• Title/Summary/Keyword: Radiography, Interventional

Search Result 13, Processing Time 0.018 seconds

A Study on the Evaluation of Patient Dose in Interventional Radiology (중재적방사선검사에서 환자 피폭선량에 관한 연구)

  • Park, Hyung-Sin;Lim, Cheong-Hwan;Kang, Byung-Sam;You, In-Gyu;Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.299-308
    • /
    • 2012
  • To perform patient dose surveys in major interventional radiography procedures as a mean of inter-institutional comparison and of establishing reference dose levels with the ultimate goal of optimizing patient doses in the field of interventional radiography. We reviewed international patient dose survey data in the literature and measured patient dose in major interventional radiography procedures (TACE, AVF, PTBD, TFCA, GDC embolization). ESD(Entrance Skin Dose) was measured using TLD chips attached to the patient skin and ED(Effective Dose) was calculated using angiography unit-derived DAP. A survey of patient dose in interventional radiography procedures were also performed with a questionnaire for interventional radiologists and we proposed a guideline for optimizing patient doses in the field of interventional radiology. The patient dose survey data in interventional radiography procedures were very rare in literature compared with those in diagnostic radiography procedures. In TACE, the mean ED was 25.43 mSv and the mean ESD was 511.75 mGy. The mean ED of TACE was not high, but the cumulative dose should be checked, due to longer procedure TACE. In TFCA, the mean ED was 22.6 mSv and it was relatively high compared with data of other countries. In GDC embolization, the mean ED was not available, because GDC embolization was performed with old Image-Intensifier-type unit and there has no unit-installed ionization chamber. Also, the mean ESD of GDC embolization was up to 2,264 mGy and further studies are needed to calculate the net ED of GDC embolization. Patient dose occurred during interventional radiography procedures are high related with the difficulty of the procedure, fluoroscopy time, the number of angiographies and the treatment protocol. Therefore, continuous education and efforts should be made to optimize the patient dose in the field of interventional radiology.

Interventional radiography in management of high-flow arteriovenous malformation of maxilla: report of a case

  • Khambete, Neha;Risbud, Mukund;Mehta, Nikit
    • Imaging Science in Dentistry
    • /
    • v.41 no.3
    • /
    • pp.123-128
    • /
    • 2011
  • Arteriovenous malformations are extremely rare conditions in that can result from abnormalities in the structure of blood vessels, which may be potentially fatal. A 30-year-old female patient visited our hospital with a complaint of swelling on the right maxillary posterior gingiva along with the large port-wine stain on right side of face. On clinical examination, the swelling was compressible and pulsatile. Radiographic examination revealed a lytic lesion of maxilla. Diagnostic angiography revealed a high-flow arteriovenous malformation of maxilla which was treated by selective transarterial embolization of maxillary artery using polyvinyl alcohol particles.

Development of Biodegradable Polymeric Membrane for Interventional Procedure: Preliminary Study (인터벤션 시술을 위한 생분해성 고분자막의 개발 : 예비연구)

  • Bang, Jung-Wan;Hyun, Chang-Yong;Kim, Tae-Hyung;So, Woon-Young;Kim, Jin-Tae;Kim, Sang-Sub;Jung, Hee Dong;Heo, Yeong Cheol
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.15-20
    • /
    • 2014
  • This study was to evaluate clinical feasibility of biodegradable polymeric membrane for interventional procedure in preliminary study. Bio-degradable polymetric membrane was produced into a solution by mixing hyaluronic acid powder with NaOH solution in a heating mantle. Three different concentrations of contrast media (10, 20, and 30 vol%) were added to the produced soluble powder, and vertical agitation was performed for 12 hours at a speed of 100 to 200 rpm at a room temperature. It was freeze dried for 24 hours at a temperature $80^{\circ}C$. Pressure on the freeze dried sample was exerted by a hydraulic press in order to form the freeze dried sample into a membrane. The membrane produced with varying contrast medium concentration was visually examined by a scanning electron microscope and radiographically inspected. Under the visual examination, the higher the concentration of contrast medium, the rougher the surface. Radiographic transparency was similar under all conditions of fluoroscopic radiography, simple radiography, and serial radiography. In conclusion, this preliminary study verified that bio-degradable membrane produced with hyaluronic acid was a material with clinical usability.

