• Title/Summary/Keyword: Radiation spectrum

Search Result 504, Processing Time 0.026 seconds

Measurement of Gamma ray Spectrum for the 27Al(p,3p+n)24Na Nuclear Reaction by using 100 MeV Proton Acceleration System (100 MeV 양성자가속기를 이용한 27Al(p,3p+n)24Na 핵반응에 대한 감마선 스펙트럼 측정)

  • Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.55-59
    • /
    • 2015
  • Research about the proton nuclear reaction is actively achieving on the proton therapy including material development of fusion reactor. The proton induced gamma ray energy(2754, 1386 keV) spectrum of 27Al(p,3p+n)24Na reaction was measured with 100 MeV high energy proton beam. The proton beam in the experiment was derived from 100 MeV proton linear accelerator in the KOMAC. We measured the gamma ray intensity ratio of the decay level from the energy spectrum. The previous results have been compared with the current result. Strength of measured gamma rays will provide very important information though decide high energy gamma radiation detection efficiency.

Numerical Study on Shape Optimization of a Heaving Hemisphere Wave Energy Converter (상하 운동 반구형 파력 발전기의 최적 형상 조건 수치해석)

  • Kim, Sung-Jae;Koo, Weoncheol;Heo, Kyung-Uk;Heo, Sanghwan
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.4
    • /
    • pp.254-262
    • /
    • 2015
  • Parametric study on submerged body shape of an oscillating hemisphere point absorber was conducted to predict the optimal relation between radius and draft of the body. As an additional damping due to power takeoff system, the optimal damping same as wave radiation damping was applied to the PTO system to produce the maximum wave power. Body response spectrum and power spectrum were obtained for various peak frequencies on wave spectra. It was found that the maximum power can be generated when the peak frequency of available wave power was 20% greater than that of wave spectrum.

THE SWINGS EFFECTS OF THE A-X SYSTEM AND v''= 1-0 BAND OF CO

  • KIM SANG-JOON
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.2
    • /
    • pp.223-243
    • /
    • 1996
  • We have constructed a line-by-line model of the A-X system of CO in order to analyze the CO bands appearing in the UV spectra of comets. The model includes electronic, rotational, vibrational transitions, excitations by solar UV radiation, and effects of neutral and electron collisions. The major bands of the A-X system occur in the $1200 - 1800{\AA}$ range where the temporal variation of solar irradiation is significant. The solar spectrum in this spectral range shows many emission lines, which cause a significant Swings effect. We derived fluorescence efficiencies of the bands as functions of heliocentric velocity and cometocentric distance using a high resolution spectrum of the sun. We compared our model with a spectrum of comet P/Halley obtained with the IUE, and estimated that the UV Swings effects are less than 20 fluorescence efficiencies for the most bands of the A-X system. We discuss the temporal variation of solar UV irradiation and its effects on the fluorescence efficiencies. The study of the A-X system also requites knowledge of vibrational and rotational fluorescent processes in the infrared and radio regions because the majority of CO molecules in the coma is in the ground rotational states. The solar infrared spectrum near 5 microns, where the fundamental band of CO occurs, contains strong absorption lines of the fundamental band and hot bands of CO and its isotopes. We derived fluorescence efficiencies of the infrared band as functions of heliocentric velocity and cometrocentric distance. The solar absorption lines near 5 microns cause a 20 reduction of the g-factor of the fundamental band at heliocentric velocities close to 0 km/sec. We discuss the effects of neutral and electron collisions on the fluorescence efficiencies of the infrared and UV bands.

  • PDF

Development and verification of a novel system for computed tomography scanner model construction in Monte Carlo simulations

  • Ying Liu;Ting Meng ;Haowei Zhang ;Qi Su;Hao Yan ;Heqing Lu
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4244-4252
    • /
    • 2022
  • The accuracy of Monte Carlo (MC) simulations in estimating the computed tomography radiation dose is highly dependent on the accuracy of CT scanner model. A system was developed to observe the 3D model intuitively and to calculate the X-ray energy spectrum and the bowtie (BT) filter model more accurately in Monte Carlo N-particle (MCNP). Labview's built-in Open Graphics Library (OpenGL) was used to display basic surfaces, and constructive solid geometry (CSG) method was used to realize Boolean operations. The energy spectrum was calculated by simulating the process of electronic shooting and the BT filter model was accurately modeled based on the calculated shape curve. Physical data from a study was used as an example to illustrate the accuracy of the constructed model. RMSE between the simulation and the measurement results were 0.97% and 0.74% for two filters of different shapes. It can be seen from the comparison results that to obtain an accurate CT scanner model, physical measurements should be taken as the standard. The energy spectrum library should be established based on Monte Carlo simulations with modifiable input files. It is necessary to use the three-segment splicing modeling method to construct the bowtie filter model.

