• Title/Summary/Keyword: Radiographic film

Search Result 122, Processing Time 0.025 seconds

Odontogenic myxoma: a case report with recent image modalities

  • Kim Jae-Duk;Kim Kwang-Won;Lim Sung-Hoon
    • Imaging Science in Dentistry
    • /
    • v.34 no.4
    • /
    • pp.199-202
    • /
    • 2004
  • The odontogenic myxoma is an benign, slow growing neoplasm which is of ectomesenchymal origin. This neoplasm occurs almost exclusively in the jaw bones and comprises 0.2% to 17.7% of odontogenic tumors. The odontogenic myxoma may show a wide spectrum of radiographic appearances, unilocular, multilocular radiolucency and a distinct or diffuse border, making the differential diagnosis difficult. We present a case of the odontogenic myxoma in the maxilla with conventional and recent image modalities. Occlusal film revealed a medially extended multilocular lesion with intralesional fine and straight trabeculations from the scalloped margin and buccal expansion and thinning of cortical bone. Computed tomogram revealed lesion showed equivalent density to the muscles in the left maxillary sinus with partial cortical discontinuity of medial wall and the tennis-racket pattern with internal straight trabeculations. MRI revealed intermediate signal intensity on Tl weighted image and high signal intensity on T2 weighted image. In Gd enhanced MR image, the peripheral portions of the lesion were enhanced.

  • PDF

A Study on Real-Time Corrosion Thickness Measurement Technique of Insulated Pipeline (보온재 부착 파이프라인의 부식두께 측정에 관한 연구)

  • Jang, Ji-Hun;Jo, Gyeong-Sik;Lee, Jong-O;Kim, Gi-Dong
    • 연구논문집
    • /
    • s.31
    • /
    • pp.135-147
    • /
    • 2001
  • The wall-thickness of insulated pipelines can be easily evaluated by measuring the gamma-ray transmission intensity because this intensity is inversely proportional to the thickness of insulated pipeline. The main purpose of this study is to develop the nondestructive and filmless on-line inspection system of corrosion by measuring the wall thickness of insulated pipeline. The inspection system is constructed with radioisotope, 64 channel photo diode array detector, crawler system and data taking and operating software. The traditional off-line radiographic method carried out by exposing film cassettes can be replaced by this cost-effective on-line digital imaging method and the application will be greatly expected especially in the chemical and petrochemical industries.

  • PDF

A RADIOGRAPHIC STUDY ON THE MORPHOLOGY OF THE MAXILLARY SINUS (상악동의 형태에 관한 방사선학적 연구)

  • Kim Bong-Young;Kim Jae Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.2
    • /
    • pp.297-306
    • /
    • 1991
  • The purpose of this study is to improve the availabilities of radiographic technics as diagnostic methods to evaluate maxillary sinus in dental clinic. For the morphologic study of maxillary sinus, 20 dry maxillas were used and intraoral standard views, orthopantomograms, and skull P-A views were taken. For measuring the vertical image magnification rates, 5 sites in maxillary molar regions of 5 dry mandibles were selected radndomly and 25 wires of the determined sizes for selected portions were attached to the sites, after then, intraoral radiograms with bisecting technic and orthopantomograms were taken. The acquired results were as follows: 1. The anterior extension of the maxillary sinus on orthopantomogram was the distal side of the canine in 45.45% of subjects, the mesial side of the canine in 27.27%, the lateral incisor in 9.09%, the mesial side of the 1st premolar in 9.09%, and the mesial side of the 2nd pre-molar in 9.09%. 2. The positional relationship between the floor of maxillary sinus and the apex of alveolar socket revealed superimposed type in 58.3% of subjects, approached type in 33.3%, and separated type in 8.4%. 3. The morphology of inferior border of maxillary sinus was simple V or U shape in edentulous stage and V or wide U shape in alveolar socket stage. 4. The vertical image length on intraoral film taken by bisecting technic was magnified by 27.23% on the average and the length on orthopantomogram by 12.35%. 5. The inferior borders of maxillary sinus coinciding with each of the areas bearing the anterior and the posterior teeth on skull P-A view were determined.

