• 제목/요약/키워드: Radiation spectrum

검색결과 504건 처리시간 0.021초

Investigation of the Dynamic Properties of Railway Tracks using a Model for Calculation of Generation of Wheel/Rail Noise

  • Koh, Hyo-In;Nordborg, Anders
    • International Journal of Railway
    • /
    • 제7권4호
    • /
    • pp.109-116
    • /
    • 2014
  • For optimization of a low-noise track system, rail vibration and noise radiation needs to be investigated. The main influencing parameters for the noise radiation and the quantitative results of every track system can be obtained using a calculation model of generation and radiation of railway noise. This kind of model includes contact modeling and the calculation model of the dynamic properties of the wheel and the rail. This study used a nonlinear wheel/rail interaction model in the time domain to investigate the excitation of the rolling noise. Wheel/rail response is determined by time integrating Green's function of the rail together with force impulses from the wheel/rail contact. This model and the results of the study can be used for supporting calculation with the conventional model by an addition of the contributions due to nonlinearities to the roughness spectrum.

Development of Spectroscopy Toolkit for Spectrum Measurement Experiments Using a CsI(Tl)/PIN Diode Detector

  • Nam, Young-Mi;Kim, Han-Soo;Ha, Jang-Ho;Lee, Jae-Hyung
    • Journal of Radiation Protection and Research
    • /
    • 제35권2호
    • /
    • pp.77-80
    • /
    • 2010
  • The spectroscopy toolkit has been developed and tested. The toolkit consists of a CsI(Tl)/PIN diode detector, integrated electronics, and a multi.channel.analyzer and its size was 40 cm(width) by 20 cm(length) by 6 cm(high). It is compact, very portable and simpler and cheaper compared to the conventional spectroscopy system. The gamma energy resolutions of the toolkit were 7.9% for the 660 keV of $^{137}Cs$ and 4.9% for 1,332 keV of $^{60}Co$ respectively. The linearity for gamma energies was good. When the energy spectrum of a ceramic sample containing $^{232}Th$ was measured with the spectroscopy toolkit for 20 minutes, there were significant peaks of the heavy metal. These results show that the resolution of the spectroscopy toolkit is sufficient to accumulate a quality spectrum in a few minutes by using weak, encapsulated commercial sources. Furthermore a toolkit experiment that how to measure energy spectra using the toolkit, and how to identify specific isotopes in a pottery piece, could be widely adopted for education and even for more sophisticated and higher level experiments.

Energy Spectrum Measurement of High Power and High Energy (6 and 9 MeV) Pulsed X-ray Source for Industrial Use

  • Takagi, Hiroyuki;Murata, Isao
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.93-99
    • /
    • 2016
  • Background: Industrial X-ray CT system is normally applied to non-destructive testing (NDT) for industrial product made from metal. Furthermore there are some special CT systems, which have an ability to inspect nuclear fuel assemblies or rocket motors, using high power and high energy (more than 6 MeV) pulsed X-ray source. In these case, pulsed X-ray are produced by the electron linear accelerator, and a huge number of photons with a wide energy spectrum are produced within a very short period. Consequently, it is difficult to measure the X-ray energy spectrum for such accelerator-based X-ray sources using simple spectrometry. Due to this difficulty, unexpected images and artifacts which lead to incorrect density information and dimensions of specimens cannot be avoided in CT images. For getting highly precise CT images, it is important to know the precise energy spectrum of emitted X-rays. Materials and Methods: In order to realize it we investigated a new approach utilizing the Bayesian estimation method combined with an attenuation curve measurement using step shaped attenuation material. This method was validated by precise measurement of energy spectrum from a 1 MeV electron accelerator. In this study, to extend the applicable X-ray energy range we tried to measure energy spectra of X-ray sources from 6 and 9 MeV linear accelerators by using the recently developed method. Results and Discussion: In this study, an attenuation curves are measured by using a step-shaped attenuation materials of aluminum and steel individually, and the each X-ray spectrum is reconstructed from the measured attenuation curve by the spectrum type Bayesian estimation method. Conclusion: The obtained result shows good agreement with simulated spectra, and the presently developed technique is adaptable for high energy X-ray source more than 6 MeV.

