• Title/Summary/Keyword: Radiologic Science

Search Result 481, Processing Time 0.021 seconds

Entrance Skin Dose and Image Quality Evaluation According to Use Grid Radiography for the Extremity in FPD System (FPD System에서 상.하지 촬영 시 격자에 따른 환자 선량 및 화질 평가)

  • Lee, In-Ja;Yeo, Young-Bok;Lee, Tae-Sung
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.341-348
    • /
    • 2010
  • By accessing the current status of FPD system use in the hospitals located in Seoul and Gyeonggi Province as well as the entrance skin dose and the image quality evaluation realized by C-D Phantom, and the image assessment by the medical professionals regarding the radiography for the extremity, the following results were derived. 1. According to the evaluation made in the actual use of FPD system (12 machines), the grid ratio varied from 8:1 to 13:1, and 6 machines used the grid ratio with 12:1, realizing the largest number. Among the machines, there were 8 machines that allowed a removable grid while 3 machines did use a removable grid (25.0%). 2. When it came to the equipments used for the experiment, it showed that the amount of the entrance skin dose increased from 4.13 times up to 4.79 times with the grid use. 3. The difference in the entrance skin dose depending on the changes in the exposure condition(0.5times or 2.0times) was not significantly different regardless of the patients' thickness. 4. In terms of the image quality depending on C-D Phantom, the grid use was distinguished well. However, the images were well distinguishable as the exposure condition got increased. 5. In the clinical assessment, the grid use was less effective for the Hand PA, which was considered to shoot a thin body part. It was evaluated that the grid use was preferred for the Knee AP, which was shooting for a relatively thick body part. Nonetheless, 3 out of 5 people said that they would not use the grid if the entrance skin dose to reduced.

A Study of the Development for Fatty Liver Quantification Diagnostic Technology from Ultrasound Images using a Simulated Fatty Liver Phantom (모사 지방간 팬텀을 활용한 초음파영상에서 지방간 정량화 진단 기술 개발을 위한 연구)

  • Yei-Ji Lim;Seung-Man Yu
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.135-144
    • /
    • 2024
  • Ultrasonography examination has limitations in quantifying hepatic fat quantification. Therefore, this study aimed to experimentally demonstrate whether changes in signal attenuation during ultrasound imaging can be quantified using simulated hepatic phantoms to assess hepatic fat content. Additionally, we aimed to evaluate the potential of ultrasound imaging for diagnosing hepatic fatty liver by analyzing the relationship between hepatic fat content and signal intensity in ultrasound images. In this study, we developed a total of five stimulated hepatic phantoms by homogeneously mixing water and oil. We confirmed the fat content of the phantoms using magnetic resonance imaging (MRI) and ultrasound imaging, and measured signal intensity according to distance in ultrasound images to analyze the correlation and mean comparison between fat content and signal intensity. We observed that as the fat content increased, the ultrasound penetration intensity decreased, confirming the potential for quantifying hepatic fat content using ultrasound. Additionally, the analysis of the correlation between the measured fat content using MRI and the signal intensity measured in ultrasound images showed a high correlation. Statistical analysis in our study confirmed that as the fat content increased, the slope representing signal during ultrasound imaging (US-GRE) decreased. In this study, it was statistically confirmed that the US-GRE value of ultrasound images gradually decreases as the fat content increases, and it is believed that US-GRE can serve as a biomarker expressing fatty liver content.

Skull or Brain Metastasis from Thyroid Carcinoma - Analysis of 7 Cases - (두개골 또는 뇌로 전이된 갑상선암 - 7례 분석 -)

  • Kim, Seok-Chul;Jung, Shin;Kim, Jae-Sung;Lee, Jung-Kil;Kim, Tae-Sun;Kim, Jae-Hyoo;Kim, Soo-Han;Kang, Sam-Suk;Lee, Je-Hyun;Park, Jae-Woo;Lee, Min-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.1
    • /
    • pp.89-94
    • /
    • 2001
  • Skull or brain metastasis from thyroid carcinoma is rare. Between Jan. 1993. and Jan. 2000. the authors experienced 7 cases of skull(4 cases) or brain(3 cases) metastasis from thyroid carcinoma. Clinical characteristics, radiologic findings and pathologic features were analyzed retrospectively. Among 4 cases of skull metastasis, 3 cases were follicular carcinoma and one was papillary carcinoma with follicular variant. All cases of brain metastasis were papillary carcinoma. We treated the patients by combination with surgical resection, radioactive iodine therapy and radiation therapy. Characteristics of skull or brain metastasis from thyroid carcinoma is reviewed with a pertinent literature.