  • PDF

A Study on Radiographic Equipments and Situation for the Chest (흉부(胸部)의 X선촬영(線撮影) 및 촬영장치(撮影裝置) 현황(現況)에 관(關)한 조사(調査))

  • Ko, Shin-Gwan;An, Bong-Seon
    • Journal of radiological science and technology
    • /
    • v.8 no.2
    • /
    • pp.3-9
    • /
    • 1985
  • From the study on the chest radiologic equipments and situations of university hospitals, general hospitals, and radiologic clinics located in Seoul area and Choong-cheong province, the author got conclusions as follows : 1. The rectfication methods of the equipments were employing mainly single or three-phase full wave, and 78% of the examined were using single phase full wave. 2. The focal sizes in case of small focus were less than 1.0mm in chest-only use, and more than 1.0mm in 81% of combined use. The focal sizes in case of large focus were more than 1.6mm in 78% of the total. 3. Maximum ratings of x-ray tubes were 47% at 125 kVp maximum tube voltage and 41% at 150kVp. The maximum tube currentes higher than 500mA were shown in 72% of all the examined. And the maximum exposure time was the range of 5-8sec. 4. Grid was not used in the 66% of all the hospitals. Equipment for chest-only was employing 10:1 grid ratio and the 2.0-2.9mmAl of total filtration formed 38% of all the examined. 5. In the processing time of exposed film, 68% of all was 90sec, and only 20% of all the examined used optimum developing temperature according to this condition. 6. In the radiographic conditions, more than 50% used low tube voltages lower than 70 kVp and only 3% of all the equipments used high tube voltages higher than 100 kVp. The 46.9% of all the equipments 300mA, and 53% of all used shorter exposure time less than 1/20(0.05) sec. 7. In the monthly average number of radiographs, 44% of all was x-ray the radiographs.

  • PDF

AN EXPERIMENTAL EXAMINATION OF MULTIMODAL IMAGING SYSTEM FOR IMPLANT SITE ASSESSMENT (인공치아 이식부위 분석을 위한 다기능 영상체계의 실험적 검사)

  • Park Chang-Seo;Kim Kee-Deog
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.1
    • /
    • pp.7-16
    • /
    • 1998
  • The Scanora/sup (R)/ X-ray unit uses the principles of narrow beam radiography and spiral tomography. Starting with a panoramic overview as a scout image. multiple tomographic projections could be selected. This study evaluated the accuracy of spiral tomography in comparison to routine panoramic radiography for dental implant treatment planning. An experimental study was performed on a cadaver mandible to assess the accuracy of panoramic radiography and spiral tomography film images for measurement of metallic spheres. After radiographic images of the metallic spheres on the surgical stent were measured and corrected for a fixed magnification of radiographic images. following results were obtained. 1. In the optimal position of the mandible. the minimal horizontal and vertical distortion was evident in the panoramic radiography images. The mean horizontal and vertical magnification error in anterior sites was 5.25% and 0.75%. respectively. The mean horizontal and vertical magnification error in posterior sites was 0.50% and 1.50%. respectively. 2. In the displaced forward or in an eccentric position of the mandible. the magnification error of the panoramic radiography images increased significantly over the optimal position. Overall, the mean horizontal magnification error of the anterior site in the different positions changed dramatically within a range of -17.25% to 39.00%, compared to the posterior range of -5.25% to 8.50%. However, the mean vertical magnification error stayed with the range of 0.5% to 3.75% for all the mandibular positions. 3. The magnification effects in the tomographic scans were nearly identical for the anterior and posterior with a range of 2.00% to 5.75% in the horizontal and 4.50% to 5.50% in the vertical dimension, respectively. 4. A statistically significant difference between the anterior and posterior measurements was found in the horizontal measurements of the panoramic radiography images of the displaced forward and backward position of the mandible(P<0.05). Also a significant difference between the optimal panoramic and tomographic projections was found only in the vertical measurement(P<0.05).