The Technologic Consideration of Using for DSA (DSA에 대한 기술적 고찰)

  • Cho, Young-Ki
    • Journal of radiological science and technology
    • /
    • v.17 no.2
    • /
    • pp.13-20
    • /
    • 1994
  • The paper is on the record of radiography the patients with SIEMENS ANGIOSTAR/POLYTRON S PLUS angiosystem with DSA system in the Chonbuk National University Hospital from October 1993 to June 1994. The results are as follow : 1. Among the total No, 836 case of utilization, angiography are 316(37.8 %), interventional radiography are 256(34.2 %), and dacryocystography and sialography are 168(20/1 %). Therefore non-angiogrlphy procedure are incerasing. 2. The aomunt of contrast material used are half as much as conventional angiovascular system. 3. The amount of film consumed are $10{\sim}15%$ of that of conventional angio vascular system and reduction of procedure time are $40{\sim}50%$. 4. Admitting that dignostic utility is in the utilization by examination region, there should be technological study which deal with fine vessel and motion artifact problem.

  • PDF

Radiation safety for pain physicians: principles and recommendations

  • Park, Sewon;Kim, Minjung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • v.35 no.2
    • /
    • pp.129-139
    • /
    • 2022
  • C-arm fluoroscopy is a useful tool for interventional pain management. However, with the increasing use of C-arm fluoroscopy, the risk of accumulated radiation exposure is a significant concern for pain physicians. Therefore, efforts are needed to reduce radiation exposure. There are three types of radiation exposure sources: (1) the primary X-ray beam, (2) scattered radiation, and (3) leakage from the X-ray tube. The major radiation exposure risk for most medical staff members is scattered radiation, the amount of which is affected by many factors. Pain physicians can reduce their radiation exposure by use of several effective methods, which utilize the following main principles: reducing the exposure time, increasing the distance from the radiation source, and radiation shielding. Some methods reduce not only the pain physician's but also the patient's radiation exposure. Taking images with collimation and minimal use of magnification are ways to reduce the intensity of the primary X-ray beam and the amount of scattered radiation. It is also important to carefully select the C-arm fluoroscopy mode, such as pulsed mode or low-dose mode, for ensuring the physician's and patient's radiation safety. Pain physicians should practice these principles and also be aware of the annual permissible radiation dose as well as checking their radiation exposure. This article aimed to review the literature on radiation safety in relation to C-arm fluoroscopy and provide recommendations to pain physicians during C-arm fluoroscopy-guided interventional pain management.

A Study of Diagnostic Reference Levels for Coronary Angiography and Percutaneous Coronary Intervention in Gyeongsang Area (관상동맥 조영술 및 경피적 관상동맥 중재술에 대한 진단참고준위에 관한 연구; 경상도지역중심)

  • Si-Wang Lim;Jung-Su Kim;Pyong-Kon Cho
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.123-129
    • /
    • 2023
  • Interventional cardiology procedures can involve relatively high radiation doses compared to conventional radiography. During CAG, CAG + PCI and PCI the same area is exposed to radiation for a long period. In this study, radiation exposure data of 421 examinations in Gyeongsang area were collected, and the DRLs and ADs in actual medical practice for three types of interventional cardiology procedures in Korea were established. In CAG 286 case, 75th percentile DRLs and ADs of the total DAP were 55.89 Gy·cm2 and 37.47 Gy·cm2 , respectively. In CAG + PCI 92 case, those values were 222.84 Gy·cm2 and 117.51 Gy·cm2 respectively. In PCI 43 case, those values were 198.73 Gy·cm2 and 120.13 Gy·cm2 respectively. In this study, for the first time, the diagnostic reference level of interventional cardiology procedures in Gyeongsang area were established. Using the diagnostic reference level of interventional cardiology procedures derived from this study, it will help to identify and improve the level of exposure dose in the region and country.

Patient Radiation Dose Values During Interventional Cardiology Examinations in University Hospital, Korea (심장혈관 조영술과 심장혈관 인터벤션의 환자 선량 평가)

  • Kim, Jung-Su;Lee, Joun-Hyuk;Jung, Hae-Kyoung;Kim, Jung-Min;Cho, Byung Ryul
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.27-33
    • /
    • 2016
  • The use of cardiac angiography (CA) and the interventional procedures is rapidly increasing due to the increase in modern adult diseases. Cardiovascular intervention (CI) is an examination method where radiation is applied to the same area for a long period, and thus may cause skin injury. In this study, we investigate the diagnostic reference level (DRL) of the cardiovascular intervention (CI) carried out by medical institutions and use it as a tool to reduce patient exposure dose. In this study, the DRL was set by acquiring information about the cumulative fluoroscopy time, cumulative fluoroscopy dose-area product (DAP), radiography DAP, cumulative DAP, air kerma, number of video clips, and the total number of images from the cardiac angiography and interventional procedures performed on 147 patients. The DAPs corresponding to the DRL of cardiac angiography(CA) and that of the interventional procedures were shown to be $44.4Gy{\cdot}cm2$ and $298.6Gy{\cdot}cm2$, respectively; the corresponding DRLs of fluoroscopy time were shown to be 191.5s and 1935.3s, respectively. A DRL is not a strict upper bound for radiation exposure. However, the process of setting, enacting, and reviewing the DRLs for the dose by medical institutions will contribute to a reduction in the unnecessary exposure dose of patients.

