• Title/Summary/Keyword: Radiographic film

Search Result 122, Processing Time 0.023 seconds

Treatment of Lateral Malleolar Fractures with Cannulated Screws in Danis-Weber type B Ankle Fractures (Danis-Weber B형 족근 관절 골절에 있어 유경 나사를 이용한 비골 외 과 골절의 치료)

  • Park, Yong-Wook;Chung, Yung-Khee;Yoo, Jung-Han;Park, Hong-Jun;Yu, Sun-O;Kang, Ki-Man
    • Journal of Korean Foot and Ankle Society
    • /
    • v.5 no.2
    • /
    • pp.129-135
    • /
    • 2001
  • Purpose: To evaluate the radiographic results of the treatment for Danis-Weber type B lateral malleolar fracture with 2 cannulated screws. Materials and Methods: Thirty-four cases of Danis-Weber type B lateral malleolar fracture were available. Follow-up averaged 8 months (6-25 months). The medial clear space for lateral displacement of talus, talo-crural angle for lateral malleolar shortening, and malunion evidence of lateral malleolar fracture were observed. Results: Medial clear space was from 2mm to 4mm in 34 cases. Talo-crural angle was from $73^{\circ}$ to $82.5^{\circ}$ in 33 cases. One case was complicated with malunion of lateral malleolus. But, we found the same condition in the immediate post- operative radiographic film. Conclusion: We believe that the 2 cannulated screws fixation for Danis-Weber type B lateral malleolar simple fractures is an excellent treatment method.

  • PDF

A Study on the Chest Radiographic Condition in Adult. (흉부X-선(胸部X-線) 촬영조건(撮影條件)에 대(對)한 고찰(考察))

  • Lee, Sang-Suk;Youn, Chul-Ho;Joo, Kuang-Tai;Park, Sung-Ock
    • Journal of radiological science and technology
    • /
    • v.2 no.1
    • /
    • pp.31-35
    • /
    • 1979
  • A thorax is consisted of a heart, great vesseles, lungs, ribs, sternum and thoracic spine etc. The quality of chest radiogram is very important in order to find out abnormality in the lung field. The image has two major characteristics; density and contrast which directly influence the diagnostic quality of the roentgenogram. It is very hard to make excellent film image in the lung field because of overlapping bones and other soft tissues. To take a good radiogram of lung field, we studied the condition of chest P-A projection in adult and obtained results as follows: 1. The average chest radiographic condition is resulted as 62KVP, 16 mAs in hospitals around Kyung Ki-Do, Korea, 2. The density of the chest 20cm in thickness, is equal to the water phantom 8cm in thickness. 3. The best quality of chest radiogram is achieved in the condition of the lung field at 100KVP, 9.6mAs by use of Grid 8:1.

  • PDF

Development of Image Quality Evaluation Program for Digital Diagnostic Radiography (디지털진단의료영상 화질평가 프로그램 개발)

  • Kang, Bo-Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.2
    • /
    • pp.5-10
    • /
    • 2008
  • Most of the diagnostic medical radiography are rapidly replaced by digital imaging systems recently. Although with the current transition of analog to digital most of the exposure conditions and parameters are still on the basis of film-screen analog system. Moreover the evaluation of acquired digital radiographic image is not fulfilled normally because of the difficulties in handling the digital raw data. The user friendly windows program for the evaluations of digital radiographic image was developed on the MatLab platform. The program has functions for the calculation of the contrast profile, NPS(noise power spectrum), MTF(modulation transfer function), and NEQ(noise equivalent quanta).

  • PDF

A Study on the Size of Lung by Radiographic Method in Normal Korean (정상(正常) 한국인(韓國人)의 폐야(肺野)크기에 대(對)한 조사연구(調査硏究))

  • Kim, Wha-Gon
    • Journal of radiological science and technology
    • /
    • v.1 no.1
    • /
    • pp.69-73
    • /
    • 1978
  • This study was conducted in order to determine width, length of lung by radiographic method. The measurements carried out on normal chest X-ray film of 1,036 persons who took the radiograph from the April of 1977 to the June of 1978. As a result of this study, the following conclusions were obtained: 1. In the case of male, the average width, and length of both side lung size from new birth to nineteen of age was larger than female with the exception of partly age group. 2. Lung size in average width at adult was from 27.60cm to 29.20cm and female was 25.10cm to 26.22cm. 3. The mean length of left lung at adult was from 26.32cm to 25.27cm in female. 4. The average length of right lung at adult was from 25.8cm to 28.35cm in male and female was from 24.86cm to 25.17cm. 5. It was found that lung sige in width and length was slightly increased until 39 years of age, but was trend to decrease it of lung in the age of 40 years old. 6. In the case of adult, the difference of the average length between right and left lung, the length of right lung was slightly shorter than left that.

