가축 사료 중 방사성 물질 허용 기준 설정에 관한 연구 (Studies on the Establishment of Tolerance Level of Radioactive Compounds in Livestock Feeds)

  • 이완로;지상윤;김진규;이윤종;박준철;문홍길;이주운
    • 방사선산업학회지
    • /
    • 제5권4호
    • /
    • pp.337-345
    • /
    • 2011
  • In order to provide an effective preparedness for a nuclear or radiological emergency happening in the domestic or neighborhood countries and to solve the vague fear of the people for the ingestion of radioactive livestock products, the establishment of national guideline level for radionuclides in feed is urgently necessary. This is because it is important to secure the safety and to manage the crisis in the agricultural, fishery and food sector by performing the effective safety control during and after nuclear incident. This study was performed to investigate the report cases of international organizations and foreign countries to set up a domestic control standard for managing radioactive substances that may be contaminated in animal feeds due to the nuclear power plant incident. In addition, an attempt was made to provide a useful reference that can help prepare a domestic control standard, using a coefficient that can consider the transfer into livestock through the intake of radioactive contaminated animal feeds. The standard radioisotopes investigated were confined to radioactive cesium ($^{137+134}Cs$) and iodine ($^{131}I$). Guideline level for the radionuclides was calculated by using the transfer coefficient factor and the maximum daily intake of animal feed provided by IAEA. For example, the maximum daily intake of animal feed was set as $25kg\;d^{-1}$ for dairy cows, $10kg\;d^{-1}$ for beef cattle, $3.0kg\;d^{-1}$ for pigs and $0.15kg\;d^{-1}$ for chickens. The result values for radioactive cesium were calculated as $8,696Bq\;kg^{-1}$, $4,545Bq\;kg^{-1}$, $1,667Bq\;kg^{-1}$ and $2,469Bq\;kg^{-1}$, respectively. The results for radioactive iodine showed the ranges between $741Bq\;kg^{-1}$ and $76,628Bq\;kg^{-1}$. These data can be utilized as a scientific reference for the preparation of a crisis management manual for the emergency control due to nuclear power plant accident in Korea and neighboring country. These results will contribute to establish the safe feed management system at national level as manual for responding the radioactive exposure of agricultural products and animal feeds, which are currently not established.

미국의 건식저장 캐니스터에서의 CISCC 연구에 대한 검토 (Review of Research on Chloride-Induced Stress Corrosion Cracking of Dry Storage Canisters in the United States)

  • 박형규;박광헌
    • 방사성폐기물학회지
    • /
    • 제16권4호
    • /
    • pp.455-472
    • /
    • 2018
  • 국내의 사용후핵연료가 증가함에 따라 사용후핵연료 저장조는 곧 포화가 될 것으로 예상된다. 따라서 사용후핵연료 건식저장 운영 및 관리 방안에 대해 연구하는 것은 매우 중요하다. 미국에서는 오랜 기간 건식저장을 운영해왔으며 이를 바탕으로 사용후핵연료 건식저장 운영 및 관리 방안에 대해 많은 연구가 수행되고 있다. 그러나 우리나라에서는 경수로 사용후핵연료건식저장 경험이 없으며 관련 관리방안 및 구체적인 기준이 매우 부족한 현실이다. 건식저장기간 동안 주요한 이슈중의 하나는 건식저장용기 열화현상이며 대표적으로 응력부식균열에 의한 부식현상이 있다. 미국에서는 U.S. DOE, U.S. NRC, 그리고 EPRI 주관 아래 건식저장 캐니스터에서의 염화물 응력부식균열에 관한 많은 연구들을 수행하고 있다. 또한 건식저장 캐니스터의 염화물 응력부식균열 현상을 설명하기 위해 SNL에서는 확률론적 응력부식균열 모델을 제시하였다. 본 논문에서는 SNL에서 제시한 확률론적 응력부식균열 모델을 검토하였으며 모델에 제시된 주요인자들을 세세하게 분석하였다. 본 논문은 우리나라에서 스테인리스 스틸로 제작된 캐니스터를 경수로 사용후핵연료 건식저장으로 이용할 경우, 건식저장 운영 및 관리 방안을 구축하는 대에 좋은 참고문헌이 될 것이라 사료된다.