Statistical Analysis of Count Rate Data for On-line Seawater Radioactivity Monitoring

  • Lee, Dong-Myung;Cong, Binh Do;Lee, Jun-Ho;Yeo, In-Young;Kim, Cheol-Su
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.2
    • /
    • pp.64-71
    • /
    • 2019
  • Background: It is very difficult to distinguish between a radioactive contamination source and background radiation from natural radionuclides in the marine environment by means of online monitoring system. The objective of this study was to investigate a statistical process for triggering abnormal level of count rate data measured from our on-line seawater radioactivity monitoring. Materials and Methods: Count rate data sets in time series were collected from 9 monitoring posts. All of the count rate data were measured every 15 minutes from the region of interest (ROI) for $^{137}Cs$ ($E_{\gamma}=661.6keV$) on the gamma-ray energy spectrum. The Shewhart ($3{\sigma}$), CUSUM, and Bayesian S-R control chart methods were evaluated and the comparative analysis of determination methods for count rate data was carried out in terms of the false positive incidence rate. All statistical algorithms were developed using R Programming by the authors. Results and Discussion: The $3{\sigma}$, CUSUM, and S-R analyses resulted in the average false positive incidence rate of $0.164{\pm}0.047%$, $0.064{\pm}0.0367%$, and $0.030{\pm}0.018%$, respectively. The S-R method has a lower value than that of the $3{\sigma}$ and CUSUM method, because the Bayesian S-R method use the information to evaluate a posterior distribution, even though the CUSUM control chart accumulate information from recent data points. As the result of comparison between net count rate and gross count rate measured in time series all the year at a monitoring post using the $3{\sigma}$ control charts, the two methods resulted in the false positive incidence rate of 0.142% and 0.219%, respectively. Conclusion: Bayesian S-R and CUSUM control charts are better suited for on-line seawater radioactivity monitoring with an count rate data in time series than $3{\sigma}$ control chart. However, it requires a continuous increasing trend to differentiate between a false positive and actual radioactive contamination. For the determination of count rate, the net count method is better than the gross count method because of relatively a small variation in the data points.

Geant4 Code Based Simulation of 6 MV Photon Beam for Analysis of Dose Distribution (Geant4 코드를 이용한 선형가속기 6 MV 광자선의 선량분포에 관한 연구)

  • Lee, Jun-Seong;Kim, Yang-Soo;Lee, Sun-Young
    • Journal of radiological science and technology
    • /
    • v.45 no.5
    • /
    • pp.449-455
    • /
    • 2022
  • This study is to present a Geant4 code for the simulation of the absorbed dose distribution given by a medical linac for 6 MV photon beam. The dose distribution was verified by comparison with calculated beam data and beam data measured in water phantom. They were performed for percentage depth dose(PDD) and beam profile of cross-plane for two field sizes of 10 × 10 and 15 × 15 cm2. Deviations of a percentage and distance were obtained. In energy spectrum, the mean energy was 1.69 MeV. Results were in agreement with PDD and beam profile of the phantom with a tolerance limit. The differences in the central beam axis data 𝜹1 for PDD had been less than 2% and in the build up region, these differences increased up to 4.40% for 10 cm square field. The maximum differences of 𝜹2 for beam profile were calculated with a result of 4.35% and 5.32% for 10 cm, 15 cm square fields, respectively. It can be observed that the difference was below 4% in 𝜹3 and 𝜹4. For two field sizes of 𝜹50-90 and RW50, the results agreed to within 2 mm. The results of the t-test showed that no statistically significant differences were found between the data for PDD of 𝜹1, p>0.05. A significant difference on PDD was observed for field sizes of 10 × 10 cm2, p=0.041. No significant differences were found in the beam profile of 𝜹3, 𝜹4, RW50, and 𝜹50-90. Significant differences on beam profile of 𝜹2 were observed for field sizes of 10 × 10 cm2, p=0.025 and for 15 × 15 cm2, p=0.037. This work described the development and reproducibility of Geant4 code for verification of dose distribution.

Automatic Determination of the Energy Pulse-height Relationship in NaI(TI) Spectra (NaI(T1) 검출기 스펙트럼의 에너지-채널 관계 자동결정)

  • Lee, M.S.
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.3
    • /
    • pp.143-151
    • /
    • 1997
  • As the pulse heights from a NaI(Tl) detector vary with the temperature of the measuring environment a significant change in temperature may affect the energy calibration of the spectrometer. The auto-adjustment of the channel corresponding to a pulse heights can be achieved by introducing an external reference source to compensate the temperature dependency of pulse heights, but unfavorable increases of the Compton continuum are caused due to the external source. In this study, the total absorption peaks dominant in the typical environmental gamma spectrum-239 keV from $^{212}Pb$, 351 keV from $^{214}Pb$, 1460 keV from $^{40}K$ and 2614 keV from $^{208}Tl$ for examples - were used as reference in the correction of energy calibration. With these peaks, the program to calibrate the energy of the s spectrum was developed using Microsoft Visual Basic language. The program developed here was applied to the environmental spectra measured at intervals of 30 minutes in the temperature range of from $-20^{\circ}C$ to $10^{\circ}C$ to demonstrate the validity and applicability. As a result of the test, the correction scheme appeared to be effective in the temperature changes encountered in the usual environment.