  • PDF

Common positioning errors in panoramic radiography: A review

  • Rondon, Rafael Henrique Nunes;Pereira, Yamba Carla Lara;do Nascimento, Glauce Crivelaro
    • Imaging Science in Dentistry
    • /
    • v.44 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Professionals performing radiographic examinations are responsible for maintaining optimal image quality for accurate diagnoses. These professionals must competently execute techniques such as film manipulation and processing to minimize patient exposure to radiation. Improper performance by the professional and/or patient may result in a radiographic image of unsatisfactory quality that can also lead to a misdiagnosis and the development of an inadequate treatment plan. Currently, the most commonly performed extraoral examination is panoramic radiography. The invention of panoramic radiography has resulted in improvements in image quality with decreased exposure to radiation and at a low cost. However, this technique requires careful, accurate positioning of the patient's teeth and surrounding maxillofacial bone structure within the focal trough. Therefore, we reviewed the literature for the most common types of positioning errors in panoramic radiography to suggest the correct techniques. We would also discuss how to determine if the most common positioning errors occurred in panoramic radiography, such as in the positioning of the patient's head, tongue, chin, or body.

Methods on Simple Radiography of Impingement Syndrome in Shoulder Joint (견관절 충돌증후군의 단순X선촬영 방법에 대한 검토)

  • Kweon, Dae-Cheol;Kim, Moon-Sun;Kim, Yong-Seob;Chung, Kyung-Mo
    • Journal of radiological science and technology
    • /
    • v.23 no.1
    • /
    • pp.21-27
    • /
    • 2000
  • To evaluation of patients who have shoulder impingement syndrome is by diagnostic radiography. Shoulder impingement is a problem which occurs in young, active individuals as well as older individuals. In fact, the pain is probably caused by repetitive stress placed on the shoulder joint either through recreational activities of your occupation. Impingement series approach to radiographic examination of the shoulder is take five projections. First anteroposterior oblique projection. Second standard anteroposterior projection. Third superoinferior axial projection. Fourth supraspinatus outlet projection offers a view of the outlet of the supraspinatus tendon unit as it passes under the coraacromial arch. Fifth anteroposterior $30^{\circ}$ caudal projection will adequately demonstrate the anterior acromial spur or ossification in the coraacromial ligament and more reliable to demonstrate spurring of the anterior acromion than supraspinatus outlet projection. This decreased the need for additional radiographic veiws, reduces the patient's exposure to x - ray radiation and decreases use of film. This can lower the cost of the evaluation and improve patient satisfaction.

  • PDF

Diagnostic reference levels in intraoral dental radiography in Korea

  • Kim, Eun-Kyung;Han, Won-Jeong;Choi, Jin-Woo;Jung, Yun-Hoa;Yoon, Suk-Ja;Lee, Jae-Seo
    • Imaging Science in Dentistry
    • /
    • v.42 no.4
    • /
    • pp.237-242
    • /
    • 2012
  • Purpose: The objectives of this study were to survey the radiographic exposure parameters, to measure the patient doses for intraoral dental radiography nationwide, and thus to establish the diagnostic reference levels (DRLs) in intraoral dental X-ray examination in Korea. Materials and Methods: One hundred two intraoral dental radiographic machines from all regions of South Korea were selected for this study. Radiographic exposure parameters, size of hospital, type of image receptor system, installation duration of machine, and type of dental X-ray machine were documented. Patient entrance doses (PED) and dose-area products (DAP) were measured three times at the end of the exit cone of the X-ray unit with a DAP meter (DIAMENTOR M4-KDK, PTW, Freiburg, Germany) for adult mandibular molar intraoral dental radiography, and corrections were made for room temperature and pressure. Measured PED and DAP were averaged and compared according to the size of hospital, type of image receptor system, installation duration, and type of dental X-ray machine. Results: The mean exposure parameters were 62.6 kVp, 7.9 mA, and 0.5 second for adult mandibular molar intraoral dental radiography. The mean patient dose was 2.11 mGy (PED) and 59.4 $mGycm^2$ (DAP) and the third quartile one 3.07 mGy (PED) and 87.4 $mGycm^2$ (DAP). Doses at university dental hospitals were lower than those at dental clinics (p<0.05). Doses of digital radiography (DR) type were lower than those of film-based type (p<0.05). Conclusion: We recommend 3.1 mGy (PED), 87.4 $mGycm^2$ (DAP) as the DRLs in adult mandibular molar intraoral dental radiography in Korea.