진단용 방사성의약품의 품질관리시험 및 기준 (Quality Control Tests and Acceptance Criteria of Diagnostic Radiopharmaceuticals)

  • 박준영
    • 대한임상검사과학회지
    • /
    • 제53권1호
    • /
    • pp.1-10
    • /
    • 2021
  • 방사성의약품은 방사선을 방출하는 방사성동위원소를 의약품에 표지하여 진단 및 치료 목적으로 사용하는 의약품이다. 방사성의약품은 제조 및 품질관리기준을 준수하여 제조해야 하며, 환자에게 투여되기 전 품질관리시험을 실시하여 안전성을 입증해야 한다. 방사성의약품의 품질관리는 시험의 특성에 따라 생물학적 시험과 물리화학적 시험으로 분류할 수 있다. 생물학적 시험에는 무균시험, 엔도톡신시험, 여과막 완전성 시험이 있으며, 물리화학적 시험에는 성상, 확인시험, 방사화학적 순도시험, 이핵종 시험, 화학적 순도시험, 잔류용매 시험, pH, 불용성이물시험, 함량 등이 있다. 주사제의 형태로 제조되는 방사성의약품은 무균상태이어야 하므로 제조 후 무균시험 및 여과막 완전성 시험을 수행하여 완제의약품의 무균성을 입증하며, 원자재 및 제조과정에서 혼입될 수 있는 발열성 물질은 환자의 생명에 위험을 줄 수 있으므로 엔도톡신시험을 실시하여 발열물질의 오염여부를 확인한다. 방사성의약품은 화학적 합성에 의해 제조되기 때문에 완제의약품 내 부산물 및 불순물의 혼입여부를 평가해야 한다. 제조된 방사성의약품의 성상 및 불용성이물을 육안으로 확인하며, 완제의약품 내 잔류할 수 있는 부산물 및 유기용매 등은 환자에게 유해할 수 있으므로 화학적순도, 잔류용매 및 pH를 평가한다. 그리고 방사성의약품으로부터 방출되는 방사선을 이용하여 반감기, 방사화학적 순도, 이핵종, 함량 등을 평가하여 목적하는 방사성동위원소가 기준에 적합하게 의약품에 표지되었는지를 확인한다. 특히, 방사성의약품은 일반의약품과 다르게 방사선 피폭의 위험성이 항상 존재하기 때문에 품질관리 시 검사시간을 줄이도록 노력해야 하며, 방사성물질에 오염되지 않게 주의를 기울여야 한다.

방사성 동위원소 (99mTc, 18F) 선원 사용 시 인체 내부피폭의 정량적 평가를 위한 선량분포 연구 (Dose Distribution Study for Quantitative Evaluation when using Radioisotope (99mTc, 18F) Sources)

  • 지영식;이동연;양현경
    • 한국방사선학회논문지
    • /
    • 제16권5호
    • /
    • pp.603-609
    • /
    • 2022
  • 본 연구에서는 핵의학 분야에서 사용 빈도가 높은 방사성 동위원소 99mTc, 18F을 대상으로 물 팬텀과 전리함을 이용한 실측 데이터와 몬테카를로 법 기반의 모의실험 계산을 통해 인체 내 선량 분포를 평가하여 분석하였다. 실험 결과, 방사성 동위원소를 중심으로 거리가 멀어질수록 선량이 지수함수적으로 감소하는 것으로 나타났으며, 특히, 5 cm 이격 시 급격히 감소하는 경향을 보였다. 이를 수치상으로 보면, 99mTc의 경우 0.16 ~ 2.16 pC/min, 18F의 경우 0.49 ~ 9.29 pC/min 범위에서 형성되었다. 또한, 결과값을 이용하여 계산한 에너지 전달계수는 0.240 ~ 0.260 범위에서 실측값과 시뮬레이션 결과값이 유사하게 나타났다. 이와 같은 결과는 실험 결과값에 대한 신뢰도를 확보한 것으로 판단이 되며, 특히, 인체 내 선원 집적 시 선원 이동 경로를 중심으로 4 cm 이내에 위치한 장기에 선량이 많이 전달될 수 있다는 것을 의미한다. 본 연구는 방사성 동위원소에 의한 내부피폭 선량을 정량적으로 평가하기 위해 선원에서 발생하는 방사선 분포를 계산 하였으며, 실측과 모의실험 결과를 비교 분석을 통해 신뢰도가 높은 결과값을 제시할 수 있었다. 무엇보다도 계측기를 통해 체내 방사선 분포를 직접 측정하여 제시한 부분에서 큰 의미를 가지고 있다.

