• Title/Summary/Keyword: Radio Isotope

Search Result 53, Processing Time 0.018 seconds

Radon Removal Efficiency of Activated Carbon Filter from Coconut (코코넛 기반 활성탄 필터의 라돈 제거 효율)

  • Yun-Jin Ahn;Gi-Sub Kim;Tae-Hwan Kim;Sang-Rok Kim
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.141-149
    • /
    • 2023
  • The Korea Institute of Radiological and Medical Sciences plans to produce 225Ac, a therapeutic radio-pharmaceutical for precision oncology, such as prostate cancer. Radon, a radioactive gas, is generated by radium, the target material for producing 225Ac. The radon concentration is expected to be about 2000 Bq·m-3. High-concentration radon-generating facilities must meet radioactive isotope emission standards by lowering the radon concentration. However, most existing studies concerning radon removal using activated carbon filters measured radon levels at concentrations lower than 1000 Bq·m-3. This study measured 222Rn removal of coconut-based activated carbon filter under a high radon concentration of about 2000 Bq·m-3. The 222Rn removal efficiency of activated carbon impregnated with triethylenediamine was also measured. As a result, the 222Rn removal amount of the activated carbon filter showed sufficient removal efficiency in a 222Rn concentration environment of about 2000 Bq·m-3. In addition, despite an expectation of low radon reduction efficiency of Triethylenediamine-impregnated activated carbon, it was difficult to confirm a significant difference in the results. Therefore, it is considered that activated carbon can be used as a radioisotope exhaust filter regardless of whether or not Triethylenediamine is impregnated. The results of this study are expected to be used as primary data when building an air purification system for radiation safety management in facilities with radon concentrations of about 2000 Bq·m-3.

Finite Element Analysis of RF Coupler in Normal-Low Temperature (상온-저온 RF 커플러 유한요소해석)

  • Kim, Hansol;Lee, Hak Yong;Park, Chan;Lee, Jaeyeol;Lim, Dong Yeal;Yoo, Jeonghoon;Hyun, Myung Wook
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.10
    • /
    • pp.1101-1107
    • /
    • 2014
  • A heavy ion accelerator is a device that accelerates heavy ions in the radio frequency (RF) range. The electric field that flows into the RF cavity continuously accelerates heavy ions in accordance with the phase of the input electromagnetic wave. For the purpose, it is necessary to design a coupler shape that can stably transfer the RF wave into the cavity. The RF coupler in a heavy ion accelerator has a large temperature difference between the input port and output port, which radiates the RF waves. It is necessary to consider the heat deflection on the RF coupler that occurs as a result of the rapid temperature gradient from an ultra-low temperature about 0 K to a room temperature about 300 K. The purpose of this study was to improve the system performance through an analysis of the intensity of the output electric field and temperature distribution considering various shapes of the RF coupler, along with an analysis of the durability considering the heat deflection and heat loss.

Performance Enhancement Study of a Final Clarifier by the Optimum Design of Inlet and Baffle Condition (유입구 및 정류벽 최적설계에 의한 최종 침전지 성능 개선 연구)

  • Kim, Hey-Suk;Shin, Mi-Soo;Jang, Dong-Soon;Jung, Sung-Hee;Gang, Dong-Hyo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.2
    • /
    • pp.177-183
    • /
    • 2005
  • The effluent quality is directly affected by the separation of biological solids in a final clarifier because the majority of discharged $BOD_5$ and SS are virtually dependent on the results of biological solids in the sedimentation tank effluent. If a final clarifier is effectively designed and operated, the desired goal of clarification for wastewater can be achieved together with the cost reduction in the treatment of wastewater. To this end flow characteristics and the removal efficiency of SS are numerically investigated especially by the change of the inlet position and the installation of baffle to improve the performance of a rectangular final clarifier. The 2-D computer program developed in a rectangular coordinates has been successfully validated against experimental residence time distribution(RTD) curves obtained by tracing radio-isotope. The lowering of the inlet position weakens the density current and induces the settling of SS in the front zone of a clarifier. Thus the decreased traveling distance of the sludge increases the removal efficiency of SS in the effluent. The inlet baffle installed in the front region of clarifier prevents the short circuiting flow and induces to flow into the dense underflow, which eventually improves the effluent quality. In the case of lower inlet position, however, installation of baffle results in degradation of effluent quality. Consequently it is strongly recommended that in-depth numerical study be performed in advance for optimizing a clarifier design and retrofitting to improve effluent quality in a final clarifier.

