• Title/Summary/Keyword: Radiologic Science

Search Result 479, Processing Time 0.033 seconds

Investigation into the Actual State of Sanitary Management and Recognition Degree and Infection Level of Ultrasonographic Probes (초음파 탐촉자(Probes)의 위생관리 실태와 감염 인식도 조사 및 세균 오염도 측정)

  • Lee, Chang-Bok;Lee, Yang-Sub;Lee, Won-Hong;Cho, Cheong-Chan;Yoon, Hyang-Yi;Lee, Yong-Moon;Kim, Young-Keun;Lee, Kyung-Sup
    • Journal of radiological science and technology
    • /
    • v.27 no.3
    • /
    • pp.51-58
    • /
    • 2004
  • The gel, which is stained on probe after ultrasonography, is a good circumstances for proliferation of microbe. This study is to investigate into the actual state of sanitary management, recognition degree and infection level of ultrasonographic probes. We had performed a question with telephone to 42 hospitals in Seoul area from December in 2003. We also cultured to obtained a sample from three ultrasonographic units to investigate infection level of the probes. Sanitary management of the probes was performed in 21 hospitals with alcohol cotton. Sanitary management was performed daily in 14 hospitals. Most hospitals used cotton towel for clearing of gel stained on probes. Preventive management against infection was performed in 32 hospitals with vinyl cover, surgical glove, or alcohol sterilization etc. In the recognition degree on infection, the response that using method of ultrasonographic probes is insanitary were in 78.6%(33 hospitals), and 54.8%(23 hospitals) responded that bacteria can be infected through the probes. In the results of germiculture, bacteria and fungi were detected too number of to count, but escherichia coli was not detected. In conclusion, The gel stained on probe after ultrasonography must be cleared completely, and it is necessary that change of recognition on sanitary management.

  • PDF

The Distribution and Patient Care in Radiography for Emergency Outpatients (응급환자의 방사선영상검사 분포 및 Patient Care)

  • Lee, Hwan-Hyung;Kang, Won-Han
    • Journal of radiological science and technology
    • /
    • v.19 no.1
    • /
    • pp.55-74
    • /
    • 1996
  • This study was carried out to improve service efficiency and to cope with a emergency situation in emergency radiography, through analysis of the radiographic distribution and literature cited about emergency care. Data collection of radiographic distribution was surveyed for 761 emergency outpatients who visit during JAN, 1994 at ER of the general hospital in Pusan city. The results is as follows: Emergency radiography rate of simple radiography was 61.1 %, special radiography 2.5 %, CT 12.6 %, and ultrasonography 6.7 %. In simple radiography rate, a high rate was distributed on male(63.6 %), thoracicsurgery part(90.0%), admission patient(74.9 %), and long stayed patient at ER. In special raiography rate, a high rate was observed in urologic part(28.6%), and in CT rate, observed neurosurgery part(49.2 %) and neurologic part(36.7%). Ultrasonography rate was high for female(8.8 %) and internal medicine part(15.9 %). There are distributed regional radiography rate in radiographic type that chest(55.3 %) is high in the simple radiography, urinary system(1.2%) in the special study, and brain(40.0 %) in the CT. Regional radiography rate according to diagnostic department also was showed highly for head(64.6%) in neurosurgery, chest(90.0%) in thoracic-surgery, abdomen(58.0%) in general-surgery, spine (40.0% ) in neuro-surgery, and pelvis(15.9%), upper extrimity(20.5%), and lower extrimity(31.8%) in orthopedic-surgery each. Mean radiographic case number per patient of simple radiography was sinificant on sex, age, transfer relation in both total and radiographic patients(p<0.05). Mean radiographic case number was highly distributed on male(2.2 case number) in sex, on thirties(2.7) in age, transfered patient(2.7) in patient type, and on neurosurgery(3.4) in diagnostic charged part. Total radiographic case number in regional part was highly distributed on chest(499 case number). Considering the above results, emergency radiographer should take care of the elder patient in emergency radiography and get hold of injury mechanism to decrease possible secondary injury during radiography. Because of high radiography rate of urinary system in special study, radiographer should know well about dealing with contrastmedia administration and related instrument. All radiographer who take charge emergency patient should cope with a emergency situation during radiography, Because head trauma patients is very important in patient care, especilly in CT at night, charged doctor should be always silted with CT room and monitoring-patient. Radiography was reqested by many diagnostic department in ER. Considering that rate of simple radiography is high, special room for emergency radiography should be established in ER area, and the radiographer of this room should be stationed radiologic technician who is career and can implement emergency patient care.