Alternative Immunossays

  • Barnard, G.J.R.;Kim, J.B.;Collins, W.P.
    • 한국가축번식학회지
    • /
    • 제9권2호
    • /
    • pp.133-139
    • /
    • 1985
  • An immunoassay may be defined as an analytical procedure involving the competitive reaction between a limiting concentration of specific antibody and two populations of antigen, one of which is labelled or immobillized. The advent of immunoassay has revolutionised our knowledge of reproductive physiology and the practice of veterinary and clinical medicine. Radioimmunoassay (RIA) was the first of these methods to be developed, which meausred the analyte with good sensitivity, accuracy and precision (1,2). The essential components of RIA are:-(i) a limited concentration of antibodies, (ii) a reference preparation, and (iii) an antigen labelled with a radioisotope (usually tritium or iodine-125). Most procedures invelove isolating the antibody-bound fraction and measuring the amount of labelled antigen. Good facilities are available for scintilltion counting, data reduction nd statistical analysis. RIA is undergoing refinement through:-(i) the introduction of new techniques to separate the antibody-bound and free fractions which minimize the misclassification of labelled antigen into these compartments, and the amount of non-specfic binding. (3), (ii) the development of non-extration for the measurement of haptens (4), (iii) the determination of a, pp.rent free (i.e. non-protein bound) analytes (5), and (iv) the use of monoclonal antibodies(6). In 1968, Miles and Hales introduced in important new type of immunoassay which they termed immunora-diometric assay (IRMA) based on t도 use of isotopically labelled specific antibodies(7) in a move from limited to excess reagent systems. The concept of two-site IRMAs (with a capture antibody on a solid-phase, and a second labelled antibody to a different antigenic determinant of the analyte) has enabled the development of more sensitive and less-time consuming methods for the measurement of protein hormones ovar wide concentration of analyte (8). The increasing use of isotopic methos for diverse a, pp.ications has exposed several problems. For example, the radioactive half-life and radiolysis of the labelled reagent limits assay sensitivity and imposes a time limit on the usefulness of a kit. In addition, the potential health hazards associated with the use and disposal of radioactive cmpounds and the solvents and photofluors necessary for liquid scientillation counting are incompatable with the development of extra-laboratory tests. To date, the most practical alternative labels to radioisotopes, for the measurement of analytes in a concentration > 1 ng/ml, are erythrocytes, polystyrene particiles, gold sols, dyes and enzymes or cofactors with a visual or colorimetric end-point(9). Increased sensitivity to<1 pg/ml may be obtained with fluorescent and chemiluminescent labels, or enzymes with a fluorometric, chemiluminometric or bioluminometric end-point. The sensitivity of any immunoassay or immunometric assay depends on the affinity of the antibody-antigen reaction, the specific activity of the label, the precision with which the reagents are manipulated and the nonspecific background signal (10). The sensitivity of a limited reagent system for the measurement of haptens or proteins is mainly dependent upon the affinity of the antibodies and the smalleest amount of reagent that may be manipulated. Consequently, it is difficult in practice to improve on the sensitivity obtained with iodine-125 as the label. Conversely, with excess reagent systems for the measurement of proteins it is theoretically possible to increase assay sensitivity at least 1000 fold with alternative luminescent labels. To date, a 10-fold improvement has been achieved, and attempts are being made to reduce the influence of other variables on the specific signal from the immunoreaction.

  • PDF

238,235U, 232Th과 40K의 베타선 및 감마선에 의한 토양의 흡수선량 환산 인자 (Dose rate conversion factor for soil by the beta-rays and gamma-rays from 238,235U, 232Th and 40K)