A Study of Bone Uptake According to Renal Function in the Whole Body Bone Scan (전신 뼈 검사에서 신장 기능에 따른 뼈 섭취율에 대한 고찰)

  • Cho, Yong-In;Jang, Dong-Gun;Park, Cheol-Woo
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.299-304
    • /
    • 2013
  • Whole body bone scan has been used to confirm bone metastasis and follow-up study with radio isotope. However, if the factors related to $^{99m}Tc$ uptake and waiting time for study are inappropriate, it would be image of low quality. The purpose of present study was to investigate correlation between the evaluation index of renal function and uptake of radiopharmaceuticals. The population for this retrospective study consisted of 387 patients who underwent whole body bone scan between June 2012 and December 2012. As a result of quantitative and qualitative analysis, we were able to confirm that GFR of less than normal range and creatinine levels in blood of more than average are more likely to be under the mean uptake rate. As a result of analysis on the indicator affecting soft-tissue and bone uptake, the correlation of all elements was somewhat low. Also there are no statistically significances due to the other parameters we did not deal with. Therefore, further research on additional factors is needed for exact study and improvement of the image quality.

Treatment of Radioactive Liquid Waste Using Natural Evaporator and Resulted Exposure Dose Assessment (증발을 이용한 방사성 액체폐기물의 처리와 피폭선량평가)

  • Jeong, Gyeong-Hwan;Park, Seung-Kook;Kim, Eun-Han;Jung, Ki-Jung;Park, Hyun-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.2
    • /
    • pp.101-108
    • /
    • 1999
  • The influence of the relative humidity, the temperature and the velocity of supply air on evaporation rate has been studied with non-boiling forced evaporation system in order to treat very low level radioactive liquid wastes produced from the decontamination and decommissioning activities. Experimental data on the evaporation rate have been obtained with the divers variables and experimental equation of air velocity was also obtained by the correlation of those data. The decontamination factor of this system was also obtained by the experimental data from a simulated liquid waste containing Cs-137 radio isotope ; $DF=10^4$. Since the commercial system will be operated for the treatment of the very low level radioactive liquid waste produced from decontamination & decommissioning of TRIGA Mark-II&III research reactor, the environmental assessment has been conducted to improve the operational safety. Exposure dose rate for an individual member of general public was assessed, and it showed that it was very lower than individual dose limits. The release of radioactivity of radioisotope material (Cs-137) to the environment was assessed, and result showed that it was $4.637{\times}10^{-14}\;{\mu}Ci/cc$.

  • PDF

Receptor Binding Affinities of Synthetic Cannabinoids Determined by Non-Isotopic Receptor Binding Assay

  • Cha, Hye Jin;Song, Yun Jeong;Lee, Da Eun;Kim, Young-Hoon;Shin, Jisoon;Jang, Choon-Gon;Suh, Soo Kyung;Kim, Sung Jin;Yun, Jaesuk
    • Toxicological Research
    • /
    • v.35 no.1
    • /
    • pp.37-44
    • /
    • 2019
  • A major predictor of the efficacy of natural or synthetic cannabinoids is their binding affinity to the cannabinoid type I receptor ($CB_1$) in the central nervous system, as the main psychological effects of cannabinoids are achieved via binding to this receptor. Conventionally, receptor binding assays have been performed using isotopes, which are inconvenient owing to the effects of radioactivity. In the present study, the binding affinities of five cannabinoids for purified $CB_1$ were measured using a surface plasmon resonance (SPR) technique as a putative non-isotopic receptor binding assay. Results were compared with those of a radio-isotope-labeled receptor binding assay. The representative natural cannabinoid ${\Delta}^9$-tetrahydrocannabinol and four synthetic cannabinoids, JWH-015, JWH-210, RCS-4, and JWH-250, were assessed using both the SPR biosensor assay and the conventional isotopic receptor binding assay. The binding affinities of the test substances to $CB_1$ were determined to be (from highest to lowest) $9.52{\times}10^{-3}M$ (JWH-210), $6.54{\times}10^{-12}M$ (JWH-250), $1.56{\times}10^{-11}M$ (${\Delta}^9$-tetrahydrocannabinol), $2.75{\times}10^{-11}M$ (RCS-4), and $6.80{\times}10^{-11}M$ (JWH-015) using the non-isotopic method. Using the conventional isotopic receptor binding assay, the same order of affinities was observed. In conclusion, our results support the use of kinetic analysis via SPR in place of the isotopic receptor binding assay. To replace the receptor binding affinity assay with SPR techniques in routine assays, further studies for method validation will be needed in the future.