  • PDF

Relationship of Compressed Breast Thickness and Average Glandular Dose According to Focus/Filter (초점/필터에 따른 유방 압박 두께와 평균 유선 선량의 관계)

  • Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.261-270
    • /
    • 2009
  • The study examined the relationship between the compressed breast thickness and Average Glandular Dose (AGD) among 1,969 outpatients who went through breast X-ray in a university hospital for 10 months from July 1st, 2007 to April 30th, 2008. Then it analyzed the result acquired from 3,900 cases of Cranio-Caudal (CC) view, especially, when the breasts were compressed (13-15daN). The following is the conclusion driven from the relationship analysis. 1. The subjects aged in 40s and 50s were 2,679 out of 3,900 cases and this figure was 68.69% in all. 2. In terms of distribution depending on focus/filter, 41.0% was Mo/Mo, 34.8% was Mo/Rh, and 24.2% was Rh/Rh. 3. In terms of compressed breast thickness depending on focus/filter, the average thickness was 26.91 mm at Mo/Mo, 38.84 mm at Mo/Rh, and 48.80 mm at Rh/Rh. The average thickness of the entire cases was shown to be 36.27 mm. 4. AGD depending on focus/filter was 1.27 mGy at Mo/Mo, 1.55 mGy at Mo/Rh, and 1.42 mGy at Rh/Rh. The average glandular dose of the entire cases was shown to be 1.43 mGy. 5. The relationship of AGD depending on compressed breast thickness at Mo/Mo was y=0.0318x + 0.470 while it was y=0.0206x + 0.709 at Mo/Rh and y=0.0248x + 0.335 at Mo/Rh. It was highly influenced by the compressed breast thickness, however, more variation was detected at Mo/Mo depending on breast thickness.

  • PDF

Suggestion of The Manual Exposure Condition Guideline for Reducing Patient Dose in Digital Breast Tomosynthesis (디지털 유방단층촬영의 피폭선량 경감을 위한 수동 촬영조건의 가이드라인 제시)

  • Hong, Eun-Ae;Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.483-491
    • /
    • 2016
  • The conditions after exposure to digital mammography and digital breast tomosynthesis were analyzed. The examinations for the ACR phantom were done using manual exposure, not auto exposure, to examine image discrimination and patient dose. As a result, the following results were derived: In the CC exposure, the kVp was 2kVp higher while mAs decreased to 58.6% for the 3D tomography. Such result showed an approximate decrease of 60mAs. At that time, the patients' Average Glandular Dose (AGD) was 1.65mGy in 2D and 1.87mGy in 3D; thus, AGD of 3D was shown to have about 1.13times higher. The result of the manual exposure revealed a reduced mAs of up to 80%; there was no effect in the assessment standard in terms of image discrimination, resulting in more than 10 points. When mAs was reduced to 80% in the manual exposure for ACR phantom, AGD was decreased to 0.66mGy. The diagnostic values of images were maintained and patients dose was reduced in the manual exposure in the AEC condition for 3D. Since the use of 3D has recently increased, using the manual exposure has been recommended in this study to improve the diagnostic value, while, simultaneously reducing patients dose.