  • PDF

The Effects of the Mixture of Fetal Bovine Serum and Poly-glycolic acid in Rabbit Calvarial Model (Poly-glycolic Acid(PGA)와 우태아 혈청(Fetal bovine serum, FBS)의 혼합물이 가토에서 골형성에 미치는 영향)

  • Sung, Yong Duck;Kim, Yong Ha;Moon, Young Mi;Kim, Kap Joong;Kim, Yeon Jung;Choi, Sik Young
    • Archives of Plastic Surgery
    • /
    • v.34 no.3
    • /
    • pp.298-304
    • /
    • 2007
  • Purpose: This study was undertaken to investigate the osteogenic induction potential of PGA & FBS mixture on a calvarial defect in the rabbit. Methods: Twenty New zealand white rabbit, weighing from 3.5-4kg were allocated into each of the three groups. Four 8 mm sized bone defects were made on the parietal bone by drilling. In group I, the bony defects were implanted with $50{\mu}m$ thickness film containing mixture of PGA and FBS. In group II, with PGA only film, & in group III, the bony defects were left with no implants. Results were evaluated by using morphologic change, radiographic study, biochemical study and histologic examination at 1 week (group I n=7, group II n=7, group III n=14), 2 weeks (group I n=6, group II n=6, group III n=12) and 3 weeks (group I n=7, group II n=7, group III n=14) following implantation. Results: In the morphologic & radiographic study, the formation and corticalization of callus were observed earlier in group I than in groups II and III (p < 0.05). In histological examination, group I showed more abundant and faster new bone formation than in group II and III. In biochemical analysis, group I displayed more activity than in group II and III. Group I also showed more abundant osteopontin, osteocalcin than groups II and III. Conclusion: In conclusion, the results demonstrate that the mixture of PGA and FBS has an effect on osteoblastic formation in the rabbit model. It is considered that further evaluation of long term results on resorption, immunologic tissue reaction and response of applied mixture in the human model will be needed.

Patient dose in adult and pediatric dental panoramic radiography in Korea (성인과 소아에서 치과 파노라마방사선검사의 환자선량)

  • Kim, Eun-Kyung;Han, Won-Jeong;Kim, Kyoung-A;Lee, Wan;Yoon, Suk-Ja;Hwang, Eui-Hwan;Kim, Gyu-Tae;Heo, Min-Suk;An, Chang-Hyeon;An, Seo-Young;Han, Jin-Woo;Jung, Yun-Hoa
    • The Journal of the Korean dental association
    • /
    • v.55 no.8
    • /
    • pp.516-526
    • /
    • 2017
  • Objective: To suggest diagnostic reference levels (DRLs) for dental panoramic radiography in adults and children through the nationwide survey in Korea. Materials and Methods: Two hundred twelve dental institutions on a national basis were visited. The radiographic examination protocols were surveyed and their patient doses at the clinical exposure setting for adult and children (5- and 10-year old) were measured at 244 panoramic radiographic equipment. The measured DAP were analyzed and compared according to age group, the size of hospital, the type of radiographic system, the installation duration of equipment. Results: The mean exposure parameters were 70.1 kV, 9.2 mA, 14.4 second for adult and 66.6 kV, 7.9 mA, 13.8 second for 10-year old child and 65.5 kV, 7.3 mA, 13.7 second for 5-year old child. The mean and third quartile patient DAPs were $138.3mGy\;cm^2$ and $151.0mGy\;cm^2$ for adult, $99.5mGy\;cm^2$ and $104.8mGy\;cm^2$ for 10-year old child and $89.5mGy\;cm^2$ and $95.5mGy\;cm^2$ for 5-year old child. The mean patient dose at the university dental hospital was lower than that at the dental clinic (p<0.05). The mean patient dose of direct digital radiography type was higher than that of film-based type. However, the difference did not show statistically significance. Conclusion: DRLs for dental panoramic radiography in adult, 10- and 5-year old child were suggested to be $151mGy\;cm^2$, $105mGy\;cm^2$, and $96mGy\;cm^2$ in Korea based on this nationwide survey.

