• Title/Summary/Keyword: Radiographic method

Search Result 373, Processing Time 0.023 seconds

Application of Traditional Acupuncture on Canine Intervertebral Disc Disease (개에서 추간판 질환에 대한 침술치료 증례)

  • 정성목;박수원
    • Journal of Veterinary Clinics
    • /
    • v.21 no.1
    • /
    • pp.49-51
    • /
    • 2004
  • A four-year-old female Pekingese dog was presented with intermittent ambulatory hindlimb lameness and severe back pain. The course of the disease was acute and static and 5 days passed by until presentation. In neurological examination, severe back pain and slightly decreased proprioception in right hindlimb were shown. In radiographic examination, radiopacity was increased at T10-11 intervertebral disc space. According to the history taking, neurological examination and radiographic examination, it was tentatively diagnosed as intervertebral disc disease (IVDD). Conservative treatment was performed including cage rest, medication with prednisolone and traditional acupuncture. Acupoints were GV-6, GV-7, BL-18, BL-19. BL-40 and GB-34. Dry needlings rested for 20 minutes. Just after the first acupuncture treatment back pain was significantly decreased. With additional acupuncture treatment, all the clinical signs were not observed. It is considered that conservative therapy including traditional acupuncture, medication and cage rest might be the first choice of therapeutic method for Grade I or II IVDD in dogs.

- Development of Digital Fluoroscopic Image Recording System for Customer Safety - (고객 안전을 위한 디지털 방사선장치(DRF)의 투시영상기록장치 개발)

  • Rhim Jae Dong;Kang Kyong Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.6 no.3
    • /
    • pp.303-309
    • /
    • 2004
  • Many system devices for fluoroscopic and general X-ray studies in diagnostic radiographic system have been being changed from analog mode to digital mode. In addition, among diagnostic imaging and radiologic examinations, fluoroscopic studies that requires functional diagnosis is being widely used. The video recording method of fluoroscopic studies has been useful in functional image diagnosis and dynamic image observation, but the utility of its image quality is being reduced because of limitation in setting play segments of the video player, inconvenience of play, difficulties in preserving reproduced images, the change of image quality, etc. In order to complement these shortages, it is necessary to facilitate access to patient diagnosis information such as storing, editing and sharing functional diagnosis images in response to the trend of the digitalization of digital radiographic & fluoroscopic system(DRF). Thus this study designed and implemented a device of storing functional dynamic images real time using a computer rather than existing video recording, aiming at contribution to functional image diagnosis.

Comparison Film Screen System with Digital Radiographic System in upper gastrointestinal study (Film screen system과 DR system하의 상부위장관 조영술 진단 결과의 비교 분석)

  • Lee Hee Jeong;Son Soon Yong;Kang Sung Ho;Jang Vong Cheol;Ryu Myeong Sun
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.28 no.1
    • /
    • pp.55-60
    • /
    • 2002
  • Purpose : The aim of this study is to rise interest in system control for digital image of high quality by investigating diagnostic value of Digital radiographic system in upper gastrointestinal study Materials and Method : Upper gastrointestinal study wa

  • PDF

A Study on the Lung Nodule Detection in Digital Radiographic Images (디지탈 래디오 그래피 영상에서의 흉부 노듈 검출에 관한 연구)

  • 고석빈;김종효
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.1
    • /
    • pp.1-10
    • /
    • 1989
  • An automatic lung nodule detection algorithm was applied for digital radiographic images using Bit Slice Processor. In this algorithm, signal enhancing filtering and signal suppressing filtering were performed on the given digital chest image, respectively. Then we grit the dirt- frrence image from these filtered images, and hi-level island images were obtained by applying various threshold values. From the island images, we decided the suspicious nodules using size and circularity test, and marked them to alert radiologists. The performance of the atgorithm was analyzed with respect to the size, contrast and position of digitally synthesized nodules. This method presented 45.8% of true positive ratio for the nodules of lOw in diameter with 12-16 pixel value differnces.

  • PDF

Segmentation of Welding Defects using Level Set Methods

  • Mohammed, Halimi;Naim, Ramou
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.1001-1008
    • /
    • 2012
  • Non-destructive testing (NDT) is a technique used in science and industry to evaluate the properties of a material without causing damage. In this paper we propose a method for segmenting radiographic images of welding in order to extract the welding defects which may occur during the welding process. We study different methods of level set and choose the model adapted to our application. The methods presented here take the property of local segmentation geodesic active contours and have the ability to change the topology automatically. The computation time is considerably reduced after taking into account a new level set function which eliminates the re-initialization procedure. Satisfactory results are obtained after applying this algorithm both on synthetic and real images.

Apexogenesis and revascularization treatment procedures for two traumatized immature permanent maxillary incisors: a case report

  • Forghani, Maryam;Parisay, Iman;Maghsoudlou, Amir
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.3
    • /
    • pp.178-181
    • /
    • 2013
  • Traumatic injuries to an immature permanent tooth may result in cessation of dentin deposition and root maturation. Endodontic treatment is often complicated in premature tooth with an uncertain prognosis. This article describes successful treatment of two traumatized maxillary central incisors with complicated crown fracture three months after trauma. The radiographic examination showed immature roots in maxillary central incisors of a 9-year-old boy with a radiolucent lesion adjacent to the right central incisor. Apexogenesis was performed for the left central incisor and revascularization treatment was considered for the right one. In 18-month clinical and radiographic follow-up both teeth were asymptomatic, roots continued to develop, and periapical radiolucency of the right central incisor healed. Considering the root development of these contralateral teeth it can be concluded that revascularization is an appropriate treatment method in immature necrotic teeth.

