects of shielding on dose according to the distance change between patients' beds. As a result, the neighboring areas around the collimator are affected by the shielding. After shielding, the radiation is blocked 20% more than doing nothing. When doing the portable examination, the exposure doses are increased $0^{\circ}C$, $90^{\circ}C$ and $45^{\circ}C$ in order. At the time when the angle is set, the change of doses around the collimator decline after shielding. In addition, the exposure doses related to the distance of beds are less at 1m than 0.5m. In consideration of the shielding effects, putting the beds as far as possible is the best way to block the radiation, which is close to 100%. Next thing is shielding the collimator and its effect is about 20%, and it is more or less 10% by controlling the angles. When taking the portable examination, it is better to keep the patients and guardians far enough away to reduce the exposure doses. However, in case that the bed is fixed and the patient cannot move, it is suggested to shield around the collimator. Furthermore, $90^{\circ}C$ of collimator and tube is recommended. If it is not possible, the examination should be taken at $0^{\circ}C$ and $45^{\circ}C$ is better to be disallowed. The radiation-related workers should be aware of above results, and apply them to themselves in practice. Also, it is recommended to carry out researches and try hard to figure out the ways of reducing the exposure doses and shielding the radiation effectively.