• Title/Summary/Keyword: Radiofrequency energy

Search Result 39, Processing Time 0.02 seconds

The Effect of using Gamma Titanium RF Electrodes on the Ablation Volume during the Radiofrequency Ablation Process

  • Mohammed S. Ahmed;Mohamed Tarek El-Wakad;Mohammed A. Hassan
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.2
    • /
    • pp.183-192
    • /
    • 2023
  • Radiofrequency ablation (RFA) is an alternative treatment for liver cancer to the surgical intervention preferred by surgeons. However, the main challenge remains the use of RF for the ablation of large tumours (i.e., tumours with a diameter of >3 cm). For large tumours, RFA takes a large duration in the ablation process compared with surgery, which increases patient pain. Therefore, RFA for large tumours is not preferred by surgeons. The currently materials used in RF electrodes, such as the nickeltitanium alloy (nitinol), are characterized by low thermal and electrical conductivities. On the other hand, the use of materials that have high thermal and electrical conductivities, such as titanium aluminide alloy (gamma titanium), produces more thermal energy for tumours. In this paper, we developed a cool-tip RF electrode model that uses nickel-titanium alloy and replaced it with titanium aluminide alloy by using the finite element model (FEM). The aim of this paper is to study the effect of the thermal and electrical conductivities of gamma titanium on the ablation volume. Results showed that the proposed design of the electrode increased the ablation rate by 1 cm3 /minute and 6.3 cm3/10 minutes, with a decrease in the required time ablation. Finally, the proposed model reduces the ablation time and damages healthy tissue while increasing the ablation volume from 22.5% cm3 to 62.5% cm3 in ten minutes compared to recent studies.

Comparison of Ablation Performance between Octopus Multipurpose Electrode and Conventional Octopus Electrode

  • Sae-Jin Park;Jae Hyun Kim;Jeong Hee Yoon;Jeong Min Lee
    • Korean Journal of Radiology
    • /
    • v.24 no.2
    • /
    • pp.86-94
    • /
    • 2023
  • Objective: To compare Octopus multipurpose (MP) electrodes, which are capable of saline instillation and direct tissue temperature measurement, and conventional electrodes for radiofrequency ablation (RFA) in porcine livers in vivo. Materials and Methods: Sixteen pigs were used in this study. In the first experiment, RFA was performed in the liver for 6 minutes using Octopus MP electrodes (n = 15 ablation zones) and conventional electrodes (n = 12 ablation zones) to investigate the effect of saline instillation. The ablation energy, electrical impedance, and ablation volume of the two electrodes were compared. In the second experiment, RFA was performed near the gallbladder (GB) and colon using Octopus MP electrodes (n = 12 ablation zones for each) with direct tissue temperature monitoring and conventional electrodes (n = 11 ablation zones for each). RFA was discontinued when the temperature increased to > 60℃ in the Octopus MP electrode group, whereas RFA was performed for a total of 6 minutes in the conventional electrode group. Thermal injury was assessed and compared between the two groups by pathological examination. Results: In the first experiment, the ablation volume and total energy delivered in the Octopus MP electrode group were significantly larger than those in the conventional electrode group (15.7 ± 4.26 cm3 vs. 12.5 ± 2.14 cm3, p = 0.027; 5.48 ± 0.49 Kcal vs. 5.04 ± 0.49 Kcal, p = 0.029). In the second experiment, thermal injury to the GB and colon was less frequently noted in the Octopus MP electrode group than that in the conventional electrode group (16.7% [2/12] vs. 90.9% [10/11] for GB and 8.3% [1/12] vs. 90.9% [10/11] for colon, p < 0.001 for all). The total energy delivered around the GB (2.65 ± 1.07 Kcal vs. 5.04 ± 0.66 Kcal) and colon (2.58 ± 0.57 Kcal vs. 5.17 ± 0.90 Kcal) were significantly lower in the Octopus MP electrode group than that in the conventional electrode group (p < 0.001 for all). Conclusion: RFA using the Octopus MP electrodes induced a larger ablation volume and resulted in less thermal injury to the adjacent organs compared with conventional electrodes.

