• 제목/요약/키워드: Radiation spectrum

검색결과 504건 처리시간 0.023초

NONTHERMAL RADIATION FROM RELATIVISTIC ELECTRONS ACCELERATED AT SPHERICALLY EXPANDING SHOCKS

  • Kang, Hyesung
    • 천문학회지
    • /
    • 제48권1호
    • /
    • pp.9-20
    • /
    • 2015
  • We study the evolution of the energy spectrum of cosmic-ray electrons accelerated at spherically expanding shocks with low Mach numbers and the ensuing spectral signatures imprinted in radio synchrotron emission. Time-dependent simulations of diffusive shock acceleration (DSA) of electrons in the test-particle limit have been performed for spherical shocks with parameters relevant for typical shocks in the intracluster medium. The electron and radiation spectra at the shock location can be described properly by the test-particle DSA predictions with instantaneous shock parameters. However, the volume integrated spectra of both electrons and radiation deviate significantly from the test-particle power-laws, because the shock compression ratio and the flux of injected electrons at the shock gradually decrease as the shock slows down in time. So one needs to be cautious about interpreting observed radio spectra of evolving shocks based on simple DSA models in the test-particle regime.

몬테칼로법을 위한 선량당량 산정법의 도출 (Derivation of a Monte Carlo Estimator for Dose Equivalent)

  • 이재기
    • Journal of Radiation Protection and Research
    • /
    • 제10권2호
    • /
    • pp.89-95
    • /
    • 1985
  • 연속감속근사법(CSDA)과 감속평균선질계수를 이용하여 선량당량 정의에서의 본래의 LET분포 개념을 하전입자속 스펙트럼의 개념으로 변환함으로써 새로운 선량당량 산정법을 도출하였다. 이 산정법을 몬테칼로법에 적용함으로써 주어진 방사선장에 위치한 피사체 내에서의 선량당량을 직접적으로 간편하게 산출할 수 있다. 산정에 필요한 감속평균 선질계수는 중성자와 연조직과의 상호작용으로부터 발생될 수 있는 모든 하전입자에 대하여 10 MeV 이하의 에너지 범위에서 산출하여 제시하였다.

  • PDF

99mTc의 에너지 스펙트럼 변화에 따른 납 앞치마의 차폐 효과 평가 (Evaluation of the Shielding Effect of Lead Apron according to the Energy Spectrum Change of 99mTc)

  • 윤창용;지영식
    • 한국방사선학회논문지
    • /
    • 제17권6호
    • /
    • pp.889-896
    • /
    • 2023
  • 핵의학과에서 가장 많이 사용되는 99mTc를 점선원과 산란팬텀을 이용하여 에너지스펙트럼 변화를 분석하고 변화된 감마선 에너지에 따른 납 앞치마의 차폐효과를 평가하였다. 산란팬텀의 감마선 에너지 스펙트럼은 점선원보다 광전피크 영역은 감소하고 컴프턴 산란영역은 증가하였다. 감마선원 형태 변화에 따른 에너지 영역별 계수치는 점선원의 계수치보다 20 cm 거리에서 최대 66.1 %의 감소율을 보였으며 컴프턴 산란 영역에서는 산란팬텀의의 계수치가 점선원의 계수치보다 최대 40 cm 거리에서 122.2 % 증가하는 결과를 보였다. 감마카메라를 이용한 선원과 산란팬텀의 거리에 따른 차폐율 차이에서 광전피크 영역은 유사한 결과를 보였으나 컴프턴 산란영역에서는 20 cm거리에서 산란팬텀의 차폐율이 점선원의 차폐율보다 29.2% 증가하였으며 거리가 증가함에 따라 차폐율 차이는 감소하였다. 방사선 선량계를 이용한 납 앞치마 차폐율 측정에서 산란팬텀의 차폐율은 최대 15.3 %의 차이를 보였으며 거리가 증가할수록 두 선원의 차폐율 차이는 감소하였다. 산란팬텀의 납 앞치마 차폐율이 점선원보다 높고 선원과 가까운 거리일수록 납 앞치마의 효과는 증가하는 결과로 방사성의약품을 주입한 환자를 직접 대면할 때 납 앞치마의 착용은 방사선피폭 저감화에 도움이 될 것으로 판단된다.