Roentgenological Evaluation of Radiographic position of the Chest (흉부촬영(胸部撮影)에 있어 환자자세(患者姿勢)에 관(關)한 영향(影響))

  • Shin, Gwi-Soon;Kim, Young-Hwan;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.2 no.1
    • /
    • pp.59-69
    • /
    • 1979
  • For the clearer visualization of the lung apices in the routine chest P-A view, we have analysed the films at the different positions and different directions of the central X-ray beams. The brief results are as the follows. 1. Best visualization of the lung apices are made with the following position of the patient and central ray. Central ray is directed to the median sagittal plane at the level of the 5th thoracic vertebra with the palms of the hands placing at the greater trochanteric area of the both femurs. 2. The position of the sterno-clavicular joint shows no alteration between the radiographs with the central beam to the film center and to the 5th thoracic vertebra, and position of the hands at the greater trochanters or iliac crests. 3. No relationship exists between the center of the film and the position of the hand. The central beam is projected more inferiorly when the beam is centered to the film center than to the 5th thoracic vertebra. 4. The scapulae are rotated sufficiently anteriorly and more inferiorly, with placing the palms at the greater trochanters, directing central ray to the 5th thoracic vertebra, and with close contact the lung apices to the cassette.

  • PDF

Consideration of density matching technique of the plate type direct radiologic image system and the conventional X-ray film;first step for the subtraction (Ektaspeed plus 필름을 이용한 일반 방사선시스템과 Digora를 이용한 디지탈 영상시스템의 밀도변화 비교연구)

  • So, Sung-Soo;Noh, Hyeun-Soo;Kim, Chang-Sung;Choi, Seong-Ho;Kim, Kee-Deog;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.1
    • /
    • pp.199-211
    • /
    • 2002
  • Digital substraction technique and computer-assisted densitometirc analysis detect minor change in bone density and thus increase the diagnostic accuracy. This advantage as well as high sensitivity and objectivity which precludes human bias have drawn interest in radiologic research area. The objectives of this study are to verify if Radiographic density can be recognized in linear pattern when density profile of standard periapical radiograph with the aluminium stepwedge as the reference, was investigated under varies circumstances which can be encountered in clinical situations, and in addition to that to obtain mutual relationship between the existing standard radiographic system, and future digital image systems, by confirming the corelationship between the standard radiograph and Digora system which is a digital image system currently being used. In order to make quantitative analysis of the bone tissue, digital image system which uses high resolution automatic slide scanner as an input device, and Digora system were compared and analyzed using multifunctional program, Brain3dsp. The following conclusions were obtained. 1. Under common clinical situation that is 70kVp, 0.2 sec., and focal distance 10cm, Al-Equivalent image equation was found to be Y=11.21X+46.62 $r^2=0.9898$ in standard radiographic system, and Y=12.68X+74.59, $r^2=0.9528$ in Digora system, and linear relation was confirmed in both the systems. 2. In standard radiographic system, when all conditions were maintained the same except for the condition of developing solution, Al-Equivalent image equation was Y=10.07X+41.64, $r^2=0.9861$ which shows high corelationship. 3. When all conditions were maintained the same except for the Kilovoltage peak, linear relationship was still maintained under 60kVp, and Al-Equivalent image equation was Y=14.60X+68.86, $r^2=0.9886$ in the standard radiograhic system, and Y=13.90X+80.68, $r^2=0.9238$ in Digora system. 4. When all conditions were maintained the same except for the exposure time which was varied from 0.01 sec. to 0.8 sec., Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9188 to 0.9900, and in general, standard radiographic system showed higher R-square than Digora system. 5. When all conditions were maintained the same except for the focal distance which was varied from 5cm to 30cm, Al-Equivalent image equation was found to be linear in both the standard radiographic system and Digora system. The R-square was distributed from 0.9463 to 0.9925, and the standard radiographic system had the tendency to show higher R-square in shorter focal distances.

Comparison of the Rate of Error with the Bisecting Angle Technique and the Paralleling Technique (등각촬영법과 평행촬영법에 따른 실책율 비교)

  • Lee, Yeong-Ae;Jo, Min-jung
    • Journal of dental hygiene science
    • /
    • v.4 no.3
    • /
    • pp.97-102
    • /
    • 2004
  • In order to find out the rate of error according to intraoral standard radiographic techniques, this study analyzed 3,251 standard films, and conducted a questionnaire with 120 Daegu Health College students who have used the bisecting angle technique and the paralleling technique. Followed are the results of the study: 1. The rate of error was the highest in canine from both maxilla and mandible when used by the bisecting angle technique. 2. The rate of error was the highest in premolar from both maxilla and mandible when used by the paralleling technique. 3. The technical error was occurred most frequently in elongation. 4. The rate of error and distortion was higher in the bisecting angle technique than in the paralleling technique. 5. The processing error was occurred most frequently in light film. 6. In applying radiographic techniques, the subjects indicated that the vertical angulation of central radiation in the bisecting angle technique and the oral fixation of film holder in the paralleling technique were the most difficult.

  • PDF