Impact of Energy and Access Methods on Extrahepatic Tumor Spreading and the Ablation Zone: An Ex vivo Experiment Using a Subcapsular Tumor Model

  • Jin Sil Kim;Youngsun Ko;Hyeyoung Kwon;Minjeong Kim;Jeong Kyong Lee
    • Korean Journal of Radiology
    • /
    • v.20 no.4
    • /
    • pp.580-588
    • /
    • 2019
  • Objective: To evaluate the impact of energy and access methods on extrahepatic tumor spreading and the ablation zone in an ex vivo subcapsular tumor mimic model with a risk of extrahepatic tumor spreading. Materials and Methods: Forty-two tumor-mimics were created in bovine liver blocks by injecting a mixture of iodine contrast material just below the liver capsule. Radiofrequency (RF) ablations were performed using an electrode placed parallel or perpendicular to hepatic surface through the tumor mimic with low- and high-power protocols (groups 1 and 2, respectively). Computed tomography (CT) scans were performed before and after ablation. The presence of contrast leak on the hepatic surface on CT, size of ablation zone, and timing of the first roll-off and popping sound were compared between the groups. Results: With parallel access, one contrast leak in group 1 (1/10, 10%) and nine in group 2 (9/10, 90%) (p < 0.001) were identified on post-ablation CT. With perpendicular access, six contrast leaks were identified in each group (6/11, 54.5%). The first roll-off and popping sound were significantly delayed in group 1 irrespective of the access method (p = 0.002). No statistical difference in the size of the ablation zone of the liver specimen was observed between the two groups (p = 0.247). Conclusion: Low-power RF ablation with parallel access is proposed to be effective and safe from extrahepatic tumor spreading in RF ablation of a solid hepatic tumor in the subcapsular location. Perpendicular placement of an electrode to the capsule is associated with a risk of extrahepatic tumor spreading regardless of the power applied.

Radiofrequency Ablation Using a Separable Clustered Electrode for the Treatment of Hepatocellular Carcinomas: A Randomized Controlled Trial of a Dual-Switching Monopolar Mode Versus a Single-Switching Monopolar Mode

  • Jae Won Choi;Jeong Min Lee;Dong Ho Lee;Jung-Hwan Yoon;Yoon Jun Kim;Jeong-Hoon Lee;Su Jong Yu;Eun Ju Cho
    • Korean Journal of Radiology
    • /
    • v.22 no.2
    • /
    • pp.179-188
    • /
    • 2021
  • Objective: This study aimed to prospectively compare the efficacy, safety, and mid-term outcomes of dual-switching monopolar (DSM) radiofrequency ablation (RFA) to those of conventional single-switching monopolar (SSM) RFA in the treatment of hepatocellular carcinoma (HCC). Materials and Methods: This single-center, two-arm, parallel-group, randomized controlled study was approved by the Institutional Review Board. Written informed consent was obtained from all patients upon enrollment. A total of 80 patients with 94 HCC nodules were randomized into either the DSM-RFA group or SSM-RFA group in a 1:1 ratio, using a blocked randomization method (block size 2). The primary endpoint was the minimum diameter of the ablation zone per unit time. The secondary endpoints included other technical parameters, complication rate, technique efficacy, and 2-year clinical outcomes. Results: Significantly higher ablation energy per unit time was delivered to the DSM-RFA group than to the SSM-RFA group (1.7 ± 0.2 kcal/min vs. 1.2 ± 0.3 kcal/min; p < 0.001). However, no significant differences were observed between the two groups for the analyzed variables, including primary endpoint, regarding size of the ablation zone and ablation time. Major complication rates were 4.9% in the DSM-RFA group and 2.6% in the SSM-RFA group (p = 1.000). The 2-year local tumor progression (LTP) rates of the HCC nodules treated using DSM-RFA and SSM-RFA were 8.5% and 4.7%, respectively (p = 0.316). The 2-year LTP-free survival rates of patients in the DSM-RFA and SSM-RFA groups were 90.0% and 94.4%, respectively (p = 0.331), and the 2-year recurrence-free survival rates were 54.9% and 75.7%, respectively (p = 0.265). Conclusion: Although DSM-RFA using a separable clustered electrode delivers higher ablation energy than SSM-RFA, its effectiveness failed to show superiority over SSM-RFA in the treatment of HCC.