Response Matrix에 의한 감마선(線) Spectrum 및 그 조사선량(照射線量) 해석(解析) (Analysis of Gamma-ray Spectrum and Assessment of Corresponding Exposure Rate by Means of Response Matrix Method)

  • 김성관;전재식
    • Journal of Radiation Protection and Research
    • /
    • 제11권1호
    • /
    • pp.3-14
    • /
    • 1986
  • $3'{\times}3'$ 원통형 NaI(T1) 검출기와 다중파고분석기(多重波高分析器)를 사용하여 측정한 $0.05{\sim}2.0MeV$ 구간의 ${\gamma}$선 spectrum에서 실(實)spctrum을 구하기 위하여 조사선량율(照射線量率)산출에 편리한 response matrix 방법을 사용하였다. Response mateix 구성에는, 위의 에네지 구간을 0.1 MeV의 등간격으로 나눈 $20{\times}20$ matrix로 한것과 검출기의 분해능이 입사 ${\gamma}$선 에너지의 평방근(平方根)에 의존한다는 가정하에 $0.1(MeV)^{1/2}$구간으로 나누어 $14{\times}14$ matrix로 구성한, 두가지 방법을 사용하였으며 그 역(逆)matrix들은 P-E 82/32 콤퓨터로 계산하였다. 이 방법으로 얻은 조사선량율은 에너지와 flux가 알려진 ${\gamma}$선량(陽)에 대하여 흔히 사용되는 계산방법으로 구한값과 10% 이내에서 일치하고 있으며, 선량측정학적(線量測定學的) 견지에서는 $E^{1/2}$ 구간으로 형성된 matrix가 등에너지간격으로 구성된 것보다 현실적인 것으로 판단되었다.

  • PDF

A GRADIENT-T SZE

  • HATTORI MAKOTO;OKABE NOBUHIRO
    • 천문학회지
    • /
    • 제37권5호
    • /
    • pp.543-546
    • /
    • 2004
  • The inverse Compton scattering of the cosmic microwave background (CMB) radiation with electrons in the intracluster medium which has a temperature gradient, was examined by the third-order perturbation theory of the Compton scattering. A new type of the spectrum distortion of the CMB was found and named as gradient T Sunyaev-Zel'dovich effect (gradT SZE). The spectrum has an universal shape. There is a zero distortion point, the cross over frequency, at 326GHz. When the hotter region locates closer to an observer, the intensity becomes brighter than the CMB in the frequency region lower than the cross over frequency and fainter than the CMB in the frequency region higher than the cross over frequency. When the cooler region locates closer to an observer, the distorted part of the spectrum has an opposite sign to the above case. The amplitude of the spectrum distortion does not de-pend on the electron density and depends on the heat conductivity and the total temperature variation along a line of sight. Therefore, the gradT SZE provides an unique opportunity to measure thermally nonequilibrium electron momentum distribution function in the ICM and combined with the X-ray measurements of the electron temperature distribution provides an opportunity of direct measurement of the heat conductivity in the ICM.

중성자 에너지 측정을 위한 NE213-PSD 장치의 감응 분석 (Response Analysis of the NE213-PSD System for Neutron Energy Spectreum Measurement)

  • 이경주
    • 분석과학
    • /
    • 제5권4호
    • /
    • pp.367-372
    • /
    • 1992
  • 방사선 중성자 선원의 에너지 스펙트럼을 측정하기 위하여 액체 섬광 검출기(NE213)와 펄스모형 분리장치를 감마선 선원과 중성자 선원을 이용하여 그 감응 특성을 분석하였다. Am-Be 선원을 이용하여 이 장치에 대한 "Figure of Merit"을 측정한 결과 1.13 이었다. 이 값은 단색 에너지 중성자 선원인 $^{12}C(d,\;n)^{13}N$에서의 1.3 과 상당히 유사한 값을 보여 준다. NE213-PSD 장치의 성능 시험을 위한 이 실험결과는 중성자-감마 혼합 방사선장에서 스펙트럼의 측정과 중성자 에너지 스펙트럼과 속밀도 측정표준을 확립하는 데 기술적으로 유용하게 쓰일 것이다.

  • PDF

High Resolution Near Infrared Spectrum of NGC 7023

  • Le, Huynh Anh N.;Pak, Soojong;Lee, Hye-In;Lee, Jae-Joon;Nguyen-Luong, Quang;Kaplan, Kyle;Jaffe, Daniel T.
    • 천문학회보
    • /
    • 제39권2호
    • /
    • pp.93.1-93.1
    • /
    • 2014
  • The reflection nebula NGC 7023 is a typical example of a photodissociation region (PDR), which consists of high density molecular gas that is exposed to an intense UV radiation field. The source of the UV photons in NGC 7023 is the young pre-main-sequence Be star HD 200755. We present our near-infrared high-resolution (R ~ 40,000) spectrum of NGC 7023, covering a region of $1{\times}15$ arcseconds, observed during the commissioning runs of IGRINS (Immersion GRating near-INfrared Spectrometer). The spectrum shows many strong narrow emission lines that arise from the molecular rovibrational transitions of H2. From the intensity ratios between these H2 lines, we investigate physical conditions within the PDR such as the temperature, density, and pressure. The high spectral resolution of IGRINS allows us to resolve the velocity field of the PDR. In addition, we compare the IGRINS spectrum to Cloudy PDR model.