Dental radiology reporting status and recording frequency of reporting items in Korea

  • Jinwoo Choi
    • Imaging Science in Dentistry
    • /
    • v.53 no.1
    • /
    • pp.35-42
    • /
    • 2023
  • Purpose: This study investigated the current dental radiology reporting methods and the recording rate of 10 mandatory reporting items in Korea. Materials and Methods: An original online survey created using Google Forms was distributed to dental practitioners. The survey asked about the participants' age, experience, workplace, use of radiologic equipment, radiology reporting methods, and recording reporting items. Results: In total, 354 responses were analyzed. Radiologic reporting in dental charts was the most commonly used method for each modality. Four out of 10 mandatory items were recorded at a high rate, but the remaining 6 items had substantially lower recording rates, often below 50%. The participants who reported radiographic findings through other separate methods had higher item scores than those who wrote findings in dental charts(P<0.05). Conclusion: Radiologic societies and dental associations should encourage the use of separate reports for radiographic examinations. Education regarding radiology reports and the justification for reporting items should be reinforced in dental schools, training courses on radiology, and the continuing education curriculum.

Shape Reconstruction of Solder Joints on PCB using Iterative Reconstruction Technique (반복복원 기법을 이용한 전자회로기판의 납땜부 형상 복원)

  • 조영빈;권대갑
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.3
    • /
    • pp.353-362
    • /
    • 1999
  • This paper presents a shape reconstruction method for automatic inspection of the solder joints on PCBs using X-ray. Shape reconstruction from X-ray radiographic image has been very important since X-ray equipment was used for improving the reliability of inspection result. For this purpose there have been lots of previous works using tomography, which reconstructs the correct shape, laminography or tomosynthesis, which are very fast algorithm. Latter two methods show outstanding performance in cross-sectional image reconstruction of lead type component, but they are also known to show some fatal limitations to some kinds of components such as BGA, because of shadow effect. Although conventional tomography does not have any shadow effect, the shape of PCB prohibits it from being applied to shape reconstruction of solder joints on PCB. This paper shows that tomography using Iterative Reconstruction Technique(IRT) can be applied to this difficult problem without any limitations. This makes conventional radiographic instrument used for shape reconstruction without shadow effect. This means that the new method makes cost down and shadow-free shape reconstruction. To verify the effectiveness of IRT, we develop three dimensional model of BGA solder ball, make projection model to obtain X-ray projection data. and perform a simulation study of shape reconstruction. To compare the performance of IRT with that of conventional laminography or tomosynthesis, reconstruction data are reorganized and error analysis between the original model are also performed.

  • PDF

A Study on the Size of Lung by Radiographic Method in Normal Korean (정상(正常) 한국인(韓國人)의 폐야(肺野)크기에 대(對)한 조사연구(調査硏究))

  • Kim, Wha-Gon
    • Journal of radiological science and technology
    • /
    • v.1 no.1
    • /
    • pp.69-73
    • /
    • 1978
  • This study was conducted in order to determine width, length of lung by radiographic method. The measurements carried out on normal chest X-ray film of 1,036 persons who took the radiograph from the April of 1977 to the June of 1978. As a result of this study, the following conclusions were obtained: 1. In the case of male, the average width, and length of both side lung size from new birth to nineteen of age was larger than female with the exception of partly age group. 2. Lung size in average width at adult was from 27.60cm to 29.20cm and female was 25.10cm to 26.22cm. 3. The mean length of left lung at adult was from 26.32cm to 25.27cm in female. 4. The average length of right lung at adult was from 25.8cm to 28.35cm in male and female was from 24.86cm to 25.17cm. 5. It was found that lung sige in width and length was slightly increased until 39 years of age, but was trend to decrease it of lung in the age of 40 years old. 6. In the case of adult, the difference of the average length between right and left lung, the length of right lung was slightly shorter than left that.

  • PDF

COMPARATIVE STUDY OF TEMPOROMANDIBULAR JOINT RADIOGRAMS USING SOME RADIOGRAPHIC PROJECTIONS (촬영술식에 따른 악관절 방사선 사진상의 비교연구)

  • Kim kwang-In;Kim Han-Pyong
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.1
    • /
    • pp.65-72
    • /
    • 1991
  • For the enhancement of a comprehension in temporomandibular joint radiographs, the author has compared and analysed the roentgenographic images of the temporomandibular joint of human dry skull which was taken by submentovertex projection, panoramic radiography, oblique lateral transcranial projection, corrected anterio-posterior tomogram and corrected lateral tomogram. The obtained results were as follows. 1. The submentovertex projection represented in detail the both poles and the posterior surface of the condylar head of the mandible. 2. The oblique lateral transcranial projection represented the articular space, the outer contour of the condylar head and the position of the condylar head within the mandibular fossa, but the relationship of the temporomandibular joint was not revealed accurate, because of the oblique direction of a central ray in taking radiographs. 3. The corrected antero-posterior tomogram was superior method in representation of roent- genographic images of the superior surface and the both poles of the condylar head and the corrected lateral tomogram was considered as the most accurate method among some radiographic techniques for the interpretation of articular space and condyle-fossa relationship. 4. It was possible to observe three-dimensionally the head of condyle with the combinated use of submentovertex projection, corrected antero-posterior tomogram and corrected lateral tomogram.

  • PDF