The Study of Radiation Reducing Method during Injection Radiopharmaceuticals (방사성의약품 투여 시 피폭선량 저감에 대한 연구)

  • Cho, Seok-Won;Jung, Seok;Park, June-Young;Oh, Shin-Hyun;NamKoong, Hyuk;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.80-85
    • /
    • 2012
  • Purpose: The whole body bone scan is an examination that visualizing physiological change of bones and using bone-congenial radiopharmaceutical. The patients are intravenous injected radiopharmaceutical which labeled with radioactive isotope ($^{99m}Tc$) emitting 140 keV gammarays and scanned after injection. The 3 principles of radiation protection from external exposureare time, distance and shielding. On the 3 principles of radiation protection basis, radiopharmaceutical might just as well be injected rapidly for reducing radiation because it might be the unopened radiation source. However the radiopharmaceuticals are injected into patient directly and there is a limitation of distance control. This study confirmed the change of radiation exposure as change of distance from radiopharmaceutical and observed the change of radiation exposure afte rsetting a shelter for help to control radio-technician's exposure. Materials & methods: For calculate the average of injection time, the trained injector measured the injection time for 50 times and calculated the average (2 minutes). We made a source as filled the 99mTc-HDP 925 MBq 0.2 mL in a 1 mL syringe and measured the radiation exposure from 50 cm,100 cm,150 cm and 200 cm by using Geiger-Mueller counter (FH-40, Thermo Scientific, USA). Then we settled a lead shielding (lead equivalent 6 mm) from the source 25 cm distance and measured the radiation exposure from 50 cm distance. For verify the reproducibility, the measurement was done among 20 times. The correlation between before and after shielding was verified by using SPSS (ver. 18) as paired t-test. Results: The radiation doses according to distance during 2 minutes from the source without shielding were $1.986{\pm}0.052{\mu}$ Sv in 50 cm, $0.515{\pm}0.022{\mu}$ Sv in 100 cm, $0.251{\pm}0.012{\mu}$ Sv in 150 cm, $0.148{\pm}0.006{\mu}$ Sv in 200 cm. After setting the shielding, the radiation dose was $0.035{\pm}0.003{\mu}$ Sv. Therefore, there was a statistical significant difference between the radiation doses with shielding and without shielding ($p$<0.001). Conclusion: Because the great importance of whole body bone scan in the nuclear medicine, we should make an effort to reduce radiation exposure during radiopharmaceutical injections by referring the principles of radiation protection from external exposure. However there is a limitation of distance for direct injection and time for patients having attenuated tubules. We confirmed the reduction of radiation exposure by increasing distance. In case of setting shield from source 25 cm away, we confirmed reducing of radiation exposure. Therefore it would be better for reducing of radiation exposure to using shield during radiopharmaceutical injection.

  • PDF

Radio-isotope Red Cell Survival Studies Recommended by ICSH (방사성동위원소(放射性同位元素)를 이용(利用)한 적혈구수명측정법(赤血球壽命測定法)(ICSH추천(推薦)))