  • PDF

Experiment for Clinical Application with Photodiode (Photodiode를 사용한 측정기의 임상응용을 위한 실험)

  • Kim, You-Hyun;Kwon, Soo-Il;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.19 no.2
    • /
    • pp.71-77
    • /
    • 1996
  • Studies were conducted to determine the clinical application of photodiode. We compared photodiode with ion-chamber as to change of tube potential, tube current, mAs and measured decreasing rate of penetration dose. When tube potential was changed from 60 kVp to 120 kVp, output of photodiode and ion-chamber were changed from 0.4 to 1.625, and 1.018 to 4.268, respectively. This was a good agreement to theory that $I=Kv^2it$(I is intensity, K is constant, v is tube potential, i is tube current, t is time). Characteristics for change of tube current and mAs were also a good agreement to theory. And comparison in decreasing rate of penetration dose was similar except above 6 cm in depth. Our results indicated that photodiode was a good instrument for relative measurement of radiation exposure, but we can not use the photodiode for absolute radiation dose.

  • PDF

A Comparison of the Korean and Japanese Medical Technician's. Etc. Act Systems Focusing on Physical and Occupational Therapists

  • Yoon, Tae-Hyung
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.2
    • /
    • pp.128-135
    • /
    • 2016
  • Purpose: The aim of this study was to compare the "Physical Therapist and Occupational Therapist Act" of Japan and the "Medical Technician's. Etc. Act" of Korea in order to establish the grounds for improvement of effective law-making. Methods: We obtained the "Medical Technician's. Etc. Act" from the Korean Ministry of Government Legislation and the "Physical Therapist and Occupational Therapist Act" from the Japanese Ministry of Health, Labor and Welfare. It was translated from an association by related Japanese and experts. Results: The laws consisted of acts, enforcement ordinances, and enforcement regulations in both Korea and Japan. In the Korean case, eight occupations were defined in one law including six types of medical technicians, as well as medical recorders and opticians. The "Physical Therapist and Occupational Therapist Act" in Japan is composed of 6 chapters and 22 articles, while the Korean Act consists of 33 articles without chapters. Among them, 11 articles covered the establishment and management of dental laboratories and eyeglass shops, and only 22 articles were related to physical therapists and occupational therapists. Conclusion: Independent laws should be established for each type of medical technician. They must be comparable to Japanese laws on physical therapists and occupational therapists as well as clinical pathologists, dental hygienists, dental technicians, radiologic technologists, medical recorders, and opticians.

A Study on Fabrication and Characteristics of $CaSO_4:Tb$ TLD ($CaSO_4:Tb$ TLD의 제작과 특성에 관한 연구)

  • Park, Myeong-Hwan
    • Journal of radiological science and technology
    • /
    • v.22 no.1
    • /
    • pp.55-60
    • /
    • 1999
  • In this study, the highly sensitive $CaSO_4:Tb$ glass capsule type TLDs are fabricated and their trap parameters are determined. The optimum conditions of fabricating of $CaSO_4:Tb$ phosphor was obtained to be in impurity concentration of Tb 1.0 mol% and sintering of $600^{\circ}C$, 2 hr. The glow curve of $CaSO_4:Tb$ consists of three glow peaks and these peaks are isolated by thermal bleaching method. Activation energy of the three glow peaks measured by the initial rise, the peak shape and the heating rate method are 0.70, 0.87, and 1.03 eV. The frequency factors are $1.76{\times}10^9,\;1.74{\times}10^9$, and $9.77{\times}10^8\;s^{-1}$, and the kinetic orders are 1.12, 1.46, and 1.34, respectively. The isolated glow peaks are fitted by least square method and optimum temperature range of the main peak for radiation dosimetry is $230{\sim}295^{\circ}C$.