  • 김기동;음철헌;방준환
    • 분석과학
    • /
    • 제20권6호
    • /
    • pp.460-467
    • /
    • 2007
  • 자연계에 존재하는 $^{238}U$, $^{235}U$, $^{232}Th$ 그리고 $^{40}K$의 감마선과 베타선에 대해 토양의 흡수선량을 평가하기 위한 유효 흡수선량 환산인자를 계산하였다. 이 때 감마선과 베타선에 대한 붕괴당 에너지, 반감기, 분기율등의 핵자료들은 National Nuclear Data Center (NNDC)의 최근 자료들을 이용하였다. 본 연구에서 계산한 흡수선량 인자 및 이를 이용하여 얻은 $^{238}U$, $^{232}Th$ 그리고 $^{40}K$의 베타선과 감마선에 유효흡수선량은 1998년 Aitken의 결과와 비교적 잘 일치하였지만, $^{235}U$의 경우는 많은 차이가 있음을 확인하였다. 한국 충북 청원군 오성에 있는 선사유적지(만수리) 내의 토양에 대해 고 분해능 감마선 분광 분석 장치(HP Ge 검출기)로 지각 방사선의 감마선 스펙트럼을 측정하고, 계산된 유효 흡수선량 환산인자를 이용하여 연간방사선량을 평가하였는데, 연간방사선량이 3.8~5.9 mGy/year으로 평가되었다. 또한 Rn 이하의 붕괴 핵종을 포함하여 연간방사선량을 평가하는 경우와, 이를 포함하지 않고 연간방사선량을 평가하는 경우는 9~30 % 차이를 나타내었다. 이 흡수선량 환산인자로 토양에 존재하는 자연 방사성 동위원소들의 베타선과 감마선에 대한 유효 흡수선량 평가법이 확립하였다.

치료용 방사성동위원소 사용 시 단일 세포의 핵 크기 변화에 따른 흡수선량 분석 (Analysis of Absorbed Dose on the Nucleus Size Change of Single Cells using Therapeutic Radioisotopes)

  • 김유수;조용인
    • 한국방사선학회논문지
    • /
    • 제16권7호
    • /
    • pp.1007-1014
    • /
    • 2022
  • 표적 방사성핵종 치료(targeted radionuclide therapy, TRT)는 방사성의약품을 사용하여 종양세포를 치료하는 방법이다. 인체의 조직을 구성하는 세포와 핵은 구형과 타원형으로 구성되어 있지만, 암세포의 경우 다양한 형태의 세포 형태로 이루어져 있다. 이에 본 연구는 몬테카를로 방법을 통해 표적 방사성핵종 치료 시 사용되는 베타선 방출 핵종을 대상으로 단일 세포 내 세포핵의 크기 변화에 따른 세포 구성 영역별 흡수선량을 분석하였다. 세포는 5 ㎛, 10 ㎛ 두 가지의 크기의 구 형태로 선정하였으며, 세포의 내부 구성은 세포핵, 세포질, 세포 표면으로 구분하였으며, 세포핵의 크기 증가에 따른 흡수선량을 평가하였다. 그 결과, 표적 방사성핵종 중 177Lu이 세포 모든 구획에서 가장 높은 선량을 나타냈으며, 세포 내 핵의 비중이 증가함에 따라 세포 표면의 흡수선량은 증가되었으나, 세포질과 세포핵의 흡수선량은 감소하는 경향을 보였다. 따라서 표적 방사성핵종 치료 시 암세포의 크기를 고려한 방사성핵종의 선택과 적절한 방사능량 결정이 중요할 것으로 판단된다.

안전조치 사찰을 위한 휴대형 HPGe 검출기 시제품 성능평가 실험 (Performance Test of Portable Hand-Held HPGe Detector Prototype for Safeguard Inspection)

  • 곽성우;안길훈;박일진
    • Journal of Radiation Protection and Research
    • /
    • 제39권1호
    • /
    • pp.54-60
    • /
    • 2014
  • IAEA는 핵물질 계량 관리 검사를 위해 다양한 방사선 검출기를 사용하고 있다. 주로 HPGe, NaI(Tl), CZT 등이 사용되며, 정확한 측정이 요구되는 검사에는 고분해능 HPGe 검출기 활용도가 높다. HPGe 검출기는 추가적인 냉각장치로 인하여 부피가 크고 무거우며, 사용하기 전에 충분히 냉각시켜야 하기 때문에 측정의 준비 시간이 많이 걸린다는 단점이 있다. 이러한 문제점을 해결하기 위해 가볍고 짧은 사용 전 냉각이 요구되는 휴대형 HPGe가 개발되었다. 본 논문은 개발된 휴대형 HPGe 검출기 시제품을 실제 IAEA 사찰 현장에 적용하여 얻은 성능평가 결과를 기술한다. 휴대형 HPGe로 얻은 방사선 스펙트럼은 핵물질 종류와 농축도에 따라 다른 특징을 보였고, 또한 $^{235}U$$^{238}U$의 붕괴 계열에서 방출되는 감마선 및 우라늄의 특성 x-선 차이도 확인할 수 있었다. 그리고 휴대형 HPGe 검출기 시제품으로 측정한 농축도는 핵물질 종류에 따라 실제값과 9 ~ 27%의 상대적 오차를 보였다. 휴대형이라는 소형 검출기의 한계 때문에 일부 핵물질은 IAEA에서 요구하는 정확도를 만족시키지 못하는 경우도 있었지만 향후 추가적인 연구의 수행으로 이러한 문제점은 해결 가능할 것으로 판단된다. 본 논문은 새로운 휴대형 HPGe 검출기를 안전조치에 적용한 사례와 측정한 스펙트럼을 농축도 분석 코드로 분석한 결과를 다룬다. 따라서 국내 원자력시설의 우라늄 농축도 검증을 위한 IAEA 안전조치 사찰 결과를 분석한 논문이 별로 발표되지 않은 상황에서, 본 논문은 안전조치 검사 결과 분석에도 유익할 것으로 판단된다. 개발된 방사선 검출기의 개선 사항도 함께 논의하였으므로 향후 관련 분야 방사선 검출기 개발에도 기여할 것으로 예상된다.