  • The Korea Society of Nuclear Medicine The Korea Society of Nuclear Medicine
    • The Korean Journal of Nuclear Medicine
    • /
    • v.5 no.1
    • /
    • pp.1-10
    • /
    • 1971
  • 혈액질환(血液疾患), 특히 용혈성빈혈(溶血性貧血)을 수반(隨伴)한 경우(境遇)에 적혈구(赤血球)의 생성(生成) 및 파괴과정(破壞過程)을 정확(正確)히 파악(把握)하는 것은 중요(重要)하여 특히 적혈구수명측정(赤血球壽命測定)은 빈혈(貧血)의 본능(本能) 및 발생기전(發生機轉)을 이해(理解)하는데는 물론 병인적(病因的) 치료(治療) 및 예후(豫後)를 결정(決定)하는데 대단(犬端)히 유용(有用)하다. 적혈구수명측정(赤血球壽命測定)에는 1919년(年) Ashby가 개발(開發)한 differential agglutination법(法)이 이용(利用)되어 왔으나 수혈(輸血)에 따른 위험(危險)이 있고 방법(方法)이 복잡(複雜)하다는 단점(短點)을 가져 새로운 적혈구수명측정법(赤血球壽命測定法)이 연구(硏究)되어 왔다. 최근(最近)에 $^{51}Cr$이나, $^{32}DFP$같은 방사성동위원소(放射性同位元素)를 이용(利用)한 방법(方法)이 도입(導入)된 이래(以來) 임상적(臨床的)으로 적혈구수명측정(赤血球壽命測定)이 많이 시행(施行)되고 있지만 아직까지도 그 방법(方法)이나 결과(結果)의 해석(解釋)에 표준화(標準化)가 안되어 있다. 현재(現在) 임상영역(臨床領域)에서 가장 널리 이용(利用)되고 있는 적혈구수명측정법(赤血球壽命測定法)은 방사성(放射性) chromium($^{51}Cr$)법(法)으로 1950년(年) Gray와 Sterling에 의(依)해 창안(創案)된 이래(以來) 많은 학자(學者)들에 의(依)해 여러 가지 변법(變法)이 고안(考案)되어 왔는데, 이의 가장 큰 이유(理由)는 $^{51}Cr$이 적혈구표지(赤血球標識)에 가장 이상적(理想的)인 것만은 아니고 그 결과(結果)에 많은 요인(要因)들이 영향(影響)을 미치기 때문이다. 또 이런 변법(變法)의 사용(使用)은 각(各) 검사(檢査)에서 계산(計算)된 측정치(測定値)에 차이(差異)가 있어 그 결과(結果)의 해석(解釋) 및 비교(比較) 검토(檢討)에 적지않은 난점(難點)이 생겨 표준화(標準化)된 공통적(共通的)인 방법(方法)의 사용(使用)이 중요(重要)하다는 사실(事實)이 인식(認識)되게 되었다. 1966년(年) 호주(濠洲)의 Sydney에서 개최(開催)되었든 제11차(第11次) 국제혈액학회(國際血學會)때 열린 제4차(第4次) International Committee for Standardization in Haematology(ICSH)에서 Diagnostic Applications of Radioisotopes in Haematology에 관(關)한 expert panel을 갖을것을 의결(議決)하여 다음과 같은 12명(名)의 위원(委員)이 결정(決定)되었으며 위원회(委員會)의 의장(議長)에 Dr. Szur, 총무(總務)에 Dr. Glass가 각각(各各) 선임(選任)되었다. 그간(間) 1967년(年) 영경(英京) London에서 첫 회합(會合)이 있은후(後) New York, Vienna(IAEA후원(後援)) Brthesda(NIH후원(後援))에서 전문위원회(專門委員會)를 갖고 적혈구수명측정법(赤血球壽命測定法)에 관(關)한 의견(意見)의 일치(一致)를 보았다. ICSH와 국제혈액학회(國際血學會)에서는 이번에 결정(決定)된 적혈구수명측정법(赤血球壽命測定法)을 널리 소개(紹介)하며, 측정법(測定法)과 얻어진 결과(結果)의 해석(解釋)에 표준화(標準化)를 기(期)할 목적(目的)으로 이에 연관성(聯關性)있는 전문지(專門誌)에 게재(揭載)할 것을 요청(要請) 받었기에 이에 전문(全文)을 소개(紹介)하는 바이다. 이들은 방사성(放射性) chromium 법(法)의 모든 세부적(細部的)인 면(面)을 표준화(標準化)하고 있으며 그간(間) 가장 논란(論難)의 대상(對象)이 되었던, $^{51}Cr$-표지방법(標識方法)에 있어서의 세가지 변법(變法), 즉 ACD법(法), Citrate-wash법(法), ACD/ascorbic acid법(法)을 모두 인정(認定)하고 있다. 또한, DFP($DF^{32}P$ 또는 $^3H-DFP$) 표지법(標識法)의 표준방법(標準方法)도 기술(記述)하고 있으며, 더욱 중요(重要)한 것은 적혈구수명측정법(赤血球壽命測定法)으로서 현재(現在)까지 대부분(大部分)의 학자(學者)가 사용(使用)하여 왔던 지표(指標)인 $T_{50}Cr$ 대신(代身)에 mean red cell life span을 사용(使用)할 것을 권(勸)하고 있다.