  • PDF

Evaluation of Chest Density in Insight Film (Insight film을 이용한 농도측정 평가)

  • Kwon, Lee-Seon;Park, Jang-Hwan;Lim, Oh-Soo;Jung, Kyong-Mo;Cheung, Hwan
    • Journal of radiological science and technology
    • /
    • v.15 no.2
    • /
    • pp.17-23
    • /
    • 1992
  • Simple chest radiography is the most frequently performed examination in radiologic practice. However, with transmitted dose through chest which has the problem of wide variations in absorption, conventional Film/Screen Combinations Method make it difficult to delineate lung field mediastinum & cardia portion and subdiaphragmatic structures. In order to overcome this problem, we have been tried several methods as follows. High Kilovoltage Technique, Rare Earth Screen/Wide Lattitude Film, Use of Compensating Filter and Digital Beam Attenuator and recently Insigh System has been developed. In this paper, we'd like to discuss Insight film through apperciation by measuring the difference of contrast. In order to evaluate insight film. We have done experiments using Insight System with Simple Phase, Picker 550. We could get an result which was able to overcome the limitted dynamic range of conventional Film/Screen System remarkably.

  • PDF

A Study on Appearances of Desensitized Phenomenon in Chest Roentgenography (흉부X선사진(胸部X線寫眞)에 나타나는 감감현상(減感現象)에 관(關)한 연구(硏究))

  • Kyong, Kwang-Hyon;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.2 no.1
    • /
    • pp.23-29
    • /
    • 1979
  • Roentgenographic film has to be handled with greatest care during removal from the packing, loading of the cassettes and loading of the hanger. In the case of prior to or after exposed film is handled with mechanical pressure in darkroom, the most common phenomena are desensitization or sensitization on roentgenographic film. In order to observe these defect occurring on, it, the author studied on change of the densities where the mechanical pressure reached to the roentgenographic film. 1. The optimal minimum and maximum densities in routine chest x-ray film are from 0.25 to 1.47 2. The dependence of the desensitization occurring on film upon the bent degree of film is in the portion to bent degree over $10^{\circ}$ 3. Appearances of the desensitization on film by the curved degree of film is inverse proportion to it's degree below intervals of 3cm. 4. The more unexposed film is bent with nail tip and is pressured with palm, the more desensitization it was appeared upon film size and pressure weight. 5. The most serious area of desensitization produced by many types of mechanical pressure is in the portion of lung apex and outside lung fields. 6. The tendency of desensitization due to mechanical pressure on unexposed film is more serious than sensitization on exposed film in the view of radiologic diagnosis.

  • PDF

Usefulness of Silicon Bolus Using 3D Printing of Head and Neck Patients (두경부 환자의 3D Printing을 이용한 Silicon Bolus의 유용성)

  • Kwon, Kyung-Tae;Lee, Yong-Ki;Won, Young-Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.909-916
    • /
    • 2019
  • Radiation therapy of oral and head and neck cancers often involves skin in the therapeutic range, and the use of bolus is frequently used. Dose irregularities provide dose uncertainty in patient application. In this study, the physical properties of patients with gel bolus, poly lactic acid (PLA), and silicon using 3D printing were fabricated. Dose uncertainties arising from the actual radiation dose delivery were measured. As a result, PLA bolus was stable in the Common irregularities. Silicon bolus may be useful for patients with severe irregularities or frequent changes in patient's body shape.

A Study of Gamma-ray Distribution around the $^{99}Mo-^{99m}TcO_4$ Generator ($^{99}Mo-^{99m}TcO_4$ Generator의 감마선량 분포에 관한 연구)

  • Park, Soung-Ock
    • Journal of radiological science and technology
    • /
    • v.24 no.1
    • /
    • pp.49-53
    • /
    • 2001
  • A number of radionuclides of interest in nuclear medicine are short lived isotopes that emit only gamma ray. The most of all Dept. of Nuclear Medicine in the hospt. are using the $^{99}Mo-^{99m}Tc$ generator for elution of the short lived isotope $^{99m}TcO_4$. A $^{99}Mo-^{99m}Tc$ generator consists of an alumina column on which $^{99}Mo$ is bound. The parent isotope($^{99}Mo$ : half life 67 hr.) decays to its daughter $^{99m}TcO_4^-$ which is a different element with a shorter half-life. $^{99}Mo$ emitted 41-keV(1.3%), 141-keV(5.6%) 181-keV(6.6%) and 366-keV(1.5%) gamma rays. But $^{99m}TcO_4$ emitted only 140-keV gamma ray. We study about the gamma ray distribution around the $^{99}Mo$ generator. And obtained the result as follows ; 1. Total counted gamma ray from generator smaller in front side than back. 2. The gamma ray emitted from $^{99}Mo$ generator without $^{99m}TcO_4$ vial increased in the back side(Mo column posited side) 3. The gamma ray only from the $^{99m}TcO_4$ vial increased in the front side. 4. Apron can protect gamma ray above 60% of total radiation from the $^{99}Mo$ generator.

  • PDF