Mini Review: A Current Status of Microwave Susceptor Packaging (전자레인지 서셉터 패키징 기술개발 현황)

  • Lee, Wooseok;Choi, Jungwook;Song, Hyuk-Hwan;Ko, Seonghyuk
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.26 no.3
    • /
    • pp.133-138
    • /
    • 2020
  • As HMR (home meal replacement) food market grows rapidly, a new packaging with more HMR specialized functions is highly required to promote consumers' convenience. A susceptor is defined as a material generating heat by absorbing electromagnetic energy such typically as radiofrequency or microwave radiation. In microwave cooking, susceptors are made of conductive metal thin film deposited on paper or plastic sheet and have generally been used to help crispen or brown foods by converting microwave energy into heat. This mini review article deals with current status of microwave susceptor packaging including commercial products, technical theory, types of susceptor and a test method for heating performance.

Improvement of Optical and Electrical Properties of ITO/Ag/ITO Thin Films for Transparent Conducting Electrode (투명 전극 ITO/Ag/ITO 박막의 광학적 및 전기적 특성 향상 연구)

  • Shin, Yeon Bae;Kang, Dong-Won;Kim, Jeha
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.11
    • /
    • pp.740-744
    • /
    • 2017
  • Herein we studied the electrical and optical properties of indium tin oxide ITO/Ag/ITO multilayer thin films for application in transparent conducting electrodes. The ITO and Ag thin films were deposited onto soda lime glass (SLG) using radiofrequency and DC-sputtering methods, respectively. The as-synthesized ITO/Ag/ITO multilayer thin films were analyzed using 4-point probe, UV-Visible spectroscopy, and Hall measurement. We observed a rapid increase in electron concentration with increasing Ag thickness. However, electron mobility decreased with increasing Ag thickness. Finally, ITO/Ag/ITO multilayer thin films showed a characteristic low sheet resistance of $18{\Omega}/sq$ and high optical transmittance value (80%) with variation of Ag thickness (5~10 nm).

MR Imaging-Histopathologic Correlation of Radiofrequency Thermal Ablation Lesion in a Rabbit Liver Model: Observation during Acute and Chronic Stages

  • Jong Deok Lee;Jeong Min Lee;Sang Won Kim;Chong Soo Kim;Woo Sung Mun
    • Korean Journal of Radiology
    • /
    • v.2 no.3
    • /
    • pp.151-158
    • /
    • 2001
  • Objective: To determine the ability of MR imaging to detect the pathological changes occurring in radiofrequency (RF) thermal lesions and to assess its accuracy in revealing the extent of tissue necrosis. Materials and Methods: Using an RF electrode, thermal lesions were created in the livers of 18 rabbits. The procedure involved three phases. In the acute phase, six animals were killed the day after performing thermal ablation with RF energy, and two on day 3. In the subacute and chronic phases, eight rabbits underwent percutaneous hepatic RF ablation. After performing MR imaging, two animals were sacrificed at 1, 2, 4, and 7 weeks after the procedure, and MRpathologic correlation was performed. Results: In the acute phase, the thermal ablation lesions appeared at gross examination as well-circumscribed, necrotic areas, representing early change in the coagulative necrosis seen at microscopic examination. They were hypointense on T2-weighted images, and hyperintense on T1-weighted images. Gadolinium-enhanced MR imaging showed that a thin hyperemic rim surrounded the central coagulative necrosis. In the subacute phase, ablated lesions also showed extensive coagulative necrosis and marked inflammation at microscopic examination. Beyond two weeks, the lesions showed gradual resorption of the necrotic area, with a peripheral fibrovascular rim. The size of lesions measured by MR imaging correlated well with the findings at gross pathologic examination. Conclusion: MR imaging effectively demonstrates the histopathological tissue change occurring after thermal ablation, and accurately determines the extent of the target area.

  • PDF

A Study on the Permeation Properties of Permanent Gases and condensable Vapors through Hexamethyldisiloxane Plasma-Polymerized Membranes (Hexamethyldisiloxane 플라즈마 중합막을 통한 영구기체 및 응축성 증기의 투과특성에 관한 연구)