  • PDF

A comparison of subtracted images from dental subtraction programs (디지털공제프로그램간의 디지털공제영상 비교)

  • Han Won-Jeong
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.147-151
    • /
    • 2002
  • Purpose: To compare the standard deviation of gray levels on digital subtracted images obtained by different dental subtraction programs. Materials and Methods: Paired periapical films were taken at the lower premolar and molar areas of the phantoms involving human mandible. The bite registration group used Rinn XCP equipment and bite registration material, based on polyvinyl siloxane, for standardization. The no bite registration group used only Rinn XCP equipment. The periapical film images were digitized at 1200 dpi resolution and 256 gray levels by a flat bed scanner with transparency unit. Dental digital subtraction programs used for this study were Subtractor (Biomedisys Co., Korea) and Emago (Oral Diagnostic Systems, The Netherlands). To measure the similarities between the subtracted images, the standard deviations of the gray levels were obtained using a histogram of subtracted images, which were then analyzed statistically. Results: Subtracted images obtained by using the Emago program without manual selection of corresponding points showed the lowest standard deviation of gray levels (p<0.01). And the standard deviation of gray levels was lower in subtracted images in the group of a bite registration than in the group of no use of bite registration (p < 0.01). Conclusion: Digital radiographic subtraction without manual selection of reference points was found to be a convenient and superior method.

  • PDF

The Experiment of Grid Characteristics for High-voltage Radiography of Chest (흉부촬영시 관전압과 선질에 따른 적절한 격자의 선택을 위한 실험)

  • Kim, Jung-Min;Ahn, Bong-Seon
    • Journal of radiological science and technology
    • /
    • v.15 no.2
    • /
    • pp.31-36
    • /
    • 1992
  • Grids can improve the diagnostic quality of chest radiography by trapping the greater part of scattered radiation thus providing more detailed. chest radiographic images. It is most effective mathod of reduce the scatter ratio but must increase the expour factor. The benefit of use of grid is improve the contrast and the loss is increase of patient dose. In chest radiography especially hard quality high voltage radiography it will have to be considered to select the optimum grid with view point of benefit and loss. In this experiment, author got some result of characteristics about 4 different grids with film method. 1. There was no difference the scatter ratio in case of no grid and the scatter ratio was about 60%. 2. 16 : 1 grid was excellent of scatter reduction factor in high voltage chest radiography, next was 10 : 1, CROSS, MICRO FINE grid have low scatter reduction rate compare to 16:1, 10:1 grid. 3. The bucky factor of CROSS grid in accordance of kVp was find out the highest in 4 grids, on the contraly 10 : 1 grid was profitable to the exposure does. 4. With careful consideration in the point of scatter reducion rate and bucky factor, author suggest the 10 : 1 linear grid on the use of chest radiography in $80{\sim}120\;kVp$, 16 : 1 grid in $120{\sim}140\;kVp$.

  • PDF

Monte Carlo Simulation of Small Photon Beam Measurements by Beam Intensity Scanner System(BISS)

  • Park, Kwangyl;Vahc, Young-Woo;Ohyun Kwon;Park, Kyung-Ran;Lee, Yong-Ha;Yi, Byung-Yong;Kim, Sookil
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.282-284
    • /
    • 2002
  • We have developed and used BISS as a radiation detector to verify patient dose and determine the physical characteristics of beams used in Stereotatic Radio Surgery(SRS) and Intensity Modulated Radiation Therapy(IMRT). In order to confirm the function and accuracy of our BISS, we simulate our measurements by BISS under the radiation of 6MV photons from a Varian Clinac 21EX equipped with a 60 leaf pairs MLC. For the simulation based on the Monte Carlo algorithm, which remains the most comprehensive and accurate theoretical method to verify beam profiles, we use the BEAM code. Compared with the measurements by BISS, our simulation of variously shaped phantom measurements show good agreements. Our simulation results can be used as a theoretical standard to compare and confirm measurements by BISS and other dosimeters such as ultramicro cylindrical ionization chamber(UCIC) and radiographic film.

  • PDF