Dose Assessment of the Eye of the Operator in the Field of Angiography and Interventional Radiography (혈관조영 및 중재적 시술 분야 내 종사자의 눈에 대한 선량평가)

  • Kim, Jung-hoon;Cho, Yong-In
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.209-216
    • /
    • 2018
  • In the field of angiography and interventional radiology, it is said that the risk of radiation exposure to the eyes is high due to the characteristics of work, but currently divided dose assessment and management are not carried out in reality. Therefore, in this study, in order to evaluate the dose of the operator in the surgical environment and to analyze the shields, firstly, we selected the point where the operator is mainly located, evaluated the exposure dose of the eye after attaching the pocket dosimeter to the lateral angle point of the head and neck phantom, and evaluate shielding effect when wearing lead glasses that is currently commercialized. Secondly, we evaluated the tendency of the exposure dose of the eye and the shielding effect through simulation in the same geometric structure as the actual measurement. As a result, in the case of measurement using a dosimeter, the cumulative dose increased with the increase of the fluoroscopic time, and the tendency was different according to the position of the operator. Simulation results show that the dose distribution of the eye lens in the mathematical phantom is about 1.1 ~ 1.3 times higher than that of the cornea. Also, The protective effect of the lead glasses showed a shielding effect of at least 3.7 ~ 21.4% in each eye.

Necessity of Mandatory Records on Radiological Examination (방사선검사에 관한 기록 의무화의 필요성)

  • Hong, Dong-Hee;Lim, Cheong-Hwan;Kim, Yon-Min;Kim, Eun-Hye;Yoo, Se-Jong;Yoon, Yong-Su;Lim, Woo-Taek;Jung, Young-Jin;Jung, Hong-Ryang;Joo, Young-Cheol;Choi, Ji-Won;Kang, Byung-Sam;Park, Myeong-Hwan;Back, Geum-Mun;Yang, Oh-Nam;Rhim, Jae-Dong;Jeong, Bong-Jae
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.399-407
    • /
    • 2021
  • This study discussed the validity and necessity of compulsory recording of radiographic examination performed by radiological technologist on patients in medical institutions related to radiation exposure. Also, this study provided reasonable evidence of radiographic examination related medical records can contribute to the improvement of public health. Based on overseas cases of implementing a radiographic examination record system, the essential items to be included in medical record are the exposure date, exposure time, exposure method, exposure conditions that is tube voltage, tube current. Name and license number of the radiological technologist who performed the examination should be include in medical record. It is expected that the medical record of the total amount of radiation exposure per year would be in giving the maximum benefit with the minimum exposure to the medical radiation examination of the patient. In addition, interventional radiography medical record should also include exposure time, type and dose of the contrast medium.

Deep vein thrombosis caused by malignant afferent loop obstruction

  • Kang, Eun Gyu;Kim, Chan;Lee, Jeungeun;Cha, Min-uk;Kim, Joo Hoon;Park, Seo-Hwa;Kim, Man Deuk;Lee, Do Yun;Rha, Sun Young
    • Journal of Yeungnam Medical Science
    • /
    • v.33 no.2
    • /
    • pp.166-169
    • /
    • 2016
  • Afferent loop obstruction following gastrectomy is a rare but fatal complication. Clinical features of afferent loop obstruction are mainly gastrointestinal symptoms. A 56-year-old female underwent radical total gastrectomy with Roux-en-Y esophagojejunostomy for treatment of advanced gastric cancer. After fourteen months postoperatively, she showed gradual development of edema of both legs. Computed tomography (CT) scan showed disease progression at the jejunojejunostomy site and consequent dilated afferent loop, which resulted in inferior vena cava (IVC) compression. A drainage catheter was placed percutaneously into the afferent loop through the intrahepatic duct and an IVC filter was placed at the suprarenal IVC, and self-expanding metal stents were inserted into bilateral common iliac veins. With these procedures, sympotms related with afferent loop obstruction and deep vein thrombosis were improved dramatically. The follow-up abdominal CT scan was taken 3 weeks later and revealed the completely decompressed afferent loop and improved IVC patency. Surgical treatment should be considered as the first choice for afferent loop obstruction; however, because it is more immediate and less invasive, non-surgical modalities, such as percutaneous catheter drainage or stent placement, can be effective alternatives for inoperable cases or risky patients who have severe medical comorbidities.