몬테카를로 시뮬레이션을 통한 연속 엑스선 에너지에서 납(Pb)과 텅스텐(W)의 흡수 스펙트럼 비교 연구 (Absorbed Spectrum Comparison of Lead and Tungsten in Continuous X-ray Energy using Monte Carlo Simulation)

  • 김교태;강상식;노시철;정봉재;조창훈;허예지;박지군
    • 한국방사선학회논문지
    • /
    • 제6권6호
    • /
    • pp.483-487
    • /
    • 2012
  • 1895년에 발견된 X-ray는 현재 의료 분야 뿐 아니라 광범위한 분야에 이용되고 있다. 방사선의 발견 이 후 사람들은 방사선피폭의 위험성을 인식하게 되었고 방사선 피폭을 낮추기 위한 노력의 일환으로 방사선 방어에 관한 원칙을 권고하였다. 이 권고안에서는 모든 불필요한 피폭은 방지되어야 하고, 모든 선량은 적용 가능한 한 낮게 유지해야 한다는 두 가지의 방사선 방어 기본 개념을 포함하고 있다. 현재 임상의 일반검사실에서는 차폐를 위하여 납(Pb)을 사용하고 있지만 인체에 치명적인 납 중독의 문제점을 가지고 있어 대체 물질이 제시되었고 그 중에 텅스텐이란 물질이 제시되었다. 이에 본 연구에서는 인체에 유해하지 않는 텅스텐의 연속 X선 에너지 영역에서 두께에 따른 흡수 스펙트럼을 몬테카를로 시뮬레이션을 통하여 모의 추정하였고, 납의 흡수 스펙트럼과 비교하고자 하였다. 모의 추정을 한 결과 납 보다 텅스텐이 전체적인 영역에서 흡수 확률이 더 높은 것으로 확인하였으며, 특히 70 keV ~ 90 keV에서는 텅스텐이 납보다 탁월하게 높은 흡수효율을 보여 텅스텐이 고에너지 진단 영역의 X-ray 에너지 차폐에 더 유용할 것으로 사료된다.

유방촬영장치의 타깃에 따른 에너지스펙트럼 및 팬텀영상화질 (The energy spectrum and phantom image quality according to mammography target-filter combinations)

  • 장세영;오왕균;박종배;진계환
    • 한국방사선학회논문지
    • /
    • 제7권1호
    • /
    • pp.51-55
    • /
    • 2013
  • 엑스선의 에너지가 높으면 엑스선이 피사체(object)를 통과하여 영상의 대조도를 떨어뜨리고 엑스선의 에너지가 낮으면 영상의 대조도는 증가시키지만 엑스선이 피사체에 흡수되어 환자의 피폭선량을 증가시킨다. 그러므로 적정한 엑스선 에너지는 영상의 질과 피폭선량에 영향을 미치는 매우 중요한 요소이다. 본 논문에서는 새로운 양극물질을 사용하는 유방촬영 장치의 도입에 따라 방사선 선질이 다양해진 유방촬영장치의 영상품질관리와 환자선량관리을 위하여 유방촬영장치의 타겟 물질에 따른 에너지스펙트럼을 시뮬레이션하고 팬텀 영상의 화질을 비교하였다.

