• Title/Summary/Keyword: Radiation spectrum

Search Result 504, Processing Time 0.026 seconds

Upgrade of Neutron Energy Spectrometer with Single Multilayer Bonner Sphere Using Onion-like Structure

  • Mizukoshi, Tomoaki;Watanabe, Kenichi;Yamazaki, Atsushi;Uritan, Akira;Iguchi, Tetsuo;Ogata, Tomohiro;Muramatsu, Takashi
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.185-190
    • /
    • 2016
  • Background: In order to measure neutron energy spectra, the conventional Bonner Sphere Spectrometers (BSS) are widely used. In this spectrometer, several measurements with different size Bonner spheres are required. Operators should, therefore, place these spheres in several times to a measurement point where radiation dose might be relatively high. In order to reduce this effort, novel neutron energy spectrometer using an onion-like single Bonner sphere was proposed in our group. This Bonner sphere has multiple sensitive spherical shell layers in the single sphere. In this spectrometer, a band-shaped thermal neutron detection medium, which consists of a LiF-ZnS mixed powder scintillator sheet and a wavelength-shifting (WLS) fiber readout, was looped to each sphere at equal angular intervals. Amount of LiF neutron converter is reduced near polar region, where the band-shaped detectors are concentrated, in order to uniform the directional sensitivity. The LiF-ZnS mixed powder has an advantage of extremely high light yield. However, since it is opaque, scintillation photons cannot be collect uniformly. This type of detector shows no characteristic shape in the pulse height spectrum. Subsequently, it is difficult to set the pulse height discrimination level. This issue causes sensitivity fluctuation due to gain instability of photodetectors and/or electric modules. Materials and Methods: In order to solve this problem, we propose to replace the LiF-ZnS mixed powder into a flexible and Transparent RUbber SheeT type $LiCaAlF_6$ (TRUST LiCAF) scintillator. TRUST LiCAF scintillator can show a peak shape corresponding to neutron absorption events in the pulse height spectrum. Results and Discussion: We fabricated the prototype detector with five sensitive layers using TRUST LiCAF scintillator and conducted basic experiments to evaluate the directional uniformity of the sensitivity. Conclusion: The fabricated detector shows excellent directional uniformity of the neutron sensitivity.

Feasibility Study of Beta Detector for Small Leak Detection inside the Reactor Containment

  • Jang, JaeYeong;Schaarschmidt, Thomas;Kim, Yong Kyun
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.4
    • /
    • pp.154-159
    • /
    • 2018
  • Background: To prevent small leakage accidents, a real-time and direct detection system for small leaks with a detection limit below that of existing systems, e.g. $0.5gpm{\cdot}hr^{-1}$, is required. In this study, a small-size beta detector, which can be installed inside the reactor containment (CT) building and detect small leaks directly, was suggested and its feasibility was evaluated using MCNPX simulation. Materials and Methods: A target nuclide was selected through analysis of radiation from radionuclides in the reactor coolant system (RCS) and the spectrum was obtained via a silicon detector simulated in MCNPX. A window was designed to reduce the background signal caused by other nuclides. The sensitivity of the detector was also estimated, and its shielding designed for installation inside the reactor CT. Results and Discussion: The beta and gamma spectrum of the silicon detector showed a negligible gamma signal but it also contained an undesired peak at 0.22 MeV due to other nuclides, not the $^{16}N$ target nuclide. Window to remove the peak was derived as 0.4 mm for beryllium. The sensitivity of silicon beta detector with a beryllium window of 1.7 mm thickness was derived as $5.172{\times}10^{-6}{\mu}Ci{\cdot}cc^{-1}$. In addition, the specification of the shielding was evaluated through simulations, and the results showed that the integrity of the silicon detector can be maintained with lead shielding of 3 cm (<15 kg). This is a very small amount compared to the specifications of the lead shielding (600 kg) required for installation of $^{16}N$ gamma detector in inside reactor CT, it was determined that beta detector would have a distinct advantage in terms of miniaturization. Conclusion: The feasibility of the beta detector was evaluated for installation inside the reactor CT to detect small leaks below $0.5gpm{\cdot}hr^{-1}$. In future, the design will be optimized on specific data.