  • PDF

MFSK Signal Individual Identification Algorithm Based on Bi-spectrum and Wavelet Analyses

  • Ye, Fang;Chen, Jie;Li, Yibing;Ge, Juan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권10호
    • /
    • pp.4808-4824
    • /
    • 2016
  • Signal individual reconnaissance and identification is an extremely important research topic in non-cooperative domains such as electronic countermeasures and intelligence reconnaissance. Facing the characteristics of the complexity and changeability of current communication environment, how to realize radiation source signal individual identification under the low SNR conditions is an emphasis of research. A novel emitter individual identification method combined bi-spectrum analysis with wavelet feature is presented in this paper. It makes a feature fusion of bi-spectrum slice characteristics and energy variance characteristics of the secondary wavelet transform coefficient to identify MFSK signals under the low SNR (signal-to-noise ratios) environment. Theoretical analyses and computer simulation results show that the proposed algorithm has good recognition performance with the ability to suppress noise and interference, and reaches the recognition rate of more than 90% when the SNR is -6dB.

Analysis of Solar Microwave Burst Spectrum, I. Nonuniform Magnetic Field

  • Lee, Jeongwoo
    • Journal of Astronomy and Space Sciences
    • /
    • 제35권4호
    • /
    • pp.211-218
    • /
    • 2018
  • Solar microwave bursts carry information about the magnetic field in the emitting region as well as about electrons accelerated during solar flares. While this sensitivity to the coronal magnetic field must be a unique advantage of solar microwave burst observations, it also adds a complexity to spectral analysis targeted to electron diagnostics. This paper introduces a new spectral analysis procedure in which the cross-section and thickness of a microwave source are expressed as power-law functions of the magnetic field so that the degree of magnetic inhomogeneity can systematically be derived. We applied this spectral analysis tool to two contrasting events observed by the Owens Valley Solar Array: the SOL2003-04-04T20:55 flare with a steep microwave spectrum and the SOL2003-10-19T16:50 flare with a broader spectrum. Our analysis shows that the strong flare with the broader microwave spectrum occurred in a region of highly inhomogeneous magnetic field and vice versa. We further demonstrate that such source properties are consistent with the magnetic field observations from the Michelson Doppler Imager instrument onboard the Solar and Heliospheric Observatory (SOHO) spacecraft and the extreme ultraviolet imaging observations from the SOHO extreme ultraviolet imaging telescope. This spectral inversion tool is particularly useful for analyzing microwave flux spectra of strong flares from magnetically complex systems.

몬테칼로 기법을 이용한 CBCT의 광자선 특성 및 선량 분석 (Analysis of Photon Characteristics and Absorbed Dose with Cone Beam Computed Tomography (CBCT) using Monte Carlo Method)

  • 김종보;김정훈;박은태
    • 한국방사선학회논문지
    • /
    • 제11권3호
    • /
    • pp.161-169
    • /
    • 2017
  • 방사선 치료 시 자세 확인 촬영을 목적으로 3차원 영상 획득이 가능한 콘빔씨티 촬영이 많이 이용되고 있다. 본 연구에서는 몬테칼로 기법을 이용한 모의실험을 통해 콘빔씨티 촬영 시 피폭선량을 정략적으로 분석하고 표준화된 데이터를 제시하고자 한다. 실험은 MCNPX(ver. 2.5.0)를 이용하였으며, 먼저 콘빔씨티를 모사한 후 광자선 스펙트럼을 분석하였다. 그리고 물 팬텀을 모사하여 깊이별 심부선량 백분율과 흡수선량을 측정하였다. 광자선 스펙트럼을 분석한 결과, 관전압 80 ~ 120 kVp 에서 평균 에너지는 조건에 따라 25.7 ~ 52.6 keV로 나타났으며 특성X선 에너지는 9, 60, 68, 70 keV로 나타났다. 물 팬텀을 사용하여 심부선량 백분율을 측정한 결과 표면에서 최대선량이 나타났으며 깊이가 깊어질수록 감소하는 것으로 나타났다. 흡수선량 또한 깊이가 증가할수록 감소하였으며 팬텀 전체가 받는 흡수선량은 9.7 ~ 18.7 mGy로 나타났다. 이는 일반적으로 방사선 치료에 사용되는 주당 처방선량인 약 10Gy의 0.2%를 차지하는 선량이며 이는 치료효과에는 큰 영향을 미치지 않을 것으로 판단된다. 그러나 처방선량에 비해 미미한 수준일지라도 이를 간과해서는 안 될 것이다.