A Review of Organ Dose Calculation Methods and Tools for Patients Undergoing Diagnostic Nuclear Medicine Procedures

  • Choonsik Lee
    • Journal of Radiation Protection and Research
    • /
    • 제49권1호
    • /
    • pp.1-18
    • /
    • 2024
  • Exponential growth has been observed in nuclear medicine procedures worldwide in the past decades. The considerable increase is attributed to the advance of positron emission tomography and single photon emission computed tomography, as well as the introduction of new radiopharmaceuticals. Although nuclear medicine procedures provide undisputable diagnostic and therapeutic benefits to patients, the substantial increase in radiation exposure to nuclear medicine patients raises concerns about potential adverse health effects and calls for the urgent need to monitor exposure levels. In the current article, model-based internal dosimetry methods were reviewed, focusing on Medical Internal Radiation Dose (MIRD) formalism, biokinetic data, human anatomy models (stylized, voxel, and hybrid computational human phantoms), and energy spectrum data of radionuclides. Key results from many articles on nuclear medicine dosimetry and comparisons of dosimetry quantities based on different types of human anatomy models were summarized. Key characteristics of seven model-based dose calculation tools were tabulated and discussed, including dose quantities, computational human phantoms used for dose calculations, decay data for radionuclides, biokinetic data, and user interface. Lastly, future research needs in nuclear medicine dosimetry were discussed. Model-based internal dosimetry methods were reviewed focusing on MIRD formalism, biokinetic data, human anatomy models, and energy spectrum data of radionuclides. Future research should focus on updating biokinetic data, revising energy transfer quantities for alimentary and gastrointestinal tracts, accounting for body size in nuclear medicine dosimetry, and recalculating dose coefficients based on the latest biokinetic and energy transfer data.

마늘중 Alliin의 분리 및 그 특성규명에 관한 연구 (Isolation and Characterization of Alliin From Garlic Bulbs)

  • 한인자;이미순;정기용
    • Applied Biological Chemistry
    • /
    • 제16권1호
    • /
    • pp.12-17
    • /
    • 1973
  • 냉동시킨 마늘로부터 Alliin을 분리(分離)해서 순수한 상태(相態)로 결정화(結晶化) 시켰다. 분리(分離)된 Alliin의 순도(純度)는 융점측정과 thin-layer chromatography에 의하여 확증되었다. Sulfoxide bond 및 아미노산의 기능기는 IR spectrum에 의하여, vinyl 결합은 NMR spectrum에 의하여 확인되었다. 분자량, allyl 및 기타의 결합은 MS spectrum에 의하여 확인(確認)되었다.

  • PDF

비상시 환경방사능 모니터링을 위한 공기부유진 시료의 감마선에너지 스펙트럼에 대한 핵종판별 (Nuclide Identification of Gamma Ray Energy Peaks from an Air Sample for the Emergency Radiation Monitoring)

  • 변종인;윤석원;최희열;임성아;이동명;윤주용
    • Journal of Radiation Protection and Research
    • /
    • 제34권4호
    • /
    • pp.170-175
    • /
    • 2009
  • 감마선분광분석법을 이용하여 비상시 환경방사능 모니터링을 수행할 경우 스펙트럼 측정시 해당 시료의 종류에 따른 백그라운드 자료 확보와 이를 활용한 체계적인 핵종확인 과정이 선행되어야 한다. 비상시 환경방사능 모니터링을 고려하여 24시간 동안 포집 후 회화시킨 공기부유진 시료를 HPGe 감마선분광분석 시스템으로 계측하여 감마선에너지 스펙트럼을 얻었으며, 그 스펙트럼에서 보이는 피이크들의 핵종을 판별하기 위해 두 가지 방법 - 1) 반감기 추정 2) 핵자료를 이용한 축차우연동시합성피이크 확인 - 으로 접근하였다. 그 결과로서 공기부유진의 감마선에너지스펙트럼에 대한 핵종판별결과 자료를 산출하였다.