Evaluation of Radiological Effects on the Aptamers to Remove Ionic Radionuclides in the Liquid Radioactive Waste

  • Minhye Lee;Gilyong Cha;Dongki Kim;Miyong Yun;Daehyuk Jang;Sunyoung Lee;Song Hyun Kim;Hyuncheol Kim;Soonyoung Kim
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.1
    • /
    • pp.44-51
    • /
    • 2023
  • Background: Aptamers are currently being used in various fields including medical treatments due to their characteristics of selectively binding to specific molecules. Due to their special characteristics, the aptamers are expected to be used to remove radionuclides from a large amount of liquid radioactive waste generated during the decommissioning of nuclear power plants. The radiological effects on the aptamers should be evaluated to ensure their integrity for the application of a radionuclide removal technique. Materials and Methods: In this study, Monte Carlo N-Particle transport code version 6 (MCNP6) and Monte Carlo damage simulation (MCDS) codes were employed to evaluate the radiological effects on the aptamers. MCNP6 was used to evaluate the secondary electron spectrum and the absorbed dose in a medium. MCDS was used to calculate the DNA damage by using the secondary electron spectrum and the absorbed dose. Binding experiments were conducted to indirectly verify the results derived by MCNP6 and MCDS calculations. Results and Discussion: Damage yields of about 5.00×10-4 were calculated for 100 bp aptamer due to the radiation dose of 1 Gy. In experiments with radioactive materials, the results that the removal rate of the radioactive 60Co by the aptamer is the same with the non-radioactive 59Co prove the accuracy of the previous DNA damage calculation. Conclusion: The evaluation results suggest that only very small fraction of significant number of the aptamers will be damaged by the radioactive materials in the liquid radioactive waste.

Development of 3D Radiation Position Identification System of Multiple Radiation Sources using Plastic Scintillator and NaI(TI) Detector (플라스틱 Scintillator와 NaI(TI) 검출기를 이용한 다수의 방사선원 위치를 3차원으로 판별하는 측정시스템 개발)

  • Kwak, Dong-Hoon;Ko, Tae-Young;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.638-644
    • /
    • 2018
  • In this paper, we develop a measurement system that uses 3D Scintillator and NaI(TI) Detector to 3-dimensionally identify the location of multiple radiation sources in moving vehicle loads. The radiation measurement system consists of radiation measurement (plastic scintillator), 2-channel Pulse Counter Board, nuclide analysis (NaI(TI) detector) and 1 channel MCA Board. The source locator algorithm calculates the coordinate value of the ratio of the CPS value($1/r^2$) of the source according to the angle(${\theta}$) in inverse proportion to the square of the distance(X, Y) through the SVM classification. The coordinate values are input every predetermined period of the spectrum, and after analyzing the spectrum per unit cycle, the position of the nuclide at the time is calculated by determining whether or not the nuclide is present in the remaining part except for the background area. As a result of the position discrimination test, the error within the international standard of ${\pm}1m$ was shown. Thus, the utility of the proposed system has been demonstrated.

The Development of UV-IR Combination Flame Detector (UV-IR 복합형 화재감지장치 개발)

  • 이복영;권오승;정창기;박상태
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • All objects emit thermal radiation and this radiation is the basis of the techniques used to detect flames. The usual phenomena occurring in the initial stage of the fire are generally invisible products of a combustion and visible smoke. Liquid or gaseous materials do not undergo a smoldering stage so that fires develop very rapidly. Also, the heat generated by the initial flames is usually not sufficient to activate a heat detector. In this case the most effective criterion for automatic fire detection is the flame. According to the fire regulation of korea, the compulsory standard provided that a flame detector shall be installed in a place that the attachment height of detector is higher than 20 m, chemical plants, hangar, refinery, etc.. The results of the research and development are discriminated between a flame and other radiant emitters, developed a UV detector tube contains an inert gas which absorbs UV radiation, developed PZT pyroelectric element is based on the use of photovoltanic cell, developed IR band-pass filter that only allow a 4.3 $\mu\textrm{m}$ radiation wavelength to reach the sensors and developed UV-IR combination flame detector combined into a single detection device.

  • PDF

Variation of Wave Set-Up/set-Down due to the Evaluation of Radiation Stress (라디에이션 응력의 평가방법에 따른 평균수위변화)

  • 김경호;차기욱;조재희;윤영호
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.5 no.4
    • /
    • pp.263-270
    • /
    • 1993
  • A study on the variation of radiation stress and mean water level is carried out for the shoaling and breaking waves on a plane beach. In general, the radiation stresses computed based on the linear wave theory are overestimated. which results in the discrepancy between the computed results and laboratory data of mean water level in the surf zone. In this paper, by modifying the Svendsen's approach (1984), radiation stress is expressed in terms of water depth. The computed results are compared with the results calculated by a linear wave theory and Sawaragi's approach (1984) based on the spectrum of breaking wave components, and published laboratory data. The computed results of the modifed Svendsen's approach are favourably compared with the laboratory data.