Comparison of the Values of Bone Mineral Density Between DEXAs (DEXA 측정기 간 골밀도 값 비교)

  • Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.271-276
    • /
    • 2011
  • Statistical analysis was performed on the patients who took bone densitometry using Lunar and Hologic equipments for 5 months from January $1^{st}$ 2010 to May $30^{st}$, 2010. Patients consisted of 50 in their 40s, 100 in 50s and 50 in 60s. In addition, the results from bone densitometry were carried out on the same subject with two equipments on the same day. In case of 200 subjects, who received the bone densitometry with two equipments, the average age was 54.5 and 54.4 years old, respectively. There was no difference. The T- score of Lunar equipment was $-1.377{\pm}1.221$ and that of Hologic equipment was $-1.806{\pm}1.123$. The T-score of Lunar equipment was measured higher than that of Hologic equipment. T-test was conducted to determine the equality of the mean of two groups with 200 patients. Since the pvalue was 0.000, the value of bone mineral density was significant in two equipments. Furthermore, the patients, who were diagnosed by Lunar, showed more 'normal' and who were diagnosed by Hologic, showed more osteoporosis, which cartegorized by WHO, such as normal, osteopenia, and osteoporosis. Thus, compared results of bone densitometry on lumbar spine L1 - L4 of four normal people with the same equipment showed that T- score of Lunar equipment was $-0.4{\pm}1.2$, and T- score of Hologic equipment was $-1.1{\pm}1.5$. It showed the higher T- score was measured in Lunar equipment as well. Therefore, the correction factor should be considered to use, since T- scores are different between two equipments.

Statistical analysis of national examination for radiological technologists in convergence perspective (통계분석을 통한 융합적 관점에서 분석한 방사선사 국가시험)

  • Choi, Kyoungho;Cho, Jung Keun
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.7
    • /
    • pp.93-99
    • /
    • 2017
  • Necessity of adjustment in level of difficulty of national examination for radiological technologists is being brought up. However, objective reasons are required to make those arguments more valid. Therefore in this research, result of national examination for radiological technologists under present system was analyzed in more convergence perspective via statistical analysis. This will provide basic data which is applicable when system of national examination for radiological technologists undergo improvements. For this, statistical analysis such as descriptive statistics and correlation analysis was conducted using SPSS program. Results are as follow. First, ratio of successful applicants for radiological technologists was highly fluctuant relative to other national examinations like doctor, nurse, physical therapist, etc. Second, level of difficulty and discernment of national examination for radiological technologists were differentiated from other examinations like doctor, nurse, physical therapist. Third, the 43th examination for radiological technologists conducted in 2015 had the highest discernment as 0.41, despite of lowest level of difficulty as 89.2, for radiologic applications. The results of this research is expected to be used as basic data when system of national examination for radiological technologists undergo improvements, in accordance with increased supplying plan of work-forces in medical radiological technologists.

Evaluation of Dose Volume and Radiobiological Indices by the Dose Calculation Grid Size in Nasopharyngeal Cancer VMAT (비 인두암 체적 조절 호형 방사선 치료의 선량 계산 격자 크기에 따른 선량 체적 지수와 방사선 생물학적 지수의 평가)

  • Kang, Dong-Jin;Jung, Jae-Yong;Shin, Young-Joo;Min, Jung-Whan;Shim, Jae-Goo;Park, So-Hyun
    • Journal of radiological science and technology
    • /
    • v.43 no.4
    • /
    • pp.265-272
    • /
    • 2020
  • The purpose of this study was to investigate the dose-volume indices and radiobiological indices according to the change in dose calculation grid size during the planning of nasopharyngeal cancer VMAT treatment. After performing the VMAT treatment plan using the 3.0 mm dose calculation grid size, dose calculation from 1.0 mm to 5.0 mm was performed repeatedly to obtain a dose volume histogram. The dose volume index and radiobiological index were evaluated using the obtained dose volume histogram. The smaller the dose calculation grid size, the smaller the mean dose for CTV and the larger the mean dose for PTV. For OAR of spinal cord, brain stem, lens and parotid gland, the mean dose did not show a significant difference according to the change in dose calculation grid size. The smaller the grid size, the higher the conformity of the dose distribution as the CI of the PTV increases. The CI and HI showed the best results at 3.0 mm. The smaller the dose calculation grid size, the higher the TCP of the PTV. The smaller the dose calculation grid size, the lower the NTCP of lens and parotid. As a result, when performing the nasopharynx cancer VMAT plan, it was found that the dose calculation grid size should be determined in consideration of dose volume index, radiobiological index, and dose calculation time. According to the results of various experiments, it was determined that it is desirable to apply a grid size of 2.0 - 3.0 mm.