  • PDF

Validation Study for Image Performance of I-131 Using GATE Simulation Program (GATE 시뮬레이션 프로그램을 이용한 I-131의 영상 특성의 타당성에 관한 연구)

  • Baek, Cheol-Ha;Kim, Dae Ho;Lee, Yong-Gu;Lee, Youngjin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.5
    • /
    • pp.133-137
    • /
    • 2017
  • The purpose of this study was to validate for GATE (Geant4 Application for Tomographic Emission) simulation by comparing the results of GATE simulation and experiment in real SPECT system. Futhermore, we want to prove that it is possible that the quantitative research of gamma camera/SPECT imaging for therapeutic radio isotope by using GATE simulation. In this study, the SPECT system on simulation referred to the parameters of Stream-R Forte version 1.2 (Philips Medical System, Best and Heerlen, Netherlands). To understand the I-131 image of gamma camera/SPECT system, we acquired the energy spectrum and measured the full width at half maximum (FWHM) which comes from line spread function (LSF) with and without scatter material in real SPECT system. And to compare with experiment, we also measured the FWHM and acquired the energy spectrum without scatter material in GATE simulation. As a result, without scatter material, the energy peak was almost same location, which are located nearby 364 keV, and other spectrum factors are same tendency in both cases. The FWHM was increased by increasing the distance of source to detector, and the error rate was approximately 3.8%. When we used the line source with scatter material, energy spectrum also indicated similar tendency in both cases. As you confirmed earlier, GATE simulation included real instrument and radioisotope characters for therapeutic radioisotope. Therefore this result that it was possible that various quantitative study for therapeutic radioisotope imaging in gamma camera/SPECT using GATE simulation.

Genes of Wild Rice (Oryza grandiglumis) Induced by Wounding and Yeast Extract (상처와 효모추출물 처리조건에서 유발되는 야생벼 유전자 스크린)

  • Shin, Sang-Hyun;Im, Hyun-Hee;Lee, Jai-Heon;Kim, Doh-Hoon;Chung, Won-Bok;Kang, Kyung-Ho;Cho, Sung-Ki;Shin, Jeong-Sheop;Chung, Young-Soo
    • Journal of Life Science
    • /
    • v.14 no.4
    • /
    • pp.650-656
    • /
    • 2004
  • Oryza grandiglumis (CCDD, 2n=48), one of the wild rice species, has been known to possess fungal-,bacterial-, and insect-resistance against sheath blight, rice blast, bacterial leaf blight and brown plant hopper (Nilaparvata lugens). To rapidly isolate differentially expressed genes responding to fungal and wounding stress, wounding and yeast extract were treated to O. grandiglumis for 24 hrs. Suppression subtractive hybridization (SSH) method was used to obtain differentially expressed genes from yeast extract and wounding treated plants. Seven hundreds and seventy six clones were obtained by subcloning PCR product, and colony array and screening were carried out using radio-isotope labeled cDNA probes prepared from the wounding and yeast extract treated plants. One hundred and fifteen colonies were confirmed as true positive ones. Average insert size of the clones were ranged from 400 bp to 700 bp and all the inserts were sequenced. To decide the identity of those clones, sequences were analyzed by sequence homology via GenBank database. The homology search result showed that 68 clones were matched to the genes with known function; 16 were related to primary metabolism, 5 to plant retrotransposons, 5 to defense related metallothionein-like genes. In addition to that, others were matched to various genes with known function in amino acid synthesis and processing, membrane transport, and signal transduction, so on. In northern blot analysis, induced expressions of ogwfi-161, ogwfi-646, ogwfi-663, and ogwfi-695 by wounding and yeast extract treatments were confirmed. The result indicates that SSH method is very efficient for rapid screening of differentially expressed genes.