Development of a neural network method for measuring the energy spectrum of a pulsed electron beam, based on Bremsstrahlung X-Ray

  • Sohrabi, Mohsen;Ayoobian, Navid;Shirani, Babak
    • Nuclear Engineering and Technology
    • /
    • 제53권1호
    • /
    • pp.266-272
    • /
    • 2021
  • In the pulsed electron beam generators, such as plasma focus devices and linear induction accelerators whose electron pulse width is in the range of nanosecond and less, as well as in cases where there is no direct access to electron beam, like runaway electrons in Tokamaks, measurement of the electron energy spectrum is a technical challenge. In such cases, the indirect measurement of the electron spectrum by using the bremsstrahlung radiation spectrum associated with it, is an appropriate solution. The problem with this method is that the matrix equation between the two spectrums is an ill-conditioned equation, which results in errors of the measured X-ray spectrum to be propagated with a large coefficient in the estimated electron spectrum. In this study, a method based on the neural network and the MCNP code is presented and evaluated to recover the electron spectrum from the X-ray generated by collision of the electron beam with a target. Multilayer perceptron network showed good accuracy in electron spectrum recovery, so that for the X-ray spectrum with errors of 3% and 10%, the network estimated the electron spectrum with an average standard error of 8% and 11%, on all of the energy intervals.

Gamma-ray Exposure Rate Monitoring by Energy Spectra of NaI(Tl) Scintillation detectors

  • Lee, Mo Sung
    • Journal of Radiation Protection and Research
    • /
    • 제42권3호
    • /
    • pp.158-165
    • /
    • 2017
  • Background: Nuclear facilities in South Korea have generally adopted pressurized ion chambers to measure ambient gamma ray exposure rates for monitoring the impact of radiation on the surrounding environment. The rates assessed with pressurized ion chambers do not distinguish between natural and man-made radiation, so a further step is needed to identify the cause of abnormal variation. In contrast, using NaI(Tl) scintillation detectors to detect gamma energy rates can allow an immediate assessment of the cause of variation through an analysis of the energy spectra. Against this backdrop, this study was conducted to propose a more effective way to monitor ambient gamma exposure rates. Materials and Methods: The following methods were used to analyze gamma energy spectra measured from January to November 2016 with NaI detectors installed at the Korea Atomic Energy Research Institute (KAERI) dormitory and Hanbat University. 1) Correlations of the variation of rates measured at the two locations were determined. 2) The dates, intervals, duration, and weather conditions were identified when rates increased by $5nSv{\cdot}h^{-1}$ or more. 3) Differences in the NaI spectra on normal days and days where rates spiked by $5nSv{\cdot}h^{-1}$ or more were studied. 4) An algorithm was derived for automatically calculating the net variation of the rates. Results and Discussion: The rates measured at KAERI and Hanbat University, located 12 kilometers apart, did not show a strong correlation (coefficient of determination = 0.577). Time gaps between spikes in the rates and rainfall were factors that affected the correlation. The weather conditions on days where rates went up by $5nSv{\cdot}h^{-1}$ or more featured rainfall, snowfall, or overcast, as well as an increase in peaks of the gamma rays emitted from the radon decay products of $^{214}Pb$ and $^{214}Bi$ in the spectrum. This study assumed that $^{214}Pb$ and $^{214}Bi$ exist at a radioactive equilibrium, since both have relatively short half-lives of under 30 minutes. Provided that this assumption is true and that the gamma peaks of the 352 keV and 1,764 keV gamma rays emitted from the radionuclides have proportional count rates, no man-made radiation should be present between the two energy levels. This study proved that this assumption was true by demonstrating a linear correlation between the count rates of these two gamma peaks. In conclusion, if the count rates of these two peaks detected in the gamma energy spectrum at a certain time maintain the ratio measured at a normal time, such variation can be confirmed to be caused by natural radiation. Conclusion: This study confirmed that both $^{214}Pb$ and $^{214}Bi$ have relatively short half-lives of under 30 minutes, thereby existing in a radioactive equilibrium in the atmosphere. If the gamma peaks of the 352 keV and 1,764 keV gamma rays emitted from these radionuclides have proportional count rates, no man-made radiation should exist between the two energy levels.