  • Oh, Sae-Joong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.699-706
    • /
    • 2018
  • The permeation properties of plasma polymer membranes were studied for permanent gases such as He, $H_2$, $O_2$, $N_2$, $CH_4$ and condensable vapors such as $CO_2$, $C_2H_4$, $C_3H_8$. The plasma polymers were prepared by the discharge of microwave or radiofrequency(RF) wave. Hexamethyldisiloxane (HMDS) vapor was used as a monomer for plasma polymerization. In HMDS plasma-polymerized membranes prepared under microwave discharge, the permeability coefficient was dependent of the kinetic molecular diameter of the permeate gases. Additionally the membranes showed higher $O_2/N_2$ permselectivity compared to the plasma polymers from radiofrequency discharge. On the contrary, in the HMDS plasma-polymerized membranes prepared under radiofrequency discharge, the permeability coefficient was dependent of the critical temperature of the permeant gases. The membranes showed high selectivities of $C_2H_4$ and $C_3H_8$ over $N_2$. The permeability coefficient of plasma polymerized membranes prepared under microwave discharge was dependent of the molecular diameter of permeant gases because of high crosslinking density of the membrane. However, the crosslinking density of the plasma polymerized membranes prepared under RF discharge was lower because the energy density of RF wave is weaker than that of microwave. Hence, the permeability of RF plasma polymerized membranes became dependent of the critical temperature rather than molecular diameter of the gases.

Radiofrequency thermal Shrinkage for Elongated Anterior Cruciate Ligament after Anterior Cruciate Ligament Reconstruction (전방십자인대 재건술 이후 이완된 전방십자인대에 시행한 고주파 에너지 열 수축)

  • Kim, Yeung-Jin;Chun, Churl-Hong;Kim, Tae-Kyun;Yang, Hwan-Deok;Kim, Hyoung-Joon;Kim, Young-Jin
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.7 no.1
    • /
    • pp.27-32
    • /
    • 2008
  • Purpose: To evaluate the clinical results of the patients who underwent radiofrequency thermal shrinkage (RFTS) for treatment of anterior cruciate ligament (ACL) laxity after ACL reconstruction. Material and Methods: From October 1999 to March 2006, we performed 133 cases of ACL reconstruction. Among them we experienced 16 patients who had the laxity of reconstructed ACL in second look arthroscopy. Mean follow-up was 20.4 months. Mean age was 33.5 years. 12 cases were male and 4 cases were female. The elongated ACL were treated by bipolar radiofrequency energy with an output of grade II. Subjective and objective parameters were utilized in analyses, such as: the mean range of motion, Lysholm knee score, Tegner activity score, Lachman test, IKDC score. Wilcoxon signed-rank test was used to perform the data analysis. P<0.05 was considered to be statistically significant. Results: Postoperative mean Lysholm knee score (preop: $82.2{\pm}5.2(77{\sim}85))$ (P=0.04), postop: $85.2{\pm}4.8$(82-90)) and anterior displacement by the Telos stress test (preop: $5.4{\pm}4.6(3{\sim}10)mm$, postop: $2.1{\pm}1.9(0{\sim}4)mm)$ (P=0.02), Lachman's test, and IKDC scores (P=0.04) demonstrated significant differences statistically compared to the preoperative. There were no statistical differences in mean range of motion, Tegner activity scale. Conclusions: Arthroscopic shrinkage for the ACL laxity after ACL reconstruction with radiofrequency device showed good clinical results and was applicable operative technique.

  • PDF

2018 심방세동 카테터 절제술 대한민국 진료지침: Part II

  • Yu, Hui-Tae;Jeong, Dong-Seop;Park, Hui-Nam;Park, Hyeong-Seop;Kim, Ju-Yeon;Kim, Jun;Lee, Jeong-Myeong;Kim, Gi-Hun;Yun, Nam-Sik;No, Seung-Yeong;O, Yong-Seok;Jo, Yeong-Jin;Shim, Jaemin
    • International Journal of Arrhythmia
    • /
    • v.19 no.3
    • /
    • pp.235-284
    • /
    • 2018
  • In this part the writing group will cover strategies, techniques, and endpoints of atrial fibrillation (AF) ablation. Prior to all, electrical isolation of the pulmonary veins is recommended during all AF ablation procedures. In addition, techniques to be used for ablation of persistent and long-standing persistent AF, adjunctive ablation strategies, nonablative strategies to improve outcomes of AF ablation, and endpoints for ablation of paroxysmal, persistent, and long-standing persistent AF will be reviewed. Currently many technologies and tools are employed for AF ablation procedures. Radiofrequency energy, cryoablation, and other energy sources and tools are in various stages of development and/or clinical investigation. Finally, anticoagulation strategies pre-, during, and postcatheter ablation of AF and technical aspects of ablation to maximize safety are discussed in this section.