Abstract
This study is to present a Geant4 code for the simulation of the absorbed dose distribution given by a medical linac for 6 MV photon beam. The dose distribution was verified by comparison with calculated beam data and beam data measured in water phantom. They were performed for percentage depth dose(PDD) and beam profile of cross-plane for two field sizes of 10 × 10 and 15 × 15 cm2. Deviations of a percentage and distance were obtained. In energy spectrum, the mean energy was 1.69 MeV. Results were in agreement with PDD and beam profile of the phantom with a tolerance limit. The differences in the central beam axis data 𝜹1 for PDD had been less than 2% and in the build up region, these differences increased up to 4.40% for 10 cm square field. The maximum differences of 𝜹2 for beam profile were calculated with a result of 4.35% and 5.32% for 10 cm, 15 cm square fields, respectively. It can be observed that the difference was below 4% in 𝜹3 and 𝜹4. For two field sizes of 𝜹50-90 and RW50, the results agreed to within 2 mm. The results of the t-test showed that no statistically significant differences were found between the data for PDD of 𝜹1, p>0.05. A significant difference on PDD was observed for field sizes of 10 × 10 cm2, p=0.041. No significant differences were found in the beam profile of 𝜹3, 𝜹4, RW50, and 𝜹50-90. Significant differences on beam profile of 𝜹2 were observed for field sizes of 10 × 10 cm2, p=0.025 and for 15 × 15 cm2, p=0.037. This work described the development and reproducibility of Geant4 code for verification of dose distribution.
Keywords
Radiation therapy; Geant4 code; Energy spectrum; Percentage depth dose; Beam profile;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Pandola L, Andenna C, Caccia B. Validation of the GEANT4 simulation of bremsstrahlung from thick targets below 3 MeV. Nuclear Instruments and Methods in Physics Research B. 2015;41-8.
2 Agostinelli S, Allison J, Amako K, Apostolakis J, Araujo H, Arce P, et al. Geant4-a simulation toolkit. Nuclear Instruments and Methods in Physics Research A. 2003;506(3):250-303.   DOI
3 Kang SK, Ahn SH, Kim CY. A Study on Photon Dose Calculation in 6 MV Linear Accelerator Based on Monte Carlo Method. Journal of Radiological Science and Technology. 2011;34(1):43-50.
4 International Atomic Energy Agency. Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water. Technical Reports Series No. 398; 2000.
5 International Atomic Energy Agency. Commissioning and quality assurance of computerized planning systems for radiation treatment of cancer. Technical Reports Series No.430; 2004.
6 Venselaar J, Welleweerd H, Mijnheer B. Tolerances for the accuracy of photon beam dose calculations of treatment planning systems. Radiotherapy and Oncology 60. 2001;191-201.   DOI
7 Mesbahi A, Fix M, Allahverdi M, Grein E, Garaati H. Monte Carlo calculation of Varian 2300C/D Linac photon beam characteristics: A comparison between MCNP4C, GEANT3 and measurements. Applied Radiation and Isotopes 62. 2005;469-77.   DOI
8 Baumgartner A, Steurer A, Maringer FJ. Simulation of photon energy spectra from Varian 2100C and 2300C/D Linacs: Simplified estimates with PENELOPE Monte Carlo models. Applied Radiation and Isotopes 67. 2009;2007-12.   DOI
9 Chetty IJ, Curran B, Cygler JE, DeMarco JJ, Ezzell G, Faddegon BA, et al. Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning. Med. Phys. 2007;34(12):4818-36.   DOI
10 Fix MK, Keller H, RRegsegger P, Born EJ. Simple beam models for Monte Carlo photon beam dose calculations in radiotherapy. Med Phys. 2000; 27(12):2739-47.   DOI
11 Ding GX. Using Monte Carlo simulations to commission photon beam output factors-A feasibility study. Physics in Medicine & Biology. 2003;48(23): 3865-74.   DOI
12 Mesbahi A, Reilly AJ, Thwaites DI. Development and commissioning of a Monte Carlo photon beam model for Varian Clinac 2100EX linear accelerator. Applied Radiation and Isotopes. 2006;64(6):656-62.   DOI
13 Sardari D, Maleki R, Samavat H, Esmaeeli A. Measurement of depth-dose of linear accelerator and simulation by use of Geant4 computer code. Reports of Practical Oncology and Radiotherapy. 2010;64-8.
14 Ding GX. Dose discrepancies between Monte Carlo calculations and measurements in the buildup region for a high-energy photon beam. Med. Phys. 2002;29(11):2459-63.   DOI
15 Andreo P. Monte Carlo techniques in medical radiation physics. Physics in Medicine & Biology. 1991;36(7):861-920.   DOI
16 Keall PJ, Siebers JV, Arnfield M, Kim JO, Mohan R. Monte Carlo dose calculations for dynamic IMRT treatments. Phys. Med. Biol. 2001;46.
17 Tzedakis A, Damilakis JE, Mazonakis M, Stratakis J, Varveris H, Gourtsoyiannis N. Influence of initial electron beam parameters on Monte Carlo calculated absorbed dose distributions for radiotherapy photon beams. Med. Phys. 2004;31(4): 907-13.   DOI
18 Cho SH, Vassiliev ON, Lee SS, Liu HH, Ibbott GS, Mohan R. Reference photon dosimetry data and reference phase space data for the 6 MV photon beam from Varian Clinac 2100 series linear accelerators. Med. Phys. 2005;32(1):137-48.   DOI
19 Bakkali JEL, Bardouni TEL. Validation of Monte Carlo Geant4 code for a 6 MV Varian linac. Journal of King Saud University-Science. 2017;29:106-13.   DOI
20 JimRnez Spang F. Monte Carlo Study of the Dosimetry of Small-Photon Beams Using CMOS Active Pixel Sensors [dissertation]. University College London; 2011.
21 Gonias P, Zaverdinos P, Alkhorayef M, Sulieman A, Kappas C, Theodorou K. Monte Carlo Simulation of 6MV Varian Clinac Photon Beam Using GEANT4-GATE. J At Nucl Phys. 2020;2(1):30-8.
22 Ahnesjo A, Aspradakis MM. Dose calculations for external photon beams in radiotherap. Phys. Med. Biol. 1999;44(11):R99-155.   DOI
23 Verhaegen F, Seuntjens J. Monte Carlo modelling of external radiotherapy photon beams. Phys. Med. Biol. 2003;48(21):R107-64.   DOI
24 Chauvie S, Scielzo G. Radiotherapy treatment planning with Monte Carlo on a distributed system. IEEE. 2004;1765-9.
25 An JS, Lee CL, Baek CH. Monte Carlo Simulation of a Varian 21EX Clinac 6 MV Photon Beam Characteristics Using GATE6. Journal of Radiological Science and Technology. 2016;39(4):571-5.   DOI
26 Sheikh-Bagheri D, Rogers DWO. Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code. Med. Phys. 2002;29(3):391-402.   DOI
27 Ivanchenko V, Apostolakis J, Bagulya A, Abdelouahed HB, Black R, Bogdanov A, et al. Recent Improvements in Geant4 Electromagnetic Physics Models and Interfaces. Progress in Nuclear Science and Technology. 2011;2:898-903.   DOI