  • PDF

ANALYSIS OF THE OCEAN' AND ATMOSPHERE ROLES IN THEIR HEAT INTERACTION WITH USE OF SATELLITE AND VESSEL

  • Grankov, Alexander Georgievich;Mil'shin, Alexander Alexeevich;Krapivin, Vladimir Fedorovich;Golovachev, Sergey Petrovich
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.1001-1002
    • /
    • 2006
  • Special problem emphasized by specialists in the field of analyzing the heat interchanges in the system ocean-atmosphere (SOA) is a necessity of determination of the near-surface atmospheric temperature, which can be only indirectly connected with characteristics of the SOA natural microwave radiation measured from satellites. That is why, the following dilemma is not obvious, but interesting and promised: what is better - to use the satellite methods for retrieving the partial parameters of the SOA or for analysis its state as a whole. To our opinion, this task is similar to the idea recognized by specialists engaged in the heat infrared region (8-12 mcm) of electromagnetic spectrum and its applications, where an intensity of natural infrared radiation (effective radiation) is used as the inherent property (the attribute) of the SOA heat balance. Here we studied important aspects of this problem: a) what medium initiates a heat transfer in the SOA and disturbs its heat balance - the ocean or the atmosphere b) what SOA parameters directly influence on its natural microwave radiation intensity (brightness temperature) measured from satellites? We relate these processes mainly to the synoptic range of time scales enriched by various events in the SOA interface such as the mid-latitude and tropical cyclones.

  • PDF

PHOTO-NEUTRON SOURCE USING 2 GEV ELECTRON LINAC FOR RADIATION SHIELDING RESEARCH

  • Lee, Hee-Seock;Bak, Joo-Shik;Chung, Chin-Wha;Ban, Syuichi;Shin, Kazuo;Sato, Tatsuhiko
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.333-335
    • /
    • 2001
  • The 2 GeV electron linac, the injector of the Pohang Light Source, was used as a photo-neutron source for radiation shielding research. The operational beam parameters are the nominal electron intensity of $0.5\;{\sim}5\;nC/sec$, the repetition rate of 10 Hz, and the beam pulse length of 1.0 nsec. One electron beam line was modified in order to install the target systems for producing pulsed photo-neutrons. The neutron spectrum and intensity were investigated by the time-of-flight technique. The reliable maximum energy of the measured neutrons was about 500 MeV. The number of neutrons above 20 MeV produced by one 1 GeV electron in a thick Pb target was about $6.45{\times}10^{-4}/sr$ at 90 degrees to the beam axis. The status of the photo-neutron source and the application research are presented.

  • PDF

Infrared Radiation Properties for SiO2 Films Made by Sol-Gel Process (졸-겔법으로 제조된 SiO2막의 적외선 복사특성에 관한 연구)

  • Kang, Byung-chul;Kim, Young-geun;Kim, Ki-ho
    • Korean Journal of Materials Research
    • /
    • v.13 no.10
    • /
    • pp.697-702
    • /
    • 2003
  • FT-IR and thermograph were used to investigate the infrared radiation characteristics of $SiO_2$film made by the sol-gel method. FT-IR spectrum of the $SiO_2$film showed high infrared absorption by Si-O-Si vibration at 1220, 1080, 800 and cm$460^{-1}$ The infrared absorption and radiation wavelength ranges of the $SiO_2$film measured by the integration method coincided with the reflection method, and the infrared emissivity was 0.65, equally. Depending on the bonding of elements, the infrared emissivity was high in the wavelength range where the infrared absorption rate was high, that follows the Kirchhoff's law. The emissivity showed the highest value in the wavelength range between $8∼10\mu\textrm{m}$. $SiO_2$film was considered as an efficient materials for infrared radiator at temperature below 10$0^{\circ}C$. The heat radiation temperature was $117^{\circ}C$ for the aluminum plate, but $146^{\circ}C$ for the $SiO_2$film after 7 minutes heat absorption, consiquently, $29^{\circ}C$ higher than the former.

CHARACTERISTICS OF FABRICATED SiC RADIATION DETECTORS FOR FAST NEUTRON DETECTION

  • Lee, Cheol-Ho;Kim, Han-Soo;Ha, Jang-Ho;Park, Se-Hwan;Park, Hyeon-Seo;Kim, Gi-Dong;Park, June-Sic;Kim, Yong-Kyun
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.70-74
    • /
    • 2012
  • Silicon carbide (SiC) is a promising material for neutron detection at harsh environments because of its capability to withstand strong radiation fields and high temperatures. Two PIN-type SiC semiconductor neutron detectors, which can be used for nuclear power plant (NPP) applications, such as in-core reactor neutron flux monitoring and measurement, were designed and fabricated. As a preliminary test, MCNPX simulations were performed to estimate reaction probabilities with respect to neutron energies. In the experiment, I-V curves were measured to confirm the diode characteristic of the detectors, and pulse height spectra were measured for neutron responses by using a $^{252}Cf$ neutron source at KRISS (Korea Research Institute of Standards and Science), and a Tandem accelerator at KIGAM (Korea Institute of Geoscience and Mineral Resources). The neutron counts of the detector were linearly increased as the incident neutron flux got larger.