폐석탄광미에서 유래한 중금속과 자연방사능의 분포 및 발생 특성 (Occurrence and Distribution of Heavy Metals and Natural Radioisotopes Recovered at the Abandoned Coal Mine Tailings)

  • 정덕영;조일식
    • 한국토양비료학회지
    • /
    • 제38권3호
    • /
    • pp.142-149
    • /
    • 2005
  • 본 연구는 충남 보령시 청라면에 위치한 폐광산광미로부터 청라저수지 저니토에 이르기까지 토양에 존재하는 중금속과 자연방사능원소간의 발생과 분포에 대하여 조사하였다. 조사 결과 광미영향 지점과 비영향 지점간의 중금속과 자연방사능원소 함량에는 현저한 차이가 있었다. 중금속의 분포 특성은 Pb ($1.32-29.96mg\;kg^{-1}$, 평균 $10.44mg\;kg^{-1}$), Cd ($0.15-0.76mg\;kg^{-1}$, 평균 $0.51mg\;kg^{-1}$), Cu ($0.28-49.67mg\;kg^{-1}$, 평균 $12.43mg\;kg^{-1}$), Cr ($1.31-13.18mg\;kg^{-1}$, 평균 $4.87mg\;kg^{-1}$)으로 조사 되었다. 그리고 Pb와 Cu의 조사지점별 함량 변이는 다른 중금속에 비해 매우 높았다. 건조한 토양을 기준으로 한 자연방사능 함량은 Pb-210 ($4.87dpm\;g^{-1}$), Th-234 ($3.52dpm\;g^{-1}$), Ra-226 ($2.88dpm\;g^{-1}$), Ra-228 ($7.30dpm\;g^{-1}$), K-40 ($58.06dpm\;g^{-1}$) 순으로 나타났으나 핵실험 등의 낙진으로 인하여 대기로부터 유입되는 Cs-137은 발견되지 않았다. 이러한 결과를 기준으로 하여 석탄광미 자체에 포함된 자연방사능 함량과 조시지점에서 조사된 자연방사능 함량을 비교하였을 때 Pb-210 (4.41%), Th-234 (3.60%), Ra-226 (2.09%)로 매우 낮은 비율로 조사되었으나 Ra-228 (266%)과 K-40 (308%)은 석탄광미보다 광미장 외의 지점에서 더 높은 비율로 존재함을 알 수 있었다. 그리고 중금속과 자연방사능의 발생 정도 사이에는 상관관계가 낮았다.

방사성동위원소(放射性同位元素)를 이용(利用)한 적혈구수명측정법(赤血球壽命測定法)(ICSH추천(推薦)) (Radio-isotope Red Cell Survival Studies Recommended by ICSH)