Survey of Asbestos-Related Disease on Chest Radiograph of Workers Exposed to Asbestos in Ship Repair (조선수리업종 석면노출 근로자들의 흉부방사선상 석면관련 폐질환 소견의 발생양상)

  • Lee Hyun Jae;Hong Young Seoub;Son Ji Eun;Lee Young Ill;Kim Sang Hoon;Im Hyoung June;Kim Jung Man;Kim Joon Youn
    • Journal of Life Science
    • /
    • v.16 no.1
    • /
    • pp.58-63
    • /
    • 2006
  • There was cross-sectional study on investigating the factors related asbestos-related disease on chest radiograph of workers exposed to asbestos in ship repair. According to Occupational Safety & Health Administration asbestos standard, medical surveillance, chest radiologic study, pulmonary function test and medical questionnaire are performed in 118 subjects exposed to asbestos for 10 years or more in ship repair. The sixteen out of 118 subjects $(13.6\%)$ were observed asbestos-related disease finding on chest radiography. Significant factors related to those finding on chest radiography were abnormal pulmonary function test, cough, sputum, past history of respiratory disease, work duration. Workers with Significant factors related asbestos-related disease finding on chest radiography should be managed on a strict program. Further, factors unrelated with asbestos-related disease finding on this study should be evaluated prospectively for medical surveillance program of workers exposed to asbestos.

Fabrication of $Li_2B_4O_7$ Series Single-Crystal TLDs and their TL properties ($Li_2B_4O_7$ 계열 단결정 TLD 소자의 제작과 특성)

  • Park, Myeong-Hwan;Park, Kang-Soo
    • Journal of radiological science and technology
    • /
    • v.28 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • High-quality single crystals of pure $Li_2B_4O_7$ as well as $Li_2B_4O_7$ doped with Cu, Mn and Mg impurities (1.0mol%, respectively) have been grown from the melt of $Li_2CO_3+2B_2O_3$ by Czochralski method in platinum crucibles. To study the thermoluminescent properties, $Li_2B_4O_7$ series single crystal TLDs were made by cutting in the size of $4{\times}5{\times}1\;mm^3$. The glow curves show two or three peaks which can be easily deconvoluted. It is observed that room temperature($20{\sim}30^{\circ}C$) fadings of the dosimetric peaks of $Li_2B_4O_7$ series single crystal TLDs were about 10 % for 30 days. The relative photon energy response for $Li_2B_4O_7$ series single crystal TLDs were about 85 % when the responses were normalized to that measured with $^{60}Co\;(1.25\;MeV)\;{\gamma}-rays$. The measured data are in a good agreement with theoretical ones. The $Li_2B_4O_7$ series single crystal TLDs fabricated in this work can be used for monitoring personal and environmental radioactivity.

  • PDF

A Study of Uniformity Test in PET/CT (PET/CT 장치의 uniformitly측정에 관한 연구)

  • Kim, Su-Keun;Jung, Hee-Il;Park, Soung-Ock
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.13-19
    • /
    • 2006
  • The PET scanner can detect the photon pair arriving from the source in phantom. The number of light photons released by the crystal(scintillator-BGO or LSO). In recent scintillation crystals in block structures were incorporated into full ring systems, and their resulted marked improvement in spatial resolution and increase in a sensitivity to annihilations. The uniformity of the crystal sensitivity is very important to makes correct information of abnormal states in organs. These factors influenced by the dection efficiency of the scintillators. We have study about the uniformity of crystals to the annihilation, And study about the standard deviation to average counts. The relative standard deviation in central detector groups more uniformed than circumferenced detector groups. It is caused detected quanta of gamma ray by the geometrical factors of PET detector. PET cameras are available with different geometric arrangement and several parallel rings oriented in the axial direction. The center groups from 7th to 40th groups are comparatively uniform and sensitive. But at the circumferenced detectors decreased the sensitivity and uniformity.

  • PDF