  • PDF

Calculation of Low-Energy Reactor Neutrino Spectra for Reactor Neutrino Experiments

  • Riyana, Eka Sapta;Suda, Shoya;Ishibashi, Kenji;Matsuura, Hideaki;Katakura, Jun-ichi
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.155-159
    • /
    • 2016
  • Background: Nuclear reactors produce a great number of antielectron neutrinos mainly from beta-decay chains of fission products. Such neutrinos have energies mostly in MeV range. We are interested in neutrinos in a region of keV, since they may take part in special weak interactions. We calculate reactor antineutrino spectra especially in the low energy region. In this work we present neutrino spectrum from a typical pressurized water reactor (PWR) reactor core. Materials and Methods: To calculate neutrino spectra, we need information about all generated nuclides that emit neutrinos. They are mainly fission fragments, reaction products and trans-uranium nuclides that undergo negative beta decay. Information in relation to trans-uranium nuclide compositions and its evolution in time (burn-up process) were provided by a reactor code MVP-BURN. We used typical PWR parameter input for MVP-BURN code and assumed the reactor to be operated continuously for 1 year (12 months) in a steady thermal power (3.4 GWth). The PWR has three fuel compositions of 2.0, 3.5 and 4.1 wt% $^{235}U$ contents. For preliminary calculation we adopted a standard burn-up chain model provided by MVP-BURN. The chain model treated 21 heavy nuclides and 50 fission products. The MVB-BURN code utilized JENDL 3.3 as nuclear data library. Results and Discussion: We confirm that the antielectron neutrino flux in the low energy region increases with burn-up of nuclear fuel. The antielectron-neutrino spectrum in low energy region is influenced by beta emitter nuclides with low Q value in beta decay (e.g. $^{241}Pu$) which is influenced by burp-up level: Low energy antielectron-neutrino spectra or emission rates increase when beta emitters with low Q value in beta decay accumulate Conclusion: Our result shows the flux of low energy reactor neutrinos increases with burn-up of nuclear fuel.

A Study on Inter Band Interference and PAPR Reduction in Multi-Cell System based on OFDM Techniques (OFDM 기법에 기반한 Multi-Cell 시스템에서 PAPR 감소와 대역간 간섭에 관한 연구)

  • Kim, Wan-Tae;Yoo, Sun-Yong;Jo, Sung-Joon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.10a
    • /
    • pp.693-696
    • /
    • 2008
  • The systems for mobile communication services of fourth generation use OFDM (Orthogonal Frequency Division Multiplexing) scheme that ran transmit large amounts of data to support the multimedia services, and consist of several types of cell, such as Macro Cell, Pico Cell, Femto Cell to improve the qualify of service. According to subdivision of communication region, superposition of cells in co-channel different from conventional single cell is used, but it cause inter band interference between systems. In particular, an OFDM signal consists of a number of independently modulated subcarriers, and superposition of these subcarriers causes a problem that ran give a large PAPR. Increased PAPR induces signal distortion passing through components such as power amplifier so that inter band interference is caused by out-of-band spectrum radiation. In order to minimize the inter band interference, this paper applies PAPR reduction scheme and analyzes the out-of-band spectrum radiation when the signal passes through nonlinear components such an power amplifier.

  • PDF

Calculations of ISO Narrow and ANSI X-Ray Spectra, Their Average Energies and Conversion Coefficients (ISO Narrow Series및 ANSI의 X선 스펙트럼, 평균에너지 및 선량환산인자의 이론적 계산)

  • Kim, Jang-Lyul;Kim, Bong-Whan;Chang, Si-Young;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.2
    • /
    • pp.129-136
    • /
    • 1995
  • In spite of the prescriptions on the reference X-ray fields given by the International Organization of Strandard(ISO) and American National Standard Institute(ANSI), the measurement of X-ray spectrum is not only time consuming but very difficult, paticularly when significant corrections have to be applied to the measured pulse-height distributions of the observed spectra. This paper describes the calculation method of ISO Narrow Series and ANSI X-ray filtered radiations by theoretical model which is modified framer's theory by target attenuation and backscatter correction. The X-ray spectra, average energies and conversion coefficients are calculated and compared with those obtained using the spectra prescribed by ISO and AMSI to assure good agreement.

  • PDF