  • 대한핵의학회
    • 대한핵의학회지
    • /
    • 제5권1호
    • /
    • pp.1-10
    • /
    • 1971
  • 혈액질환(血液疾患), 특히 용혈성빈혈(溶血性貧血)을 수반(隨伴)한 경우(境遇)에 적혈구(赤血球)의 생성(生成) 및 파괴과정(破壞過程)을 정확(正確)히 파악(把握)하는 것은 중요(重要)하여 특히 적혈구수명측정(赤血球壽命測定)은 빈혈(貧血)의 본능(本能) 및 발생기전(發生機轉)을 이해(理解)하는데는 물론 병인적(病因的) 치료(治療) 및 예후(豫後)를 결정(決定)하는데 대단(犬端)히 유용(有用)하다. 적혈구수명측정(赤血球壽命測定)에는 1919년(年) Ashby가 개발(開發)한 differential agglutination법(法)이 이용(利用)되어 왔으나 수혈(輸血)에 따른 위험(危險)이 있고 방법(方法)이 복잡(複雜)하다는 단점(短點)을 가져 새로운 적혈구수명측정법(赤血球壽命測定法)이 연구(硏究)되어 왔다. 최근(最近)에 $^{51}Cr$이나, $^{32}DFP$같은 방사성동위원소(放射性同位元素)를 이용(利用)한 방법(方法)이 도입(導入)된 이래(以來) 임상적(臨床的)으로 적혈구수명측정(赤血球壽命測定)이 많이 시행(施行)되고 있지만 아직까지도 그 방법(方法)이나 결과(結果)의 해석(解釋)에 표준화(標準化)가 안되어 있다. 현재(現在) 임상영역(臨床領域)에서 가장 널리 이용(利用)되고 있는 적혈구수명측정법(赤血球壽命測定法)은 방사성(放射性) chromium($^{51}Cr$)법(法)으로 1950년(年) Gray와 Sterling에 의(依)해 창안(創案)된 이래(以來) 많은 학자(學者)들에 의(依)해 여러 가지 변법(變法)이 고안(考案)되어 왔는데, 이의 가장 큰 이유(理由)는 $^{51}Cr$이 적혈구표지(赤血球標識)에 가장 이상적(理想的)인 것만은 아니고 그 결과(結果)에 많은 요인(要因)들이 영향(影響)을 미치기 때문이다. 또 이런 변법(變法)의 사용(使用)은 각(各) 검사(檢査)에서 계산(計算)된 측정치(測定値)에 차이(差異)가 있어 그 결과(結果)의 해석(解釋) 및 비교(比較) 검토(檢討)에 적지않은 난점(難點)이 생겨 표준화(標準化)된 공통적(共通的)인 방법(方法)의 사용(使用)이 중요(重要)하다는 사실(事實)이 인식(認識)되게 되었다. 1966년(年) 호주(濠洲)의 Sydney에서 개최(開催)되었든 제11차(第11次) 국제혈액학회(國際血學會)때 열린 제4차(第4次) International Committee for Standardization in Haematology(ICSH)에서 Diagnostic Applications of Radioisotopes in Haematology에 관(關)한 expert panel을 갖을것을 의결(議決)하여 다음과 같은 12명(名)의 위원(委員)이 결정(決定)되었으며 위원회(委員會)의 의장(議長)에 Dr. Szur, 총무(總務)에 Dr. Glass가 각각(各各) 선임(選任)되었다. 그간(間) 1967년(年) 영경(英京) London에서 첫 회합(會合)이 있은후(後) New York, Vienna(IAEA후원(後援)) Brthesda(NIH후원(後援))에서 전문위원회(專門委員會)를 갖고 적혈구수명측정법(赤血球壽命測定法)에 관(關)한 의견(意見)의 일치(一致)를 보았다. ICSH와 국제혈액학회(國際血學會)에서는 이번에 결정(決定)된 적혈구수명측정법(赤血球壽命測定法)을 널리 소개(紹介)하며, 측정법(測定法)과 얻어진 결과(結果)의 해석(解釋)에 표준화(標準化)를 기(期)할 목적(目的)으로 이에 연관성(聯關性)있는 전문지(專門誌)에 게재(揭載)할 것을 요청(要請) 받었기에 이에 전문(全文)을 소개(紹介)하는 바이다. 이들은 방사성(放射性) chromium 법(法)의 모든 세부적(細部的)인 면(面)을 표준화(標準化)하고 있으며 그간(間) 가장 논란(論難)의 대상(對象)이 되었던, $^{51}Cr$-표지방법(標識方法)에 있어서의 세가지 변법(變法), 즉 ACD법(法), Citrate-wash법(法), ACD/ascorbic acid법(法)을 모두 인정(認定)하고 있다. 또한, DFP($DF^{32}P$ 또는 $^3H-DFP$) 표지법(標識法)의 표준방법(標準方法)도 기술(記述)하고 있으며, 더욱 중요(重要)한 것은 적혈구수명측정법(赤血球壽命測定法)으로서 현재(現在)까지 대부분(大部分)의 학자(學者)가 사용(使用)하여 왔던 지표(指標)인 $T_{50}Cr$ 대신(代身)에 mean red cell life span을 사용(使用)할 것을 권(勸)하고 있다.